{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,11]],"date-time":"2026-09-11T01:23:24Z","timestamp":1789089804773,"version":"build-2803163510"},"reference-count":27,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"5","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":["J Trauma Acute Care Surg"],"published-print":{"date-parts":[[2021,11]]},"abstract":"<jats:sec>\n            <jats:title>BACKGROUND<\/jats:title>\n            <jats:p>The use of resuscitative endovascular balloon occlusion of the aorta (REBOA) is controversial. We hypothesize that REBOA outcomes are improved in centers with high REBOA utilization.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>METHODS<\/jats:title>\n            <jats:p>We examined the Aortic Occlusion in Resuscitation for Trauma and Acute Care Surgery registry over a 5-year period (2014\u20132018). Resuscitative endovascular balloon occlusion of the aorta outcomes were analyzed by stratifying institutions into low-volume (&lt;10), average-volume (11\u201330), and high-volume (&gt;30) deployment centers. A multivariable model adjusting for volume group, mechanism of injury, signs of life, systolic blood pressure at initiation, operator level, device type, zone of placement, and hemodynamic response to aortic occlusion was created to analyze REBOA mortality and REBOA-related complications.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>RESULTS<\/jats:title>\n            <jats:p>Four hundred ninety-five REBOA placements were included. High-volume centers accounted for 63%, while low accounted for 13%. High-volume institutions were more likely to place a REBOA in the emergency department (81% vs. 63% low volume, <jats:italic toggle=\"yes\">p<\/jats:italic> = 0.003), had a lower mean systolic blood pressure at insertion (53 \u00b1 38 vs. 64 \u00b1 40, <jats:italic toggle=\"yes\">p<\/jats:italic> = 0.001), and more Zone I deployments (64% vs. 55%, <jats:italic toggle=\"yes\">p<\/jats:italic> = 0.002). Median time from admission to REBOA placement was significantly less in patients treated at high-volume centers (15 [7\u201330] minutes vs. 35 [20\u201365] minutes, <jats:italic toggle=\"yes\">p<\/jats:italic> = 0.001). Resuscitative endovascular balloon occlusion of the aorta mortality was significantly higher at low-volume centers (67% vs. 57%; adjusted odds ratio, 1.29; adj <jats:italic toggle=\"yes\">p<\/jats:italic> = 0.040), while average- and high-volume centers were similar. Resuscitative endovascular balloon occlusion of the aorta complications were less frequent at high-\/average-volume centers, but did not reach statistical significance (adj <jats:italic toggle=\"yes\">p<\/jats:italic> = 0.784).<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>CONCLUSION<\/jats:title>\n            <jats:p>Resuscitative endovascular balloon occlusion of the aorta survival is increased at high versus low utilization centers. Increased experience with REBOA may be associated with earlier deployment and subsequently improved patient outcomes.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>LEVEL OF EVIDENCE<\/jats:title>\n            <jats:p>Therapeutic\/Care Management, level IV.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/ta.0000000000003201","type":"journal-article","created":{"date-parts":[[2021,4,2]],"date-time":"2021-04-02T08:16:09Z","timestamp":1617351369000},"page":"781-789","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":21,"title":["High resuscitative endovascular balloon occlusion of the aorta procedural volume is associated with improved outcomes: An analysis of the AORTA registry"],"prefix":"10.1097","volume":"91","author":[{"given":"Elizabeth","family":"Gorman","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Brittany","family":"Nowak","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michael","family":"Klein","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kenji","family":"Inaba","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jonathan","family":"Morrison","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Thomas","family":"Scalea","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mark","family":"Seamon","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Charles","family":"Fox","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Laura","family":"Moore","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"David","family":"Kauvar","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Marshall","family":"Spalding","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Joseph","family":"Dubose","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Charles","family":"DiMaggio","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"David