{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,30]],"date-time":"2026-06-30T08:37:16Z","timestamp":1782808636780,"version":"3.54.5"},"reference-count":15,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"3","license":[{"start":{"date-parts":[[2024,7,30]],"date-time":"2024-07-30T00:00:00Z","timestamp":1722297600000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":["Ann Plast Surg"],"published-print":{"date-parts":[[2024,9]]},"abstract":"<jats:sec>\n            <jats:title>Objective<\/jats:title>\n            <jats:p>Severe hand electrical injuries often occur in functional areas such as joints; the repair requires attention to both appearance and function due to the visibility of the hand. This study aimed to present the clinical experience of successfully repairing hand electrical injuries using improved forearm venous flaps.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods<\/jats:title>\n            <jats:p>From 2020 to 2022, 15 cases of severe hand electrical injuries were diagnosed, including 10 males and 5 females. Among them, 6 cases were repaired in the first web space, 4 in the thumb, 3 in the index finger, 2 in the middle finger, 2 in the ring finger, and 2 in the little finger. The size of venous flaps ranged from 2.0 cm \u00d7 1.8 cm to 12 cm \u00d7 4.0 cm. All patients underwent repair using improved forearm venous flaps. The follow-up period ranged from 5 to 8 months.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results<\/jats:title>\n            <jats:p>All flaps survived without serious complications. All patients were satisfied with the postoperative aesthetics and function of their hands.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusion<\/jats:title>\n            <jats:p>The improved forearm venous flap is a simple and reliable method for repairing hand electrical injuries.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/sap.0000000000004027","type":"journal-article","created":{"date-parts":[[2024,7,30]],"date-time":"2024-07-30T15:03:50Z","timestamp":1722351830000},"page":"312-318","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":2,"title":["Treatment of Patients With Electrical Injury by Using Modified Forearm Venous Flap"],"prefix":"10.1097","volume":"93","author":[{"given":"Chenglan","family":"Yang","sequence":"first","affiliation":[{"name":"Department of Burns and Plastic Surgery, Affiliated Hospital of Zunyi Medical University"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9744-2176","authenticated-orcid":false,"given":"Qi","family":"Wang","sequence":"additional","affiliation":[{"name":"Department of Burns and Plastic Surgery, Affiliated Hospital of Zunyi Medical University"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xueqin","family":"Zeng","sequence":"additional","affiliation":[{"name":"Department of Burns and Plastic Surgery, Affiliated Hospital of Zunyi Medical University"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jian","family":"Zhou","sequence":"additional","affiliation":[{"name":"Department of Burns and Plastic Surgery, Affiliated Hospital of Zunyi Medical University"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lingli","family":"Jiang","sequence":"additional","affiliation":[{"name":"Department of Burns and Plastic Surgery, Affiliated Hospital of Zunyi Medical University"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Peng","family":"Hu","sequence":"additional","affiliation":[{"name":"Department of Burns and Plastic Surgery, Affiliated Hospital of Zunyi Medical University"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zairong","family":"Wei","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2024,7,30]]},"reference":[{"key":"bib1-20250616","doi-asserted-by":"crossref","first-page":"e568","DOI":"10.1097\/BCR.0000000000000422","article-title":"Comparison of the results of early flap coverage with late flap coverage in high-voltage electrical injury","volume":"38","year":"2017","journal-title":"J Burn Care Res"},{"key":"bib2-20250616","doi-asserted-by":"crossref","first-page":"855","DOI":"10.2147\/TCRM.S131815","article-title":"Reconstruction of fingers after electrical injury using lateral tarsal artery flap","volume":"13","year":"2017","journal-title":"Ther Clin Risk Manag"},{"key":"bib3-20250616","doi-asserted-by":"crossref","first-page":"328","DOI":"10.1097\/00006534-198103000-00009","article-title":"Flaps