{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2023,10,2]],"date-time":"2023-10-02T08:11:17Z","timestamp":1696234277967},"reference-count":11,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"5","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2018,10]]},"abstract":"<jats:p>Common bile duct (CBD) suturing is a difficult procedure in laparoscopic CBD exploration. We sought to develop a simpler CBD suture technique using running barbed sutures. We retrospectively compared 2 suture techniques for CBD closure after T-tube placement. The barbed group comprised of 46 patients who underwent CBD closure using running barbed sutures, whereas the standard group comprised of 39 patients who received interrupted sutures. Mean CBD suturing time (6.2\u00b10.9 vs. 12.2\u00b11.1\u2009min; <jats:italic toggle=\"yes\">P<\/jats:italic>&lt;0.001), total operating time (79.7\u00b19.4 vs. 90.8\u00b112.4\u2009min; <jats:italic toggle=\"yes\">P<\/jats:italic>&lt;0.001), and hospital stay (6.1\u00b11.8 vs. 7.0\u00b11.7\u2009d; <jats:italic toggle=\"yes\">P<\/jats:italic>=0.024) were significantly shorter and less patients experienced leakage after T-tube flushing (<jats:italic toggle=\"yes\">P<\/jats:italic>=0.041) with the barbed suture technique. There were 2 cases of postoperative bile leakage in the standard group, with no statistical significance. The running barbed suture technique is safe and effective for CBD closure, which can decrease operating time and risk of complications.<\/jats:p>","DOI":"10.1097\/sle.0000000000000566","type":"journal-article","created":{"date-parts":[[2018,8,1]],"date-time":"2018-08-01T21:36:34Z","timestamp":1533159394000},"page":"324-327","source":"Crossref","is-referenced-by-count":0,"title":["Application of Barbed Sutures in Laparoscopic Common Bile Duct Exploration: A Retrospective Analysis"],"prefix":"10.1097","volume":"28","author":[{"given":"Xiangdong","family":"Liu","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"De","family":"Luo","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hong","family":"Chen","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jiang","family":"Liu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Fangyi","family":"Peng","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Cheng","family":"Fang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Bo","family":"Li","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Song","family":"Su","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","reference":[{"key":"R1-20231001","doi-asserted-by":"crossref","first-page":"2165","DOI":"10.1007\/s00464-012-2194-7","article-title":"Laparoscopic common bile duct exploration versus open surgery: comparative prospective randomized trial","volume":"26","author":"Grubnik","year":"2012","journal-title":"Surg Endosc"},{"key":"R2-20231001","doi-asserted-by":"crossref","first-page":"833","DOI":"10.1016\/j.jamcollsurg.2017.01.062","article-title":"Outcomes of laparoscopic vs open common bile duct exploration: analysis of the NSQIP database","volume":"224","author":"Halawani","year":"2017","journal-title":"J Am Coll Surg"},{"key":"R3-20231001","doi-asserted-by":"crossref","first-page":"502","DOI":"10.1097\/SLE.0b013e318290144b","article-title":"A laparoscopic approach to CBD stones","volume":"23","author":"Khanzada","year":"2013","journal-title":"Surg Laparosc Endosc Percutan Tech"},{"key":"R4-20231001","doi-asserted-by":"crossref","first-page":"1360","DOI":"10.1007\/s00464-012-2616-6","article-title":"Hand-sewn gastrojejunostomy using knotless unidirectional barbed absorbable suture during laparoscopic gastric bypass","volume":"27","author":"Tyner","year":"2013","journal-title":"Surg Endosc"},{"key":"R5-20231001","doi-asserted-by":"crossref","first-page":"218","DOI":"10.1016\/j.jmig.2011.01.002","article-title":"Decreased incidence of vaginal cuff dehiscence after laparoscopic closure with bidirectional barbed suture","volume":"18","author":"Siedhoff","year":"2011","journal-title":"J Minim Invasive Gynecol"},{"key":"R6-20231001","first-page":"1","article-title":"Comparison of barbed unidirectional suture with figure-of-eight standard sutures in vaginal cuff closure in total laparoscopic hysterectomy","volume":"24","author":"Karacan","year":"2018","journal-title":"J Obstet Gynaecol"},{"key":"R7-20231001","doi-asserted-by":"crossref","first-page":"125","DOI":"10.1007\/s11255-011-9967-0","article-title":"Impact of newer unidirectional and bidirectional barbed suture on vesicourethral anastomosis during robot-assisted radical prostatectomy and its comparison with polyglecaprone-25 suture: an initial experience","volume":"44","author":"Hemal","year":"2012","journal-title":"Int Urol Nephrol"},{"key":"R8-20231001","doi-asserted-by":"crossref","first-page":"267","DOI":"10.1177\/1553350618765871","article-title":"The use of barbed suture for intracorporeal mechanical anastomosis during a totally laparoscopic right colectomy: is it safe? a retrospective nonrandomized comparative multicenter study","volume":"25","author":"Bracale","year":"2018","journal-title":"Surg Innov"},{"key":"R9-20231001","doi-asserted-by":"crossref","first-page":"887","DOI":"10.1089\/lap.2014.0053","article-title":"Laparoscopic pancreaticojejunostomy using a barbed suture: a novel technique","volume":"24","author":"Edil","year":"2014","journal-title":"J Laparoendosc Adv Surg Tech A"},{"key":"R10-20231001","doi-asserted-by":"crossref","first-page":"221","DOI":"10.1016\/j.asj.2009.01.009","article-title":"Abdominoplasty with progressive tension closure using a barbed suture technique","volume":"29","author":"Warner","year":"2009","journal-title":"Aesthet Surg J"},{"key":"R11-20231001","doi-asserted-by":"crossref","first-page":"1699","DOI":"10.1007\/s00464-015-4395-3","article-title":"Enterotomy closure using knotless and barbed suture in laparoscopic upper gastrointestinal surgeries","volume":"30","author":"Bautista","year":"2016","journal-title":"Surg Endosc"}],"container-title":["Surgical Laparoscopy, Endoscopy &amp; Percutaneous Techniques"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/00129689-201810000-00012","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,1]],"date-time":"2023-10-01T03:17:08Z","timestamp":1696130228000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/00129689-201810000-00012"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,10]]},"references-count":11,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2018]]}},"URL":"https:\/\/doi.org\/10.1097\/sle.0000000000000566","relation":{},"ISSN":["1530-4515"],"issn-type":[{"value":"1530-4515","type":"print"}],"subject":[],"published":{"date-parts":[[2018,10]]}}}