{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,6]],"date-time":"2026-11-06T18:59:36Z","timestamp":1793991576288,"version":"4.8.0"},"reference-count":32,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"6","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Trauma Acute Care Surg"],"published-print":{"date-parts":[[2020,12]]},"abstract":"<jats:sec>\n            <jats:title>BACKGROUND<\/jats:title>\n            <jats:p>Open, emergency abdominal surgery is associated with a high incidence of fascial dehiscence and incisional hernia. Implantation of biologic meshes potentially reinforces the abdominal wall and therefore decreases such complications. The aim of this prospective randomized study was to compare the outcome after prophylactic intraperitoneal implantation of a biologic Strattice mesh (Allergan, Dublin, Ireland) with standard abdominal closure in patients undergoing emergency abdominal surgery.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>METHODS<\/jats:title>\n            <jats:p>A two-arm randomized clinical trial was performed in patients undergoing emergency abdominal surgery at Bern University Hospital, University of Bern, Switzerland, from April 2016 to March 2019. Patients were randomly assigned to prophylactic implantation of a biological intraperitoneal mesh using Strattice, Allergan (mesh group), or standard abdominal closure using a single, continuous running suture (no-mesh group). Because of safety concerns, patient enrollment was closed prematurely.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>RESULTS<\/jats:title>\n            <jats:p>Eligibility for inclusion was assessed in 61 patients. A total of 48 patients were randomized (21 in the mesh group, 28 in the no-mesh group). No differences in baseline characteristics were found. Abdominal wall complications requiring reoperations were more frequent in the mesh group compared to the no-mesh group (5 [83.3%] of 13 vs. 1 [14.3%] of 13 patients, <jats:italic toggle=\"yes\">p<\/jats:italic> = 0.026). Mesh-associated abdominal wall complications included nonintegration of the mesh into the abdominal wall, dissolution of the mesh, and mesh-related infections.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>CONCLUSION<\/jats:title>\n            <jats:p>In patients undergoing emergency abdominal surgery, intraperitoneal biologic Strattice mesh implantation is associated with significantly more frequent abdominal wall complications requiring reoperation. Therefore, the use of such meshes cannot be recommended in the contaminated environment of emergency abdominal surgery.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>LEVEL OF EVIDENCE<\/jats:title>\n            <jats:p>Therapeutic, level I.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/ta.0000000000002877","type":"journal-article","created":{"date-parts":[[2020,7,10]],"date-time":"2020-07-10T07:28:04Z","timestamp":1594366084000},"page":"1149-1155","source":"Crossref","is-referenced-by-count":20,"title":["Biologic mesh implantation is associated with serious abdominal wall complications in patients undergoing emergency abdominal surgery: A randomized-controlled clinical trial"],"prefix":"10.1097","volume":"89","author":[{"given":"Manuel O.","family":"Jakob","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tobias","family":"Haltmeier","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Daniel","family":"Candinas","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Guido","family":"Beldi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2020,7,10]]},"reference":[{"issue":"9","key":"bib1-20230825","doi-asserted-by":"crossref","first-page":"e0138745","DOI":"10.1371\/journal.pone.0138745","article-title":"Systematic review and meta-regression of factors affecting midline incisional hernia rates: analysis of 14,618 patients","volume":"10","year":"2015","journal-title":"PLoS One"},{"issue":"2","key":"bib2-20230825","first-page":"51","article-title":"Incisional hernia rate 3 years after midline laparotomy","volume":"101","year":"2014","journal-title":"Br J Surg"},{"issue":"1","key":"bib3-20230825","doi-asserted-by":"crossref","first-page":"19","DOI":"10.1016\/j.clindermatol.2006.12.005","article-title":"Impaired wound healing","volume":"25","year":"2007","journal-title":"Clin Dermatol"},{"issue":"8","key":"bib4-20230825","doi-asserted-by":"crossref","first-page":"470","DOI":"10.1016\/j.ajic.2004.10.001","article-title":"National Nosocomial Infections Surveillance (NNIS) system report, data summary from January 1992 through June 2004, issued October 