{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,31]],"date-time":"2026-08-31T13:31:54Z","timestamp":1788183114886,"version":"build-2803163510"},"reference-count":35,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"6S","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Ann Plast Surg"],"published-print":{"date-parts":[[2021,6]]},"abstract":"<jats:sec>\n            <jats:title>Purpose<\/jats:title>\n            <jats:p>Inpatient surgery costs have risen 30% over the past 5 years, and the operating room accounts for up to 60% of total hospital operational expense. On average, only 13.0% to 21.9% of instruments opened for a case are used, contributing to significant avoidable reprocessing, repurchase, and labor expense.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods<\/jats:title>\n            <jats:p>A comprehensive review of 40 major instrument trays at UNC Rex Hospital was conducted using a technology service (OpFlow; Operative Flow Technologies, Raleigh, NC). Among the full scope of the project, the general plastics tray and breast reconstruction tray were evaluated for the plastic surgery service line over a 3-month period. Intraoperative data collection was performed on the exact instruments used across a standard breadth of cases. Data analytics were conducted stratifying instrument usage concordance among surgeons by tray and procedure type. After a surgeon-led review of the proposed new tray configurations, the optimized versions were implemented via a methodical change management process.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results<\/jats:title>\n            <jats:p>A total of 183 plastic surgery cases were evaluated across 17 primary surgeons. On average, the instrument usage per tray was 15.8% for the general plastics tray and 23.5% for the breast reconstruction tray. After stakeholder review, 32 (45.1%) of 71 instruments were removed from the general plastics tray and 40 (36.7%) of 109 were removed from the breast reconstruction tray, resulting in a total reduction of 2652 instruments. This resulted in a decrease of 81,696 instrument sterilization cycles annually. The removal of the instruments yielded an estimated cost avoidance of US $163,800 for instrument repurchase and US $69,441 in annual resterilization savings. The instrument volume reduction is projected to save 383.5 hours of sterile processing personnel time in tray assembly annually.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusions<\/jats:title>\n            <jats:p>An analytics-driven method applying empirical data on actual case-based instrument usage has implications for better efficiency, improved quality, and cost avoidance related to instrument repurchase and sterile processing. Given increasing cost constraints and the transition to value-based care models, leveraging a technology-based solution enables meaningful change in the sterile processing department as a source for cost reduction and quality of care improvement.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/sap.0000000000002913","type":"journal-article","created":{"date-parts":[[2021,6,8]],"date-time":"2021-06-08T14:06:20Z","timestamp":1623161180000},"page":"S635-S639","source":"Crossref","is-referenced-by-count":17,"title":["Data Analysis of Plastic Surgery Instrument Trays Yields Significant Cost Savings and Efficiency Gains"],"prefix":"10.1097","volume":"86","author":[{"given":"Benjamin C.","family":"Wood","sequence":"first","affiliation":[{"name":"UNC Rex Hospital, Raleigh"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sarah","family":"Konchan","sequence":"additional","affiliation":[{"name":"UNC Rex Hospital, Raleigh"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Samuel","family":"Gay","sequence":"additional","affiliation":[{"name":"UNC Rex Hospital, Raleigh"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sandeep","family":"Rath","sequence":"additional","affiliation":[{"name":"Department of Operations, UNC Kenan-Flagler Business School"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Vinayak","family":"Deshpande","sequence":"additional","affiliation":[{"name":"Department of Operations, UNC Kenan-Flagler Business School"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Martyn","family":"Knowles","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"bib1-20230923","doi-asserted-by":"crossref","first-page":"432","DOI":"10.1093\/neuros\/nyy275","article-title":"Greening the operating room: results of a scalable initiative to reduce waste and recover supply costs","volume":"85","year":"2019","journal-title":"Neurosurgery"},{"key":"bib2-20230923","first-page":"suppl 1\u20137","article-title":"Achieving operating room efficiency through process integration","volume":"57","year":"2003","journal-title":"Healthc Financ Manage"},{"key":"bib4-20230923","doi-asserted-by":"crossref","first-page":"67","DOI":"10.1177\/1062860618783261","article-title":"Implementation