{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,15]],"date-time":"2026-05-15T08:14:15Z","timestamp":1778832855875,"version":"3.51.4"},"reference-count":26,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"5S","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2026,5]]},"abstract":"<jats:sec>\n                    <jats:title>Background:<\/jats:title>\n                    <jats:p>Deep inferior epigastric perforator (DIEP) flaps are the gold standard in autologous breast reconstruction (ABR) despite being associated with significant abdominal donor-site morbidity. Some surgeons place mesh during abdominal closure to potentially mitigate the risk of postoperative hernias. Nonetheless, existing research on the efficacy of this practice has been limited by small cohort studies. This study aims to evaluate factors that influence mesh placement in DIEP ABR and to assess the short- and long-term effects of mesh placement on postoperative hernia development and donor-site morbidity using a large healthcare database.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>The TriNetX health database was queried to identify patients who underwent DIEP flap reconstruction with or without abdominal mesh using CPT and HCPCS codes. Cox regression analysis was performed to identify significant covariates influencing both mesh placement and postoperative hernia risk. Patients with BMI\u2009of \u226530\u2009kg\/m2 were stratified by mesh placement and propensity-score matched 1:1 by demographics and comorbidities. Risk ratios were calculated to determine 5-year hernia rates between the matched cohorts.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>\n                      Among 12,593 patients who underwent DIEP ABR, 1100 patients (8.7%) had abdominal mesh placed at the time of surgery. Cox regression demonstrated that a BMI\u2009of \u226530\u2009kg\/m2 and advanced age were significant predictors of postoperative hernias (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      \u2009&lt;\u20090.0001). ABR patients were more likely to receive mesh if they had a BMI\u2009of \u226530 kg\/m2 (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      \u2009&lt;\u20090.0001), prior hernia repairs (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      \u2009&lt;\u20090.05), tobacco use (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      \u2009&lt;\u20090.05), or advanced age (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      \u2009&lt;\u20090.01). After propensity-score matching, mesh placement did not significantly reduce 30-day donor-site morbidity or 5-year hernia rates in patients with a BMI\u2009of \u226530\u2009kg\/m2.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions:<\/jats:title>\n                    <jats:p>These findings suggest that surgeons preferentially place mesh in patients they perceive to be at high risk of postoperative complications, particularly those with obesity, history of hernia repairs, tobacco use, and advanced age. Nonetheless, mesh placement during DIEP reconstruction does not provide the anticipated protective effect against postoperative hernias or reduction in donor-site morbidity, even in higher risk patients with a BMI\u2009of \u226530\u2009kg\/m2. These findings challenge the routine use of mesh during abdominal closure in DIEP flap breast reconstruction and suggest that more targeted approaches to reducing donor-site complications are warranted.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1097\/sap.0000000000004650","type":"journal-article","created":{"date-parts":[[2026,1,28]],"date-time":"2026-01-28T20:00:11Z","timestamp":1769630411000},"page":"S215-S219","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":0,"title":["Selective Mesh Placement in DIEP Flap Reconstruction"],"prefix":"10.1097","volume":"96","author":[{"given":"Micaela J.","family":"Tobin","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Noelle C.","family":"Garbaccio","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Bradley","family":"Colarusso","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Audrey K.","family":"Mustoe","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Maria J.","family":"Escobar-Domingo","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Agustin N.","family":"Posso","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sarah J.","family":"Karinja","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5533-3166","authenticated-orcid":false,"given":"Bernard T.","family":"Lee","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","published-online":{"date-parts":[[2026,1,28]]},"reference":[{"key":"bib1-20260515","doi-asserted-by":"crossref","first-page":"199e","DOI":"10.1097\/PRS.0000000000011373","article-title":"Contemporary