{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,10]],"date-time":"2026-01-10T07:22:53Z","timestamp":1768029773068,"version":"3.49.0"},"reference-count":18,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"5","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2021,7]]},"abstract":"<jats:sec>\n            <jats:title>Abstract<\/jats:title>\n            <jats:p>Chronic post traumatic infraorbital nerve (ION) hyperesthesia is a rare complication of orbital floor fractures. Surgical decompression of the ION has been reported to relieve chronic post traumatic infraorbital neuralgia. This case report describes a novel approach for ION decompression in a patient who suffered from chronic infraorbital neuralgia associated with a healed displaced orbital floor fracture. We used an intraoperative 3D image-guided navigation system to accurately localize the fracture site and employed piezoelectric surgery for nerve decompression. We further review the literature on the safety and efficacy of piezoelectric surgery on soft tissue and nerves.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/scs.0000000000007443","type":"journal-article","created":{"date-parts":[[2021,1,15]],"date-time":"2021-01-15T14:35:45Z","timestamp":1610721345000},"page":"e483-e485","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":4,"title":["Infraorbital Nerve Decompression for Chronic Post Traumatic Neuralgia: A Novel Approach and Review of the Safety and Efficacy of Piezoelectric Surgery on Soft Tissues and Nerves"],"prefix":"10.1097","volume":"32","author":[{"given":"Lambros K.","family":"Viennas","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Maxwell S.","family":"Wagner","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","published-online":{"date-parts":[[2021,1,14]]},"reference":[{"key":"R1-20250803","doi-asserted-by":"crossref","first-page":"49","DOI":"10.1097\/IOP.0b013e31802dd3fc","article-title":"Infraorbital nerve surgical decompression for chronic infraorbital nerve hyperesthesia","volume":"23","author":"Bailey","year":"2007","journal-title":"Ophthalmic Plast Reconstr Surg"},{"key":"R2-20250803","doi-asserted-by":"crossref","first-page":"22","DOI":"10.1055\/s-0036-1592095","article-title":"Infraorbital nerve decompression for infraorbital neuralgia\/causalgia following blowout orbital fractures: a case series","volume":"10","author":"Beigi","year":"2017","journal-title":"Craniomaxillofac Trauma Reconstr"},{"key":"R3-20250803","doi-asserted-by":"crossref","first-page":"259","DOI":"10.1111\/j.1442-9071.1998.tb01323.x","article-title":"Persistent infra-orbital nerve hyperaesthesia after blunt orbital trauma","volume":"26","author":"Supaporn","year":"1998","journal-title":"Aust New Zeal J Ophthalmol"},{"key":"R4-20250803","doi-asserted-by":"crossref","first-page":"233","DOI":"10.1097\/SCS.0000000000003439","article-title":"A rare complication of infraorbital nerve hyperesthesia in surgically repaired orbital fracture patients","volume":"28","author":"Cho","year":"2017","journal-title":"J Craniofac Surg"},{"key":"R5-20250803","first-page":"207","article-title":"Technological characteristics and clinical indications of piezoelectric bone surgery","volume":"53","author":"Vercellotti","year":"2004","journal-title":"Minerva Stomatol"},{"key":"R6-20250803","doi-asserted-by":"crossref","first-page":"265","DOI":"10.1016\/j.bjoms.2007.12.007","article-title":"Piezoelectric surgery: twenty years of use","volume":"46","author":"Mauro","year":"2008","journal-title":"Br J Oral Maxillofac Surg"},{"key":"R7-20250803","doi-asserted-by":"crossref","first-page":"19","DOI":"10.1563\/1548-1336(2006)32[19:IANTIV]2.0.CO;2","article-title":"Inferior alveolar nerve transposition - an in vitro comparison between piezosurgery and conventional bur use","volume":"32","author":"Metzger","year":"2006","journal-title":"J Oral Implantol"},{"key":"R8-20250803","doi-asserted-by":"crossref","first-page":"1966","DOI":"10.1097\/SCS.0000000000005598","article-title":"Is