nourished by arterial inflow through the venous system: an experimental investigation","volume":"67","year":"1981","journal-title":"Plast Reconstr Surg"},{"key":"bib4-20250616","doi-asserted-by":"crossref","first-page":"1389","DOI":"10.1016\/j.bjps.2016.05.013","article-title":"The position of 'shunt restriction' along an arterialized vein affects venous congestion and flap perfusion of an arterialized venous flap","volume":"69","year":"2016","journal-title":"J Plast Reconstr Aesthet Surg"},{"key":"bib5-20250616","doi-asserted-by":"crossref","first-page":"116","DOI":"10.1016\/j.jpra.2022.02.010","article-title":"The use of indocyanine green angiography in arterialized-venous free flaps: case report and insight into flap vascular physiology","volume":"32","year":"2022","journal-title":"JPRAS Open"},{"key":"bib6-20250616","doi-asserted-by":"crossref","first-page":"21","DOI":"10.1097\/00000637-200201000-00003","article-title":"Reliability of primary vein grafts in lower extremity free tissue transfers","volume":"48","year":"2002","journal-title":"Ann Plast Surg"},{"key":"bib7-20250616","doi-asserted-by":"crossref","first-page":"1065","DOI":"10.3390\/medicina58081065","article-title":"Retrograde free venous flaps for extremity reconstruction: a roadmap","volume":"58","year":"2022","journal-title":"Medicina (Kaunas)"},{"key":"bib8-20250616","doi-asserted-by":"crossref","first-page":"554","DOI":"10.1016\/0007-1226(94)90139-2","article-title":"Direct monitoring of the microcirculation in experimental venous flaps with afferent arteriovenous fistulas","volume":"47","year":"1994","journal-title":"Br J Plast Surg"},{"key":"bib9-20250616","doi-asserted-by":"crossref","first-page":"e79608","DOI":"10.1371\/journal.pone.0079608","article-title":"The effect of hemodynamic remodeling on the survival of arterialized venous flaps","volume":"8","year":"2013","journal-title":"PLoS One"},{"key":"bib10-20250616","doi-asserted-by":"crossref","first-page":"149","DOI":"10.1016\/0007-1226(87)90187-1","article-title":"Island flaps with an exclusively venous pedicle. A report of eleven cases and a preliminary haemodynamic study","volume":"40","year":"1987","journal-title":"Br J Plast Surg"},{"key":"bib11-20250616","doi-asserted-by":"crossref","first-page":"88","DOI":"10.1097\/00006534-198501000-00020","article-title":"Experimental studies in the survival of venous island flaps without arterial inflow","volume":"75","year":"1985","journal-title":"Plast Reconstr Surg"},{"key":"bib12-20250616","doi-asserted-by":"crossref","first-page":"e3488","DOI":"10.1097\/GOX.0000000000003488","article-title":"The pediatric arterialized venous flow-through flap","volume":"9","year":"2021","journal-title":"Plast Reconstr Surg Glob Open"},{"key":"bib13-20250616","doi-asserted-by":"crossref","first-page":"444","DOI":"10.1097\/SAP.0000000000001487","article-title":"Medial plantar venous flap: classic donor site modification for hand defects","volume":"81","year":"2018","journal-title":"Ann Plast Surg"},{"key":"bib14-20250616","doi-asserted-by":"crossref","first-page":"292","DOI":"10.1097\/SAP.0000000000001633","article-title":"Application of concatenated arterialized venous flaps in finger reconstruction","volume":"82","year":"2019","journal-title":"Ann Plast Surg"},{"key":"bib15-20250616","first-page":"399","article-title":"The shunt-restricted arterialized venous flap for hand\/digit reconstruction: enhanced perfusion, decreased congestion, and improved reliability","volume":"69","year":"2010","journal-title":"J Trauma"}],"container-title":["Annals of Plastic Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/SAP.0000000000004027","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,6,16]],"date-time":"2025-06-16T22:07:30Z","timestamp":1750111650000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/SAP.0000000000004027"}},"subtitle":["Retrospective Case Series Study"],"short-title":[],"issued":{"date-parts":[[2024,7,30]]},"references-count":15,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2024]]}},"URL":"https:\/\/doi.org\/10.1097\/sap.0000000000004027","relation":{},"ISSN":["1536-3708","0148-7043"],"issn-type":[{"value":"1536-3708","type":"electronic"},{"value":"0148-7043","type":"print"}],"subject":[],"published":{"date-parts":[[2024,7,30]]}}}