{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,15]],"date-time":"2026-10-15T17:45:31Z","timestamp":1792086331445,"version":"4.4.0"},"reference-count":22,"publisher":"Ovid Technologies (Wolters Kluwer Health)","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"abstract":"<jats:sec>\n                    <jats:title>Background and Aims:<\/jats:title>\n                    <jats:p>Unsedated colonoscopy often increases procedural pain and prolongs insertion time, especially in the sigmoid colon with acute luminal angulation. This study aimed to evaluate the efficacy and safety of preprocedural enhanced oral water intake (PWI) for unsedated colonoscopy.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>This randomized controlled trial (RCT) enrolled 372 eligible patients. They were randomized to the conventional air colonoscopy (CAC), water-assisted colonoscopy (WAC), and PWI groups to receive the assigned interventions. Primary outcomes included insertion time, visual analog scale (VAS), cecal intubation rate, bowel cleanliness, and adenoma detection rate (ADR).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>\n                      All 3 groups achieved a cecal intubation rate of 100.0%. The ADR was comparable among the 3 groups, with no statistically significant difference (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      =0.702). VAS scores in the CAC group were significantly higher than those in the WAC and PWI groups (4.15\u00b11.68 vs. 2.64\u00b11.99 and 2.65\u00b11.97;\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt;0.001, 95% CI: 1.049-1.968 and 95% CI: 1.035-1.949), whereas no statistically significant difference was found between the WAC and PWI groups (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      =0.949, 95% CI: \u22120.510 to 0.478). Compared with CAC (2.00\u00a0min) and WAC (2.55\u00a0min), the PWI group exhibited a shorter median insertion time (1.60\u00a0min, all\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt;0.001). The Hodges-Lehmann median differences were \u22120.80 minutes (95% CI: \u22121.00 to \u22120.50\u00a0min, PWI vs. CAC) and 1.20 minutes (95% CI: 1.00-1.50\u00a0min, WAC vs. PWI). Willingness to undergo repeat colonoscopy was comparable between WAC and PWI (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      =0.820), but significantly higher in these 2 groups than in the CAC group (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      =0.017).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions:<\/jats:title>\n                    <jats:p>PWI appears to be associated with shorter insertion time among patients undergoing unsedated colonoscopy.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1097\/sle.0000000000001516","type":"journal-article","created":{"date-parts":[[2026,10,15]],"date-time":"2026-10-15T17:00:09Z","timestamp":1792083609000},"update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":0,"title":["Minimal Oral Water Immersion Method May Shorten Insertion Time During Unsedated Colonoscopy: A Randomized Controlled Trial"],"prefix":"10.1097","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-5870-3188","authenticated-orcid":false,"given":"Jinqing","family":"Wu","sequence":"first","affiliation":[{"name":"Taikang Xianlin Drum Tower Hospital, Affiliated Hospital of Medical School, Nanjing University, Nanjing, China"},{"name":"Department of Gastroenterology"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Haofeng","family":"Xu","sequence":"additional","affiliation":[{"name":"Department of Gastroenterology"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xue","family":"Li","sequence":"additional","affiliation":[{"name":"Department of Hematology, Fuyang People\u2019s Hospital, Fuyang, Anhui, China"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2026,10,1]]},"reference":[{"key":"R1-20261015","first-page":"e1412","article-title":"Cold snare biopsy to increase diagnostic accuracy in patients with suspected colorectal cancer under