{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,1,22]],"date-time":"2025-01-22T21:40:30Z","timestamp":1737582030179,"version":"3.33.0"},"reference-count":25,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"2","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":["Ann Plast Surg"],"published-print":{"date-parts":[[2025,2]]},"abstract":"<jats:sec>\n            <jats:title>Background<\/jats:title>\n            <jats:p>Extra-articular but severely comminuted distal basal fractures of the proximal phalanx (PP) are rarely reported. Therefore, the aim of this study was to achieve proper union and desirable outcomes using low-profile locking plates\/screws. We introduced our own surgical approach and reported the clinical\/radiographic outcomes via retrospective case series.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods<\/jats:title>\n            <jats:p>Thirty-eight patients diagnosed with comminuted basal fracture of the PP were admitted between January 2014 and December 2020. Nineteen of these patients met the inclusion\/exclusion criteria and were investigated in this retrospective study. Focusing only on preventing the volar tilt\/collapse of the articular cartilage from the vertical position due to comminuted metaphysis, such as the \u201cbuttress concept by locking plate,\u201d the defect was filled with bone grafts. Meticulous repair of the incised central tendon effectively stabilized it by tightening the sagittal band and capsule of the metacarpophalangeal joint. It also acted as an envelope with proper sealing to minimize the loss of grafted bone materials.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results<\/jats:title>\n            <jats:p>Among the 19 patients, the mean patient age was 58.94 years, and the male\/female ratio was 6:13. The mean follow-up period was 3.15 years, and the mean BMD was \u22120.15. Complete union was achieved after a mean of 9.63 weeks, without complications requiring secondary intervention. Two patients complained of skin lesion associated with PDS suture material, but this material spontaneously resolved by 4 weeks postoperatively. The mean extension lag at the proximal interphalangeal joint was 3.68 degrees, and the total active range of motion (TAM) was 256.38 degrees. Among the 19 patients, 6 were categorized as having a \u201cgood\u201d modified Belsky classification, and the other patients all had an \u201cexcellent\u201d classification. The mean articular-dorsal cortex angle was 85 \u00b1 3.33 degrees at the final follow-up, which was slightly less than the normal value with statistical difference (<jats:italic toggle=\"yes\">P<\/jats:italic> &lt; 0.05); however, it did not correlate with the TAM statistically (<jats:italic toggle=\"yes\">r<\/jats:italic> = 0.126, <jats:italic toggle=\"yes\">P<\/jats:italic> = 0.608). Clinical outcomes were also satisfactorily evaluated using the VAS and DASH scores.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusions<\/jats:title>\n            <jats:p>A low-profile locking plate is an effective option for extra-articular, severely comminuted basal fractures of the PP using the buttress concept in terms of clinical outcomes, such as finger movement and proper union.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/sap.0000000000004181","type":"journal-article","created":{"date-parts":[[2025,1,2]],"date-time":"2025-01-02T13:00:49Z","timestamp":1735822849000},"page":"169-176","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":0,"title":["A Novel Technique With Buttress Plating for Comminuted Base Fractures of the Proximal Phalanx"],"prefix":"10.1097","volume":"94","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-1663-406X","authenticated-orcid":false,"given":"Soo Min","family":"Cha","sequence":"first","affiliation":[{"name":"Department of Orthopedic Surgery, Regional Rheumatoid and Degenerative Arthritis Center, Chungnam National University Hospital, Chungnam National University School of Medicine, Daejeon"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jae Hwi","family":"Nho","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, Soonchunhyang University Seoul Hospital, Soonchunhyang University College of Medicine, Seoul"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"In Ho","family":"Ga","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, W Hospital, Daegu"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yong Hwan","family":"Kim","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, Duson Hospital, Ansan, Korea."