2004","volume":"32","year":"2004","journal-title":"Am J Infect Control"},{"issue":"5","key":"bib5-20230825","doi-asserted-by":"crossref","first-page":"1238","DOI":"10.1016\/j.surg.2014.04.035","article-title":"Prophylactic synthetic mesh can be safely used to close emergency laparotomies, even in peritonitis","volume":"156","year":"2014","journal-title":"Surgery"},{"issue":"5","key":"bib6-20230825","doi-asserted-by":"crossref","first-page":"534","DOI":"10.1046\/j.1365-2168.2002.02083.x","article-title":"Surgical treatment of incisional hernia","volume":"89","year":"2002","journal-title":"Br J Surg"},{"issue":"1","key":"bib7-20230825","doi-asserted-by":"crossref","first-page":"129","DOI":"10.1097\/00000658-200301000-00018","article-title":"Have outcomes of incisional hernia repair improved with time? A population-based analysis","volume":"237","year":"2003","journal-title":"Ann Surg"},{"issue":"2","key":"bib8-20230825","doi-asserted-by":"crossref","first-page":"130","DOI":"10.1016\/S0022-4804(02)00097-5","article-title":"Prognostic models of abdominal wound dehiscence after laparotomy","volume":"109","year":"2003","journal-title":"J Surg Res"},{"issue":"1","key":"bib9-20230825","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1007\/s10029-014-1342-5","article-title":"European Hernia Society guidelines on the closure of abdominal wall incisions","volume":"19","year":"2015","journal-title":"Hernia"},{"issue":"2","key":"bib10-20230825","doi-asserted-by":"crossref","first-page":"109","DOI":"10.1001\/jamasurg.2018.4221","article-title":"Effectiveness of prophylactic intraperitoneal mesh implantation for prevention of incisional hernia in patients undergoing open abdominal surgery: a randomized clinical trial","volume":"154","year":"2019","journal-title":"JAMA Surg"},{"issue":"10094","key":"bib11-20230825","doi-asserted-by":"crossref","first-page":"567","DOI":"10.1016\/S0140-6736(17)31332-6","article-title":"Prevention of incisional hernia with prophylactic onlay and sublay mesh reinforcement versus primary suture only in midline laparotomies (PRIMA): 2-year follow-up of a multicentre, double-blind, randomised controlled trial","volume":"390","year":"2017","journal-title":"Lancet"},{"issue":"5","key":"bib12-20230825","doi-asserted-by":"crossref","first-page":"785","DOI":"10.1007\/s10029-018-1798-9","article-title":"Mesh-augmented versus direct abdominal closure in patients undergoing open abdomen treatment","volume":"22","year":"2018","journal-title":"Hernia"},{"issue":"12","key":"bib13-20230825","doi-asserted-by":"crossref","first-page":"2158","DOI":"10.1007\/s11605-018-3873-z","article-title":"Prophylactic, synthetic intraperitoneal mesh versus no mesh implantation in patients with fascial dehiscence","volume":"22","year":"2018","journal-title":"J Gastrointest Surg"},{"issue":"5","key":"bib14-20230825","doi-asserted-by":"crossref","first-page":"415","DOI":"10.1001\/jamasurg.2013.5014","article-title":"Comparison of outcomes of synthetic mesh vs suture repair of elective primary ventral herniorrhaphy: a systematic review and meta-analysis","volume":"149","year":"2014","journal-title":"JAMA Surg"},{"issue":"2","key":"bib15-20230825","doi-asserted-by":"crossref","first-page":"185","DOI":"10.2217\/17460751.4.2.185","article-title":"Retention of structural and biochemical integrity in a biological mesh supports tissue remodeling in a primate abdominal wall model","volume":"4","year":"2009","journal-title":"Regen Med"},{"issue":"2","key":"bib16-20230825","doi-asserted-by":"crossref","first-page":"488","DOI":"10.1016\/j.jss.2015.09.007","article-title":"Suture, synthetic, or biologic in contaminated ventral hernia repair","volume":"200","year":"2016","journal-title":"J Surg Res"},{"issue":"2","key":"bib17-20230825","doi-asserted-by":"crossref","first-page":"229","DOI":"10.1016\/j.amjsurg.2009.08.043","article-title":"Long term follow up for incisional hernia after severe secondary peritonitis-incidence and risk factors","volume":"200","year":"2010","journal-title":"Am J Surg"},{"issue":"1","key":"bib18-20230825","doi-asserted-by":"crossref","first-page":"122","DOI":"10.1097\/TA.0000000000001015","article-title":"Perioperative risk factors impact outcomes in emergency versus nonemergency surgery differently: time to separate our national risk-adjustment models?","volume":"81","year":"2016","journal-title":"J Trauma Acute Care Surg"},{"issue":"5","key":"bib19-20230825","doi-asserted-by":"crossref","first-page":"912","DOI":"10.1097\/TA.0000000000000611","article-title":"Impact of specific postoperative complications on the outcomes of emergency general