{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,7]],"date-time":"2026-10-07T01:25:17Z","timestamp":1791336317726,"version":"4.3.1"},"reference-count":27,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"6S","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Trauma Acute Care Surg"],"published-print":{"date-parts":[[2018,6]]},"abstract":"<jats:sec>\n            <jats:title>BACKGROUND<\/jats:title>\n            <jats:p>Intraosseous (IO) vascular access is increasingly used as an emergency tool for achieving access to the systemic circulation in critically ill patients. The role of IO transfusion of blood in damage control resuscitation is however questionable due to possible inadequate flow rate and hemolysis. Some experts claim that IO transfusion is contraindicated. In this study, we have challenged this statement by looking at flow rates of autologous fresh whole blood reinfusion and hemolysis using two of the commonly used Food and Drug Administration\u2013approved and Conformit\u00e9 Europ\u00e9enne (CE)-marked sternal needles. Additionally, the success rate of sternal access between the two devices is evaluated.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>METHODS<\/jats:title>\n            <jats:p>Volunteer professional military personnel, were enrolled prospectively in a nonrandomized observational study design. We collected 450 mL of autologous whole blood from each participant. Participants were divided into the following three groups of 10: Tactically Advanced Lifesaving IO Needle (T.A.L.O.N.) IO, FAST1 IO, and intravenous group. The reinfusion was done by gravity only. Blood sampling was performed before blood collection and 30 minutes after reinfusion. Investigation of hemolysis was performed by measurements of haptoglobin and lactate dehydrogenase. Success rate was evaluated by correct aspiration of bone marrow.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>RESULTS<\/jats:title>\n            <jats:p>Median reinfusion rate was 46.2 mL\/min in the FAST1 group, 32.4 mL\/min in the T.A.L.O.N. group, and 74.1 mL\/min in the intravenous group. Blood samples from all participants were within normal ranges. There was no statistically significant difference in haptoglobin and lactate dehydrogenase between the groups. In the FAST1 group, 1 (9%) of 11 procedures failed. In the T.A.L.O.N. group, 4 (29%) of 14 procedures failed.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>CONCLUSION<\/jats:title>\n            <jats:p>Although preferable, achieving peripheral venous access in the bleeding patient is a major problem. Our findings suggest that fresh whole-blood transfusion through the IO route is safe, reliable, and provide sufficient flow for resuscitation.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>LEVEL OF EVIDENCE<\/jats:title>\n            <jats:p>Therapeutic\/Care management study, level III.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/ta.0000000000001850","type":"journal-article","created":{"date-parts":[[2018,2,16]],"date-time":"2018-02-16T21:40:01Z","timestamp":1518817201000},"page":"S120-S124","source":"Crossref","is-referenced-by-count":26,"title":["Emergency sternal intraosseous access for warm fresh whole blood transfusion in damage control resuscitation"],"prefix":"10.1097","volume":"84","author":[{"given":"Christopher Kalhagen","family":"Bjerkvig","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Theodor Kaurin","family":"Fosse","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Torunn Oveland","family":"Apelseth","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Joar","family":"Sivertsen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hanne","family":"Braathen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"H\u00e5kon Skogrand","family":"Eliassen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Anne Berit","family":"Guttormsen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Andrew P.","family":"Cap","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Geir","family":"Strandenes","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"bib1-20230825","first-page":"1","article-title":"The circulation in the mammalian