{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,9]],"date-time":"2026-07-09T00:47:54Z","timestamp":1783558074362,"version":"3.55.0"},"reference-count":20,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"8","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2025,11]]},"abstract":"<jats:p>Mandibular fractures account for 42% of maxillofacial injuries, with condylar fractures representing 25%-35% of these cases. Despite the prevalence, the optimal method for treating condylar fractures remains debated, though internal rigid fixation is commonly used for stability. Recent focus has shifted to evaluating specific fixation methods for condylar fractures, including single miniplates, double miniplates, lag screws, and 3D plates, aiming to determine if a single miniplate can be as effective as or better than more complex systems. This study employs finite element analysis (FEA) to evaluate a novel fixation device for condylar fractures, which involves an intramedullary neck screw fixed with additional screws. Using 3D models of the mandible, miniplates, and screws, simulations were performed to assess stress distribution and displacement under varying loads. The analysis revealed that the fixation system provided stable results with minimal deformation and stress concentration in critical areas. The device demonstrated adequate stability, with no mechanical failures observed. The study concludes that the new fixation technique offers a viable alternative for treating mandibular condylar fractures, potentially simplifying the procedure and reducing costs compared with more complex fixation methods.<\/jats:p>","DOI":"10.1097\/scs.0000000000012002","type":"journal-article","created":{"date-parts":[[2025,10,2]],"date-time":"2025-10-02T21:00:12Z","timestamp":1759438812000},"page":"e1473-e1477","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":1,"title":["Finite Element Analysis (FEA) to Support a New Device to Treat Mandible Subcondylar Fractures"],"prefix":"10.1097","volume":"36","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-6678-8780","authenticated-orcid":false,"given":"Ricardo Augusto","family":"Conci","sequence":"first","affiliation":[{"name":"Department of Oral and Maxillofacial Surgery - Western Parana State University - Unioeste, Cascavel, Parana, Brazil"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Roberto Ferreira","family":"Zanin","sequence":"additional","affiliation":[{"name":"Passo Fundo, Rio Grande do Sul, Brazil"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Fernando","family":"de Oliveira Andriola","sequence":"additional","affiliation":[{"name":"Department of Oral and Maxillofacial Surgery, Pontif\u00edcia Universidade Cat\u00f3lica do Rio Grande do Sul\u2014PUCRS, Porto Alegre, Rio Grande do Sul"},{"name":"Pontifical Catholic University of Rio Grande do Sul (PUCRS), Porto Alegre, Brazil"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Guilherme Genehr","family":"Fritscher","sequence":"additional","affiliation":[{"name":"Department of Oral and Maxillofacial Surgery, Pontif\u00edcia Universidade Cat\u00f3lica do Rio Grande do Sul\u2014PUCRS, Porto Alegre, Rio Grande do Sul"},{"name":"Pontifical Catholic University of Rio Grande do Sul (PUCRS), Porto Alegre, Brazil"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Claiton","family":"Heitz","sequence":"additional","affiliation":[{"name":"Department of Oral and Maxillofacial Surgery, Pontif\u00edcia Universidade Cat\u00f3lica do Rio Grande do Sul\u2014PUCRS, Porto Alegre, Rio Grande do Sul"},{"name":"Pontifical Catholic University of Rio Grande do Sul (PUCRS), Porto Alegre, Brazil"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2025,10,2]]},"reference":[{"key":"R1-20260106","doi-asserted-by":"crossref","first-page":"586","DOI":"10.1111\/edt.12871","article-title":"Treatment of extracapsular fractures of the mandibular condylar process: a retrospective evaluation of 377 cases","volume":"39","author":"Maurer","year":"2023","journal-title":"Dent Traumatol"},{"key":"R2-20260106","doi-asserted-by":"crossref","first-page":"525","DOI":"10.1016\/j.bjoms.2020.03.014","article-title":"Mandibular condylar fracture: a systematic review of systematic reviews and a proposed algorithm for management","volume":"58","author":"Alyahya","year":"2020","journal-title":"Br J Oral Maxillofac Surg"},{"key":"R3-20260106","doi-asserted-by":"crossref","first-page":"288","DOI":"10.1016\/S0266-4356(97)90050-4","article-title":"Osteosynthesis of condylar neck fractures: a review of 30 patients","volume":"35","author":"Hammer","year":"1997","journal-title":"Br J Oral Maxillofac Surg"},{"key":"R4-20260106","doi-asserted-by":"crossref","first-page":"848","DOI":"10.1016\/j.bjoms.2020.04.053","article-title":"Assessment of biomechanical properties of specially-designed miniplate patterns in a mandibular subcondylar fracture model with finite element analysis and a servohydraulic testing unit","volume":"58","author":"Kolsuz","year":"2020","journal-title":"Br J Oral Maxillofac Surg"},{"key":"R5-20260106","doi-asserted-by":"crossref","first-page":"83","DOI":"10.1016\/j.bjoms.2023.11.004","article-title":"How good is good enough? Lessons learned from review of outcomes of 50 patients following extraoral open reduction and internal fixation of condylar neck and base fractures at a regional major trauma centre","volume":"62","author":"Leow","year":"2024","journal-title":"Br J Oral Maxillofac Surg"},{"key":"R6-20260106","doi-asserted-by":"crossref","first-page":"482","DOI":"10.1016\/j.joms.2014.09.027","article-title":"Surgical treatment of adult mandibular condylar fractures provides better outcomes than closed treatment: a systematic review and