{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,5]],"date-time":"2026-11-05T03:15:48Z","timestamp":1793848548294,"version":"4.6.1"},"reference-count":23,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"2","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2025,3]]},"abstract":"<jats:p>External rigid distraction is an established method for achieving subcranial Le Fort III advancement in severe syndromic craniosynostosis. Craniofacial surgeons commonly use halo-type devices for these corrections, as they allow for multiple vectors of pull and facilitate larger midfacial advancements. Although most complications related to their use involve pin displacement or infection, rare complications such as skull fractures have been reported. At 3 months of age, a patient with Apert Syndrome underwent endoscopic-assisted craniectomies for bilateral coronal craniosynostosis. After a year of helmet therapy, he developed pansynostosis and required fronto-orbital advancement. Later at the age of 6, a Le Fort III distraction using a RED II rigid external distractor was performed to address his midfacial hypoplasia, exorbitism, and severe obstructive sleep apnea. While placing the RED II distractor, a shift in the device was noted upon pin fixation, raising suspicion for a unilateral depressed skull fracture. Although computed tomography imaging revealed pin displacement, there was no clinical indication for immediate repair. Given the surgical and psychological burden this could have on the patient, the decision was made to leave the RED II device in place and proceed with the distraction. After distraction and an 8-week latency period for complete consolidation of the facial bony architecture, the RED II device was removed, and the skull fracture was repaired. In patients with multi-operated skulls and residual cranial defects, halo-type devices may present an increased risk of skull fractures. This report discusses alternatives in the literature and presents an example of a rare complication successfully managed with delayed repair.<\/jats:p>","DOI":"10.1097\/scs.0000000000010959","type":"journal-article","created":{"date-parts":[[2025,1,3]],"date-time":"2025-01-03T11:00:38Z","timestamp":1735902038000},"page":"629-632","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":1,"title":["Intraoperative Skull Fracture During Halo Application in Subcranial Le Fort III: Strategies for Managing a Rare Complication"],"prefix":"10.1097","volume":"36","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-6888-5958","authenticated-orcid":false,"given":"Stephen D.","family":"Moreno","sequence":"first","affiliation":[{"name":"Department of Oral and Maxillofacial Surgery, Division of Pediatric Craniofacial Surgery, Naval Medical Center San Diego, San Diego, CA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Samuel D.","family":"Raffaelli","sequence":"additional","affiliation":[{"name":"Department of Oral and Maxillofacial Surgery, U.S. Naval Hospital Okinawa, Okinawa, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Robert H.","family":"Liu","sequence":"additional","affiliation":[{"name":"National Capital Consortium Oral and Maxillofacial Surgery Residency, Walter Reed National Military Medical Center, Bethesda, MD"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Barry","family":"Steinberg","sequence":"additional","affiliation":[{"name":"Division of Pediatric Craniofacial Surgery, Nemours Children\u2019s Health, Jacksonville, FL"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2025,1,3]]},"reference":[{"key":"R1-20250926","doi-asserted-by":"crossref","first-page":"332","DOI":"10.1597\/07-021.1","article-title":"Le Fort III rigid external distraction complicated by intracranial movement of halo fixation pins","volume":"45","author":"Breugem","year":"2008","journal-title":"Cleft Palate Craniofac J"},{"key":"R2-20250926","doi-asserted-by":"crossref","first-page":"420","DOI":"10.1016\/j.jcms.2018.11.028","article-title":"Midface correction in patients with Crouzon syndrome: Is Le Fort III distraction osteogenesis with a rigid external distraction device the gold standard?","volume":"47","author":"Engel","year":"2019","journal-title":"J Craniomaxillofac Surg"},{"key":"R3-20250926","doi-asserted-by":"crossref","first-page":"1005","DOI":"10.1097\/PRS.0b013e3181e3b70f","article-title":"Biomechanical considerations for distraction of the monobloc, Le Fort III, and Le Fort I segments","volume":"126","author":"Figueroa","year":"2010","journal-title":"Plast Reconstr Surg"},{"key":"R4-20250926","doi-asserted-by":"crossref","first-page":"1382","DOI":"10.1097\/01.PRS.0000138593.89303.1B","article-title":"Long-term skeletal stability after maxillary advancement with distraction osteogenesis using a rigid external distraction device in cleft maxillary deformities","volume":"114","author":"Figueroa","year":"2004","journal-title":"Plast Reconstr Surg"},{"key":"R5-20250926","doi-asserted-by":"crossref","first-page":"124","DOI":"10.1097\/SCS.0000000000001320","article-title":"Complications in 54 frontofacial distraction procedures in patients with syndromic craniosynostosis","volume":"26","author":"Goldstein","year":"2015","journal-title":"J Craniofac Surg"},{"key":"R6-20250926","doi-asserted-by":"crossref","first-page":"1797","DOI":"10.1097\/00006534-200205000-00004","article-title":"Midface distraction following Le Fort III and monobloc osteotomies: problems and solutions","volume":"109","author":"Gosain","year":"2002","journal-title":"Plast Reconstr Surg"},{"key":"R7-20250926","doi-asserted-by":"crossref","first-page":"184","DOI":"10.1055\/s-0034-1390171","article-title":"An update on midface advancement using Le Fort II and III distraction osteogenesis","volume":"28","author":"Tahiri","year":"2014","journal-title":"Semin