bone marrow","volume":"62","year":"1922","journal-title":"Am J Physiol"},{"issue":"3","key":"bib2-20230825","doi-asserted-by":"crossref","first-page":"167","DOI":"10.5055\/ajdm.2016.0236","article-title":"A primer on intraosseous access: history, clinical considerations, and current devices","volume":"11","year":"2016","journal-title":"Am J Disaster Med"},{"issue":"2","key":"bib3-20230825","doi-asserted-by":"crossref","first-page":"127","DOI":"10.1017\/S1049023X11000057","article-title":"Evaluation of success rate and access time for an adult sternal intraosseous device deployed in the prehospital setting","volume":"26","year":"2011","journal-title":"Prehosp Disaster Med"},{"key":"bib4-20230825","doi-asserted-by":"crossref","first-page":"43","DOI":"10.1016\/j.resuscitation.2014.12.015","article-title":"EZ-IO(\u00ae) intraosseous device implementation in German Helicopter Emergency Medical Service","volume":"88","year":"2015","journal-title":"Resuscitation"},{"issue":"1","key":"bib5-20230825","first-page":"34","article-title":"Intraosseous access in the military operational setting","volume":"100","year":"2014","journal-title":"J R Nav Med Serv"},{"issue":"6","key":"bib6-20230825","doi-asserted-by":"crossref","first-page":"463","DOI":"10.1136\/emermed-2014-203588","article-title":"Saving the critically injured trauma patient: a retrospective analysis of 1000 uses of intraosseous access","volume":"32","year":"2015","journal-title":"Emerg Med J"},{"issue":"(8 Suppl)","key":"bib7-20230825","first-page":"24","article-title":"A review of the evolution of intraosseous access in tactical settings and a feasibility study of a human cadaver model for a humeral head approach","volume":"179","year":"2014","journal-title":"Mil Med"},{"issue":"6","key":"bib8-20230825","doi-asserted-by":"crossref","first-page":"374","DOI":"10.1503\/cjs.011215","article-title":"Use of intraosseous devices in trauma: a survey of trauma practitioners in Canada, Australia and New Zealand","volume":"59","year":"2016","journal-title":"Can J Surg"},{"issue":"2","key":"bib9-20230825","doi-asserted-by":"crossref","first-page":"166","DOI":"10.55460\/PCUC-U3TV","article-title":"TCCC updates: two decades of saving lives on the battlefield: Tactical Combat Casualty Care Turns 20","volume":"17","year":"2017","journal-title":"J Spec Oper Med"},{"issue":"6","key":"bib10-20230825","doi-asserted-by":"crossref","first-page":"1085","DOI":"10.1097\/00000658-194112000-00015","article-title":"Infusions of blood and other fluids via the bone marrow in traumatic shock and other forms of peripheral circulatory failure","volume":"114","year":"1941","journal-title":"Ann Surg"},{"issue":"Suppl 1","key":"bib11-20230825","first-page":"3","article-title":"Trauma hemostasis and oxygenation research position paper on remote damage control resuscitation: definitions, current practice, and knowledge gaps","volume":"41","year":"2014","journal-title":"Shock"},{"issue":"(6 Suppl)","key":"bib12-20230825","first-page":"S36","article-title":"Damage control resuscitation","volume":"62","year":"2007","journal-title":"J Trauma"},{"issue":"5","key":"bib14-20230825","doi-asserted-by":"crossref","first-page":"904","DOI":"10.1097\/TA.0b013e3182a85f71","article-title":"What is the evidence of utility for intraosseous blood transfusion in damage-control resuscitation?","volume":"75","year":"2013","journal-title":"J Trauma Acute Care Surg"},{"issue":"4","key":"bib15-20230825","doi-asserted-by":"crossref","first-page":"225","DOI":"10.5055\/ajdm.2016.0243","article-title":"En route intraosseous access performed in the combat setting","volume":"11","year":"2016","journal-title":"Am J Disaster Med"},{"issue":"9","key":"bib16-20230825","doi-asserted-by":"crossref","first-page":"799","DOI":"10.1111\/j.1553-2712.1995.tb03275.x","article-title":"Hematologic safety of intraosseous blood transfusion in a swine model of pediatric hemorrhagic hypovolemia","volume":"2","year":"1995","journal-title":"Acad Emerg Med"},{"issue":"11","key":"bib17-20230825","doi-asserted-by":"crossref","first-page":"1487","DOI":"10.1097\/00005373-199111000-00004","article-title":"Intraosseous transfusion in an anesthetized