and impact of a hospital-wide instrument set review: early experiences at a multisite tertiary care academic institution","volume":"34","year":"2019","journal-title":"Am J Med Qual"},{"key":"bib5-20230923","doi-asserted-by":"crossref","first-page":"15","DOI":"10.1016\/j.jss.2018.03.038","article-title":"Reducing cost and improving operating room efficiency: examination of surgical instrument processing","volume":"229","year":"2018","journal-title":"J Surg Res"},{"key":"bib6-20230923","doi-asserted-by":"crossref","first-page":"165","DOI":"10.1067\/j.cpsurg.2016.02.001","article-title":"Environmentalism in surgical practice","volume":"53","year":"2016","journal-title":"Curr Probl Surg"},{"key":"bib7-20230923","first-page":"134","article-title":"Inventory management of surgical supplies and sterile instruments in hospitals: a literature review","volume":"8","year":"2018","journal-title":"Health Syst (Basingstoke)"},{"key":"bib9-20230923","doi-asserted-by":"crossref","first-page":"646","DOI":"10.1016\/j.jamcollsurg.2014.06.019","article-title":"Assessing the magnitude and costs of intraoperative inefficiencies attributable to surgical instrument trays","volume":"219","year":"2014","journal-title":"J Am Coll Surg"},{"key":"bib10-20230923","doi-asserted-by":"crossref","first-page":"46","DOI":"10.1186\/s40463-014-0046-2","article-title":"Reducing otolaryngology surgical inefficiency via assessment of tray redundancy","volume":"43","year":"2014","journal-title":"J Otolaryngol Head Neck Surg"},{"key":"bib11-20230923","doi-asserted-by":"crossref","first-page":"652.e1","DOI":"10.1016\/j.ajog.2016.06.019","article-title":"Costs associated with instrument sterilization in gynecologic surgery","volume":"215","year":"2016","journal-title":"Am J Obstet Gynecol"},{"key":"bib12-20230923","doi-asserted-by":"crossref","first-page":"277","DOI":"10.1111\/jhq.12053","article-title":"Application of lean methodology for improved quality and efficiency in operating room instrument availability","volume":"37","year":"2015","journal-title":"J Healthc Qual"},{"key":"bib13-20230923","doi-asserted-by":"crossref","first-page":"1441","DOI":"10.1016\/j.surg.2014.08.068","article-title":"Streamlining variability in hospital charges for standard thyroidectomy: developing a strategy to decrease waste","volume":"156","year":"2014","journal-title":"Surgery"},{"key":"bib14-20230923","doi-asserted-by":"crossref","first-page":"E404","DOI":"10.9778\/cmajo.20150092","article-title":"Comparing surgical trays with redundant instruments with trays with reduced instruments: a cost analysis","volume":"4","year":"2016","journal-title":"CMAJ Open"},{"key":"bib15-20230923","doi-asserted-by":"crossref","first-page":"82","DOI":"10.5430\/jha.v4n6p82","article-title":"Surgical instrumentation: the true cost of instrument trays and a potential strategy for optimization","volume":"4","year":"2015","journal-title":"J Hosp Admin"},{"key":"bib16-20230923","doi-asserted-by":"crossref","first-page":"2834","DOI":"10.1016\/j.arth.2019.07.040","article-title":"Optimization of orthopedic surgical instrument trays: lean principles to reduce fixed operating room expenses","volume":"34","year":"2019","journal-title":"J Arthroplasty"},{"key":"bib17-20230923","doi-asserted-by":"crossref","first-page":"215","DOI":"10.1177\/0194599819885635","article-title":"Surgical instrument optimization to reduce instrument processing and operating room setup time","volume":"162","year":"2020","journal-title":"Otolaryngol Head Neck Surg"},{"key":"bib18-20230923","doi-asserted-by":"crossref","first-page":"32","DOI":"10.1016\/j.jss.2018.06.063","article-title":"The impact of breast lumpectomy tray utilization on cost savings","volume":"233","year":"2019","journal-title":"J Surg Res"},{"key":"bib19-20230923","doi-asserted-by":"crossref","first-page":"1889","DOI":"10.1016\/j.athoracsur.2017.06.064","article-title":"Cost savings of standardization of thoracic surgical instruments: the process of lean","volume":"104","year":"2017","journal-title":"Ann Thorac Surg"},{"key":"bib20-20230923","doi-asserted-by":"crossref","first-page":"1843","DOI":"10.1016\/j.jpedsurg.2012.11.045","article-title":"Standardization of operative equipment reduces cost","volume":"48","year":"2013","journal-title":"J Pediatr Surg"},{"key":"bib21-20230923","first-page":"99","article-title":"Applying lean methods to improve quality and safety in surgical sterile instrument processing","volume":"39","year":"2013","journal-title":"Jt Comm J Qual Patient Saf"},{"key":"bib22-20230923","doi-asserted-by":"crossref","first-page":"2810","DOI":"10.1002\/lary.25407","article-title":"Impact of Lean on surgical instrument reduction: less is more","volume":"125","year":"2015","journal-title":"Laryngoscope"},{"key":"bib23-20230923","doi-asserted-by":"crossref","first-page":"1714","DOI":"10.1097\/BRS.0000000000000480","article-title":"Lean