{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,8,21]],"date-time":"2025-08-21T16:53:45Z","timestamp":1755795225595,"version":"3.44.0"},"reference-count":31,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"3","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"abstract":"<jats:sec>\n            <jats:title>Background:<\/jats:title>\n            <jats:p>Robotic ventral hernia repair has been increasing globally, with comparable outcomes to laparoscopic repair and lower rates of conversion to open surgery. Robotic surgery is increasing in popularity, and there is a number of new robotic systems entering the marketing. We report the first case of a Roboic eTEP using the Versius robotic system in a patient with an incisional hernia.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods:<\/jats:title>\n            <jats:p>Surgery was performed using the Versius system from CMR surgical which consists of bedside units for each instrument and a console. The patient presented with an incisional hernia measuring 9.5\u00d75\u00a0cm in the left flank.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results:<\/jats:title>\n            <jats:p>The patient was discharged on postoperative day (POD) 2 with a drain. There was no need for opioids. The drain was removed at POD 7. The patient presented at POD 10 with erythema and cellulitis in the area that previously had tape on it, and it was resolved with a short course of oral antibiotics.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusion:<\/jats:title>\n            <jats:p>The eTEP technique for hernia surgery was safe and feasible using the Versius robotic system. Implementation is possible in experienced hands with minimal changes to the surgical techniques.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/sle.0000000000001231","type":"journal-article","created":{"date-parts":[[2024,5,16]],"date-time":"2024-05-16T08:00:55Z","timestamp":1715846455000},"page":"330-333","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":0,"title":["Implementation of the Versius Surgical System in Complex Abdominal Wall Repair: First Reported Case of an Robotic ETEP\/TAR Procedure"],"prefix":"10.1097","volume":"34","author":[{"given":"Renato D.","family":"Pinto","sequence":"first","affiliation":[{"name":"Hospital Unimed Litoral, Balneario Camboriu, Santa Catarina"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Pedro","family":"Trauczynski","sequence":"additional","affiliation":[{"name":"Hospital Santa Isabel, Blumenau"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Diego L.","family":"Lima","sequence":"additional","affiliation":[{"name":"Montefiore Medical Center, The Bronx, NY"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Leandro T.","family":"Cavazzola","sequence":"additional","affiliation":[{"name":"Department of Surgery, Universidade Federal do Rio Grande do Sul, Rio Grande do Sul, Brazil"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","published-online":{"date-parts":[[2024,6]]},"reference":[{"key":"R1-20250817","first-page":"39","article-title":"Laparoscopic repair of incisional abdominal hernias using expanded polytetrafluoroethylene: preliminary findings","volume":"3","author":"LeBlanc","year":"1993","journal-title":"Surg Laparosc Endosc"},{"key":"R2-20250817","doi-asserted-by":"crossref","first-page":"391","DOI":"10.1097\/01.sla.0000086662.49499.ab","article-title":"Laparoscopic repair of ventral hernias: nine years\u2019 experience with 850 consecutive hernias","volume":"238","author":"Heniford","year":"2003","journal-title":"Ann Surg"},{"key":"R3-20250817","doi-asserted-by":"crossref","first-page":"827","DOI":"10.1177\/000313489906500905","article-title":"Comparison of laparoscopic and open ventral herniorrhaphy","volume":"65","author":"Ramshaw","year":"1999","journal-title":"Am Surg"},{"key":"R4-20250817","doi-asserted-by":"crossref","first-page":"322","DOI":"10.1001\/archsurg.2010.18","article-title":"Comparison of laparoscopic and open repair with mesh for the treatment of ventral incisional hernia: a randomized trial","volume":"145","author":"Itani","year":"2010","journal-title":"Arch Surg"},{"key":"R5-20250817","doi-asserted-by":"crossref","first-page":"1187","DOI":"10.1007\/s00464-011-1993-6","article-title":"The enhanced view-totally extraperitoneal technique for repair of inguinal hernia","volume":"26","author":"Daes","year":"2012","journal-title":"Surg Endosc"},{"key":"R7-20250817","doi-asserted-by":"crossref","first-page":"545","DOI":"10.1007\/BF01658869","article-title":"The