microsurgical breast reconstruction: abdominally based flaps","volume":"154","author":"Tanna","year":"2024","journal-title":"Plast Reconstr Surg"},{"key":"bib2-20260515","doi-asserted-by":"crossref","first-page":"891","DOI":"10.1001\/jamasurg.2018.1677","article-title":"Long-term patient-reported outcomes in postmastectomy breast reconstruction","volume":"153","author":"Santosa","year":"2018","journal-title":"JAMA Surg"},{"key":"bib3-20260515","doi-asserted-by":"crossref","first-page":"278","DOI":"10.1016\/j.bjps.2019.09.040","article-title":"Autologous versus implant-based breast reconstruction: a systematic review and meta-analysis of breast-Q patient-reported outcomes","volume":"73","author":"Toyserkani","year":"2020","journal-title":"J Plast Reconstr Aesthet Surg"},{"key":"bib4-20260515","doi-asserted-by":"crossref","first-page":"2499","DOI":"10.1200\/JCO.2016.69.9561","article-title":"Patient-reported outcomes 1\u2009year after immediate breast reconstruction: results of the mastectomy reconstruction outcomes consortium study","volume":"35","author":"Pusic","year":"2017","journal-title":"J Clin Oncol"},{"key":"bib5-20260515","doi-asserted-by":"crossref","first-page":"19","DOI":"10.1097\/PRS.0b013e31821e70ff","article-title":"The volume-outcome relationship for immediate breast reconstruction","volume":"129","author":"Tanna","year":"2012","journal-title":"Plast Reconstr Surg"},{"key":"bib6-20260515","doi-asserted-by":"crossref","first-page":"972e","DOI":"10.1097\/PRS.0000000000010382","article-title":"Short fasciotomy-deep inferior epigastric perforator flap harvest for breast reconstruction","volume":"152","author":"Kim","year":"2023","journal-title":"Plast Reconstr Surg"},{"key":"bib7-20260515","doi-asserted-by":"crossref","first-page":"1108","DOI":"10.1016\/j.bjps.2021.11.020","article-title":"Limiting the fascia incision length in a DIEP flap: repercussion on abdominal wall morbidity","volume":"75","author":"Hilven","year":"2022","journal-title":"J Plast Reconstr Aesthet Surg"},{"key":"bib8-20260515","doi-asserted-by":"crossref","first-page":"476","DOI":"10.1097\/SAP.0000000000002538","article-title":"Postoperative abdominal bulge and hernia rates in patients undergoing abdominally based autologous breast reconstruction: systematic review and meta-analysis","volume":"86","author":"Espinosa-de-Los-Monteros","year":"2021","journal-title":"Ann Plast Surg"},{"key":"bib9-20260515","doi-asserted-by":"crossref","first-page":"1383","DOI":"10.1097\/PRS.0b013e3182a805a3","article-title":"Comprehensive analysis of donor-site morbidity in abdominally based free flap breast reconstruction","volume":"132","author":"Chang","year":"2013","journal-title":"Plast Reconstr Surg"},{"key":"bib10-20260515","doi-asserted-by":"crossref","first-page":"2194","DOI":"10.1016\/j.bjps.2020.12.044","article-title":"Abdominal weakness, bulge, or hernia after DIEP flaps: an algorithm of management, prevention, and surgical repair with classification","volume":"74","author":"Haddock","year":"2021","journal-title":"J Plast Reconstr Aesthet Surg"},{"key":"bib11-20260515","doi-asserted-by":"crossref","first-page":"749","DOI":"10.1097\/01.prs.0000479931.96538.c5","article-title":"Surgically treated hernia following abdominally based autologous breast reconstruction: prevalence, outcomes, and expenditures","volume":"137","author":"Shubinets","year":"2016","journal-title":"Plast Reconstr Surg"},{"key":"bib12-20260515","doi-asserted-by":"crossref","first-page":"682","DOI":"10.1016\/j.bjps.2014.01.017","article-title":"The impact of complications on function, health, and satisfaction following abdominally based autologous breast reconstruction: a prospective evaluation","volume":"67","author":"Lu","year":"2014","journal-title":"J Plast Reconstr Aesthet Surg"},{"key":"bib13-20260515","doi-asserted-by":"crossref","first-page":"1980","DOI":"10.1111\/tbj.14003","article-title":"Donor site aesthetics and morbidity after DIEP flap breast reconstruction-a retrospective multicenter study","volume":"26","author":"Gr\u00fcnherz","year":"2020","journal-title":"Breast J"},{"key":"bib14-20260515","doi-asserted-by":"crossref","first-page":"1519","DOI":"10.1097\/PRS.0b013e31816b1458","article-title":"Risk factors for abdominal donor-site morbidity in free flap breast reconstruction","volume":"121","author":"Vyas","year":"2008","journal-title":"Plast Reconstr Surg"},{"key":"bib15-20260515","doi-asserted-by":"crossref","first-page":"1575","DOI":"10.1001\/jama.2016.15217","article-title":"Long-term recurrence and complications associated with elective incisional