surgery patients","volume":"78","year":"2015","journal-title":"J Trauma Acute Care Surg"},{"issue":"7","key":"bib20-20230825","doi-asserted-by":"crossref","first-page":"1557","DOI":"10.1007\/s00268-012-1534-z","article-title":"Intraperitoneal mesh implantation for fascial dehiscence and open abdomen","volume":"36","year":"2012","journal-title":"World J Surg"},{"issue":"3","key":"bib21-20230825","doi-asserted-by":"crossref","first-page":"498","DOI":"10.1016\/j.surg.2012.04.008","article-title":"Prospective study of single-stage repair of contaminated hernias using a biologic porcine tissue matrix: the RICH Study","volume":"152","year":"2012","journal-title":"Surgery"},{"issue":"6","key":"bib22-20230825","doi-asserted-by":"crossref","first-page":"1517","DOI":"10.1016\/j.surg.2016.07.008","article-title":"Biologic mesh in ventral hernia repair: outcomes, recurrence, and charge analysis","volume":"160","year":"2016","journal-title":"Surgery"},{"issue":"5","key":"bib23-20230825","doi-asserted-by":"crossref","first-page":"658","DOI":"10.1016\/j.jamcollsurg.2010.01.014","article-title":"Direct peritoneal resuscitation accelerates primary abdominal wall closure after damage control surgery","volume":"210","year":"2010","journal-title":"J Am Coll Surg"},{"issue":"1","key":"bib24-20230825","doi-asserted-by":"crossref","first-page":"205","DOI":"10.1097\/SLA.0000000000001601","article-title":"Multicenter, prospective, longitudinal study of the recurrence, surgical site infection, and quality of life after contaminated ventral hernia repair using biosynthetic absorbable mesh: the COBRA study","volume":"265","year":"2017","journal-title":"Ann Surg"},{"issue":"6","key":"bib25-20230825","doi-asserted-by":"crossref","first-page":"e0197883","DOI":"10.1371\/journal.pone.0197883","article-title":"The regulatory ancestral network of surgical meshes","volume":"13","year":"2018","journal-title":"PLoS One"},{"issue":"5","key":"bib26-20230825","doi-asserted-by":"crossref","first-page":"982","DOI":"10.1016\/j.amjsurg.2016.05.003","article-title":"Systematic review and meta-analysis of the repair of potentially contaminated and contaminated abdominal wall defects","volume":"212","year":"2016","journal-title":"Am J Surg"},{"issue":"2","key":"bib27-20230825","doi-asserted-by":"crossref","first-page":"249","DOI":"10.1007\/s10029-018-1735-y","article-title":"What is the evidence for the use of biologic or biosynthetic meshes in abdominal wall reconstruction?","volume":"22","year":"2018","journal-title":"Hernia"},{"key":"bib28-20230825","first-page":"2041731413505305","article-title":"Process-induced extracellular matrix alterations affect the mechanisms of soft tissue repair and regeneration","volume":"4","year":"2013","journal-title":"J Tissue Eng"},{"issue":"15","key":"bib29-20230825","doi-asserted-by":"crossref","first-page":"4026","DOI":"10.1016\/j.jbiomech.2015.09.045","article-title":"Dynamic intermittent strain can rapidly impair ventral hernia repair","volume":"48","year":"2015","journal-title":"J Biomech"},{"issue":"30","key":"bib30-20230825","doi-asserted-by":"crossref","first-page":"12197","DOI":"10.1073\/pnas.1222787110","article-title":"Strain history dependence of the nonlinear stress response of fibrin and collagen networks","volume":"110","year":"2013","journal-title":"Proc Natl Acad Sci U S A"},{"issue":"1","key":"bib31-20230825","doi-asserted-by":"crossref","first-page":"85","DOI":"10.1016\/j.amjsurg.2012.02.019","article-title":"Repair of incisional hernias with biological prosthesis: a systematic review of current evidence","volume":"205","year":"2013","journal-title":"Am J Surg"},{"key":"bib32-20230825","doi-asserted-by":"crossref","first-page":"66","DOI":"10.3389\/fsurg.2018.00066","article-title":"Open Intraperitoneal Onlay Mesh (IPOM) technique for incisional hernia repair","volume":"5","year":"2018","journal-title":"Front Surg"}],"container-title":["Journal of Trauma and Acute Care Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/TA.0000000000002877","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,8,25]],"date-time":"2023-08-25T10:19:26Z","timestamp":1692958766000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/TA.0000000000002877"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,7,10]]},"references-count":32,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2020]]}},"URL":"https:\/\/doi.org\/10.1097\/ta.0000000000002877","relation":{},"ISSN":["2163-0763","2163-0755"],"issn-type":[{"value":"2163-0763","type":"electronic"},{"value":"2163-0755","type":"print"}],"subject":[],"published":{"date-parts":[[2020,7,10]]}}}