{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,26]],"date-time":"2026-10-26T13:05:25Z","timestamp":1793019925450,"version":"4.5.0"},"reference-count":21,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"4","license":[{"start":{"date-parts":[[2023,4,10]],"date-time":"2023-04-10T00:00:00Z","timestamp":1681084800000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/ http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2023,10]]},"abstract":"<jats:sec>\n            <jats:title>Objective:<\/jats:title>\n            <jats:p>To present the first report of data from the Versius Surgical Registry, a prospective, multicenter data registry with ongoing collection across numerous surgical indications, developed to accompany the Versius Robotic Surgical System into clinical practice.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Background:<\/jats:title>\n            <jats:p>A data registry can be utilized to minimize risk to patients by establishing the safety and effectiveness of innovative medical devices and generating a thorough evidence base of real-world data.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods:<\/jats:title>\n            <jats:p>Surgical outcome data were collected and inputted through a secure online platform. Preoperative data included patient age, sex, body mass index, surgical history, and planned procedures. Intraoperative data included operative time, complications during surgery, conversion from robot-assisted surgery to an alternative surgical technique, and blood loss. Postoperative outcome data included length of hospital stay, complications following surgery, serious adverse events, return to the operating room, readmission to the hospital, and mortality within 90 days of surgery.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results:<\/jats:title>\n            <jats:p>This registry analysis included 2083 cases spanning general, colorectal, hernia, gynecologic, urological, and thoracic indications. A considerable number of cases were recorded for cholecystectomy (n=539), anterior resection (n=162), and total laparoscopic hysterocolpectomy (n=324) procedures. The rates of conversion to an alternative technique, serious adverse events, and 90-day mortality were low for all procedures across all surgical indications.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusions:<\/jats:title>\n            <jats:p>We report the large-scale analysis of the first 2083 cases recorded in this surgical registry, with substantial data collected for cholecystectomies, anterior resections, and total laparoscopic hysterectomies. The extensive surgical outcome data reported here provide real-world evidence for the safe implementation of the surgical robot into clinical practice.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/sla.0000000000005871","type":"journal-article","created":{"date-parts":[[2023,4,10]],"date-time":"2023-04-10T12:00:43Z","timestamp":1681128043000},"page":"e903-e910","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":46,"title":["Safe Implementation of a Next-Generation Surgical Robot"],"prefix":"10.1097","volume":"278","author":[{"given":"Ilias","family":"Soumpasis","sequence":"first","affiliation":[{"name":"CMR Surgical, Cambridge, UK"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Samer","family":"Nashef","sequence":"additional","affiliation":[{"name":"Royal Papworth Hospital, Cardiac Surgery Department, Cambridge Biomedical Campus, Cambridge, UK"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Joel","family":"Dunning","sequence":"additional","affiliation":[{"name":"Department of Cardiothoracic Surgery, James Cook University Hospital, Middlesbrough, UK"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Paul","family":"Moran","sequence":"additional","affiliation":[{"name":"Department of Obstetrics and Gynaecology, Worcestershire Royal Hospital, Worcestershire Acute Hospitals NHS Trust, Worcester, UK"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mark","family":"Slack","sequence":"additional","affiliation":[{"name":"CMR Surgical, Cambridge, UK"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2023,4,10]]},"reference":[{"key":"R1-20250503","doi-asserted-by":"crossref","first-page":"595","DOI":"10.1056\/NEJMp1712001","article-title":"Medical devices in the real world","volume":"378","author":"Resnic","year":"2018","journal-title":"N Engl J Med"},{"key":"R2-20250503","doi-asserted-by":"crossref","first-page":"211","DOI":"10.1097\/SLA.0000000000002794","article-title":"No surgical innovation without evaluation: evolution and further development of the IDEAL framework and recommendations","volume":"269","author":"Hirst","year":"2019","journal-title":"Ann Surg"},{"key":"R3-20250503","doi-asserted-by":"crossref","first-page":"1105","DOI":"10.1016\/S0140-6736(09)61116-8","article-title":"No surgical innovation without evaluation: the IDEAL recommendations","volume":"374","author":"McCulloch","year":"2009","journal-title":"Lancet"},{"key":"R4-20250503","doi-asserted-by":"crossref","first-page":"i2372","DOI":"10.1136\/bmj.i2372","article-title":"IDEAL-D: a rational framework for evaluating and regulating the use of medical devices","volume":"353","author":"Sedrakyan","year":"2016","journal-title":"BMJ"},{"key":"R5-20250503","doi-asserted-by":"crossref","first-page":"e000019","DOI":"10.1136\/bmjsit-2019-000019","article-title":"Using end-user feedback to optimize the design of the Versius Surgical System, a new robot-assisted device for use in minimal access surgery.","volume":"1","author":"Hares","year":"2019","journal-title":"BMJ Surg Interv Health Technol"},{"key":"R6-20250503","doi-asserted-by":"crossref","first-page":"e000028","DOI":"10.1136\/bmjsit-2019-000028","article-title":"Usability assessment of Versius, a new