}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","published-online":{"date-parts":[[2024,12,10]]},"reference":[{"key":"bib1-20250122","doi-asserted-by":"crossref","first-page":"908","DOI":"10.1053\/jhsu.2001.26322","article-title":"The frequency and epidemiology of hand and forearm fractures in the United States","volume":"26","year":"2001","journal-title":"J Hand Surg Am"},{"key":"bib2-20250122","doi-asserted-by":"crossref","first-page":"491","DOI":"10.1016\/S0266-7681(03)00103-7","article-title":"Prevalence and distribution of hand fractures","volume":"28","year":"2003","journal-title":"J Hand Surg Br"},{"key":"bib3-20250122","doi-asserted-by":"crossref","first-page":"889","DOI":"10.1016\/j.jhsa.2012.02.017","article-title":"Extra-articular fractures of the proximal phalanges of the fingers: a comparison of 2 methods of functional, conservative treatment","volume":"37","year":"2012","journal-title":"J Hand Surg Am"},{"key":"bib4-20250122","first-page":"e348","article-title":"Ten-year results using a dynamic treatment for proximal phalangeal fractures of the hands","volume":"36","year":"2013","journal-title":"Orthopedics"},{"key":"bib5-20250122","first-page":"23","article-title":"Conservative management of difficult phalangeal fractures","volume":"214","year":"1987","journal-title":"Clin Orthop Relat Res"},{"key":"bib6-20250122","doi-asserted-by":"crossref","first-page":"1342","DOI":"10.1016\/j.jhsa.2012.04.019","article-title":"Percutaneous pinning of fractures in the proximal third of the proximal phalanx: complications and outcomes","volume":"37","year":"2012","journal-title":"J Hand Surg Am"},{"key":"bib7-20250122","doi-asserted-by":"crossref","first-page":"1524","DOI":"10.1016\/j.jhsa.2014.05.008","article-title":"Outcomes of closed reduction and periarticular pinning of base and shaft fractures of the proximal phalanx","volume":"39","year":"2014","journal-title":"J Hand Surg Am"},{"key":"bib8-20250122","doi-asserted-by":"crossref","first-page":"506","DOI":"10.1177\/1753193418766973","article-title":"Fractures at the junction of diaphysis and metaphysis of the proximal phalanges in adults","volume":"43","year":"2018","journal-title":"J Hand Surg Eur Vol"},{"key":"bib9-20250122","doi-asserted-by":"crossref","first-page":"537","DOI":"10.1016\/j.injury.2020.09.046","article-title":"\u201cBi-cortical\u201d periarticular K-wire fixation for displaced unstable transverse extra-articular fractures of the base of the proximal phalanx of the fingers","volume":"52","year":"2021","journal-title":"Injury"},{"key":"bib10-20250122","doi-asserted-by":"crossref","first-page":"110","DOI":"10.1016\/j.ijscr.2017.08.006","article-title":"Closed reduction and percutaneous \u201cperiarticular\u201d single K-wire fixation for displaced unstable transverse fractures of the proximal phalanx in elderly osteoporotic women: a case series of five patients","volume":"39","year":"2017","journal-title":"Int J Surg Case Rep"},{"key":"bib11-20250122","doi-asserted-by":"crossref","first-page":"439","DOI":"10.1007\/s00402-015-2155-4","article-title":"Plate fixation of extra-articular fractures of the proximal phalanx: do new implants cause less problems?","volume":"135","year":"2015","journal-title":"Arch Orthop Trauma Surg"},{"key":"bib12-20250122","doi-asserted-by":"crossref","first-page":"35","DOI":"10.1142\/S021881041750006X","article-title":"Trans-metacarpal screw fixation for extra-articular proximal phalangeal base fractures","volume":"22","year":"2017","journal-title":"J Hand Surg Asian Pac Vol"},{"key":"bib13-20250122","doi-asserted-by":"crossref","first-page":"164","DOI":"10.5014\/ajot.41.3.164","article-title":"Tendon gliding exercises","volume":"41","year":"1987","journal-title":"Am J Occup