{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,14]],"date-time":"2026-11-14T04:59:30Z","timestamp":1794632370439,"version":"4.9.1"},"reference-count":11,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"6S","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Ann Plast Surg"],"published-print":{"date-parts":[[2023,6]]},"abstract":"<jats:sec>\n            <jats:title>Background<\/jats:title>\n            <jats:p>Implant-based reconstruction remains the most common form of postmastectomy breast reconstruction. With ever-evolving device characteristics, including the advent of high-profile, cohesive, fifth-generation implants, the incidence of anterior-posterior flipping of implants is presenting a new challenge. Patient and device characteristics associated with this phenomenon have yet to be fully elucidated.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods<\/jats:title>\n            <jats:p>Patients who underwent nipple- or skin-sparing mastectomy with subsequent 2-stage or direct-to-implant reconstruction with smooth implants between 2015 and 2021 were retrospectively identified and stratified by incidence of implant flipping. Patient, procedural, and device characteristics were evaluated.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results<\/jats:title>\n            <jats:p>Within 165 patients (255 reconstructed breasts), 14 cases of implant flipping were identified (flip rate 5.5%). All flips occurred in patients with cohesive implants (odds ratio [OR], 87.0; <jats:italic toggle=\"yes\">P<\/jats:italic> = 0.002). On univariate analysis, extra full implant profile (OR, 11.2; <jats:italic toggle=\"yes\">P<\/jats:italic> &lt; 0.001) and use of a smooth tissue expander for 2-stage reconstruction (OR, 4.1; <jats:italic toggle=\"yes\">P<\/jats:italic> = 0.03) were associated with flipping. Implants that flipped were larger than those that did not (652.5 \u00b1 117.8 vs 540.1 \u00b1 171.0 mL, <jats:italic toggle=\"yes\">P<\/jats:italic> = 0.0004). Prepectoral implant placement (OR, 2.7; <jats:italic toggle=\"yes\">P<\/jats:italic> = 0.08) and direct-to-implant method (OR, 3.17; <jats:italic toggle=\"yes\">P<\/jats:italic> = 0.07) trended toward association, but this effect was not significant. Patient BMI, weight fluctuation during the reconstructive course, mastectomy weight, AlloDerm use, and history of seroma or periprosthetic infection were not associated with flipping.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusion<\/jats:title>\n            <jats:p>Patients who receive a highly cohesive, high profile, larger implant are at increased risk for implant flipping. In addition, patients who receive a smooth tissue expander are more likely to experience flipping of their subsequent implant, compared with those who had textured tissue expanders. These characteristics warrant consideration during device selection to minimize discomfort, aesthetic deformity, and the need for reoperation.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/sap.0000000000003515","type":"journal-article","created":{"date-parts":[[2023,3,28]],"date-time":"2023-03-28T12:09:25Z","timestamp":1680005365000},"page":"S509-S514","source":"Crossref","is-referenced-by-count":5,"title":["A Critical Analysis of Factors Associated With Anteroposterior Implant Flipping in Immediate Breast Reconstruction"],"prefix":"10.1097","volume":"90","author":[{"given":"Kayla E.","family":"Leibl","sequence":"first","affiliation":[{"name":"Division of Plastic and Reconstructive Surgery, Department of Surgery, Montefiore Medical Center\/Albert Einstein College of Medicine, Bronx, NY"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lyahn K.","family":"Hwang","sequence":"additional","affiliation":[{"name":"Division of Plastic and Reconstructive Surgery, Department of Surgery, Montefiore Medical Center\/Albert Einstein College of Medicine, Bronx, NY"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Cassidy","family":"Anderson","sequence":"additional","affiliation":[{"name":"Division