{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,7]],"date-time":"2026-11-07T03:50:43Z","timestamp":1794023443881,"version":"4.8.0"},"reference-count":45,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"3","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2020,6]]},"abstract":"<jats:sec>\n            <jats:title>Abstract<\/jats:title>\n            <jats:p>Claustrophobia, other anxiety reactions, excessive motion, and other unanticipated patient events in magnetic resonance imaging (MRI) not only delay or preclude diagnostic-quality imaging but can also negatively affect the patient experience. In addition, by impeding MRI workflow, they may affect the finances of an imaging practice. This review article offers an overview of the various types of patient-related unanticipated events that occur in MRI, along with estimates of their frequency of occurrence as documented in the available literature. In addition, the financial implications of these events are discussed from a microeconomic perspective, primarily from the point of view of a radiology practice or hospital, although associated limitations and other economic viewpoints are also included. Efforts to minimize these unanticipated patient events can potentially improve not only patient satisfaction and comfort but also an imaging practice's operational efficiency and diagnostic capabilities.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/rmr.0000000000000243","type":"journal-article","created":{"date-parts":[[2020,6,22]],"date-time":"2020-06-22T03:41:49Z","timestamp":1592797309000},"page":"125-130","source":"Crossref","is-referenced-by-count":75,"title":["Prevalence and Financial Impact of Claustrophobia, Anxiety, Patient Motion, and Other Patient Events in Magnetic Resonance Imaging"],"prefix":"10.1097","volume":"29","author":[{"given":"Xuan V.","family":"Nguyen","sequence":"first","affiliation":[{"name":"Department of Radiology, The Ohio State University Wexner Medical Center, Columbus, OH"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sana","family":"Tahir","sequence":"additional","affiliation":[{"name":"The Ohio State University, Columbus, OH"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Brian W.","family":"Bresnahan","sequence":"additional","affiliation":[{"name":"Department of Radiology, University of Washington School of Medicine, Seattle, WA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jalal B.","family":"Andre","sequence":"additional","affiliation":[{"name":"Department of Radiology, University of Washington School of Medicine, Seattle, WA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Elvira V.","family":"Lang","sequence":"additional","affiliation":[{"name":"Hypnalgesics, LLC, Brookline, MA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mahmud","family":"Mossa-Basha","sequence":"additional","affiliation":[{"name":"Department of Radiology, University of Washington School of Medicine, Seattle, WA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nina A.","family":"Mayr","sequence":"additional","affiliation":[{"name":"Department of Radiation Oncology, University of Washington School of Medicine, Seattle, WA."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Eric C.","family":"Bourekas","sequence":"additional","affiliation":[{"name":"Department of Radiology, The Ohio State University Wexner Medical Center, Columbus, OH"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R2-20231002","doi-asserted-by":"crossref","first-page":"1322","DOI":"10.1002\/jmri.21147","article-title":"Claustrophobia during magnetic resonance imaging: cohort study in over 55,000 patients","volume":"26","author":"Dewey","year":"2007","journal-title":"J Magn Reson Imaging"},{"key":"R3-20231002","doi-asserted-by":"crossref","first-page":"401","DOI":"10.1002\/jmri.21012","article-title":"Claustrophobia and premature termination of magnetic resonance imaging examinations","volume":"26","author":"Eshed","year":"2007","journal-title":"J Magn Reson Imaging"},{"key":"R4-20231002","doi-asserted-by":"crossref","first-page":"293","DOI":"10.1111\/j.1440-1673.1998.tb00525.x","article-title":"Failed magnetic resonance imaging examinations due to claustrophobia","volume":"42","author":"Sarji","year":"1998","journal-title":"Australas Radiol"},{"key":"R5-20231002","doi-asserted-by":"crossref","first-page":"152","DOI":"10.1016\/j.ejrad.2007.02.012","article-title":"MR