{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,16]],"date-time":"2026-01-16T16:01:31Z","timestamp":1768579291244,"version":"3.49.0"},"reference-count":26,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"4","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2010,7]]},"DOI":"10.1097\/scs.0b013e3181e62c5f","type":"journal-article","created":{"date-parts":[[2010,7,7]],"date-time":"2010-07-07T07:44:15Z","timestamp":1278488655000},"page":"1066-1068","source":"Crossref","is-referenced-by-count":35,"title":["Comparison of Collagen Membranes and Polydioxanone for Reconstruction of the Orbital Floor After Fractures"],"prefix":"10.1097","volume":"21","author":[{"given":"Stephan T.","family":"Becker","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hendrik","family":"Terheyden","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Michael","family":"Fabel","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Christian","family":"Kandzia","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Bj\u00f6rn","family":"M\u00f6ller","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"J\u00f6rg","family":"Wiltfang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","reference":[{"key":"R2-27-20210208","doi-asserted-by":"crossref","first-page":"1207","DOI":"10.1016\/S0161-6420(02)01057-6","article-title":"Clinical recommendations for repair of isolated orbital floor fractures: an evidence-based analysis.","volume":"109","author":"Burnstine","year":"2002","journal-title":"Ophthalmology"},{"key":"R3-27-20210208","doi-asserted-by":"crossref","first-page":"604","DOI":"10.1097\/00006534-199803000-00006","article-title":"Orbital reconstruction with individually copy-milled ceramic implants.","volume":"101","author":"Hoffmann","year":"1998","journal-title":"Plast Reconstr Surg"},{"key":"R4-27-20210208","doi-asserted-by":"crossref","first-page":"367","DOI":"10.1054\/ijom.2001.0219","article-title":"Orbital floor reconstruction with an alloplastic resorbable polydioxanone sheet.","volume":"31","author":"Baumann","year":"2002","journal-title":"Int J Oral Maxillofac Surg"},{"key":"R5-27-20210208","doi-asserted-by":"crossref","first-page":"646","DOI":"10.1016\/j.joms.2004.11.013","article-title":"Reconstruction of orbital floor fracture with polyglactin 910\/polydioxanon patch (Ethisorb): a retrospective study.","volume":"63","author":"Buchel","year":"2005","journal-title":"J Oral Maxillofac Surg"},{"key":"R6-27-20210208","doi-asserted-by":"crossref","first-page":"1709","DOI":"10.1097\/00006534-199905000-00023","article-title":"In situ splitting of a rib graft for reconstruction of the orbital floor.","volume":"103","author":"Johnson","year":"1999","journal-title":"Plast Reconstr Surg"},{"key":"R7-27-20210208","doi-asserted-by":"crossref","first-page":"240","DOI":"10.1016\/S0278-2391(97)90533-4","article-title":"Reconstruction of the orbital floor with lyophilized tensor fascia lata.","volume":"55","author":"Celikoz","year":"1997","journal-title":"J Oral Maxillofac Surg"},{"key":"R8-27-20210208","doi-asserted-by":"crossref","first-page":"242","DOI":"10.1097\/00001665-200105000-00009","article-title":"Resorbable mesh in the treatment of orbital floor fractures.","volume":"12","author":"Hollier","year":"2001","journal-title":"J Craniofac Surg"},{"issue":"suppl 1","key":"R9-27-20210208","first-page":"120","article-title":"Treatment of fractures of the orbital floor: reconstruction using Teflon sheets. Analysis of the results after 5 years.","volume":"99","author":"Ouadah","year":"1998","journal-title":"Rev Stomatol Chir Maxillofac"},{"key":"R10-27-20210208","first-page":"340","article-title":"Transplantation of homologous dura in reconstruction of the orbital floor. The results of five years experience.","volume":"4","author":"Luhr","year":"1973","journal-title":"Trans Int Conf Oral Surg"},{"key":"R11-27-20210208","first-page":"79","article-title":"Use of Lyodura in fractures of the orbital floor.","volume":"38","author":"Berrone","year":"1989","journal-title":"Minerva Stomatol"},{"key":"R12-27-20210208","doi-asserted-by":"crossref","first-page":"1036","DOI":"10.1001\/jama.257.8.1036","article-title":"Rapidly progressive dementia in a patient who received a cadaveric dura mater graft.","volume":"257","author":"Prichard","year":"1987","journal-title":"JAMA"},{"key":"R13-27-20210208","doi-asserted-by":"crossref","first-page":"82","DOI":"10.1054\/jcms.2000.0188","article-title":"Effectiveness of a new perforated 0.15 mm poly-p-dioxanon-foil versus titanium-dynamic mesh in reconstruction of the orbital floor.","volume":"29","author":"Dietz","year":"2001","journal-title":"J Craniomaxillofac