{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,27]],"date-time":"2026-02-27T06:15:41Z","timestamp":1772172941021,"version":"3.50.1"},"reference-count":27,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"3","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2021,5]]},"abstract":"<jats:sec>\n            <jats:title>Abstract<\/jats:title>\n            <jats:p>This study summarized the literature regarding the application of pre-bent titanium miniplates in orthognathic surgery and evaluated the extra deformation of the manually pre-bent titanium miniplates via finite element analysis for acquiring higher surgical accuracy. The literature was reviewed with a chart. Three models of titanium miniplates with different thicknesses (1.0\u200amm, 0.8\u200amm, 0.6\u200amm) were created using COMSOL Multiphysics software for biomechanical behavior analysis. The 3 models were virtually bent into 5 angles (15 degree, 30 degree, 45 degree, 60 degree, 80 degree). respectively to simulate the preoperative virtual bending, then to simulate the practical manual bending via finite element analysis. The stresses and displacements of these models were recorded. The models from virtual bending simulation and manual bending simulation were registered to analyze the deviations. The results showed that the maximum stress and the displacement deviations between the virtual bending models and the manual bending models increased with the thickness and bending angle of the pre-bent miniplate models. To improve the surgical accuracy, measures should be applied to the manually pre-bent titanium miniplates to reduce the extra deformation when the plate being thicker and the bending angle being larger.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/scs.0000000000007125","type":"journal-article","created":{"date-parts":[[2020,10,9]],"date-time":"2020-10-09T16:08:07Z","timestamp":1602259687000},"page":"883-887","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":10,"title":["Deformation Assessment of the Manually Pre-Bent Titanium Miniplates in Orthognathic Surgery With Finite Element Analysis"],"prefix":"10.1097","volume":"32","author":[{"given":"Li-Nan","family":"Liu","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jia-Yang","family":"Li","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ke-Han","family":"Li","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Qiong-Hui","family":"Wu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yao","family":"Liu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"En","family":"Luo","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","published-online":{"date-parts":[[2020,10,8]]},"reference":[{"key":"R1-20250803","doi-asserted-by":"crossref","first-page":"251","DOI":"10.1016\/j.bjoms.2013.12.010","article-title":"Computer-assisted orthognathic surgery for correction of facial asymmetry: results of a randomised controlled clinical","volume":"52","author":"De Riu","year":"2014","journal-title":"Br J Oral Maxillofac Surg"},{"key":"R2-20250803","doi-asserted-by":"crossref","first-page":"37","DOI":"10.1016\/j.coms.2014.09.004","article-title":"Protocol for concomitant temporomandibular joint custom-fitted total joint reconstruction and orthognathic surgery using computer-assisted surgical simulation","volume":"27","author":"Movahed","year":"2015","journal-title":"Oral Maxillofac Surg Clin North Am"},{"key":"R3-20250803","doi-asserted-by":"crossref","first-page":"45","DOI":"10.1186\/1746-160X-10-45","article-title":"Mandibular reconstruction using plates prebent to fit rapid prototyping 3-dimensional printing models ameliorates contour deformity","volume":"10","author":"Azuma","year":"2014","journal-title":"Head Face Med"},{"key":"R4-20250803","doi-asserted-by":"crossref","first-page":"229","DOI":"10.1016\/j.jcms.2008.11.009","article-title":"Clinical application of 3D pre-bent titanium implants for orbital floor fractures","volume":"37","author":"Kozakiewicz","year":"2009","journal-title":"J Craniomaxillofac Surg"},{"key":"R5-20250803","doi-asserted-by":"crossref","first-page":"2026","DOI":"10.1016\/j.joms.2017.04.046","article-title":"Application