imaging of claustrophobic patients in an open 1.0T scanner: motion artifacts and patient acceptability compared with closed bore magnets","volume":"64","author":"Bangard","year":"2007","journal-title":"Eur J Radiol"},{"key":"R6-20231002","doi-asserted-by":"crossref","first-page":"765","DOI":"10.1016\/j.jacr.2017.01.043","article-title":"Prevalence of unanticipated events associated with MRI examinations: a benchmark for MRI quality, safety, and patient experience","volume":"14","author":"Sadigh","year":"2017","journal-title":"J Am Coll Radiol"},{"key":"R7-20231002","doi-asserted-by":"crossref","first-page":"131","DOI":"10.1016\/0005-7916(94)90005-1","article-title":"Anxiety and its determinants in patients undergoing magnetic resonance imaging","volume":"25","author":"Katz","year":"1994","journal-title":"J Behav Ther Exp Psychiatry"},{"key":"R8-20231002","doi-asserted-by":"crossref","first-page":"463","DOI":"10.1148\/radiology.170.2.2911670","article-title":"Anxiety in patients undergoing MR imaging","volume":"170","author":"Quirk","year":"1989","journal-title":"Radiology"},{"key":"R9-20231002","doi-asserted-by":"crossref","first-page":"1081","DOI":"10.1016\/j.mri.2008.01.022","article-title":"Claustrophobia in MRI: the role of cognitions","volume":"26","author":"Thorpe","year":"2008","journal-title":"Magn Reson Imaging"},{"key":"R10-20231002","doi-asserted-by":"crossref","first-page":"23","DOI":"10.1016\/j.jmir.2014.07.006","article-title":"Patient anxiety and satisfaction in a magnetic resonance imaging department: initial results from an action research study","volume":"46","author":"Munn","year":"2015","journal-title":"J Med Imaging Radiat Sci"},{"key":"R11-20231002","doi-asserted-by":"crossref","first-page":"318","DOI":"10.18071\/isz.68.0318","article-title":"Anxiety management and functional magnetic resonance imaging\u2014should it be a priority?","volume":"68","author":"Vandulek","year":"2015","journal-title":"Ideggyogy Sz"},{"key":"R12-20231002","first-page":"487","article-title":"Pinpointing moments of high anxiety during an MRI examination","volume":"21","author":"Van Minde","year":"2014","journal-title":"Int J Behav Med"},{"key":"R13-20231002","doi-asserted-by":"crossref","first-page":"160","DOI":"10.1016\/j.pscychresns.2010.01.005","article-title":"MRI-related anxiety levels change within and between repeated scanning sessions","volume":"182","author":"Chapman","year":"2010","journal-title":"Psychiatry Res"},{"key":"R14-20231002","doi-asserted-by":"crossref","first-page":"4341","DOI":"10.1038\/s41598-019-40737-w","article-title":"A study of the relationship between the level of anxiety declared by MRI patients in the STAI questionnaire and their respiratory rate acquired by a fibre-optic sensor system","volume":"9","author":"Dziuda","year":"2019","journal-title":"Sci Rep"},{"key":"R15-20231002","doi-asserted-by":"crossref","first-page":"889","DOI":"10.1002\/hbm.20229","article-title":"Cortisol responses of healthy volunteers undergoing magnetic resonance imaging","volume":"27","author":"Tessner","year":"2006","journal-title":"Hum Brain Mapp"},{"key":"R16-20231002","doi-asserted-by":"crossref","first-page":"118","DOI":"10.1016\/j.ijpsycho.2010.09.009","article-title":"The scanner as a stressor: evidence from subjective and neuroendocrine stress parameters in the time course of a functional magnetic resonance imaging session","volume":"79","author":"Muehlhan","year":"2011","journal-title":"Int J Psychophysiol"},{"key":"R17-20231002","doi-asserted-by":"crossref","first-page":"180","DOI":"10.1016\/j.mri.2014.08.024","article-title":"Can MRI related patient anxiety be prevented?","volume":"33","author":"Tazegul","year":"2015","journal-title":"Magn Reson Imaging"},{"key":"R18-20231002","doi-asserted-by":"crossref","first-page":"1571","DOI":"10.1016\/j.acra.2015.08.020","article-title":"The relation between anticipatory anxiety and movement during an MR examination","volume":"22","author":"Klaming","year":"2015","journal-title":"Acad Radiol"},{"key":"R19-20231002","doi-asserted-by":"crossref","first-page":"689","DOI":"10.1016\/j.jacr.2015.03.007","article-title":"Toward quantifying the prevalence, severity, and cost associated with patient motion during clinical MR examinations","volume":"12","author":"Andre","year":"2015","journal-title":"J