{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,4]],"date-time":"2026-08-04T16:13:58Z","timestamp":1785860038374,"version":"3.56.0"},"reference-count":18,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"4S","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":["Ann Plast Surg"],"published-print":{"date-parts":[[2025,4]]},"abstract":"<jats:sec>\n                    <jats:title>Introduction<\/jats:title>\n                    <jats:p>Use of textured breast implants and tissue expanders has markedly declined due to their association with BIA-ALCL. Alternatives for stabilization such as ADM are costly, and suture tabs for expander anchoring can cause pain and anchor point failure with resultant implant malposition. This study aims to explore an alternative approach using Polyglactin 910 mesh (Vicryl woven mesh) to wrap and stabilize smooth-surface implants.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>Miniature 2-mL breast implants were manufactured using polydimethylsiloxane. Vicryl woven mesh was used to wrap smooth implants, with comparison groups consisting of smooth and textured implants nonwrapped implants. Six sterilized implants from each group were implanted into subcutaneous pockets on the dorsa of Sprague-Dawley rats (n = 2 per rat). Animals were sacrificed after 4 and 12 weeks, and implant-capsule units were explanted for evaluation of positional stability, histology, and SEM.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>Vicryl-wrapped implants rotated 49 degrees less than smooth implants at 4 weeks and 76 degrees less at 12 weeks. Histology demonstrated partially dissolved Vicryl mesh in the wrapped group capsule at 4 weeks, with complete mesh degradation by 12 weeks. There were no significant differences in capsule thickness and collagen fiber density (percent area) between smooth and wrapped conditions. Although histologically similar to nonwrapped smooth implants, on higher magnification, SEM demonstrated a regular pattern of undulating microscopic projections in wrapped implant capsules, recapitulating the woven patterns of Vicryl mesh; smooth implant capsules were largely featureless.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>Implants wrapped with fast-absorbing Vicryl mesh demonstrated improved stability, likely due to capsular microtopographic changes (seen only on SEM) induced by the presence of Vicryl mesh, resulting in increased frictional force between the implant surface and surrounding tissues. This study highlights the potential for using Vicryl mesh as an affordable temporary scaffold for stabilizing smooth implants and tissue expanders.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1097\/sap.0000000000004292","type":"journal-article","created":{"date-parts":[[2025,4,1]],"date-time":"2025-04-01T12:41:05Z","timestamp":1743511265000},"page":"S359-S363","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":0,"title":["Polyglactin 910 (Vicryl)\u2013Wrapped Implants to Improve Implant Stability"],"prefix":"10.1097","volume":"94","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-8008-5881","authenticated-orcid":false,"given":"Tim Y.","family":"Li","sequence":"first","affiliation":[{"name":"Laboratory of Bioregenerative Medicine and Surgery, Department of Surgery, Weill Cornell Medicine, New York"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hector F.","family":"Salazar","sequence":"additional","affiliation":[{"name":"Laboratory of Bioregenerative Medicine and Surgery, Department of Surgery, Weill Cornell Medicine, New York"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sophia","family":"Salingaros","sequence":"additional","affiliation":[{"name":"Laboratory of Bioregenerative Medicine and Surgery, Department of Surgery, Weill Cornell Medicine, New York"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jini","family":"Jeon","sequence":"additional","affiliation":[{"name":"Laboratory of Bioregenerative Medicine and Surgery, Department of Surgery, Weill Cornell Medicine, New York"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Riley D.","family":"Mayne","sequence":"additional","affiliation":[{"name":"Laboratory of Bioregenerative Medicine and Surgery, Department of Surgery, Weill Cornell Medicine, New York"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xue","family":"Dong","sequence":"additional","affiliation":[{"name":"Laboratory of Bioregenerative Medicine and Surgery, Department of Surgery, Weill Cornell Medicine, New York"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jason A.","family":"Spector","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"bib1-20250401","doi-asserted-by":"crossref","first-page":"27","DOI":"10.1080\/17434440.2023.2288911","article-title":"The current use of tissue expanders in breast reconstruction: device design, features, and technical considerations","volume":"21","year":"2024","journal-title":"Expert Rev Med Devices"},{"key":"bib3-20250401","doi-asserted-by":"crossref","first-page":"622","DOI":"10.1097\/SAP.0000000000003330","article-title":"Outcomes analysis of textured versus smooth tissue expanders in breast reconstruction","volume":"89","year":"2022","journal-title":"Ann Plast Surg"},{"key":"bib4-20250401","doi-asserted-by":"crossref","first-page":"225","DOI":"10.1097\/00000637-199403000-00001","article-title":"Smooth