{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,5]],"date-time":"2026-06-05T04:49:01Z","timestamp":1780634941129,"version":"3.54.1"},"reference-count":13,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"4","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":["Ann Plast Surg"],"published-print":{"date-parts":[[2025,10]]},"abstract":"<jats:sec>\n            <jats:title>Background<\/jats:title>\n            <jats:p>Suturing cartilage can be challenging, especially when tissue shredding occurs due to repeated needle passes. The study aimed to evaluate two primary outcomes: (1) to evaluate the force required to puncture cartilage and (2) the suture retention strength, comparing two distinct needle geometries.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods<\/jats:title>\n            <jats:p>Puncture force and tear-through force were measured with a tensiometer and fresh rabbit ear cartilage. Taper point needles tested included: RB-1 on 3-0 Monocryl, TF on 4-0 Monocryl, BB on 5-0 Prolene, and C-1 on 5-0 Prolene. Reverse cutting needles included: PS-2 on 3-0 Monocryl, P-3 on 4-0, PS-3 on 5-0, and P-3 on 5-0 Prolene.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results<\/jats:title>\n            <jats:p>The mean force required to puncture cartilage with RB-1, TF, and C-1 needles was 0.66 Newtons (N), 0.90 N, and 0.69 N. For PS-2, 4-0 P-3, and 5-0 P-3 needles, the mean puncture force was 0.63 N, 0.74 N, and 0.61 N, respectively. The mean tear-through force of cartilage with sutures placed by RB-1, TF, BB, PS-2, P-3, PS-3 needles was 14 N, 16.03 N, 10.24 N, 9.91 N, 13.5 N, and 8.57 N, respectively.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusions<\/jats:title>\n            <jats:p>Although both needle geometries require similar puncture forces, reverse cutting needles demonstrated a higher propensity for cartilage tearing. These findings suggest that taper point needles may offer superior retention and diminished cartilage trauma for suturing cartilage.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/sap.0000000000004430","type":"journal-article","created":{"date-parts":[[2025,9,11]],"date-time":"2025-09-11T17:00:27Z","timestamp":1757610027000},"page":"423-426","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":1,"title":["Assessment of Needle Point Behavior in Cartilage"],"prefix":"10.1097","volume":"95","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-1621-6458","authenticated-orcid":false,"given":"McKenzie E.","family":"Maloney","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Christian T.","family":"Potter","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Benjamin D.","family":"Chun","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dean A.","family":"Liang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Richard D.","family":"Montilla","sequence":"additional","affiliation":[{"name":"Division of Plastic Surgery, University of Massachusetts Medical School, Boston, MA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Carl F.","family":"Schanbacher","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"bib1-20250911","doi-asserted-by":"crossref","first-page":"713","DOI":"10.1016\/S0030-6665(05)70015-3","article-title":"Auricular reconstruction","volume":"34","year":"2001","journal-title":"Otolaryngol Clin North Am"},{"key":"bib2-20250911","doi-asserted-by":"crossref","first-page":"201","DOI":"10.1016\/S0094-1298(01)00004-9","article-title":"Reconstruction of the ear after skin and cartilage loss","volume":"29","year":"2002","journal-title":"Clin Plast Surg"},{"key":"bib3-20250911","doi-asserted-by":"crossref","first-page":"87","DOI":"10.1016\/S0094-1298(03)00117-2","article-title":"Ear reconstruction","volume":"31","year":"2004","journal-title":"Clin Plast Surg"},{"key":"bib4-20250911","first-page":"62","article-title":"Auricular reconstruction of helical rim defects: wedge resection revisited","volume":"28","year":"2002","journal-title":"Dermatol Surg"},{"key":"bib6-20250911","doi-asserted-by":"crossref","first-page":"e19.00133","DOI":"10.2106\/JBJS.RVW.19.00133","article-title":"Suture and needle characteristics in orthopaedic surgery","volume":"8","year":"2020","journal-title":"JBJS Rev"},{"issue":"1\u20132","key":"bib7-20250911","first-page":"62","article-title":"Effects of needle shape on the integrity of the vascular endothelium","volume":"77","year":"1985","journal-title":"Acta Neurochir"},{"key":"bib10-20250911","doi-asserted-by":"crossref","first-page":"144","DOI":"10.1097\/DSS.0000000000004401","article-title":"Comparative analysis of taper point and reverse cutting needles on skin puncture force","volume":"51","year":"2025","journal-title":"Dermatol Surg"},{"key":"bib11-20250911","doi-asserted-by":"crossref","first-page":"148","DOI":"10.1097\/DSS.0000000000004389","article-title":"Impact of needle design and suture gauge on tissue tearing during skin suturing: a comparative analysis","volume":"51","year":"2025","journal-title":"Dermatol Surg"},{"key":"bib12-20250911","first-page":"781","article-title":"Scanning electron microscopic study of disturbances in arterial walls following microsurgical needle perforations","volume":"Pt 2","year":"1982","journal-title":"Scan Electron Microsc"},{"key":"bib14-20250911","doi-asserted-by":"crossref","first-page":"3394","DOI":"10.1523\/JNEUROSCI.4822-03.2004","article-title":"Human ability to scale and discriminate forces typical of those occurring during grasp and manipulation","volume":"24","year":"2004","journal-title":"J Neurosci"},{"key":"bib15-20250911","first-page":"E399","article-title":"Age-related histologic and biochemical changes in auricular and septal cartilage","volume":"127","year":"2017","journal-title":"Laryngoscope"},{"issue":"Pt 1","key":"bib16-20250911","first-page":"345","article-title":"Ageing and zonal variation in post-translational modification of collagen in normal human articular cartilage. The age-related increase in non-enzymatic glycation affects biomechanical properties of cartilage","volume":"330 ( Pt 1)","year":"1998","journal-title":"Biochem J"},{"key":"bib17-20250911","doi-asserted-by":"crossref","first-page":"480","DOI":"10.1097\/DSS.0000000000002875","article-title":"Correlation of suture diameter with its ability to cut through an artificial skin model","volume":"47","year":"2021","journal-title":"Dermatol Surg"}],"container-title":["Annals of Plastic Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/SAP.0000000000004430","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,9,11]],"date-time":"2025-09-11T17:00:29Z","timestamp":1757610029000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/SAP.0000000000004430"}},"subtitle":["Investigating Puncture Force and Suture Retention"],"short-title":[],"issued":{"date-parts":[[2025,10]]},"references-count":13,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2025]]}},"URL":"https:\/\/doi.org\/10.1097\/sap.0000000000004430","relation":{},"ISSN":["1536-3708","0148-7043"],"issn-type":[{"value":"1536-3708","type":"electronic"},{"value":"0148-7043","type":"print"}],"subject":[],"published":{"date-parts":[[2025,10]]},"assertion":[{"value":"2024-11-18","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-05-23","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}