Am Coll Radiol"},{"key":"R21-20231002","doi-asserted-by":"crossref","first-page":"1024","DOI":"10.1001\/jama.2018.1150","article-title":"Health care spending in the United States and other high-income countries","volume":"319","author":"Papanicolas","year":"2018","journal-title":"JAMA"},{"key":"R22-20231002","doi-asserted-by":"crossref","first-page":"10","DOI":"10.1002\/jmri.1880060105","article-title":"Economics of MRI technology","volume":"6","author":"Bell","year":"1996","journal-title":"J Magn Reson Imaging"},{"key":"R23-20231002","doi-asserted-by":"crossref","first-page":"333","DOI":"10.1148\/radiol.2016160749","article-title":"Costing in radiology and health care: rationale, relativity, rudiments, and realities","volume":"282","author":"Rubin","year":"2017","journal-title":"Radiology"},{"key":"R24-20231002","doi-asserted-by":"crossref","first-page":"963","DOI":"10.1016\/j.jacr.2017.03.015","article-title":"Effects of interpersonal skills training on MRI operations in a saturated market: a randomized trial","volume":"14","author":"Ajam","year":"2017","journal-title":"J Am Coll Radiol"},{"key":"R25-20231002","doi-asserted-by":"crossref","first-page":"845","DOI":"10.1148\/radiol.2017162187","article-title":"External factors that influence the practice of radiology: proceedings of the international society for strategic studies in radiology meeting","volume":"283","author":"Rubin","year":"2017","journal-title":"Radiology"},{"key":"R26-20231002","doi-asserted-by":"crossref","first-page":"1040","DOI":"10.1002\/jmri.25219","article-title":"Effect of team training on improving MRI study completion rates and no-show rates","volume":"44","author":"Norbash","year":"2016","journal-title":"J Magn Reson Imaging"},{"key":"R27-20231002","doi-asserted-by":"crossref","first-page":"114","DOI":"10.1016\/j.jradnu.2012.08.001","article-title":"A better patient experience through better communication","volume":"31","author":"Lang","year":"2012","journal-title":"J Radiol Nurs"},{"key":"R28-20231002","doi-asserted-by":"crossref","first-page":"4","DOI":"10.1186\/1471-2342-11-4","article-title":"Reduction of claustrophobia during magnetic resonance imaging: methods and design of the \u201cCLAUSTRO\u201d randomized controlled trial","volume":"11","author":"Enders","year":"2011","journal-title":"BMC Med Imaging"},{"key":"R29-20231002","doi-asserted-by":"crossref","first-page":"1063","DOI":"10.1016\/j.acra.2013.05.012","article-title":"Major regulatory changes and the impact on diagnostic imaging in the United States 2005 to 2012 \u2217: \u2217effective May 15, 2013","volume":"20","author":"Relyea-Chew","year":"2013","journal-title":"Acad Radiol"},{"key":"R30-20231002","doi-asserted-by":"crossref","first-page":"51","DOI":"10.1016\/S0730-725X(96)00351-7","article-title":"Adult claustrophobia, anxiety and sedation in MRI","volume":"15","author":"Murphy","year":"1997","journal-title":"Magn Reson Imaging"},{"key":"R31-20231002","doi-asserted-by":"crossref","first-page":"924","DOI":"10.1016\/j.jacr.2017.01.025","article-title":"MRI utilization and the associated use of sedation and anesthesia in a pediatric ACO","volume":"14","author":"Uffman","year":"2017","journal-title":"J Am Coll Radiol"},{"key":"R32-20231002","doi-asserted-by":"crossref","first-page":"645","DOI":"10.1148\/radiology.216.3.r00se45645","article-title":"Sedation procedures in MR imaging: safety, effectiveness, and nursing effect on examinations","volume":"216","author":"Bluemke","year":"2000","journal-title":"Radiology"},{"key":"R33-20231002","doi-asserted-by":"crossref","first-page":"293","DOI":"10.2214\/ajr.177.2.1770293","article-title":"Sedation and analgesia in MR imaging","volume":"177","author":"Berlin","year":"2001","journal-title":"AJR Am J Roentgenol"},{"key":"R34-20231002","doi-asserted-by":"crossref","first-page":"1775","DOI":"10.1016\/j.jacr.2018.01.017","article-title":"Economics of MRI operations after implementation of interpersonal skills training","volume":"15","author":"Ladapo","year":"2018","journal-title":"J Am Coll Radiol"},{"key":"R35-20231002","doi-asserted-by":"crossref","DOI":"10.1002\/jmri.27112","article-title":"Quantifying the financial savings of motion correction in brain MRI: a model-based estimate of the costs arising from patient head motion and potential savings from