{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,17]],"date-time":"2026-02-17T03:44:50Z","timestamp":1771299890007,"version":"3.50.1"},"reference-count":17,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"2","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Ann Plast Surg"],"published-print":{"date-parts":[[2020,8]]},"abstract":"<jats:sec>\n            <jats:title>Background<\/jats:title>\n            <jats:p>Size discrepancy in microvascular anastomosis is a common issue in free flap transfer and replantation surgery. A number of different techniques have been described to overcome the problem, but optimal method continues to be defined.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods<\/jats:title>\n            <jats:p>Since June 2015 to May 2018, clinical courses of 103 microvascular cases performed by one senior surgeon were reviewed. Three end-to-end techniques including mechanical dilation, single-mattress suture, and wedge resection were applied in 364 anastomoses with caliber ratio between 1:1 and 1:1.5, 1:1.5 and 1:2, and 1:2 and 1: 3, respectively.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results<\/jats:title>\n            <jats:p>A total of 112 flaps were incorporated in this study. The incidence of anastomotic failure was 3.0% (11\/364), and the overall flap failure rate was 3.6% (4\/112). The failure cases included 2 replanted scalps, 1 replanted ear, and 1 superficial temporal artery flap for nasal reconstruction.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusions<\/jats:title>\n            <jats:p>Our results depicted operational convenience and reliability of the 3 end-to-end anastomotic techniques in addressing mild-to-large vessel discrepancy.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/sap.0000000000002158","type":"journal-article","created":{"date-parts":[[2020,1,8]],"date-time":"2020-01-08T17:38:44Z","timestamp":1578505124000},"page":"141-145","source":"Crossref","is-referenced-by-count":5,"title":["Three End-to-End Techniques for Microvascular Anastomosis of Vessels With Different Size Discrepancy"],"prefix":"10.1097","volume":"85","author":[{"given":"Yi","family":"Zhang","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tingliang","family":"Wang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ying","family":"Liu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jinguang","family":"He","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jiasheng","family":"Dong","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hua","family":"Xu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","reference":[{"key":"bib1-20230923","doi-asserted-by":"crossref","first-page":"722","DOI":"10.1097\/00006534-199809010-00016","article-title":"A review of 716 consecutive free flaps for oncologic surgical defects: refinement in donor-site selection and technique","volume":"102","year":"1998","journal-title":"Plast Reconstr Surg"},{"key":"bib2-20230923","doi-asserted-by":"crossref","first-page":"111","DOI":"10.1097\/00006534-197308000-00001","article-title":"Distant transfer of an island flap by microvascular anastomoses. A clinical technique","volume":"52","year":"1973","journal-title":"Plast Reconstr Surg"},{"key":"bib3-20230923","doi-asserted-by":"crossref","first-page":"259","DOI":"10.1097\/00006534-197403000-00002","article-title":"Successful clinical transfer of ten free flaps by microvascular anastomoses","volume":"53","year":"1974","journal-title":"Plast Reconstr Surg"},{"key":"bib4-20230923","doi-asserted-by":"crossref","first-page":"502","DOI":"10.1097\/00006534-198004000-00019","article-title":"Expansion of smaller vessel diameter by fish-mouth incision in microvascular anastomosis with marked size discrepancy","volume":"65","year":"1980","journal-title":"Plast Reconstr Surg"},{"key":"bib5-20230923","doi-asserted-by":"crossref","first-page":"162","DOI":"10.1002\/1098-2752(2000)20:4<162::AID-MICR3>3.0.CO;2-L","article-title":"Techniques