colonoscopy","volume":"35","author":"Wu","year":"2025","journal-title":"Surg Laparosc Endosc Percutan Tech"},{"key":"R2-20261015","doi-asserted-by":"crossref","first-page":"402","DOI":"10.1016\/j.gie.2024.07.010","article-title":"Prospective randomized controlled trial of water exchange plus cap versus water exchange colonoscopy in unsedated veterans","volume":"101","author":"Leung","year":"2025","journal-title":"Gastrointest Endosc"},{"key":"R3-20261015","doi-asserted-by":"crossref","first-page":"845","DOI":"10.1136\/gutjnl-2020-321918","article-title":"WASh trial team. WASh multicentre randomized controlled trial: water-assisted sigmoidoscopy in English NHS bowel scope screening","volume":"70","author":"Rutter","year":"2021","journal-title":"Gut"},{"key":"R4-20261015","doi-asserted-by":"crossref","first-page":"324","DOI":"10.1055\/a-1929-4552","article-title":"Minimal water exchange by the air-water valve versus left colon water exchange in unsedated colonoscopy: a randomized controlled trial","volume":"55","author":"Liu","year":"2023","journal-title":"Endoscopy"},{"key":"R5-20261015","doi-asserted-by":"crossref","first-page":"1326","DOI":"10.1111\/jgh.15869","article-title":"Factors associated with prolonged cecal insertion time in patients undergoing water exchange colonoscopy","volume":"37","author":"Hsieh","year":"2022","journal-title":"J Gastroenterol Hepatol"},{"key":"R6-20261015","doi-asserted-by":"crossref","first-page":"159","DOI":"10.1016\/j.gie.2018.07.020","article-title":"Impact of water exchange colonoscopy on endoscopy room efficiency: a systematic review and meta-analysis","volume":"89","author":"Cadoni","year":"2019","journal-title":"Gastrointest Endosc"},{"key":"R7-20261015","doi-asserted-by":"crossref","first-page":"e00594","DOI":"10.14309\/ctg.0000000000000594","article-title":"Randomized trial comparing left colon mucus production using water versus saline during water exchange colonoscopy","volume":"14","author":"Cheng","year":"2023","journal-title":"Clin Transl Gastroenterol"},{"key":"R8-20261015","doi-asserted-by":"crossref","first-page":"230","DOI":"10.1177\/2050640618817105","article-title":"Reduction of multitasking distractions underlies the higher adenoma detection rate of water exchange compared to air insufflation - blinded analysis of withdrawal phase videos","volume":"7","author":"Hsieh","year":"2019","journal-title":"United European Gastroenterol J"},{"key":"R9-20261015","doi-asserted-by":"crossref","first-page":"560","DOI":"10.1053\/j.gastro.2024.03.018","article-title":"Relative efficacies of interventions to improve the quality of screening-related colonoscopy: a systematic review and network meta-analysis of randomized controlled trials","volume":"167","author":"Khan","year":"2024","journal-title":"Gastroenterology"},{"key":"R10-20261015","doi-asserted-by":"crossref","first-page":"775","DOI":"10.1055\/a-0959-0505","article-title":"Bowel preparation for colonoscopy: European Society of Gastrointestinal Endoscopy (ESGE) Guideline-Update 2019","volume":"51","author":"Hassan","year":"2019","journal-title":"Endoscopy"},{"key":"R11-20261015","doi-asserted-by":"crossref","first-page":"141","DOI":"10.1055\/a-2681-5544","article-title":"Efficacy of artificial intelligence for adenoma detection in water exchange colonoscopy: a two-center randomized controlled trial","volume":"58","author":"Cheng","year":"2026","journal-title":"Endoscopy"},{"key":"R12-20261015","doi-asserted-by":"crossref","first-page":"507","DOI":"10.1080\/00365521.2021.2018488","article-title":"Feasibility of salvage colonoscopy by water exchange for failed air-insufflated patients: a prospective, randomized, controlled trial","volume":"57","author":"Wang","year":"2022","journal-title":"Scand J Gastroenterol"},{"key":"R13-20261015","doi-asserted-by":"crossref","first-page":"456","DOI":"10.1055\/s-0043-101229","article-title":"Water exchange for screening colonoscopy increases adenoma detection rate: a multicenter, double-blinded, randomized controlled