{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,25]],"date-time":"2026-08-25T16:24:00Z","timestamp":1787675040279,"version":"build-2784847793"},"reference-count":8,"publisher":"Ovid Technologies (Wolters Kluwer Health)","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"abstract":"<jats:p>\n                    An 85-year-old woman underwent chest computed tomography (CT) during follow-up for COVID-19 infection, which incidentally revealed a 31-mm mass below the tracheal bifurcation. Because contrast-enhanced CT was not recommended due to renal impairment, endoscopic ultrasonography was performed and demonstrated intralesional blood flow, suggesting a vascular lesion. Dynamic and static\n                    <jats:sup>99m<\/jats:sup>\n                    Tc-human serum albumin-diethylenetriamine pentaacetic acid SPECT imaging using a full-ring multidetector CZT SPECT scanner was subsequently performed. Static images confirmed the vascular nature of the lesion, while dynamic 3D SPECT with 2-second serial acquisition and time-activity curve analysis demonstrated peak enhancement synchronized with the aorta, enabling definitive diagnosis of an aneurysm.\n                  <\/jats:p>","DOI":"10.1097\/rlu.0000000000006679","type":"journal-article","created":{"date-parts":[[2026,8,25]],"date-time":"2026-08-25T16:01:03Z","timestamp":1787673663000},"update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":0,"title":["Dynamic 3D Blood Pool SPECT Imaging Using a Full-Ring Multidetector CZT SPECT Scanner for Diagnosing Thoracic Aneurysm"],"prefix":"10.1097","author":[{"given":"Masahiro","family":"Koyama","sequence":"first","affiliation":[{"name":"Department of Radiology, Division of Nuclear Medicine, Saitama Medical University Hospital"},{"name":"Department of Nuclear Medicine, Saitama Medical University International Medical Center"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3471-2762","authenticated-orcid":false,"given":"Yohji","family":"Matsusaka","sequence":"additional","affiliation":[{"name":"Department of Radiology, Division of Nuclear Medicine, Saitama Medical University Hospital"},{"name":"Department of Nuclear Medicine, Saitama Medical University International Medical Center"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Masafumi","family":"Takahashi","sequence":"additional","affiliation":[{"name":"Department of Central Radiological Technology, Saitama Medical University Hospital, Saitama, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Akira","family":"Seto","sequence":"additional","affiliation":[{"name":"Department of Radiology, Division of Nuclear Medicine, Saitama Medical University Hospital"},{"name":"Department of Nuclear Medicine, Saitama Medical University International Medical Center"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ichiei","family":"Kuji","sequence":"additional","affiliation":[{"name":"Department of Radiology, Division of Nuclear Medicine, Saitama Medical University Hospital"},{"name":"Department of Nuclear Medicine, Saitama Medical University International Medical Center"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2026,8,21]]},"reference":[{"key":"R1-20260825","first-page":"27","article-title":"TC-99m-labeled red blood cell scintigraphy in the investigation of patients with hepatic cavernous hemangioma","volume":"5","author":"El-Desouki","year":"1999","journal-title":"Saudi J Gastroenterol"},{"key":"R2-20260825","doi-asserted-by":"crossref","first-page":"1023","DOI":"10.1016\/j.radcr.2021.02.024","article-title":"Giant esophageal hemangioma diagnosed by 99mTc-HSA-D scintigraphy following equivocal CT, MRI, and endoscopy","volume":"16","author":"Arizono","year":"2021","journal-title":"Radiol Case Rep"},{"key":"R3-20260825","first-page":"684","article-title":"Scintigraphy of hepatic hemangiomas: the value of Tc-99m-labeled red blood cells: concise communication","volume":"22","author":"Royal","year":"1981","journal-title":"J Nucl Med"},{"key":"R4-20260825","doi-asserted-by":"crossref","first-page":"1022","DOI":"10.1097\/00003072-200112000-00006","article-title":"Tc-99m-labeled RBC scintigraphy and splenic hemangioma","volume":"26","author":"Wijaya","year":"2001","journal-title":"Clin Nucl Med"},{"key":"R5-20260825","doi-asserted-by":"crossref","first-page":"189","DOI":"10.2214\/AJR.13.12383","article-title":"Utility of \u2079\u2079mTc-human serum albumin diethylenetriamine pentaacetic acid SPECT for evaluating endoleak after endovascular abdominal aortic aneurysm repair","volume":"204","author":"Nakai","year":"2015","journal-title":"AJR Am J Roentgenol"},{"key":"R6-20260825","doi-asserted-by":"crossref","first-page":"158","DOI":"10.1097\/00003072-199703000-00004","article-title":"Three-phase Tc-99m labeled RBC scintigraphy of a splenic hemangioma","volume":"22","author":"Phillpott","year":"1997","journal-title":"Clin Nucl Med"},{"key":"R7-20260825","doi-asserted-by":"crossref","first-page":"744","DOI":"10.1097\/MNM.0000000000000711","article-title":"The application of technetium-99m-red blood cell scintigraphy in the diagnosis of orbital cavernous hemangioma","volume":"38","author":"Dong","year":"2017","journal-title":"Nucl Med Commun"},{"key":"R8-20260825","doi-asserted-by":"crossref","first-page":"79","DOI":"10.1111\/cpf.12853","article-title":"First clinical experience of a ring-configured cadmium zinc telluride camera: a comparative study versus conventional gamma camera systems","volume":"44","author":"Ceri\u0107 Andelius","year":"2024","journal-title":"Clin Physiol Funct Imaging"}],"container-title":["Clinical Nuclear Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.1097\/RLU.0000000000006679","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,25]],"date-time":"2026-08-25T16:01:05Z","timestamp":1787673665000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.1097\/RLU.0000000000006679"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,8,21]]},"references-count":8,"URL":"https:\/\/doi.org\/10.1097\/rlu.0000000000006679","relation":{},"ISSN":["0363-9762","1536-0229"],"issn-type":[{"value":"0363-9762","type":"print"},{"value":"1536-0229","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,8,21]]},"assertion":[{"value":"2026-05-21","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2026-07-30","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}