versus textured expander implants: a double-blind study of capsule quality and discomfort in simultaneous bilateral breast reconstruction patients","volume":"32","year":"1994","journal-title":"Ann Plast Surg"},{"key":"bib5-20250401","doi-asserted-by":"crossref","first-page":"e0116071","DOI":"10.1371\/journal.pone.0116071","article-title":"Comparison of the postoperative incidence rate of capsular contracture among different breast implants: a cumulative meta-analysis","volume":"10","year":"2015","journal-title":"PloS One"},{"key":"bib7-20250401","first-page":"015013","article-title":"A positionally stable anatomic smooth breast implant","volume":"20","year":"2024","journal-title":"Biomed Mater"},{"key":"bib8-20250401","doi-asserted-by":"crossref","first-page":"256e","DOI":"10.1097\/01.prs.0000438057.44505.3c","article-title":"Analyzing implant movement with tabbed and nontabbed expanders through the process of two-stage breast reconstruction","volume":"133","year":"2014","journal-title":"Plast Reconstr Surg"},{"key":"bib9-20250401","doi-asserted-by":"crossref","first-page":"57","DOI":"10.5999\/aps.2014.41.1.57","article-title":"Tabbed tissue expanders improve breast symmetry scores in breast reconstruction","volume":"41","year":"2014","journal-title":"Arch Plast Surg"},{"key":"bib10-20250401","doi-asserted-by":"crossref","first-page":"e2466","DOI":"10.1097\/GOX.0000000000002466","article-title":"Breast implant surfaces and their impact on current practices: where we are now and where are we going?","volume":"7","year":"2019","journal-title":"Plast Reconstr Surg Glob Open"},{"key":"bib11-20250401","doi-asserted-by":"crossref","first-page":"1022","DOI":"10.1097\/00006534-199206000-00003","article-title":"Eighty-four consecutive breast reconstructions using a textured silicone tissue expander","volume":"89","year":"1992","journal-title":"Plast Reconstr Surg"},{"key":"bib12-20250401","doi-asserted-by":"crossref","first-page":"1711","DOI":"10.1097\/PRS.0b013e3181ef900c","article-title":"The use of human acellular dermal matrix for the correction of secondary deformities after breast augmentation: results and costs","volume":"126","year":"2010","journal-title":"Plast Reconstr Surg"},{"key":"bib13-20250401","doi-asserted-by":"crossref","first-page":"346","DOI":"10.1097\/SAP.0b013e31823f3cd9","article-title":"A systematic review and meta-analysis of complications associated with acellular dermal matrix-assisted breast reconstruction","volume":"68","year":"2012","journal-title":"Ann Plast Surg"},{"key":"bib14-20250401","doi-asserted-by":"crossref","first-page":"429","DOI":"10.1097\/PRS.0b013e3181c82d90","article-title":"Implant-based breast reconstruction using acellular dermal matrix and the risk of postoperative complications","volume":"125","year":"2010","journal-title":"Plast Reconstr Surg"},{"key":"bib15-20250401","doi-asserted-by":"crossref","first-page":"537","DOI":"10.1016\/j.asjsur.2017.08.001","article-title":"Pros and cons of immediate Vicryl mesh insertion after lumpectomy","volume":"41","year":"2018","journal-title":"Asian J Surg"},{"key":"bib16-20250401","doi-asserted-by":"crossref","first-page":"S707","DOI":"10.1097\/SAP.0000000000003483","article-title":"Augmenting breast implant research: accessible methods for fabricating miniature smooth and textured breast implants in a laboratory setting","volume":"90","year":"2023","journal-title":"Ann Plast Surg"},{"key":"bib17-20250401","doi-asserted-by":"crossref","first-page":"516","DOI":"10.1097\/SAP.0b013e318217fb21","article-title":"Cost analysis of implant-based breast reconstruction with acellular dermal matrix","volume":"69","year":"2012","journal-title":"Ann Plast Surg"},{"key":"bib18-20250401","doi-asserted-by":"crossref","first-page":"e5058","DOI":"10.1097\/GOX.0000000000005058","article-title":"Single stitch Vicryl mesh wrap for prepectoral implant breast reconstruction","volume":"11","year":"2023","journal-title":"Plast Reconstr Surg Glob Open"},{"key":"bib19-20250401","doi-asserted-by":"crossref","first-page":"41","DOI":"10.1177\/229255031602400110","article-title":"Surgical mesh for ventral incisional hernia repairs: understanding mesh design","volume":"24","year":"2016","journal-title":"Plast Surg (Oakv)"},{"key":"bib20-20250401","doi-asserted-by":"crossref","first-page":"950","DOI":"10.1007\/s11605-022-05248-6","article-title":"Risks and prevention of surgical site infection after hernia mesh repair and the predictive utility of ACS-NSQIP","volume":"26","year":"2022","journal-title":"J Gastrointest Surg"}],"container-title":["Annals of Plastic Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.1097\/SAP.0000000000004292","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,4]],"date-time":"2026-08-04T15:17:55Z","timestamp":1785856675000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.1097\/SAP.0000000000004292"}},"subtitle":["A Preclinical Study"],"short-title":[],"issued":{"date-parts":[[2025,4]]},"references-count":18,"journal-issue":{"issue":"4S","published-print":{"date-parts":[[2025]]}},"URL":"https:\/\/doi.org\/10.1097\/sap.0000000000004292","relation":{},"ISSN":["1536-3708","0148-7043"],"issn-type":[{"value":"1536-3708","type":"electronic"},{"value":"0148-7043","type":"print"}],"subject":[],"published":{"date-parts":[[2025,4]]}}}