{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,3]],"date-time":"2026-02-03T18:29:37Z","timestamp":1770143377647,"version":"3.49.0"},"reference-count":27,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"1","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":["Ann Plast Surg"],"published-print":{"date-parts":[[2025,7]]},"abstract":"<jats:sec>\n            <jats:title>Background<\/jats:title>\n            <jats:p>Sentinel lymph node biopsy (SLNB) plays a crucial role in the clinical staging of cutaneous melanoma, influencing both treatment decisions and survival prognosis. This study aims to evaluate the benefits of combining indocyanine green (ICG) angiography with sentinel lymphoscintigraphy compared to the use of isolated sentinel lymphoscintigraphy.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Materials and Methods<\/jats:title>\n            <jats:p>A retrospective analysis was conducted comparing patients who underwent SLNB with isolated sentinel lymphoscintigraphy (isolated group) to those who received SLNB with a combined approach involving both sentinel lymphoscintigraphy and ICG lymphangiography (combined group). The success rates of SLNB, the incidence of false negatives, and the feasibility of using ICG alone were assessed.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results<\/jats:title>\n            <jats:p>The success rate for detecting at least 1 lymph node was 92.6% in the isolated group and 100% in the combined group. Among the 16 patients in the isolated group with negative SLNB results, 3 (18.7%) experienced lymph node recurrence. In contrast, none of the 16 patients in the combined group exhibited recurrence (<jats:italic toggle=\"yes\">P<\/jats:italic> &gt; 0.05). The combined method resulted in a 26.7% increase in the average number of excised lymph nodes compared to the isolated method.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusions<\/jats:title>\n            <jats:p>The integration of ICG lymphangiography with sentinel lymphoscintigraphy enhances lymph node sampling and detection sensitivity, thereby reducing the false-negative rate. However, there is insufficient evidence to support the adequacy of using ICG alone for SLNB.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/sap.0000000000004348","type":"journal-article","created":{"date-parts":[[2025,4,11]],"date-time":"2025-04-11T00:00:11Z","timestamp":1744329611000},"page":"70-75","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":1,"title":["A Comparative Analysis of Sentinel Lymph Node Sampling Utilizing Sentinel Lymphoscintigraphy Alone Versus the Combined Application of Sentinel Lymphoscintigraphy and Fluorescence Lymphangiography"],"prefix":"10.1097","volume":"95","author":[{"ORCID":"https:\/\/orcid.org\/0009-0001-3058-1921","authenticated-orcid":false,"given":"Nurullah","family":"G\u00fcnd\u00fcz","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0009-0009-1640-0002","authenticated-orcid":false,"given":"Muzaffer","family":"Duran","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"\u0130lknur","family":"Akbulut","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-7533-7877","authenticated-orcid":false,"given":"Serhat","family":"\u015eibar","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5067-6450","authenticated-orcid":false,"given":"M. S\u00fchan","family":"Ayhan","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","published-online":{"date-parts":[[2025,3,26]]},"reference":[{"key":"bib1-20250627","first-page":"201","article-title":"Use of indocyanine green for sentinel lymph node biopsy in melanoma","volume":"36","year":"2022","journal-title":"Proc (Bayl Univ Med Cent)"},{"key":"bib2-20250627","doi-asserted-by":"crossref","first-page":"888","DOI":"10.1002\/jso.23745","article-title":"Indocyanine green and fluorescence lymphangiography for sentinel lymph node identification in cutaneous melanoma","volume":"110","year":"2014","journal-title":"J