of combined osteotomy and reconstruction pre-bent plate position (CORPPP) technology to assist in the precise reconstruction of segmental mandibular defects","volume":"75","author":"Liang","year":"2017","journal-title":"J Oral Maxillofac Surg"},{"key":"R6-20250803","doi-asserted-by":"crossref","first-page":"2419","DOI":"10.1016\/j.joms.2011.12.017","article-title":"Computer-aided design and computer-aided manufacturing locating guides accompanied with prebent titanium plates in orthognathic surgery","volume":"70","author":"Bai","year":"2012","journal-title":"J Oral Maxillofac Surg"},{"key":"R7-20250803","doi-asserted-by":"crossref","first-page":"586","DOI":"10.1016\/j.bjoms.2018.06.007","article-title":"Surgical guide and CAD\/CAM prebent titanium plate for sagittal split ramus osteotomy in the correction of mandibular prognathism","volume":"56","author":"Xue","year":"2018","journal-title":"Br J Oral Maxillofac Surg"},{"key":"R8-20250803","doi-asserted-by":"crossref","first-page":"2144","DOI":"10.1097\/SCS.0000000000005656","article-title":"The drilling guiding templates and pre-bent titanium plates improves the operation accuracy of orthognathic surgery with computer-aided design and computer-aided manufacturing occlusal splints for patients with facial asymmetry","volume":"30","author":"Hu","year":"2019","journal-title":"J Craniofac Surg"},{"key":"R9-20250803","doi-asserted-by":"crossref","first-page":"963e","DOI":"10.1097\/PRS.0000000000006794","article-title":"Computer-aided design and manufacturing cutting and drilling guides with prebent titanium plates improve surgical accuracy of skeletal class III malocclusion","volume":"45","author":"Li","year":"2020","journal-title":"Plast Reconstr Surg"},{"key":"R10-20250803","doi-asserted-by":"crossref","first-page":"369","DOI":"10.1007\/s10006-015-0504-7","article-title":"Analysis of residual stress and hardness in regions of pre-manufactured and manual bends in fixation plates for maxillary advancement","volume":"19","author":"Ara\u00fajo","year":"2015","journal-title":"Oral Maxillofac Surg"},{"key":"R11-20250803","first-page":"2198","article-title":"Stability of the permanently bent plates used in mandibular reconstructive surgery","volume":"2016","author":"Park","year":"2016","journal-title":"Conf Proc IEEE Eng Med Biol Soc"},{"key":"R12-20250803","doi-asserted-by":"crossref","first-page":"326","DOI":"10.1016\/j.bjoms.2012.08.007","article-title":"Finite element analysis of three patterns of internal fixation of fractures of the mandibular condyle","volume":"51","author":"Aquilina","year":"2013","journal-title":"Br J Oral Maxillofac Surg"},{"key":"R13-20250803","doi-asserted-by":"crossref","first-page":"1505","DOI":"10.1016\/j.jcms.2015.07.004","article-title":"Evaluation of prebent miniplates in fixation of Le Fort I advancement osteotomy with the finite element method","volume":"43","author":"Coskunses","year":"2015","journal-title":"J Craniomaxillofac Surg"},{"key":"R14-20250803","doi-asserted-by":"crossref","first-page":"973","DOI":"10.1016\/j.joms.2008.12.032","article-title":"Biomechanical optimization of bone plates used in rigid fixation of mandibular fractures","volume":"67","author":"Lovald","year":"2009","journal-title":"J Oral Maxillofac Surg"},{"key":"R15-20250803","doi-asserted-by":"crossref","first-page":"1117","DOI":"10.1016\/j.ijom.2008.10.004","article-title":"Comparison of biomechanical behaviour of maxilla following Le Fort I osteotomy with 2- versus 4-plate fixation using 3D-FEA. Part 1: advancement surgery","volume":"37","author":"Ata\u00e7","year":"2008","journal-title":"Int J Oral Maxillofac Surg"},{"key":"R16-20250803","first-page":"e5","article-title":"Development of a titanium plate for mandibular angle fractures with a bone defect in the lower border: finite element analysis and mechanical test","volume":"6","author":"Goulart","year":"2015","journal-title":"J Oral Maxillofac Res"},{"key":"R17-20250803","doi-asserted-by":"crossref","first-page":"1704","DOI":"10.1080\/10255842.2016.1182631","article-title":"Biomechanical interactions of different mini-plate fixations and maxilla advancements in the Le Fort I osteotomy: a finite element analysis","volume":"19","author":"Huang","year":"2016","journal-title":"Comput Methods Biomech Biomed Engin"},{"key":"R18-20250803","doi-asserted-by":"crossref","first-page":"21","DOI":"10.1186\/s40902-015-0023-3","article-title":"A novel method for the management of proximal segment using computer assisted simulation surgery: correct condyle head positioning and better proximal segment placement","volume":"37","author":"Lee","year":"2015","journal-title":"Maxillofac Plast Reconstr Surg"},{"key":"R19-20250803","doi-asserted-by":"crossref","first-page":"797","DOI":"10.1016\/j.bjoms.2018.08.013","article-title":"Precise control of maxillary multidirectional movement in Le Fort I osteotomy using a surgical guiding device","volume":"56","author":"Xue","year":"2018","journal-title":"Br J Oral Maxillofac Surg"},{"key":"R20-20250803","doi-asserted-by":"crossref","first-page":"502","DOI":"10.1016\/j.ijom.2018.08.012","article-title":"Treatment of skeletal open bite using a navigation system: CAD\/CAM osteotomy and drilling guides combined with pre-bent titanium plates","volume":"48","author":"Du","year":"2019","journal-title":"Int J Oral Maxillofac Surg"},{"key":"R21-20250803","doi-asserted-by":"crossref","first-page":"901","DOI":"10.1016\/j.ijom.2019.11.013","article-title":"Accuracy of mandible-independent maxillary repositioning using pre-bent locking plates: a pilot study","volume":"49","author":"Imai","year":"2019","journal-title":"Int J Oral Maxillofac Surg"},{"key":"R22-20250803","doi-asserted-by":"crossref","first-page":"1043","DOI":"10.1016\/j.ijom.2019.01.026","article-title":"Computer-assisted osteotomy guides and pre-bent titanium plates improve the planning for correction of facial asymmetry","volume":"48","author":"Ji","year":"2019","journal-title":"Int J Oral Maxillofac Surg"},{"key":"R23-20250803","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.jcms.2019.01.039","article-title":"Treatment of hemimandibular hyperplasia by computer-aided design and computer-aided manufacturing cutting and drilling guides accompanied with pre-bent titanium plates","volume":"48","author":"Du","year":"2020","journal-title":"J Craniomaxillofac Surg"},{"key":"R24-20250803","doi-asserted-by":"crossref","first-page":"1298","DOI":"10.1016\/j.ijom.2017.03.025","article-title":"A new approach of splint-less orthognathic surgery using a personalized orthognathic surgical guide system: a preliminary study","volume":"46","author":"Li","year":"2017","journal-title":"Int J Oral Maxillofac Surg"},{"key":"R25-20250803","first-page":"300","article-title":"Finite element analysis of a tandem screw configuration in sagittal split osteotomy using biodegradable osteosynthesis screws","volume":"16","author":"Maurer","year":"2001","journal-title":"Int J Adult Orthod Orthognath Surg"},{"key":"R26-20250803","doi-asserted-by":"crossref","first-page":"91","DOI":"10.1054\/jcms.2000.0125","article-title":"Experimental and finite element study of a human mandible","volume":"28","author":"Vollmer","year":"2000","journal-title":"J Craniomaxillofac Surg"},{"key":"R27-20250803","doi-asserted-by":"crossref","first-page":"218","DOI":"10.1055\/s-0034-1375172","article-title":"A biomechanical comparison of three 1.5-mm plate and screw configurations and a single 2.0-mm plate for internal fixation of a mandibular condylar fracture","volume":"7","author":"Aquilina","year":"2014","journal-title":"Craniomaxillofac Trauma Reconstr"}],"container-title":["Journal of Craniofacial Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/SCS.0000000000007125","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,8,3]],"date-time":"2025-08-03T17:34:57Z","timestamp":1754242497000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/SCS.0000000000007125"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,10,8]]},"references-count":27,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2021]]}},"URL":"https:\/\/doi.org\/10.1097\/scs.0000000000007125","relation":{},"ISSN":["1049-2275","1536-3732"],"issn-type":[{"value":"1049-2275","type":"print"},{"value":"1536-3732","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,10,8]]}}}