swine model using 51Cr-labeled autologous red blood cells","volume":"31","year":"1991","journal-title":"J Trauma"},{"issue":"3","key":"bib18-20230825","first-page":"198","article-title":"Effects of intraosseous transfusion of whole blood on hemolysis and transfusion time in a swine model of hemorrhagic shock: a pilot study","volume":"82","year":"2014","journal-title":"AANA J"},{"issue":"Suppl 1","key":"bib19-20230825","first-page":"76","article-title":"Emergency whole-blood use in the field: a simplified protocol for collection and transfusion","volume":"41","year":"2014","journal-title":"Shock"},{"issue":"1","key":"bib20-20230825","doi-asserted-by":"crossref","first-page":"24","DOI":"10.1186\/1754-9493-3-24","article-title":"Is the intraosseous access route fast and efficacious compared to conventional central venous catheterization in adult patients under resuscitation in the emergency department? A prospective observational pilot study","volume":"3","year":"2009","journal-title":"Patient Saf Surg"},{"issue":"8","key":"bib21-20230825","doi-asserted-by":"crossref","first-page":"994","DOI":"10.1016\/j.resuscitation.2010.03.038","article-title":"Comparison of two intraosseous access devices in adult patients under resuscitation in the emergency department: a prospective, randomized study","volume":"81","year":"2010","journal-title":"Resuscitation"},{"issue":"6","key":"bib22-20230825","doi-asserted-by":"crossref","first-page":"H1120","DOI":"10.1152\/ajpheart.00851.2016","article-title":"Endothelial dysfunction inhibits the ability of haptoglobin to prevent hemoglobin-induced hypertension","volume":"312","year":"2017","journal-title":"Am J Physiol Heart Circ Physiol"},{"issue":"4","key":"bib23-20230825","doi-asserted-by":"crossref","first-page":"389","DOI":"10.3109\/00365517209080255","article-title":"Elimination of hemoglobin and lactate dehydrogenase from plasma in normals and patients with intravascular hemolysis","volume":"29","year":"1972","journal-title":"Scand J Clin Lab Invest"},{"issue":"2","key":"bib24-20230825","doi-asserted-by":"crossref","first-page":"389","DOI":"10.1111\/j.1538-7836.2009.03704.x","article-title":"Rapid clearance of circulating haptoglobin from plasma during acute pulmonary embolism in rats results in HMOX1 up-regulation in peripheral blood leukocytes","volume":"8","year":"2010","journal-title":"J Thromb Haemost"},{"issue":"2","key":"bib25-20230825","doi-asserted-by":"crossref","first-page":"224","DOI":"10.1097\/TA.0000000000000502","article-title":"The new metric to define large-volume hemorrhage: results of a prospective study of the critical administration threshold","volume":"78","year":"2015","journal-title":"J Trauma Acute Care Surg"},{"issue":"12","key":"bib26-20230825","doi-asserted-by":"crossref","first-page":"1443","DOI":"10.1111\/anae.14034","article-title":"Permissive hypotension for active haemorrhage in trauma","volume":"72","year":"2017","journal-title":"Anaesthesia"},{"issue":"2","key":"bib27-20230825","first-page":"173","article-title":"A new system for sternal intraosseous infusion in adults","volume":"4","year":"2000","journal-title":"Prehosp Emerg Care"},{"issue":"3","key":"bib28-20230825","doi-asserted-by":"crossref","first-page":"221","DOI":"10.1136\/jramc-2016-000699","article-title":"Long-term follow-up of two patients with retained intraosseous sternal needles","volume":"163","year":"2017","journal-title":"J R Army Med Corps"}],"container-title":["Journal of Trauma and Acute Care Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/01586154-201806001-00019","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,8,25]],"date-time":"2023-08-25T09:55:46Z","timestamp":1692957346000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/01586154-201806001-00019"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,6]]},"references-count":27,"journal-issue":{"issue":"6S","published-print":{"date-parts":[[2018]]}},"URL":"https:\/\/doi.org\/10.1097\/ta.0000000000001850","relation":{},"ISSN":["2163-0763","2163-0755"],"issn-type":[{"value":"2163-0763","type":"electronic"},{"value":"2163-0755","type":"print"}],"subject":[],"published":{"date-parts":[[2018,6]]}}}