meta-analysis","volume":"73","author":"Al-Moraissi","year":"2015","journal-title":"J Oral Maxillofac Surg"},{"key":"R7-20260106","doi-asserted-by":"crossref","first-page":"934e941","DOI":"10.1016\/j.ijom.2012.03.018","article-title":"Comparison of five different fixation techniques of sagittal split ramus osteotomy using three-dimensional finite elements analysis","volume":"41","author":"Sato","year":"2012","journal-title":"Int J Oral Maxillofac Surg"},{"key":"R8-20260106","doi-asserted-by":"crossref","first-page":"1321e1327","DOI":"10.1016\/j.joms.2015.01.037","article-title":"Comparison of neck screw and conventional fixation techniques in mandibular condyle fractures using 3-dimensional finite element analysis","volume":"73","author":"Conci","year":"2015","journal-title":"J Oral Maxillofac Surg"},{"key":"R9-20260106","doi-asserted-by":"crossref","first-page":"1041e1045","DOI":"10.1016\/j.jcms.2018.04.008","article-title":"Does lag screw fixation of condylar fractures result in adequate stability? A finite element analysis","volume":"46","author":"Conci","year":"2018","journal-title":"J Craniomaxillofac Surg"},{"key":"R10-20260106","doi-asserted-by":"crossref","first-page":"391e397","DOI":"10.1016\/j.jcms.2017.12.020","article-title":"Three-dimensional titanium miniplates for fixation of subcondylar mandibular fractures: comparison of five designs using patient-specific finite element analysis","volume":"46","author":"Albogha","year":"2018","journal-title":"J Craniomaxillofac Surg"},{"key":"R11-20260106","doi-asserted-by":"crossref","first-page":"105354","DOI":"10.1016\/j.jmbbm.2022.105354","article-title":"Biomechanical evaluation of various internal fixation patterns for unilateral mandibular condylar base fractures: a three-dimensional finite element analysis","volume":"133","author":"Li","year":"2022","journal-title":"J Mech Behav Biomed Mat"},{"key":"R12-20260106","doi-asserted-by":"crossref","first-page":"27","DOI":"10.1186\/s13005-023-00370-5","article-title":"Load distribution after unilateral condylar fracture with shortening of the ramus: a finite element model study","volume":"19","author":"Helmer","year":"2023","journal-title":"Head Face Med"},{"key":"R13-20260106","doi-asserted-by":"crossref","first-page":"756","DOI":"10.1016\/j.ijom.2020.10.009","article-title":"Fixation of subcondylar fractures of the mandible: a randomized clinical trial comparing one trapezoidal plate with two miniplates","volume":"50","author":"Adhikari","year":"2021","journal-title":"Int J Oral Maxillofac Surg"},{"key":"R14-20260106","doi-asserted-by":"crossref","first-page":"e0240352","DOI":"10.1371\/journal.pone.0240352","article-title":"Biomechanical evaluation of unilateral subcondylar fracture of the mandible on the varying materials: a finite element analysis","volume":"15","author":"Jung","year":"2020","journal-title":"PLoS One"},{"key":"R15-20260106","doi-asserted-by":"crossref","first-page":"1e14","DOI":"10.1016\/j.jtbi.2012.01.030","article-title":"Toward integration of geometric morphometrics and computational biomechanics: new methods for 3D virtual reconstruction and quantitative analysis of finite element models","volume":"301","author":"Parr","year":"2012","journal-title":"J Theoret Biol"},{"key":"R16-20260106","doi-asserted-by":"crossref","first-page":"2522e1","DOI":"10.1016\/j.joms.2019.07.012","article-title":"What is the most stable fixation technique for mandibular condyle fracture?","volume":"77","author":"Marwan","year":"2019","journal-title":"J Oral Maxillofac Surg"},{"key":"R17-20260106","doi-asserted-by":"crossref","first-page":"1026","DOI":"10.1016\/j.jcms.2021.01.026","article-title":"Comparison between 3D delta plate and conventional miniplate in treatment of condylar fracture: a randomised clinical trial","volume":"49","author":"Ganguly","year":"2021","journal-title":"J Craniomaxillofac Surg"},{"key":"R18-20260106","doi-asserted-by":"crossref","first-page":"84e90","DOI":"10.1016\/j.jcms.2006.11.006","article-title":"Development and biomechanical testing of a new osteosynthesis plate (TCP) designed to stabilize mandibular condyle fractures","volume":"35","author":"Meyer","year":"2007","journal-title":"J Craniomaxillofac Surg"},{"key":"R19-20260106","doi-asserted-by":"crossref","first-page":"665.e1","DOI":"10.1016\/j.joms.2020.09.038","article-title":"Finite element analysis of different titanium plates for internal fixation of fractures of the mandibular condylar neck","volume":"79","author":"Liokatis","year":"2021","journal-title":"J Oral Maxillofac Surg"},{"key":"R20-20260106","doi-asserted-by":"crossref","first-page":"2557","DOI":"10.1097\/SCS.0000000000007601","article-title":"Finite element analysis of two-and three-dimensional fixation in treating mandibular symphyseal fracture combined with bilateral condylar intracapsular fractures","volume":"32","author":"Zhou","year":"2021","journal-title":"J Craniof Surg"}],"container-title":["Journal of Craniofacial Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/SCS.0000000000012002","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,1,6]],"date-time":"2026-01-06T19:01:15Z","timestamp":1767726075000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/SCS.0000000000012002"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,10,2]]},"references-count":20,"journal-issue":{"issue":"8","published-print":{"date-parts":[[2025]]}},"URL":"https:\/\/doi.org\/10.1097\/scs.0000000000012002","relation":{},"ISSN":["1049-2275","1536-3732"],"issn-type":[{"value":"1049-2275","type":"print"},{"value":"1536-3732","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,10,2]]},"assertion":[{"value":"2025-08-18","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-08-24","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}