hernia repair","volume":"316","author":"Kokotovic","year":"2016","journal-title":"JAMA"},{"key":"bib16-20260515","doi-asserted-by":"crossref","first-page":"855","DOI":"10.1002\/micr.31107","article-title":"Evaluating mesh use for abdominal donor site closure after deep inferior epigastric perforator flap breast reconstruction: a systematic review and meta-analysis","volume":"43","author":"Parmeshwar","year":"2023","journal-title":"Microsurgery"},{"issue":"5S Suppl 5","key":"bib17-20260515","doi-asserted-by":"crossref","first-page":"S295","DOI":"10.1097\/SAP.0000000000001468","article-title":"Using mesh to reinforce the abdominal wall in abdominal free flaps for breast reconstruction: is there a benefit? What are the risks?","volume":"80","author":"Leon","year":"2018","journal-title":"Ann Plast Surg"},{"key":"bib18-20260515","doi-asserted-by":"crossref","first-page":"907","DOI":"10.1007\/s00266-020-02096-0","article-title":"The use of semi-absorbable mesh and its impact on donor-site morbidity and patient-reported outcomes in DIEP flap breast reconstruction","volume":"45","author":"Siegwart","year":"2021","journal-title":"Aesthetic Plast Surg"},{"key":"bib19-20260515","doi-asserted-by":"crossref","first-page":"3683","DOI":"10.1016\/j.bjps.2022.06.017","article-title":"Prevention and management of post-deep inferior epigastric perforator flap abdominal bulge: a 5-year single-surgeon series","volume":"75","author":"Jakeman","year":"2022","journal-title":"J Plast Reconstr Aesthet Surg"},{"issue":"4S Suppl 2","key":"bib20-20260515","doi-asserted-by":"crossref","first-page":"S283","DOI":"10.1097\/SAP.0000000000004252","article-title":"Complications after deep inferior epigastric perforator flap breast reconstruction for nipple-sparing mastectomy: a series of 380 flaps","volume":"94","author":"Zhang","year":"2025","journal-title":"Ann Plast Surg"},{"key":"bib21-20260515","doi-asserted-by":"crossref","first-page":"6623","DOI":"10.1007\/s00266-025-05163-6","article-title":"Comparing minimally invasive and conventional approaches to DIEP flap harvest: a matched-pair analysis from a high-volume center","volume":"49","author":"Bucher","year":"2025","journal-title":"Aesthetic Plast Surg"},{"key":"bib22-20260515","doi-asserted-by":"crossref","first-page":"516","DOI":"10.1097\/SAP.0000000000000936","article-title":"Deep inferior epigastric perforator versus free transverse rectus abdominis myocutaneous flap: complications and resource utilization","volume":"78","author":"Zoghbi","year":"2017","journal-title":"Ann Plast Surg"},{"key":"bib23-20260515","doi-asserted-by":"crossref","first-page":"1527","DOI":"10.1097\/PRS.0b013e31816b14a5","article-title":"DIEP flaps in women with abdominal scars: are complication rates affected?","volume":"121","author":"Parrett","year":"2008","journal-title":"Plast Reconstr Surg"},{"key":"bib24-20260515","doi-asserted-by":"crossref","first-page":"583","DOI":"10.1097\/PRS.0000000000004631","article-title":"Optimizing perforator selection: a multivariable analysis of predictors for fat necrosis and abdominal morbidity in DIEP flap breast reconstruction","volume":"142","author":"Hembd","year":"2018","journal-title":"Plast Reconstr Surg"},{"key":"bib25-20260515","doi-asserted-by":"crossref","first-page":"542","DOI":"10.1097\/SAP.0000000000002897","article-title":"The plane of mesh placement does not impact abdominal donor site complications in microsurgical breast reconstruction","volume":"87","author":"Henn","year":"2021","journal-title":"Ann Plast Surg"},{"key":"bib26-20260515","doi-asserted-by":"crossref","first-page":"434","DOI":"10.1002\/micr.30541","article-title":"Comparison of Phasix, polypropylene, and primary closure of the abdominal donor site after bilateral free flap breast reconstruction: long-term evaluation of abdominal hernia and bulge formation","volume":"40","author":"Yu","year":"2020","journal-title":"Microsurgery"}],"container-title":["Annals of Plastic Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/SAP.0000000000004650","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,5,15]],"date-time":"2026-05-15T08:00:59Z","timestamp":1778832059000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/SAP.0000000000004650"}},"subtitle":["Insights From a Propensity Score\u2013Matched Analysis"],"short-title":[],"issued":{"date-parts":[[2026,1,28]]},"references-count":26,"journal-issue":{"issue":"5S","published-print":{"date-parts":[[2026]]}},"URL":"https:\/\/doi.org\/10.1097\/sap.0000000000004650","relation":{},"ISSN":["0148-7043","1536-3708"],"issn-type":[{"value":"0148-7043","type":"print"},{"value":"1536-3708","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,1,28]]}}}