{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,20]],"date-time":"2026-09-20T04:48:34Z","timestamp":1789879714894,"version":"4.0.1"},"reference-count":19,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"9","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2011,9]]},"DOI":"10.1097\/rlu.0b013e318219ac29","type":"journal-article","created":{"date-parts":[[2011,8,6]],"date-time":"2011-08-06T05:37:42Z","timestamp":1312609062000},"page":"770-771","source":"Crossref","is-referenced-by-count":5,"title":["Comparison of Pinhole and High-Resolution Parallel-Hole Imaging for Nodular Thyroid Disease"],"prefix":"10.1097","volume":"36","author":[{"given":"Mohammad A.","family":"Ghanem","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Abdelhamid H.","family":"Elgazzar","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mohammad M.","family":"Elsaid","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Fatima","family":"Shehab","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-7-20210204","first-page":"137","article-title":"Thyroid nodule.","volume":"55","author":"Clerc","year":"2005","journal-title":"Rev Prat"},{"key":"R2-7-20210204","first-page":"559","article-title":"Thyroid nodules.","volume":"67","author":"Orlov","year":"2003","journal-title":"Am Fam Physician"},{"key":"R3-7-20210204","first-page":"463","article-title":"Imaging procedures in the diagnosis of nodular goiter.","volume":"40","author":"L\u00f6ssner","year":"1985","journal-title":"Z Gesamte Inn Med"},{"issue":"suppl 2","key":"R4-7-20210204","doi-asserted-by":"crossref","first-page":"S425","DOI":"10.1007\/s00259-002-0811-8","article-title":"The continuing importance of thyroid scintigraphy in the era of high-resolution ultrasound.","volume":"29","author":"Meller","year":"2002","journal-title":"Eur J Nucl Med Mol Imaging"},{"key":"R5-7-20210204","doi-asserted-by":"crossref","first-page":"759","DOI":"10.1148\/129.3.759","article-title":"Thyroid scintigarphy: pinhole images versus rectilinear scans.","volume":"129","author":"Sostre","year":"1978","journal-title":"Radiology"},{"key":"R6-7-20210204","doi-asserted-by":"crossref","first-page":"163","DOI":"10.1097\/00003072-198304000-00005","article-title":"Another use for the seven-pinhole collimator routine non-tomographic imaging of the thyroid.","volume":"8","author":"Telepak","year":"1983","journal-title":"Clin Nucl Med"},{"key":"R7-7-20210204","doi-asserted-by":"crossref","first-page":"173","DOI":"10.2967\/jnmt.108.060509","article-title":"A survey of thyroid gland scintigraphy.","volume":"37","author":"Crawford","year":"2009","journal-title":"J Nucl Med Technol"},{"key":"R8-7-20210204","doi-asserted-by":"crossref","first-page":"189","DOI":"10.2967\/jnmt.108.055640","article-title":"Pinhole versus parallel-hole collimators for parathyroid imaging: an intraindividual comparison.","volume":"36","author":"Tomas","year":"2008","journal-title":"J Nucl Med Technol"},{"key":"R9-7-20210204","first-page":"1896","article-title":"Pediatric applications of pinhole magnification imaging.","volume":"40","author":"Connolly","year":"1999","journal-title":"J Nucl Med"},{"key":"R10-7-20210204","doi-asserted-by":"crossref","first-page":"341","DOI":"10.1148\/radiographics.18.2.9536482","article-title":"Pediatric skeletal scintigraphy: applications of pinhole magnification.","volume":"18","author":"Connolly","year":"1998","journal-title":"Radiographics"},{"key":"R11-7-20210204","doi-asserted-by":"crossref","first-page":"222","DOI":"10.1007\/BF01405305","article-title":"Osteoid osteoma: comparative utility of high-resolution planar and pinhole magnification scintigraphy.","volume":"26","author":"Roach","year":"1996","journal-title":"Pediatr Radiol"},{"key":"R12-7-20210204","doi-asserted-by":"crossref","first-page":"847","DOI":"10.1089\/thy.1997.7.847","article-title":"Role of high-resolution pinhole tomography in the evaluation of thyroid abnormalities.","volume":"7","author":"Krausz","year":"1997","journal-title":"Thyroid"},{"key":"R13-7-20210204","doi-asserted-by":"crossref","first-page":"9","DOI":"10.1097\/01.rlu.0000249401.48030.9c","article-title":"Preoperative dual-phase parathyroid imaging with tc-99m-sestamibi: accuracy and reproducibility of the pinhole collimator with and without oblique images.","volume":"32","author":"Arveschoug","year":"2007","journal-title":"Clin Nucl Med"},{"key":"R14-7-20210204","first-page":"24","article-title":"Pediatric Nuclear Medicine. 2nd ed.","author":"Davis","year":"1995"},{"key":"R15-7-20210204","first-page":"148","article-title":"Combined Scintigraphic and Radiographic Diagnosis of Bone and Joint Diseases.","author":"Bahk","year":"1994"},{"key":"R16-7-20210204","first-page":"25","article-title":"Introductory Physics of Nuclear Medicine.","author":"Chandra","year":"1992"},{"key":"R17-7-20210204","doi-asserted-by":"crossref","first-page":"949","DOI":"10.1097\/MNM.0b013e328309789e","article-title":"Comparison of pinhole and SPECT 99mTc-MIBI imaging in primary hyperparathyroidism.","volume":"29","author":"Ho Shon","year":"2008","journal-title":"Nucl Med Commun"},{"key":"R18-7-20210204","first-page":"32","article-title":"A comparison of contrast and sensitivity in Tc-99m thyroid scintigraphy between nine nuclear medicine centres of a geographic area.","volume":"8","author":"Alain","year":"2006","journal-title":"Alasbimn J"},{"key":"R19-7-20210204","doi-asserted-by":"crossref","first-page":"43","DOI":"10.1016\/S0001-2998(78)80006-3","article-title":"Technical considerations in vivo thyroid studies.","volume":"8","author":"Keyes","year":"1978","journal-title":"Semin Nucl Med"}],"container-title":["Clinical Nuclear Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.1097\/RLU.0b013e318219ac29","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,6]],"date-time":"2026-08-06T20:12:59Z","timestamp":1786047179000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/00003072-201109000-00007"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2011,9]]},"references-count":19,"journal-issue":{"issue":"9","published-print":{"date-parts":[[2011]]}},"URL":"https:\/\/doi.org\/10.1097\/rlu.0b013e318219ac29","relation":{},"ISSN":["0363-9762"],"issn-type":[{"value":"0363-9762","type":"print"}],"subject":[],"published":{"date-parts":[[2011,9]]}}}