robot-assisted surgical device for use in minimal access surgery","volume":"2","author":"Haig","year":"2020","journal-title":"BMJ Surg Interv Health Technol"},{"key":"R7-20250503","doi-asserted-by":"crossref","first-page":"ezac178","DOI":"10.1093\/ejcts\/ezac178","article-title":"Preclinical evaluation of Versius, an innovative device for use in robot-assisted thoracic surgery","volume":"62","author":"Aresu","year":"2022","journal-title":"Eur J Cardiothorac Surg"},{"key":"R8-20250503","doi-asserted-by":"crossref","first-page":"2","DOI":"10.1186\/s10397-020-01069-0","article-title":"Preclinical evaluation of a new robot-assisted surgical system for use in gynecology minimal access surgery","volume":"17","author":"Carey","year":"2020","journal-title":"Gynecol Surg"},{"key":"R9-20250503","doi-asserted-by":"crossref","first-page":"2169","DOI":"10.1007\/s00464-020-07622-4","article-title":"Preclinical evaluation of the versius surgical system, a new robot-assisted surgical device for use in minimal access general and colorectal procedures","volume":"35","author":"Morton","year":"2021","journal-title":"Surg Endosc"},{"key":"R10-20250503","doi-asserted-by":"crossref","first-page":"444","DOI":"10.1016\/j.euf.2020.01.011","article-title":"Preclinical evaluation of the versius surgical system, a New Robot-assisted surgical device for use in minimal access renal and prostate surgery","volume":"7","author":"Thomas","year":"2021","journal-title":"Eur Urol Focus"},{"key":"R11-20250503","doi-asserted-by":"crossref","first-page":"978","DOI":"10.1111\/aogs.14407","article-title":"Early evaluation of a next generation surgical system in robot assisted total laparoscopic hysterectomy: a prospective clinical cohort study","volume":"101","author":"Borse","year":"2022","journal-title":"Acta Obstet Gynecol Scand"},{"key":"R12-20250503","doi-asserted-by":"crossref","first-page":"9","DOI":"10.1097\/SLA.0000000000005410","article-title":"An early prospective clinical study to evaluate the safety and performance of the versius surgical system in robot-assisted cholecystectomy","volume":"277","author":"Kelkar","year":"2023","journal-title":"Ann Surg"},{"key":"R14-20250503","doi-asserted-by":"crossref","first-page":"111","DOI":"10.4103\/0019-5049.79879","article-title":"American Society of Anaesthesiologists physical status classification","volume":"55","author":"Daabiss","year":"2011","journal-title":"Indian J Anaesth"},{"key":"R15-20250503","doi-asserted-by":"crossref","first-page":"205","DOI":"10.1097\/01.sla.0000133083.54934.ae","article-title":"Classification of surgical complications: a new proposal with evaluation in a cohort of 6336 patients and results of a survey","volume":"240","author":"Dindo","year":"2004","journal-title":"Ann Surg"},{"key":"R16-20250503","doi-asserted-by":"crossref","first-page":"151","DOI":"10.1186\/s12893-021-01152-z","article-title":"Evaluation of the conversion rate as it relates to preoperative risk factors and surgeon experience: a retrospective study of 4013 patients undergoing elective laparoscopic cholecystectomy","volume":"21","author":"\u00c1brah\u00e1m","year":"2021","journal-title":"BMC Surg"},{"key":"R17-20250503","doi-asserted-by":"crossref","first-page":"A136","DOI":"10.1016\/j.jval.2016.03.1640","article-title":"Comparison of conversion rates between robotic-assisted and laparoscopic anterior rectal resection for rectal cancer: which patients and providers could benefit most from robotic-assisted surgery?","volume":"19","author":"Ackerman","year":"2016","journal-title":"Value Health"},{"key":"R18-20250503","doi-asserted-by":"crossref","first-page":"1021","DOI":"10.1007\/s00464-017-5780-x","article-title":"Surgical volume and conversion rate in laparoscopic hysterectomy: does volume matter? A multicenter retrospective cohort study","volume":"32","author":"Keurentjes","year":"2018","journal-title":"Surg Endosc"},{"key":"R19-20250503","doi-asserted-by":"crossref","first-page":"318","DOI":"10.1016\/j.ijsu.2011.02.003","article-title":"Risk factors in laparoscopic cholecystectomy: a multivariate analysis","volume":"9","author":"Kanakala","year":"2011","journal-title":"Int J Surg"},{"key":"R20-20250503","doi-asserted-by":"crossref","first-page":"310","DOI":"10.1002\/bjs5.50254","article-title":"Nationwide in-hospital mortality rate following rectal resection for rectal cancer according to annual hospital volume in Germany","volume":"4","author":"Diers","year":"2020","journal-title":"BJS Open"},{"key":"R21-20250503","doi-asserted-by":"crossref","first-page":"603","DOI":"10.1016\/j.jmig.2019.10.005","article-title":"Mortality rates in benign laparoscopic and robotic gynecologic surgery: a systematic review and meta-analysis","volume":"27","author":"Behbehani","year":"2020","journal-title":"J Minim Invasive Gynecol"},{"key":"R22-20250503","first-page":"53","article-title":"Use of cumulative summation (CUSUM) as a tool for early feedback and monitoring in robot-assisted radical prostatectomy outcomes and performance","volume":"13","author":"Chan","year":"2019","journal-title":"Can Urol Assoc J"}],"container-title":["Annals of Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/SLA.0000000000005871","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,5,3]],"date-time":"2025-05-03T04:02:39Z","timestamp":1746244959000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/SLA.0000000000005871"}},"subtitle":["First Analysis of 2,083 Cases in the Versius Surgical Registry"],"short-title":[],"issued":{"date-parts":[[2023,4,10]]},"references-count":21,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2023]]}},"URL":"https:\/\/doi.org\/10.1097\/sla.0000000000005871","relation":{},"ISSN":["0003-4932"],"issn-type":[{"value":"0003-4932","type":"print"}],"subject":[],"published":{"date-parts":[[2023,4,10]]}}}