for management of size discrepancies in microvascular anastomosis","volume":"20","year":"2000","journal-title":"Microsurgery"},{"key":"bib6-20230923","doi-asserted-by":"crossref","first-page":"619","DOI":"10.1016\/0007-1226(93)90118-U","article-title":"A new technique to anastomose vessels with great discrepancy in diameter","volume":"46","year":"1993","journal-title":"Br J Plast Surg"},{"key":"bib7-20230923","doi-asserted-by":"crossref","first-page":"173","DOI":"10.1002\/1098-2752(2000)20:4<173::AID-MICR5>3.0.CO;2-B","article-title":"Experimental microvascular sleeve anastomosis in size discrepancy vessels","volume":"20","year":"2000","journal-title":"Microsurgery"},{"key":"bib8-20230923","first-page":"128","article-title":"The V-plasty: a novel microsurgical technique for anastomosis of vessels with marked size discrepancy","volume":"32","year":"2016","journal-title":"J Reconstr Microsurg"},{"key":"bib9-20230923","doi-asserted-by":"crossref","first-page":"239","DOI":"10.1016\/j.jss.2014.03.011","article-title":"Healing of two microarterial anastomoses with diameter mismatch","volume":"191","year":"2014","journal-title":"J Surg Res"},{"key":"bib10-20230923","doi-asserted-by":"crossref","first-page":"497","DOI":"10.1055\/s-0029-1234028","article-title":"Managing venous discrepancy: simple method","volume":"25","year":"2009","journal-title":"J Reconstr Microsurg"},{"key":"bib11-20230923","doi-asserted-by":"crossref","first-page":"171","DOI":"10.1097\/SAP.0b013e3182275cf8","article-title":"The suitability of end-to-side microvascular anastomosis in free flap transfer for limb reconstruction","volume":"68","year":"2012","journal-title":"Ann Plast Surg"},{"key":"bib12-20230923","doi-asserted-by":"crossref","first-page":"185","DOI":"10.1111\/j.1445-2197.1982.tb06099.x","article-title":"End to side micro-arterial anastomosis: a simplified technique","volume":"52","year":"1982","journal-title":"Aust N Z J Surg"},{"key":"bib13-20230923","doi-asserted-by":"crossref","first-page":"1109","DOI":"10.1097\/00006534-199704000-00029","article-title":"A clinical study of end-to-end versus end-to-side techniques for microvascular anastomosis","volume":"99","year":"1997","journal-title":"Plast Reconstr Surg"},{"key":"bib14-20230923","doi-asserted-by":"crossref","first-page":"191","DOI":"10.1016\/S0301-2115(98)00190-0","article-title":"Microsurgery for intra-abdominal testicular retention","volume":"81","year":"1998","journal-title":"Eur J Obstet Gynecol Reprod Biol"},{"key":"bib15-20230923","doi-asserted-by":"crossref","first-page":"125","DOI":"10.1055\/s-2005-864846","article-title":"Interrupted micro-mattress sutures solve vessel-size discrepancy","volume":"21","year":"2005","journal-title":"J Reconstr Microsurg"},{"key":"bib16-20230923","doi-asserted-by":"crossref","first-page":"100","DOI":"10.1177\/229255031502300208","article-title":"Horizontal mattress technique for anastomosis of size-mismatched vessels","volume":"23","year":"2015","journal-title":"Plastic surgery"},{"key":"bib17-20230923","doi-asserted-by":"crossref","first-page":"285","DOI":"10.1002\/micr.1920110407","article-title":"Microvascular grafts: effect of diameter discrepancy on patency rates","volume":"11","year":"1990","journal-title":"Microsurgery"}],"container-title":["Annals of Plastic Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/SAP.0000000000002158","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,9,23]],"date-time":"2023-09-23T05:26:20Z","timestamp":1695446780000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/SAP.0000000000002158"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,8]]},"references-count":17,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2020]]}},"URL":"https:\/\/doi.org\/10.1097\/sap.0000000000002158","relation":{},"ISSN":["1536-3708","0148-7043"],"issn-type":[{"value":"1536-3708","type":"electronic"},{"value":"0148-7043","type":"print"}],"subject":[],"published":{"date-parts":[[2020,8]]}}}