Surg Oncol"},{"key":"bib3-20250627","doi-asserted-by":"crossref","first-page":"e498","DOI":"10.1097\/RLU.0000000000001370","article-title":"Sentinel lymph node biopsy in cutaneous melanoma: standard and new technical procedures and clinical advances. A systematic review of the literature","volume":"41","year":"2016","journal-title":"Clin Nucl Med"},{"key":"bib4-20250627","doi-asserted-by":"crossref","first-page":"16","DOI":"10.1097\/CMR.0b013e3282f2017d","article-title":"Postoperative morbidity of lymph node excision for cutaneous melanoma-sentinel lymphonodectomy versus complete regional lymph node dissection","volume":"18","year":"2008","journal-title":"Melanoma Res"},{"key":"bib5-20250627","doi-asserted-by":"crossref","first-page":"203","DOI":"10.1016\/S0039-6060(98)70121-7","article-title":"Improved sentinel lymph node localization in patients with primary melanoma with the use of radiolabeled colloid","volume":"124","year":"1998","journal-title":"Surgery"},{"key":"bib6-20250627","doi-asserted-by":"crossref","first-page":"302","DOI":"10.1097\/01.sla.0000181092.50141.fa","article-title":"Sentinel node biopsy for early-stage melanoma: accuracy and morbidity in MSLT-I, an international multicenter trial","volume":"242","year":"2005","journal-title":"Ann Surg"},{"key":"bib7-20250627","doi-asserted-by":"crossref","first-page":"520","DOI":"10.1016\/S0002-9610(02)01102-9","article-title":"Patterns of early recurrence after sentinel lymph node biopsy for melanoma","volume":"184","year":"2002","journal-title":"Am J Surg"},{"key":"bib8-20250627","doi-asserted-by":"crossref","first-page":"2018","DOI":"10.1245\/s10434-008-0273-8","article-title":"Clinical considerations on sentinel node biopsy in melanoma from an Italian multicentric study on 1,313 patients (SOLISM-IMI)","volume":"16","year":"2009","journal-title":"Ann Surg Oncol"},{"key":"bib9-20250627","doi-asserted-by":"crossref","first-page":"1655","DOI":"10.1245\/s10434-006-9066-0","article-title":"Survival analysis and clinicopathological factors associated with false-negative sentinel lymph node biopsy findings in patients with cutaneous melanoma","volume":"13","year":"2006","journal-title":"Ann Surg Oncol"},{"key":"bib10-20250627","doi-asserted-by":"crossref","first-page":"1479","DOI":"10.1200\/JCO.2010.33.1884","article-title":"Lymphatic mapping and sentinel lymph node biopsy in patients with melanoma: a meta-analysis","volume":"29","year":"2011","journal-title":"J Clin Oncol"},{"key":"bib11-20250627","doi-asserted-by":"crossref","first-page":"378","DOI":"10.1097\/SLA.0b013e3181855718","article-title":"Regional recurrence after negative sentinel lymph node biopsy for melanoma","volume":"248","year":"2008","journal-title":"Ann Surg"},{"key":"bib12-20250627","first-page":"940585","article-title":"A review of indocyanine green fluorescent imaging in surgery","volume":"2012","year":"2012","journal-title":"Int J Biomed Imaging"},{"key":"bib13-20250627","first-page":"307","article-title":"Lenfosintigrafi ve Sentinel Lenf Nodu: Malign Melanom Uygulama K\u0131lavuzu","volume":"6","year":"2020","journal-title":"Nucl Med Semin"},{"key":"bib14-20250627","doi-asserted-by":"crossref","first-page":"929","DOI":"10.1007\/BF02557533","article-title":"The definition of the sentinel lymph node in melanoma based on radioactive counts","volume":"9","year":"2002","journal-title":"Ann Surg Oncol"},{"key":"bib15-20250627","doi-asserted-by":"crossref","first-page":"759","DOI":"10.1097\/00000658-199412000-00009","article-title":"The orderly progression of melanoma nodal metastases","volume":"220","year":"1994","journal-title":"Ann Surg"},{"key":"bib16-20250627","first-page":"491","article-title":"Improved long-term survival after lymphadenectomy of melanoma metastatic to regional nodes. Analysis of prognostic factors in 1134 patients from the John Wayne Cancer Clinic","volume":"214","year":"1991","journal-title":"Ann