implementation of motion correction","author":"Slipsager","year":"2020","journal-title":"J Magn Reson Imaging"},{"key":"R36-20231002","doi-asserted-by":"crossref","first-page":"185","DOI":"10.1016\/j.jval.2016.11.013","article-title":"Evaluating frameworks that provide value measures for health care interventions","volume":"20","author":"Mandelblatt","year":"2017","journal-title":"Value Health"},{"key":"R37-20231002","doi-asserted-by":"crossref","first-page":"119","DOI":"10.1016\/j.jval.2017.12.012","article-title":"A health economics approach to us value assessment frameworks-introduction: an ISPOR Special Task Force Report","volume":"21","author":"Neumann","year":"2018","journal-title":"Value Health"},{"key":"R38-20231002","doi-asserted-by":"crossref","first-page":"135","DOI":"10.1097\/RMR.0000000000000241","article-title":"Reducing cardiac radiation dose from breast cancer radiation therapy with breath hold training and cognitive behavioral therapy","volume":"29","author":"Mayr","year":"2020","journal-title":"Top Magn Reson Imaging"},{"key":"R39-20231002","doi-asserted-by":"crossref","first-page":"149","DOI":"10.1097\/RMR.0000000000000244","article-title":"Complementary and alternative medicine (CAM) in cancer patients undergoing radiation therapy","volume":"29","author":"Borm","year":"2020","journal-title":"Top Magn Reson Imaging"},{"key":"R40-20231002","doi-asserted-by":"crossref","DOI":"10.1097\/RMR.0000000000000245","article-title":"Gentle touch: non-invasive approaches to improve patient comfort and cooperation for pediatric imaging","author":"Oztek","year":"2020","journal-title":"Top Magn Reson Imaging"},{"key":"R41-20231002","doi-asserted-by":"crossref","DOI":"10.1097\/RMR.0000000000000238","article-title":"Non-invasive approaches for anxiety reduction during interventional procedures","author":"Makary","year":"2020","journal-title":"Top Magn Reson Imaging"},{"key":"R42-20231002","doi-asserted-by":"crossref","DOI":"10.1097\/RMR.0000000000000248","article-title":"Virtual reality to relieve pain in burn patients undergoing imaging and treatment","author":"Bermo","year":"2020","journal-title":"Top Magn Reson Imaging"},{"key":"R43-20231002","doi-asserted-by":"crossref","first-page":"131","DOI":"10.1097\/RMR.0000000000000242","article-title":"Communication and team interactions to improve patient experiences, quality of care, and throughput in MRI","volume":"29","author":"Ajam","year":"2020","journal-title":"Top Magn Reson Imaging"},{"key":"R44-20231002","doi-asserted-by":"crossref","first-page":"157","DOI":"10.1097\/RMR.0000000000000239","article-title":"Underlying mechanisms of psychological interventions in MRI and image-guided radiology procedures","volume":"29","author":"Chadderdon","year":"2020","journal-title":"Top Magn Reson Imaging"},{"key":"R45-20231002","doi-asserted-by":"crossref","DOI":"10.1097\/RMR.0000000000000246","article-title":"Making magnets more attractive: physics and engineering contributions to patient comfort in MRI","author":"Brunnquell","year":"2020","journal-title":"Top Magn Reson Imaging"},{"key":"R46-20231002","doi-asserted-by":"crossref","DOI":"10.1097\/RMR.0000000000000249","article-title":"Applying artificial intelligence to mitigate effects of patient motion or other complicating factors on image quality","author":"Nguyen","year":"2020","journal-title":"Top Magn Reson Imaging"},{"key":"R47-20231002","doi-asserted-by":"crossref","DOI":"10.1097\/RMR.0000000000000247","article-title":"Practical considerations for radiologists in implementing a patient-friendly MRI experience","author":"Oztek","year":"2020","journal-title":"Top Magn Reson Imaging"}],"container-title":["Topics in Magnetic Resonance Imaging"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/RMR.0000000000000243","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,2]],"date-time":"2023-10-02T02:03:16Z","timestamp":1696212196000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/RMR.0000000000000243"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,6]]},"references-count":45,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2020]]}},"URL":"https:\/\/doi.org\/10.1097\/rmr.0000000000000243","relation":{},"ISSN":["0899-3459","1536-1004"],"issn-type":[{"value":"0899-3459","type":"print"},{"value":"1536-1004","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,6]]}}}