Surg"},{"key":"R14-27-20210208","first-page":"186","article-title":"Resorbable synthetics (PDS foils) for bridging extensive orbital wall defects in an animal experiment comparison.","volume":"39","author":"Merten","year":"1994","journal-title":"Fortschr Kiefer Gesichtschir"},{"key":"R15-27-20210208","doi-asserted-by":"crossref","first-page":"442","DOI":"10.1016\/j.tripleo.2006.02.031","article-title":"Individual preformed titanium meshes for orbital fractures.","volume":"102","author":"Metzger","year":"2006","journal-title":"Oral Surg Oral Med Oral Pathol Oral Radiol Endod"},{"key":"R16-27-20210208","first-page":"1022","article-title":"Incorporation of titanium mesh in orbital and midface reconstruction.","volume":"110","author":"Schubert","year":"2002","journal-title":"Plast Reconstr Surg"},{"key":"R17-27-20210208","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1097\/00000637-200201000-00001","article-title":"Safety of titanium mesh for orbital reconstruction.","volume":"48","author":"Gear","year":"2002","journal-title":"Ann Plast Surg"},{"key":"R18-27-20210208","doi-asserted-by":"crossref","first-page":"1398","DOI":"10.1001\/archotol.124.12.1398","article-title":"Selection of materials for orbital floor reconstruction.","volume":"124","author":"Chowdhury","year":"1998","journal-title":"Arch Otolaryngol Head Neck Surg"},{"key":"R19-27-20210208","first-page":"504","article-title":"Guided bone regeneration using bone grafts and collagen membranes.","volume":"32","author":"Wang","year":"2001","journal-title":"Quintessence Int"},{"key":"R20-27-20210208","doi-asserted-by":"crossref","first-page":"443","DOI":"10.1111\/j.1600-0501.2004.01039.x","article-title":"Biocompatibility of various collagen membranes in cultures of human PDL fibroblasts and human osteoblast-like cells.","volume":"15","author":"Rothamel","year":"2004","journal-title":"Clin Oral Implants Res"},{"key":"R21-27-20210208","doi-asserted-by":"crossref","first-page":"968","DOI":"10.1097\/01.scs.0000186308.16795.8b","article-title":"Orbital floor restoration.","volume":"16","author":"Rinna","year":"2005","journal-title":"J Craniofac Surg"},{"key":"R22-27-20210208","doi-asserted-by":"crossref","first-page":"83","DOI":"10.1016\/S0901-5027(05)80712-X","article-title":"Reconstruction of orbital floor with polydioxanone plate.","volume":"20","author":"Iizuka","year":"1991","journal-title":"Int J Oral Maxillofac Surg"},{"key":"R23-27-20210208","doi-asserted-by":"crossref","first-page":"278","DOI":"10.1054\/ijom.2001.0067","article-title":"Effectiveness of operative treatment of internal orbital wall fracture with polydioxanone implant.","volume":"30","author":"Kontio","year":"2001","journal-title":"Int J Oral Maxillofac Surg"},{"key":"R24-27-20210208","doi-asserted-by":"crossref","first-page":"766","DOI":"10.1016\/j.ijom.2005.04.027","article-title":"Biodegradable polydioxanone and poly(L\/D)lactide implants: an experimental study on peri-implant tissue response.","volume":"34","author":"Kontio","year":"2005","journal-title":"Int J Oral Maxillofac Surg"},{"key":"R25-27-20210208","doi-asserted-by":"crossref","first-page":"834","DOI":"10.1097\/01.PRS.0000105335.41930.41","article-title":"Infraorbital nerve injury associated with zygoma fractures: documentation with neurosensory testing.","volume":"113","author":"Fogaca","year":"2004","journal-title":"Plast Reconstr Surg"},{"key":"R26-27-20210208","doi-asserted-by":"crossref","first-page":"19","DOI":"10.1007\/s10006-002-0439-7","article-title":"Post-traumatic ocular motility in orbital floor fractures.","volume":"7","author":"Jank","year":"2003","journal-title":"Mund Kiefer Gesichtschir"},{"key":"R27-27-20210208","doi-asserted-by":"crossref","first-page":"1267","DOI":"10.1053\/joms.2002.35722","article-title":"Evaluation of computer-based area and volume measurement from coronal computed tomography scans in isolated blowout fractures of the orbital floor.","volume":"60","author":"Ploder","year":"2002","journal-title":"J Oral Maxillofac Surg"}],"container-title":["Journal of Craniofacial Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/SCS.0b013e3181e62c5f","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,5,14]],"date-time":"2021-05-14T06:56:53Z","timestamp":1620975413000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/00001665-201007000-00027"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2010,7]]},"references-count":26,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2010]]}},"URL":"https:\/\/doi.org\/10.1097\/scs.0b013e3181e62c5f","relation":{},"ISSN":["1049-2275"],"issn-type":[{"value":"1049-2275","type":"print"}],"subject":[],"published":{"date-parts":[[2010,7]]}}}