Ther"},{"key":"bib14-20250122","doi-asserted-by":"crossref","first-page":"725","DOI":"10.1016\/S0363-5023(84)80023-4","article-title":"Closed reduction and internal fixation of proximal phalangeal fractures","volume":"9","year":"1984","journal-title":"J Hand Surg Am"},{"key":"bib15-20250122","doi-asserted-by":"crossref","first-page":"420","DOI":"10.1037\/0033-2909.86.2.420","article-title":"Intraclass correlations: uses in assessing rater reliability","volume":"86","year":"1979","journal-title":"Psychol Bull"},{"key":"bib16-20250122","doi-asserted-by":"crossref","first-page":"613","DOI":"10.1177\/001316447303300309","article-title":"The equivalence of weighted kappa and the intraclass correlation coefficient as measures of reliability","volume":"33","year":"1973","journal-title":"Educ Psychol Meas"},{"key":"bib17-20250122","doi-asserted-by":"crossref","first-page":"49","DOI":"10.1142\/S2424835524500085","article-title":"Extra-articular base fractures of the proximal phalanx in adults: a systematic review","volume":"29","year":"2024","journal-title":"J Hand Surg Asian Pac Vol"},{"key":"bib18-20250122","doi-asserted-by":"crossref","first-page":"2252","DOI":"10.1016\/j.injury.2019.10.018","article-title":"Comparison of low-profile locking plate fixation versus antegrade intramedullary nailing for unstable metacarpal shaft fractures\u2014a prospective comparative study","volume":"50","year":"2019","journal-title":"Injury"},{"key":"bib19-20250122","doi-asserted-by":"crossref","first-page":"1104","DOI":"10.1111\/os.13660","article-title":"A novel locking buttress plate designed for simultaneous medial and posterolateral Tibial plateau fractures: concept and comparative finite element analysis","volume":"15","year":"2023","journal-title":"Orthop Surg"},{"key":"bib20-20250122","doi-asserted-by":"crossref","first-page":"363","DOI":"10.1016\/j.ocl.2015.02.005","article-title":"Definitive fixation of tibial plateau fractures","volume":"46","year":"2015","journal-title":"Orthop Clin North Am"},{"key":"bib21-20250122","doi-asserted-by":"crossref","first-page":"883","DOI":"10.1016\/j.otsr.2018.04.009","article-title":"Double-tiered subchondral support fixation with optimal distal dorsal cortical distance using a variable-angle volar locking-plate system for distal radius fracture in the elderly","volume":"104","year":"2018","journal-title":"Orthop Traumatol Surg Res"},{"key":"bib22-20250122","doi-asserted-by":"crossref","first-page":"271","DOI":"10.1007\/s10195-014-0292-0","article-title":"Variable-angle locking plate with or without double-tiered subchondral support procedure in the treatment of intra-articular distal radius fracture","volume":"15","year":"2014","journal-title":"J Orthop Traumatol"},{"key":"bib23-20250122","doi-asserted-by":"crossref","first-page":"841","DOI":"10.1097\/01.ta.0000214887.31745.c4","article-title":"Complications after plate fixation of phalangeal fractures","volume":"60","year":"2006","journal-title":"J Trauma"},{"key":"bib24-20250122","doi-asserted-by":"crossref","first-page":"827","DOI":"10.1016\/S0363-5023(98)80157-3","article-title":"Complications and range of motion following plate fixation of metacarpal and phalangeal fractures","volume":"23","year":"1998","journal-title":"J Hand Surg Am"},{"key":"bib25-20250122","doi-asserted-by":"crossref","first-page":"113","DOI":"10.1016\/S0363-5023(10)80023-1","article-title":"Unstable phalangeal fractures: treatment by A.O. screw and plate fixation","volume":"16","year":"1991","journal-title":"J Hand Surg Am"}],"container-title":["Annals of Plastic Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/SAP.0000000000004181","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,1,22]],"date-time":"2025-01-22T21:00:59Z","timestamp":1737579659000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/SAP.0000000000004181"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,12,10]]},"references-count":25,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2025]]}},"URL":"https:\/\/doi.org\/10.1097\/sap.0000000000004181","relation":{},"ISSN":["1536-3708","0148-7043"],"issn-type":[{"type":"electronic","value":"1536-3708"},{"type":"print","value":"0148-7043"}],"subject":[],"published":{"date-parts":[[2024,12,10]]}}}