piezoelectric surgery really harmless to soft tissue?","volume":"30","author":"Demirbilek","year":"2019","journal-title":"J Craniofac Surg"},{"key":"R9-20250803","doi-asserted-by":"crossref","first-page":"17154","DOI":"10.1038\/s41598-018-35295-6","article-title":"Experimental comparison of the performance of cutting bone and soft tissue between piezosurgery and conventional rotary instruments","volume":"8","author":"Otake","year":"2018","journal-title":"Sci Rep"},{"key":"R10-20250803","doi-asserted-by":"crossref","first-page":"19","DOI":"10.1563\/1548-1336(2006)32[19:IANTIV]2.0.CO;2","article-title":"Inferior alveolar nerve transposition\u2014an in vitro comparison between piezosurgery and conventional bur use","volume":"32","author":"Metzger","year":"2006","journal-title":"J Oral Implantol"},{"key":"R11-20250803","doi-asserted-by":"crossref","first-page":"593","DOI":"10.1016\/j.joms.2007.03.025","article-title":"Assessment of nerve damage using a novel ultrasonic device for bone cutting","volume":"66","author":"Schaeren","year":"2008","journal-title":"J Oral Maxillofac Surg"},{"key":"R12-20250803","doi-asserted-by":"crossref","first-page":"211","DOI":"10.1055\/s-0034-1393731","article-title":"Computer-assisted three-dimensional planning for orbital decompression","volume":"8","author":"Mahoney","year":"2015","journal-title":"Craniomaxillofac Trauma Reconstr"},{"key":"R13-20250803","doi-asserted-by":"crossref","first-page":"184","DOI":"10.1080\/01676830.2018.1521844","article-title":"Piezoelectric surgery versus mechanical drilling for orbital floor decompression: effect on infraorbital hypoaesthesia","volume":"38","author":"Naik","year":"2019","journal-title":"Orbit"},{"key":"R14-20250803","doi-asserted-by":"crossref","first-page":"433","DOI":"10.1080\/01676830.2018.1552709","article-title":"A comparative analysis of piezosurgery and oscillating saw for balanced orbital decompression","volume":"38","author":"St\u00e4hr","year":"2019","journal-title":"Orbit"},{"key":"R15-20250803","doi-asserted-by":"crossref","first-page":"1813","DOI":"10.1016\/j.jcms.2014.06.020","article-title":"Piezosurgery for orbital decompression surgery in thyroid associated orbitopathy","volume":"42","author":"Ponto","year":"2014","journal-title":"J Craniomaxillofac Surg"},{"key":"R16-20250803","doi-asserted-by":"crossref","first-page":"86","DOI":"10.1016\/j.survophthal.2017.03.007","article-title":"Orbital decompression for thyroid eye disease","volume":"63","author":"Rootman","year":"2018","journal-title":"Surv Ophthalmol"},{"key":"R17-20250803","doi-asserted-by":"crossref","first-page":"940","DOI":"10.1016\/j.joms.2017.11.031","article-title":"Modified decompression of the infraorbital canal to treat trigeminal neuralgia affecting the maxillary branch","volume":"76","author":"Han","year":"2018","journal-title":"J Oral Maxillofac Surg"},{"key":"R18-20250803","doi-asserted-by":"crossref","first-page":"11779","DOI":"10.1038\/s41598-017-12225-6","article-title":"A novel mouse model of traumatic optic neuropathy using external ultrasound energy to achieve focal, indirect optic nerve injury","volume":"7","author":"Tao","year":"2017","journal-title":"Sci Rep"}],"container-title":["Journal of Craniofacial Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/SCS.0000000000007443","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,8,3]],"date-time":"2025-08-03T17:34:40Z","timestamp":1754242480000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/SCS.0000000000007443"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,1,14]]},"references-count":18,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2021]]}},"URL":"https:\/\/doi.org\/10.1097\/scs.0000000000007443","relation":{},"ISSN":["1049-2275","1536-3732"],"issn-type":[{"value":"1049-2275","type":"print"},{"value":"1536-3732","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,1,14]]}}}