Plast Surg"},{"key":"R8-20250926","doi-asserted-by":"crossref","first-page":"285","DOI":"10.1016\/j.bjoms.2014.12.016","article-title":"Three-dimensional computed tomographic evaluation of Le Fort III distraction osteogenesis with an external device in syndromic craniosynostosis","volume":"53","author":"Wery","year":"2015","journal-title":"Br J Oral Maxillofac Surg"},{"key":"R9-20250926","doi-asserted-by":"crossref","first-page":"530e","DOI":"10.1097\/PRS.0000000000010954","article-title":"Comparative study of internal device vs. external device in Le Fort III distraction for syndromic craniosynostosis","volume":"154","author":"Noto","year":"2023","journal-title":"Plast Reconstr Surg"},{"key":"R10-20250926","doi-asserted-by":"crossref","first-page":"781","DOI":"10.1016\/j.ijom.2008.04.006","article-title":"Advancement of the midface, from conventional Le Fort III osteotomy to Le Fort III distraction: review of the literature","volume":"37","author":"Nout","year":"2008","journal-title":"Int J Oral Maxillofac Surg"},{"key":"R11-20250926","doi-asserted-by":"crossref","first-page":"871","DOI":"10.1097\/PRS.0b013e3181b17b57","article-title":"Le Fort III distraction: Part I. Controlling position and vectors of the midface segment","volume":"124","author":"Shetye","year":"2009","journal-title":"Plast Reconstr Surg"},{"key":"R12-20250926","doi-asserted-by":"crossref","first-page":"320","DOI":"10.2106\/00004623-198668030-00002","article-title":"Complications in the use of halo fixation device.","volume":"68","author":"Garfin","year":"1986","journal-title":"J Bone Joint Surg Am"},{"key":"R13-20250926","doi-asserted-by":"crossref","first-page":"277","DOI":"10.1302\/0301-620X.70B2.3346303","article-title":"A biomechanical analysis of halo fixation in children","volume":"70","author":"Letts","year":"1988","journal-title":"J Bone Joint Surg Br"},{"key":"R14-20250926","doi-asserted-by":"crossref","first-page":"2399","DOI":"10.1097\/01.prs.0000204798.50710.a7","article-title":"Distraction osteogenesis in maxillary deficiency using a rigid external distraction device","volume":"117","author":"Rachmiel","year":"2006","journal-title":"Plast Reconstr Surg"},{"key":"R15-20250926","doi-asserted-by":"crossref","first-page":"377","DOI":"10.2106\/00004623-200103000-00009","article-title":"Six-pin halo fixation and the resulting prevalence of pin-site complications","volume":"83","author":"Nemeth","year":"2001","journal-title":"J Bone Joint Surg Am"},{"key":"R16-20250926","doi-asserted-by":"crossref","first-page":"401","DOI":"10.1597\/1545-1569_2001_038_0401_imohfp_2.0.co_2","article-title":"Intracranial migration of halo fixation pins: a complication of using an extraoral distraction device","volume":"38","author":"Le","year":"2001","journal-title":"Cleft Palate Craniofac J"},{"key":"R17-20250926","doi-asserted-by":"crossref","first-page":"856","DOI":"10.1097\/SCS.0b013e31824dbf8e","article-title":"Le Fort III distraction osteogenesis: modification of the intraoral splint in the rigid external distraction","volume":"23","author":"Lim","year":"2012","journal-title":"J Craniofac Surg"},{"key":"R18-20250926","doi-asserted-by":"crossref","first-page":"237","DOI":"10.1097\/00001665-200105000-00008","article-title":"Traumatic cranial injury sustained from a fall on the rigid external distraction device","volume":"12","author":"Rieger","year":"2001","journal-title":"J Craniofac Surg"},{"key":"R19-20250926","doi-asserted-by":"crossref","first-page":"1451","DOI":"10.1097\/00007632-199407000-00005","article-title":"Osteology of the pediatric skull: considerations of halo pin placement","volume":"19","author":"Wong","year":"1994","journal-title":"Spine"},{"key":"R20-20250926","doi-asserted-by":"crossref","first-page":"1557","DOI":"10.1097\/SCS.0b013e3181ecc4e7","article-title":"Intracranial fixation pin migration: a complication of external Le Fort III distraction osteogenesis in Apert syndrome","volume":"21","author":"Cai","year":"2010","journal-title":"J Craniofac Surg"},{"key":"R21-20250926","first-page":"332","article-title":"Distractieosteogenese bij pati\u00ebnten met craniofaciale anomalie\u00ebn [Distraction osteogenesis in patients with craniofacial anomalies]","volume":"115","author":"Wolvius","year":"2008","journal-title":"Ned Tijdschr Tandheelkd"},{"key":"R22-20250926","doi-asserted-by":"crossref","first-page":"377","DOI":"10.1097\/00001665-200405000-00007","article-title":"Stoppers in RED II distraction device: is it possible to prevent pin migration?","volume":"15","author":"Mavili","year":"2004","journal-title":"J Craniofac Surg"},{"key":"R23-20250926","doi-asserted-by":"crossref","first-page":"130","DOI":"10.1016\/j.joms.2005.09.021","article-title":"Intracranial migration of halo pin during distraction osteogenesis for maxillary hypoplasia: case report and literature review","volume":"64","author":"Brown","year":"2006","journal-title":"J Oral Maxillofac Surg"}],"container-title":["Journal of Craniofacial Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/SCS.0000000000010959","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,9,26]],"date-time":"2025-09-26T22:01:22Z","timestamp":1758924082000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/SCS.0000000000010959"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,1,3]]},"references-count":23,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2025]]}},"URL":"https:\/\/doi.org\/10.1097\/scs.0000000000010959","relation":{},"ISSN":["1049-2275","1536-3732"],"issn-type":[{"value":"1049-2275","type":"print"},{"value":"1536-3732","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,1,3]]},"assertion":[{"value":"2024-10-16","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2024-11-14","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}