Surg"},{"key":"bib17-20250627","doi-asserted-by":"crossref","first-page":"599","DOI":"10.1056\/NEJMoa1310460","article-title":"Final trial report of sentinel-node biopsy versus nodal observation in melanoma","volume":"370","year":"2014","journal-title":"N Engl J Med"},{"key":"bib18-20250627","doi-asserted-by":"crossref","first-page":"395","DOI":"10.6004\/jnccn.2013.0055","article-title":"Melanoma, version 2.2013: featured updates to the NCCN guidelines","volume":"11","year":"2013","journal-title":"J Natl Compr Canc Netw"},{"key":"bib19-20250627","doi-asserted-by":"crossref","first-page":"3313","DOI":"10.1245\/s10434-012-2475-3","article-title":"Sentinel lymph node biopsy for melanoma: American Society of Clinical Oncology and Society of Surgical Oncology joint clinical practice guideline","volume":"19","year":"2012","journal-title":"Ann Surg Oncol"},{"key":"bib20-20250627","doi-asserted-by":"crossref","first-page":"1750","DOI":"10.1007\/s00259-015-3135-1","article-title":"EANM practice guidelines for lymphoscintigraphy and sentinel lymph node biopsy in melanoma","volume":"42","year":"2015","journal-title":"Eur J Nucl Med Mol Imaging"},{"issue":"5 Suppl","key":"bib21-20250627","first-page":"645","article-title":"Progress in the management of melanoma in 2013","volume":"11","year":"2013","journal-title":"J Natl Compr Canc Netw"},{"key":"bib22-20250627","doi-asserted-by":"crossref","first-page":"2252","DOI":"10.1245\/s10434-014-3641-6","article-title":"Sentinel node biopsy improves prognostic stratification in patients with thin (pT1) melanomas and an additional risk factor","volume":"21","year":"2014","journal-title":"Ann Surg Oncol"},{"key":"bib23-20250627","doi-asserted-by":"crossref","first-page":"392","DOI":"10.1001\/archsurg.1992.01420040034005","article-title":"Technical details of intraoperative lymphatic mapping for early stage melanoma","volume":"127","year":"1992","journal-title":"Arch Surg"},{"key":"bib24-20250627","doi-asserted-by":"crossref","first-page":"217","DOI":"10.1097\/00000658-199602000-00016","article-title":"Intraoperative radio-lympho-scintigraphy improves sentinel lymph node identification for patients with melanoma","volume":"223","year":"1996","journal-title":"Ann Surg"},{"key":"bib25-20250627","doi-asserted-by":"crossref","first-page":"381","DOI":"10.1016\/j.ejso.2006.01.010","article-title":"Properties and characteristics of the dyes injected to assist axillary sentinel node localization in breast surgery","volume":"32","year":"2006","journal-title":"Eur J Surg Oncol"},{"key":"bib26-20250627","doi-asserted-by":"crossref","first-page":"198","DOI":"10.1007\/s10147-013-0524-y","article-title":"Limitation of indocyanine green fluorescence in identifying sentinel lymph node prior to skin incision in cutaneous melanoma","volume":"19","year":"2014","journal-title":"Int J Clin Oncol"},{"key":"bib27-20250627","doi-asserted-by":"crossref","first-page":"521","DOI":"10.1148\/radiol.14140322","article-title":"Multimodal surgical guidance during sentinel node biopsy for melanoma: combined gamma tracing and fluorescence imaging of the sentinel node through use of the hybrid tracer Indocyanine green-(99m)Tc-Nanocolloid","volume":"275","year":"2015","journal-title":"Radiology"}],"container-title":["Annals of Plastic Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/SAP.0000000000004348","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,6,27]],"date-time":"2025-06-27T18:00:44Z","timestamp":1751047244000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/SAP.0000000000004348"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,3,26]]},"references-count":27,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2025]]}},"URL":"https:\/\/doi.org\/10.1097\/sap.0000000000004348","relation":{},"ISSN":["1536-3708","0148-7043"],"issn-type":[{"value":"1536-3708","type":"electronic"},{"value":"0148-7043","type":"print"}],"subject":[],"published":{"date-parts":[[2025,3,26]]}}}