of Plastic and Reconstructive Surgery, Department of Surgery, Montefiore Medical Center\/Albert Einstein College of Medicine, Bronx, NY"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Katie E.","family":"Weichman","sequence":"additional","affiliation":[{"name":"Hansj\u00f6rg Wyss Department of Plastic Surgery, New York University School of Medicine, New York, NY"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2023,3,17]]},"reference":[{"key":"bib1-20230703","doi-asserted-by":"crossref","first-page":"1367","DOI":"10.1097\/PRS.0000000000003387","article-title":"Is rotation a concern with anatomical breast implants? A statistical analysis of factors predisposing to rotation","volume":"139","year":"2017","journal-title":"Plast Reconstr Surg"},{"key":"bib2-20230703","doi-asserted-by":"crossref","first-page":"2555","DOI":"10.1097\/00006534-200206000-00060","article-title":"Breast deformity caused by anatomical or teardrop implant rotation","volume":"109","year":"2002","journal-title":"Plast Reconstr Surg"},{"key":"bib3-20230703","doi-asserted-by":"crossref","first-page":"7S","DOI":"10.1097\/PRS.0000000000005959","article-title":"The science of cohesivity and elements of form stability","volume":"144","year":"2019","journal-title":"Plast Reconstr Surg"},{"key":"bib4-20230703","doi-asserted-by":"crossref","first-page":"264","DOI":"10.1093\/asj\/sjy103","article-title":"Physical properties of silicone gel breast implants","volume":"39","year":"2019","journal-title":"Aesthet Surg J"},{"key":"bib6-20230703","article-title":"Johnson and Johnson","journal-title":"Fortschr Med"},{"key":"bib7-20230703","doi-asserted-by":"crossref","first-page":"125","DOI":"10.1007\/s00266-010-9557-z","article-title":"Back-to-front flipping of implants following augmentation mammoplasty and the role of physical characteristics in a round cohesive gel silicone breast implant: retrospective analysis of 3458 breast implants by a single surgeon","volume":"35","year":"2011","journal-title":"Aesthet Plast Surg"},{"key":"bib8-20230703","first-page":"3321","article-title":"Cohesive round implants and the risk of implant flipping","volume":"8","year":"2022","journal-title":"Plast Reconstr Surg Glob Open"},{"key":"bib9-20230703","doi-asserted-by":"crossref","first-page":"1381","DOI":"10.1097\/PRS.0b013e31824ecbf0","article-title":"Mentor contour profile gel implants: clinical outcomes at 6 years","volume":"129","year":"2012","journal-title":"Plast Reconstr Surg"},{"key":"bib10-20230703","doi-asserted-by":"crossref","first-page":"1142","DOI":"10.1097\/PRS.0000000000003846","article-title":"Mentor contour profile gel implants: clinical outcomes at 10 years","volume":"140","year":"2017","journal-title":"Plast Reconstr Surg"},{"key":"bib11-20230703","doi-asserted-by":"crossref","first-page":"940e","DOI":"10.1097\/PRS.0000000000007991","article-title":"Breast augmentation with microtextured anatomical implants in 653 women: Indications and risk of rotation","volume":"147","year":"2021","journal-title":"Plast Reconstr Surg"},{"key":"bib12-20230703","doi-asserted-by":"crossref","first-page":"348","DOI":"10.1007\/s00266-004-0068-7","article-title":"Rotation of anatomic prostheses: a possible cause of breast deformity","volume":"28","year":"2004","journal-title":"Aesthet Plast Surg"}],"container-title":["Annals of Plastic Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/SAP.0000000000003515","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,7,3]],"date-time":"2023-07-03T20:00:36Z","timestamp":1688414436000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/SAP.0000000000003515"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,3,17]]},"references-count":11,"journal-issue":{"issue":"6S","published-print":{"date-parts":[[2023]]}},"URL":"https:\/\/doi.org\/10.1097\/sap.0000000000003515","relation":{},"ISSN":["1536-3708","0148-7043"],"issn-type":[{"value":"1536-3708","type":"electronic"},{"value":"0148-7043","type":"print"}],"subject":[],"published":{"date-parts":[[2023,3,17]]}}}