trial","volume":"49","author":"Cadoni","year":"2017","journal-title":"Endoscopy"},{"key":"R14-20261015","doi-asserted-by":"crossref","first-page":"1411","DOI":"10.1016\/j.gie.2020.10.011","article-title":"Water-assisted colonoscopy: an international modified Delphi review on definitions and practice recommendations","volume":"93","author":"Cadoni","year":"2021","journal-title":"Gastrointest Endosc"},{"key":"R15-20261015","doi-asserted-by":"crossref","first-page":"591","DOI":"10.1016\/j.gie.2018.09.046","article-title":"Comparing adenoma and polyp miss rates for total underwater colonoscopy versus standard CO2: a randomized controlled trial using a tandem colonoscopy approach","volume":"89","author":"Anderson","year":"2019","journal-title":"Gastrointest Endosc"},{"key":"R16-20261015","doi-asserted-by":"crossref","first-page":"477","DOI":"10.1177\/2050640619832196","article-title":"A prospective RCT comparing combined chromoendoscopy with water exchange (CWE) versus water exchange (WE) versus air insufflation (AI) in adenoma detection in screening colonoscopy","volume":"7","author":"Leung","year":"2019","journal-title":"United European Gastroenterol J"},{"key":"R17-20261015","doi-asserted-by":"crossref","first-page":"568","DOI":"10.1038\/ajg.2016.501","article-title":"Water exchange method significantly improves adenoma detection rate: a multicenter, randomized controlled trial","volume":"112","author":"Jia","year":"2017","journal-title":"Am J Gastroenterol"},{"key":"R18-20261015","doi-asserted-by":"crossref","first-page":"869","DOI":"10.1097\/MCG.0000000000001454","article-title":"Comparison of right colon adenoma miss rates between water exchange and carbon dioxide insufflation: a prospective randomized controlled trial","volume":"55","author":"Cheng","year":"2021","journal-title":"J Clin Gastroenterol"},{"key":"R19-20261015","doi-asserted-by":"crossref","first-page":"1615","DOI":"10.14309\/ajg.0000000000003168","article-title":"Comparing right-sided colon adenoma and serrated polyp miss rates with water exchange and CO2 insufflation: a randomized controlled trial","volume":"120","author":"Cheng","year":"2024","journal-title":"Am J Gastroenterol"},{"key":"R20-20261015","doi-asserted-by":"crossref","first-page":"589","DOI":"10.1016\/j.gie.2018.06.028","article-title":"Water exchange colonoscopy increases adenoma detection rate: a systematic review with network meta-analysis of randomized controlled studies","volume":"88","author":"Fuccio","year":"2018","journal-title":"Gastrointest Endosc"},{"key":"R21-20261015","doi-asserted-by":"crossref","first-page":"4841","DOI":"10.1007\/s10620-021-07354-y","article-title":"Comparison of 2\u00a0L polyethylene glycol plus ascorbic acid and 4\u00a0L polyethylene glycol in elderly patients aged 60-79: a prospective randomized study","volume":"67","author":"Jung","year":"2022","journal-title":"Dig Dis Sci"},{"key":"R22-20261015","doi-asserted-by":"crossref","first-page":"1118","DOI":"10.1055\/a-1182-5211","article-title":"Room temperature water infusion during colonoscopy insertion induces rectosigmoid colon mucus production","volume":"52","author":"El Rahyel","year":"2020","journal-title":"Endoscopy"}],"container-title":["Surgical Laparoscopy, Endoscopy &amp; Percutaneous Techniques"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.1097\/SLE.0000000000001516","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,10,15]],"date-time":"2026-10-15T17:00:12Z","timestamp":1792083612000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.1097\/SLE.0000000000001516"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,10,1]]},"references-count":22,"URL":"https:\/\/doi.org\/10.1097\/sle.0000000000001516","relation":{},"ISSN":["1534-4908","1530-4515"],"issn-type":[{"value":"1534-4908","type":"electronic"},{"value":"1530-4515","type":"print"}],"subject":[],"published":{"date-parts":[[2026,10,1]]},"assertion":[{"value":"2026-06-23","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2026-09-11","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}