H.","family":"Livingston","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Marko","family":"Bukur","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"name":"the AAST AORTA Study Group","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2021,3,31]]},"reference":[{"key":"bib1-20250806","doi-asserted-by":"crossref","first-page":"275","DOI":"10.1016\/j.resuscitation.2015.09.003","article-title":"Resuscitative endovascular balloon occlusion of the aorta","volume":"96","year":"2015","journal-title":"Resuscitation"},{"issue":"1","key":"bib2-20250806","doi-asserted-by":"crossref","first-page":"414","DOI":"10.1016\/j.jss.2013.05.099","article-title":"Epidemiology and outcomes of non-compressible torso hemorrhage","volume":"184","year":"2013","journal-title":"J Surg Res"},{"issue":"2 Suppl 2","key":"bib3-20250806","first-page":"S263","article-title":"Injury pattern and mortality of noncompressible torso hemorrhage in UK combat casualties","volume":"75","year":"2013","journal-title":"J Trauma Acute Care Surg"},{"issue":"1","key":"bib4-20250806","first-page":"65","article-title":"Use of an intra-aortic balloon catheter tamponade for controlling intra-abdominal hemorrhage in man","volume":"36","year":"1954","journal-title":"Dermatol Surg"},{"issue":"1","key":"bib5-20250806","first-page":"21","article-title":"Hate to burst your balloon: successful REBOA use takes more than a course","volume":"4","year":"2020","journal-title":"J Endovasc Resusc Trauma Manag"},{"key":"bib6-20250806","article-title":"Temporal changes in reboa utilization practices are associated with increased survival: an analysis of the Aorta Registry","year":"2020","journal-title":"Shock"},{"key":"bib7-20250806","doi-asserted-by":"crossref","first-page":"20","DOI":"10.1186\/s13017-018-0181-6","article-title":"The complications associated with resuscitative endovascular balloon occlusion of the aorta (REBOA)","volume":"13","year":"2018","journal-title":"World J Emerg Surg"},{"issue":"1","key":"bib8-20250806","doi-asserted-by":"crossref","first-page":"192","DOI":"10.1097\/TA.0000000000001711","article-title":"The pitfalls of resuscitative endovascular balloon occlusion of the aorta: Risk factors and mitigation strategies","volume":"84","year":"2018","journal-title":"J Trauma Acute Care Surg"},{"issue":"3","key":"bib9-20250806","doi-asserted-by":"crossref","first-page":"409","DOI":"10.1097\/TA.0000000000001079","article-title":"The AAST prospective Aortic Occlusion for Resuscitation in Trauma and Acute Care Surgery (AORTA) registry: data on contemporary utilization and outcomes of aortic occlusion and resuscitative balloon occlusion of the aorta (REBOA)","volume":"81","year":"2016","journal-title":"J Trauma Acute Care Surg"},{"issue":"2","key":"bib10-20250806","doi-asserted-by":"crossref","first-page":"147","DOI":"10.1016\/j.injury.2019.11.036","article-title":"Training and assessment of competence in resuscitative endovascular balloon occlusion of the aorta (REBOA)\u2014a systematic review","volume":"51","year":"2020","journal-title":"Injury"},{"issue":"2","key":"bib11-20250806","doi-asserted-by":"crossref","first-page":"286","DOI":"10.1097\/TA.0000000000000310","article-title":"Basic endovascular skills for trauma course: bridging the gap between endovascular techniques and the acute care surgeon","volume":"77","year":"2014","journal-title":"J Trauma Acute Care Surg"},{"issue":"9","key":"bib12-20250806","doi-asserted-by":"crossref","first-page":"1164","DOI":"10.1001\/jama.285.9.1164","article-title":"Relationship between trauma center volume and outcomes","volume":"285","year":"2001","journal-title":"JAMA"},{"issue":"4","key":"bib13-20250806","doi-asserted-by":"crossref","first-page":"810","DOI":"10.1097\/TA.0000000000002043","article-title":"The volume-outcome relationship in severely injured patients: a systematic review and meta-analysis","volume":"85","year":"2018","journal-title":"J Trauma Acute Care Surg"},{"key":"bib14-20250806","first-page":"1","article-title":"Hospital volume-outcome relationship in severe traumatic brain injury: stratified analysis by level of trauma center","year":"2020","journal-title":"J Neurosurg"},{"issue":"5","key":"bib15-20250806","doi-asserted-by":"crossref","first-page":"730","DOI":"10.1016\/j.jamcollsurg.2018.01.044","article-title":"Resuscitative endovascular balloon occlusion of the aorta and resuscitative thoracotomy in select patients with hemorrhagic shock: early results from the American Association for