treatment of complicated groin and incisional hernias","volume":"13","author":"Stoppa","year":"1989","journal-title":"World J Surg"},{"key":"R8-20250817","doi-asserted-by":"crossref","first-page":"283","DOI":"10.1016\/j.jamcollsurg.2006.05.297","article-title":"Open preperitoneal retrofascial mesh repair for multiply recurrent ventral incisional hernias","volume":"203","author":"Novitsky","year":"2006","journal-title":"J Am Coll Surg"},{"key":"R9-20250817","doi-asserted-by":"crossref","first-page":"190","DOI":"10.1097\/SAP.0b013e318212f380","article-title":"Modified Rives-Stoppa technique for repair of complex incisional hernias in 59 patients","volume":"68","author":"Maman","year":"2012","journal-title":"Ann Plast Surg"},{"key":"R10-20250817","doi-asserted-by":"crossref","first-page":"1525","DOI":"10.1007\/s00464-017-5840-2","article-title":"A novel approach using the enhanced-view totally extraperitoneal (eTEP) technique for laparoscopic retromuscular hernia repair","volume":"32","author":"Belyansky","year":"2018","journal-title":"Surg Endosc"},{"key":"R11-20250817","doi-asserted-by":"crossref","first-page":"837","DOI":"10.1007\/s10029-018-1795-z","article-title":"Early operative outcomes of endoscopic (eTEP access) robotic-assisted retromuscular abdominal wall hernia repair","volume":"22","author":"Belyansky","year":"2018","journal-title":"Hernia"},{"key":"R12-20250817","doi-asserted-by":"crossref","first-page":"3597","DOI":"10.1007\/s00464-019-07132-y","article-title":"Comparative review of outcomes: laparoscopic and robotic enhanced-view totally extraperitoneal (eTEP) access retrorectus repairs","volume":"34","author":"Lu","year":"2020","journal-title":"Surg Endosc"},{"key":"R13-20250817","doi-asserted-by":"crossref","first-page":"3749","DOI":"10.1007\/s00464-019-06669-2","article-title":"Endoscopic enhanced-view totally extraperitoneal retromuscular approach for ventral hernia repair","volume":"33","author":"Penchev","year":"2019","journal-title":"Surg Endosc"},{"key":"R14-20250817","doi-asserted-by":"crossref","first-page":"945","DOI":"10.1007\/s10029-019-01931-x","article-title":"The endoscopic retromuscular repair of ventral hernia: the eTEP technique and early results","volume":"23","author":"Radu","year":"2019","journal-title":"Hernia"},{"key":"R15-20250817","doi-asserted-by":"crossref","first-page":"527","DOI":"10.1007\/s10029-019-02076-7","article-title":"Precostal top-down extended totally extraperitoneal ventral hernia plasty (eTEP): simplification of a complex technical approach","volume":"24","author":"K\u00f6hler","year":"2020","journal-title":"Hernia"},{"key":"R16-20250817","first-page":"533","article-title":"Laparoscopic enhanced-view totally extraperitoneal Rives-Stoppa repair (eTEP-RS) for ventral and incisional hernias - early operative outcomes and technical remarks on a novel retromuscular approach","volume":"15","author":"Mitura","year":"2020","journal-title":"Wideochir Inne Tech Maloinwazyjne"},{"key":"R17-20250817","doi-asserted-by":"crossref","first-page":"9","DOI":"10.1097\/SLA.0000000000004964","article-title":"Robotic ventral hernia repair: lessons learned from a 7-year experience","volume":"275","author":"Kudsi","year":"2021","journal-title":"Ann Surg"},{"key":"R18-20250817","doi-asserted-by":"crossref","first-page":"1955","DOI":"10.1007\/s13304-021-01067-7","article-title":"Extended totally extraperitoneal Rives-Stoppa (eTEP-RS) technique for ventral hernia: initial experience of The Wall Hernia Group and a surgical technique update","volume":"73","author":"Andreuccetti","year":"2021","journal-title":"Updates Surg"},{"key":"R19-20250817","doi-asserted-by":"crossref","first-page":"1061","DOI":"10.1007\/s10029-021-02373-0","article-title":"Endoscopic retromuscular technique (eTEP) vs conventional laparoscopic ventral or incisional hernia repair with defect closure (IPOM+) for midline hernias. A case-control study","volume":"25","author":"Bellido Luque","year":"2021","journal-title":"Hernia"},{"key":"R20-20250817","doi-asserted-by":"crossref","first-page":"1500","DOI":"10.1007\/s00464-021-08436-8","article-title":"Laparoscopic intraperitoneal versus enhanced-view totally extraperitoneal retromuscular mesh repair for ventral hernia: a retrospective cohort study","volume":"36","author":"Bui","year":"2022","journal-title":"Surg Endosc"},{"key":"R21-20250817","doi-asserted-by":"crossref","first-page":"519","DOI":"10.4103\/jmas.JMAS_145_20","article-title":"Comparison of efficacy and safety of the enhanced-view totally extraperitoneal (eTEP) and transabdominal (TARM) minimal access techniques for retromuscular placement of prosthesis in the treatment of irreducible midline ventral hernia","volume":"17","author":"Rege","year":"2021","journal-title":"J Minim Access Surg"},{"key":"R22-20250817","doi-asserted-by":"crossref","first-page":"1635","DOI":"10.1007\/s10029-021-02397-6","article-title":"e-TEP repair for midline primary and incisional hernia: technical considerations and initial experience","volume":"25","author":"Khetan","year":"2021","journal-title":"Hernia"},{"key":"R23-20250817","doi-asserted-by":"crossref","first-page":"5072","DOI":"10.1007\/s00464-020-07990-x","article-title":"A comparative prospective study of short-term outcomes of extended view totally extraperitoneal (e-TEP) repair versus laparoscopic intraperitoneal on lay mesh (IPOM) plus repair for ventral hernia","volume":"35","author":"Kumar","year":"2021","journal-title":"Surg Endosc"},{"key":"R24-20250817","doi-asserted-by":"crossref","first-page":"765","DOI":"10.1007\/s10029-020-02233-3","article-title":"Robotic assisted eTEP ventral hernia repair: Brazilian early experience","volume":"25","author":"Morrell","year":"2021","journal-title":"Hernia"},{"key":"R25-20250817","doi-asserted-by":"crossref","first-page":"2005","DOI":"10.1007\/s00464-020-07595-4","article-title":"Extended view: totally extra peritoneal (e-TEP) approach for ventral and incisional hernia-early results from a single center","volume":"35","author":"Prakhar","year":"2021","journal-title":"Surg Endosc"},{"key":"R26-20250817","doi-asserted-by":"crossref","first-page":"632","DOI":"10.1007\/s00464-021-08330-3","article-title":"Enhanced-view totally extraperitoneal (eTEP) approach for the treatment of abdominal wall hernias: mid-term results","volume":"36","author":"Quezada","year":"2022","journal-title":"Surg Endosc"},{"key":"R27-20250817","doi-asserted-by":"crossref","first-page":"565","DOI":"10.1007\/s11701-022-01451-4","article-title":"Implementation of robotic hernia surgery using the Versius system","volume":"17","author":"Dixon","year":"2022","journal-title":"J Robot Surg"},{"key":"R28-20250817","doi-asserted-by":"crossref","first-page":"1565","DOI":"10.1007\/s10029-021-02501-w","article-title":"Robotic versus laparoscopic ventral hernia repair: a systematic review and meta-analysis of randomised controlled trials and propensity score matched studies","volume":"25","author":"Mohan","year":"2021","journal-title":"Hernia"},{"key":"R29-20250817","doi-asserted-by":"crossref","first-page":"e20202879","DOI":"10.1590\/0100-6991e-20202879","article-title":"Image Inversion during Xi Robotic ventral hernia repair: making it even more effective","volume":"48","author":"Morrell","year":"2021","journal-title":"Rev Col Bras Cir"},{"key":"R30-20250817","doi-asserted-by":"crossref","first-page":"3754","DOI":"10.3390\/jcm11133754","article-title":"Assessment of the versius robotic surgical system in minimal access surgery: a systematic review","volume":"11","author":"Alkatout","year":"2022","journal-title":"J Clin Med"},{"key":"R31-20250817","doi-asserted-by":"crossref","first-page":"419","DOI":"10.1007\/s11701-022-01422-9","article-title":"Transition from da Vinci to Versius robotic surgical system: initial experience and outcomes of over 100 consecutive procedures","volume":"17","author":"Hussein","year":"2022","journal-title":"J Robot Surg"},{"key":"R32-20250817","doi-asserted-by":"crossref","first-page":"841","DOI":"10.1007\/s11701-022-01471-0","article-title":"Initial experience with a novel robotic surgical system in abdominal surgery","volume":"17","author":"El Dahdah","year":"2022","journal-title":"J Robot Surg"}],"container-title":["Surgical Laparoscopy, Endoscopy &amp; Percutaneous Techniques"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/SLE.0000000000001231","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,8,17]],"date-time":"2025-08-17T16:02:04Z","timestamp":1755446524000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/SLE.0000000000001231"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,5,16]]},"references-count":31,"journal-issue":{"issue":"3","published-online":{"date-parts":[[2024]]}},"URL":"https:\/\/doi.org\/10.1097\/sle.0000000000001231","relation":{},"ISSN":["1534-4908"],"issn-type":[{"type":"electronic","value":"1534-4908"}],"subject":[],"published":{"date-parts":[[2024,5,16]]},"assertion":[{"value":"2023-07-11","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2023-08-22","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}