principles to optimize instrument utilization for spine surgery in an academic medical center: an opportunity to standardize, cut costs, and build a culture of improvement","volume":"39","year":"2014","journal-title":"Spine (Phila Pa 1976)"},{"key":"bib24-20230923","doi-asserted-by":"crossref","first-page":"20","DOI":"10.1016\/j.jpurol.2017.08.002","article-title":"Reduction and standardization of surgical instruments in pediatric inguinal hernia repair","volume":"14","year":"2018","journal-title":"J Pediatr Urol"},{"key":"bib25-20230923","doi-asserted-by":"crossref","first-page":"320","DOI":"10.1016\/j.jss.2017.06.029","article-title":"Surgical tray optimization as a simple means to decrease perioperative costs","volume":"220","year":"2017","journal-title":"J Surg Res"},{"key":"bib26-20230923","doi-asserted-by":"crossref","first-page":"153.e1","DOI":"10.1016\/j.jpurol.2019.01.013","article-title":"Decreasing operating room costs via reduction of surgical instruments","volume":"15","year":"2019","journal-title":"J Pediatr Urol"},{"key":"bib27-20230923","doi-asserted-by":"crossref","first-page":"e14338","DOI":"10.1097\/MD.0000000000014338","article-title":"Implementing a perioperative efficiency initiative for orthopedic surgery instrumentation at an academic center: a comparative before-and-after study","volume":"98","year":"2019","journal-title":"Medicine (Baltimore)"},{"key":"bib28-20230923","doi-asserted-by":"crossref","first-page":"12","DOI":"10.1186\/s40942-020-00215-2","article-title":"Reducing instruments in a vitrectomy surgical tray: cost savings and results from a major academic hospital","volume":"6","year":"2020","journal-title":"Int J Retina Vitreous"},{"key":"bib29-20230923","doi-asserted-by":"crossref","first-page":"963","DOI":"10.1007\/s00132-019-03803-9","article-title":"Process optimization in total knee arthoplasty procedures: impact of size-specific instrument sets on costs and revenue","volume":"48","year":"2019","journal-title":"Orthopade"},{"key":"bib30-20230923","doi-asserted-by":"crossref","first-page":"1104","DOI":"10.1097\/DCR.0000000000000463","article-title":"A model of cost reduction and standardization: improved cost savings while maintaining the quality of care","volume":"58","year":"2015","journal-title":"Dis Colon Rectum"},{"key":"bib31-20230923","doi-asserted-by":"crossref","first-page":"2435","DOI":"10.1016\/j.jpedsurg.2020.05.010","article-title":"Surgical tray reduction for cost saving in pediatric surgical cases: a qualitative systematic review","volume":"55","year":"2020","journal-title":"J Pediatr Surg"},{"key":"bib32-20230923","doi-asserted-by":"crossref","first-page":"268","DOI":"10.1007\/s00464-003-9232-4","article-title":"Comparison of economic and environmental impacts between disposable and reusable instruments used for laparoscopic cholecystectomy","volume":"19","year":"2005","journal-title":"Surg Endosc"},{"key":"bib33-20230923","doi-asserted-by":"crossref","first-page":"837","DOI":"10.1016\/j.ajic.2017.11.031","article-title":"A prospective analysis of clinical detection of defective wrapping by operating room staff","volume":"46","year":"2018","journal-title":"Am J Infect Control"},{"key":"bib34-20230923","doi-asserted-by":"crossref","first-page":"371","DOI":"10.1016\/j.jss.2016.04.054","article-title":"Efficiency improvement in the operating room","volume":"204","year":"2016","journal-title":"J Surg Res"},{"key":"bib35-20230923","doi-asserted-by":"crossref","first-page":"159","DOI":"10.1016\/j.surg.2005.07.037","article-title":"A prospective study of patient safety in the operating room","volume":"139","year":"2006","journal-title":"Surgery"},{"issue":"suppl 4","key":"bib36-20230923","first-page":"S186","article-title":"Operative costs, reasons for operative waste, and vendor credit replacement in spinal surgery","volume":"6","year":"2015","journal-title":"Surg Neurol Int"},{"key":"bib37-20230923","doi-asserted-by":"crossref","first-page":"e33","DOI":"10.2106\/JBJS.16.00271","article-title":"\u201cRed-Yellow-Green\u201d: effect of an initiative to guide surgeon choice of orthopaedic implants","volume":"99","year":"2017","journal-title":"J Bone Joint Surg Am"}],"container-title":["Annals of Plastic Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/SAP.0000000000002913","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,9,23]],"date-time":"2023-09-23T05:28:02Z","timestamp":1695446882000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/SAP.0000000000002913"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,6]]},"references-count":35,"journal-issue":{"issue":"6S","published-print":{"date-parts":[[2021]]}},"URL":"https:\/\/doi.org\/10.1097\/sap.0000000000002913","relation":{},"ISSN":["1536-3708","0148-7043"],"issn-type":[{"value":"1536-3708","type":"electronic"},{"value":"0148-7043","type":"print"}],"subject":[],"published":{"date-parts":[[2021,6]]}}}