the Surgery of Trauma\u2019s Aortic Occlusion in Resuscitation for Trauma and Acute Care Surgery Registry","volume":"226","year":"2018","journal-title":"J Am Coll Surg"},{"issue":"4","key":"bib16-20250806","doi-asserted-by":"crossref","first-page":"512","DOI":"10.1097\/01.sla.0000184169.73614.09","article-title":"The effect of trauma center designation and trauma volume on outcome in specific severe injuries","volume":"242","year":"2005","journal-title":"Ann Surg"},{"issue":"1","key":"bib17-20250806","doi-asserted-by":"crossref","first-page":"173","DOI":"10.1097\/SLA.0000000000001838","article-title":"Impact of volume change over time on trauma mortality in the United States","volume":"266","year":"2017","journal-title":"Ann Surg"},{"issue":"4","key":"bib18-20250806","doi-asserted-by":"crossref","first-page":"685","DOI":"10.1097\/TA.0000000000001198","article-title":"Effect of time to operation on mortality for hypotensive patients with gunshot wounds to the torso: the golden 10 minutes","volume":"81","year":"2016","journal-title":"J Trauma Acute Care Surg"},{"issue":"3","key":"bib19-20250806","first-page":"420","article-title":"Time to laparotomy for intra-abdominal bleeding from trauma does affect survival for delays up to 90 minutes","volume":"52","year":"2002","journal-title":"J Trauma"},{"issue":"1","key":"bib20-20250806","doi-asserted-by":"crossref","first-page":"e000154","DOI":"10.1136\/tsaco-2017-000154","article-title":"Joint statement from the American College of Surgeons Committee on Trauma (ACS COT) and the American College of Emergency Physicians (ACEP) regarding the clinical use of Resuscitative Endovascular Balloon Occlusion of the Aorta (REBOA)","volume":"3","year":"2018","journal-title":"Trauma Surg Acute Care Open"},{"issue":"1","key":"bib21-20250806","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1590\/1677-5449.030317","article-title":"REBOA: is it ready for prime time?","volume":"16","year":"2017","journal-title":"J Vasc Bras"},{"key":"bib22-20250806","doi-asserted-by":"crossref","first-page":"721","DOI":"10.1097\/TA.0000000000000578","article-title":"Survival of severe blunt trauma patients treated with resuscitative endovascular balloon occlusion of the aorta compared with propensity score-adjusted untreated patients","volume":"78","year":"2015","journal-title":"J Trauma Acute Care Surg"},{"issue":"6","key":"bib23-20250806","doi-asserted-by":"crossref","first-page":"1161","DOI":"10.1097\/TA.0000000000001665","article-title":"Time to aortic occlusion: it\u2019s all about access","volume":"83","year":"2017","journal-title":"J Trauma Acute Care Surg"},{"issue":"4","key":"bib24-20250806","doi-asserted-by":"crossref","first-page":"559","DOI":"10.1097\/TA.0000000000000968","article-title":"Resuscitative endovascular balloon occlusion of the aorta might be dangerous in patients with severe torso trauma: a propensity score analysis","volume":"80","year":"2016","journal-title":"J Trauma Acute Care Surg"},{"key":"bib26-20250806","doi-asserted-by":"crossref","first-page":"18","DOI":"10.1016\/j.jss.2020.03.027","article-title":"Practice, practice, practice! Effect of resuscitative endovascular balloon occlusion of the aorta volume on outcomes: data from the AAST AORTA Registry","volume":"253","year":"2020","journal-title":"J Surg Res"},{"issue":"12","key":"bib27-20250806","doi-asserted-by":"crossref","first-page":"793","DOI":"10.1136\/emermed-2016-206383","article-title":"Fewer REBOA complications with smaller devices and partial occlusion: evidence from a multicentre registry in Japan","volume":"34","year":"2017","journal-title":"Emerg Med J"},{"key":"bib28-20250806","article-title":"The Colombian experience in resuscitative endovascular balloon occlusion of the aorta (REBOA): the progression from a large caliber to a low-profile device at a level I trauma center","year":"2020","journal-title":"Shock"}],"container-title":["Journal of Trauma and Acute Care Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/TA.0000000000003201","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,8,6]],"date-time":"2025-08-06T16:12:53Z","timestamp":1754496773000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/TA.0000000000003201"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,3,31]]},"references-count":27,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2021]]}},"URL":"https:\/\/doi.org\/10.1097\/ta.0000000000003201","relation":{},"ISSN":["2163-0763","2163-0755"],"issn-type":[{"value":"2163-0763","type":"electronic"},{"value":"2163-0755","type":"print"}],"subject":[],"published":{"date-parts":[[2021,3,31]]}}}