{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,27]],"date-time":"2026-04-27T14:48:34Z","timestamp":1777301314268,"version":"3.51.4"},"reference-count":6,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"2","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2023,3]]},"abstract":"<jats:sec>\n                    <jats:title>Background:<\/jats:title>\n                    <jats:p>Mandibular subcondylar fractures can be fixed with 2 titanium plates or 2 resorbable plates. However, when a wider resorbable plate is used, there might be insufficient space on subcondylar region. The authors have tested the back of the condyle as an alternative location for the wide resorbable plate.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>The fractured condyle was accessed through the preauricular approach. The first resorbable plate (4 hole plate, extended; 2\u00a0mm Inion OTPSTM) was contoured around the posterior edge of the mandibular ramus. The upper and lower parts of the very resorbable plate were twisted into 2 different planes. The upper part was adapted and then fixed on the back of the condylar neck. And the lower part was fixed on the lateral surface of the posterior edge of the mandibular ramus. The second plate (4 hole plate; 2\u00a0mm Inion OTPSTM) was put below the mandibular notch as usual.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results and Discussion:<\/jats:title>\n                    <jats:p>Postoperative computed tomography confirmed a stable anatomical reduction of condyle. One-year follow-up showed good fracture healing. The authors believe that the back of the condyle is particularly suitable for wider resorbable plate. And this alternative site on the back of the condyle is also feasible in cases where the conventional site is not available.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1097\/scs.0000000000009039","type":"journal-article","created":{"date-parts":[[2022,9,23]],"date-time":"2022-09-23T00:00:59Z","timestamp":1663891259000},"page":"757-758","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":0,"title":["An Alternative Location for Fixation of Subcondylar Fractures With 2 Resorbable Plates"],"prefix":"10.1097","volume":"34","author":[{"given":"Xing","family":"Hao","sequence":"first","affiliation":[{"name":"Department of Obstetrics and Gynecology, Tongji Medical College, Tongji Hospital, Huazhong University of Science and Technology, Wuhan, People\u2019s Republic of China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1329-4381","authenticated-orcid":false,"given":"Kun","family":"Lv","sequence":"additional","affiliation":[{"name":"The State Key Laboratory Breeding Base of Basic Science of Stomatology (Hubei-MOST) and Key Laboratory of Oral Biomedicine Ministry of Education, Wuhan, People\u2019s Republic of China"},{"name":"Department of Oral and Maxillofacial Surgery, School and Hospital of Stomatology, Wuhan University, Wuhan, People\u2019s Republic of China"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","published-online":{"date-parts":[[2022,9,23]]},"reference":[{"key":"R1-20260427","doi-asserted-by":"crossref","first-page":"1557","DOI":"10.3390\/ma12091557","article-title":"Biomechanical loading comparison between titanium and unsintered hydroxyapatite\/poly-L-lactide plate system for fixation of mandibular subcondylar fractures","volume":"12","author":"Sukegawa","year":"2019","journal-title":"Materials (Basel)"},{"key":"R2-20260427","doi-asserted-by":"crossref","first-page":"1510","DOI":"10.1016\/j.joms.2006.03.038","article-title":"Biomechanical evaluation of different types of rigid internal fixation techniques for subcondylar fractures","volume":"64","author":"Tominaga","year":"2006","journal-title":"J Oral Maxillofac Surg"},{"key":"R3-20260427","doi-asserted-by":"crossref","first-page":"48","DOI":"10.4103\/2231-0746.83157","article-title":"Review of biomechanical experimental studies on different plating techniques of mandibular condyle fractures","volume":"1","author":"Dayi","year":"2011","journal-title":"Ann Maxillofac Surg"},{"key":"R4-20260427","doi-asserted-by":"crossref","first-page":"1277","DOI":"10.1097\/SCS.0000000000002754","article-title":"Comparison of different fixation types used in unilateral mandibular condylar fractures: an in vivo study with new biomechanical model","volume":"27","author":"\u00c7imen","year":"2016","journal-title":"J Craniofac Surg"},{"key":"R5-20260427","doi-asserted-by":"crossref","first-page":"1503","DOI":"10.1016\/j.ijom.2013.06.008","article-title":"Evaluation of bioresorbable plates in condylar fracture fixation: a case series","volume":"42","author":"Singh","year":"2013","journal-title":"Int J Oral Maxillofac Surg"},{"key":"R6-20260427","doi-asserted-by":"crossref","first-page":"38","DOI":"10.1016\/j.bjoms.2005.07.026","article-title":"Inion biodegradable plates: the first century","volume":"44","author":"Wood","year":"2006","journal-title":"Br J Oral Maxillofac Surg"}],"container-title":["Journal of Craniofacial Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/SCS.0000000000009039","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,27]],"date-time":"2026-04-27T14:00:31Z","timestamp":1777298431000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/SCS.0000000000009039"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,9,23]]},"references-count":6,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2023]]}},"URL":"https:\/\/doi.org\/10.1097\/scs.0000000000009039","relation":{},"ISSN":["1049-2275"],"issn-type":[{"value":"1049-2275","type":"print"}],"subject":[],"published":{"date-parts":[[2022,9,23]]},"assertion":[{"value":"2022-08-02","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2022-08-30","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}