{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,18]],"date-time":"2026-11-18T00:50:46Z","timestamp":1794963046177,"version":"4.9.1"},"reference-count":37,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"5","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":["J Trauma Acute Care Surg"],"published-print":{"date-parts":[[2022,5]]},"abstract":"<jats:sec>\n            <jats:title>BACKGROUND<\/jats:title>\n            <jats:p>Assessment of the volemic loss is a major challenge during the management of hemorrhagic shock. Echocardiography is an increasingly used noninvasive tool for hemodynamic assessment. In mechanically ventilated patients, some studies suggest that respiratory variations of mean subaortic time-velocity integral (\u2206VTI) would be predictive of fluid filling response. An experimental model of controlled hemorrhagic shock provides a precise approach to study correlation between blood volume and cardiac ultrasonographic parameters.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>OBJECTIVES<\/jats:title>\n            <jats:p>The main objective was to analyze the \u2206VTI changes during hemorrhage in an anesthetized-piglet model of controlled hemorrhagic shock. The secondary objective was to evaluate \u2206VTI during the resuscitation process after hemorrhage and other echocardiographic parameters changes during the whole protocol.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>METHODS<\/jats:title>\n            <jats:p>Twenty-four anesthetized and ventilated piglets were bled until mean arterial pressure reached 40 mm Hg. Controlled hemorrhage was maintained for 30 minutes before randomizing the piglets to two resuscitation groups: fluid filling group resuscitated with saline solution and noradrenaline group resuscitated with saline solution and noradrenaline. Echocardiography and hemodynamic measures, including pulsed pressure variations (PPV), were performed at different stages of the protocol.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>RESULTS<\/jats:title>\n            <jats:p>The correlation coefficient between \u0394VTI and PPV with the volume of bleeding during the hemorrhagic phase were respectively 0.24 (95% confidence interval, 0.08\u20130.39; <jats:italic toggle=\"yes\">p<\/jats:italic> &lt; 0.01) and 0.57 (95% CI, 0.44\u20130.67; <jats:italic toggle=\"yes\">p<\/jats:italic> &lt; 0.01). Two parameters had a moderate correlation coefficient with hemorrhage volume (over 0.5): mean subaortic time-velocity index (VTI) and mitral annulus diastolic tissular velocity (E\u2032).<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>CONCLUSION<\/jats:title>\n            <jats:p>In this hemorrhagic shock model, \u0394VTI had a low correlation with the volume of bleeding, but VTI and E\u2032 had a correlation with blood volume comparable to that of PPV.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/ta.0000000000003518","type":"journal-article","created":{"date-parts":[[2022,1,6]],"date-time":"2022-01-06T18:04:20Z","timestamp":1641492260000},"page":"924-930","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":9,"title":["Can blood loss be assessed by echocardiography? An experimental study on a controlled hemorrhagic shock model in piglets"],"prefix":"10.1097","volume":"92","author":[{"given":"Laura","family":"Grau-Mercier","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Fabien","family":"Coisy","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Thibaut","family":"Markarian","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Laurent","family":"Muller","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Claire","family":"Roger","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jean-Yves","family":"Lefrant","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Pierre-G\u00e9raud","family":"Claret","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xavier","family":"Bobbia","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2022,1,4]]},"reference":[{"issue":"7","key":"bib1-20250806","doi-asserted-by":"crossref","first-page":"1507","DOI":"10.1007\/s00268-007-9087-2","article-title":"Epidemiology of urban trauma deaths: a comprehensive reassessment 10 years later","volume":"31","year":"2007","journal-title":"World J Surg"},{"issue":"1","key":"bib2-20250806","doi-asserted-by":"crossref","first-page":"98","DOI":"10.1186\/s13054-019-2347-3","article-title":"The European guideline on management of major bleeding and coagulopathy following trauma: fifth edition","volume":"23","year":"2019","journal-title":"Crit Care"},{"issue":"2","key":"bib3-20250806","doi-asserted-by":"crossref","first-page":"212","DOI":"10.1093\/bja\/aem165","article-title":"Crystalloid infusion rate during fluid resuscitation from acute haemorrhage","volume":"99","year":"2007","journal-title":"Br J Anaesth"},{"issue":"4","key":"bib4-20250806","doi-asserted-by":"crossref","first-page":"496","DOI":"10.1097\/00000658-197104000-00003","article-title":"Blood volume. II. Precise long-term measurements using chromium-tagged erythrocytes","volume":"173","year":"1971","journal-title":"Ann Surg"},{"issue":"8","key":"bib5-20250806","doi-asserted-by":"crossref","first-page":"1446","DOI":"10.1097\/00003246-199808000-00036","article-title":"Measurement of blood volume using indocyanine green measured with pulse-spectrophotometry: its reproducibility and reliability","volume":"26","year":"1998","journal-title":"Crit Care Med"},{"key":"bib6-20250806","article-title":"\u00c9valuation et monitorage h\u00e9modynamique","year":"2014","journal-title":"Urgences"},{"key":"bib7-20250806","doi-asserted-by":"crossref","first-page":"147","DOI":"10.1007\/s001340050536","article-title":"Volume replacement strategies on intensive care units: results from a postal survey","volume":"24","year":"1998","journal-title":"Intensive Care Med"},{"issue":"6","key":"bib8-20250806","doi-asserted-by":"crossref","first-page":"587","DOI":"10.1186\/s13054-014-0587-9","article-title":"Clinical relevance of pulse pressure variations for predicting fluid responsiveness in mechanically ventilated intensive care unit patients: the grey zone approach","volume":"18","year":"2014","journal-title":"Crit Care"},{"issue":"12","key":"bib9-20250806","doi-asserted-by":"crossref","first-page":"1795","DOI":"10.1007\/s00134-014-3525-z","article-title":"Consensus on circulatory shock and hemodynamic monitoring. Task force of the European Society of Intensive Care Medicine","volume":"40","year":"2014","journal-title":"Intensive Care Med"},{"key":"bib10-20250806","doi-asserted-by":"crossref","first-page":"R188","DOI":"10.1186\/cc11672","article-title":"Respiratory variations of inferior vena cava diameter to predict fluid responsiveness in spontaneously breathing patients with acute circulatory failure: need for a cautious use","volume":"16","year":"2012","journal-title":"Crit Care"},{"issue":"8","key":"bib11-20250806","doi-asserted-by":"crossref","first-page":"946","DOI":"10.1111\/j.1540-8175.2010.01177.x","article-title":"New, simple echocardiographic indexes for the estimation of filling pressure in patients with cardiac disease and preserved left ventricular ejection fraction","volume":"27","year":"2010","journal-title":"Echocardiography"},{"issue":"12","key":"bib12-20250806","doi-asserted-by":"crossref","first-page":"1935","DOI":"10.1007\/s00134-015-4134-1","article-title":"Passive leg raising for predicting fluid responsiveness: a systematic review and meta-analysis","volume":"42","year":"2016","journal-title":"Intensive Care Med"},{"issue":"3","key":"bib13-20250806","first-page":"290","article-title":"What is a fluid challenge?","volume":"17","year":"2011","journal-title":"Curr Opin Crit Care"},{"key":"bib14-20250806","first-page":"H500","article-title":"Total arterial compliance estimated by stroke volume-to-aortic pulse pressure ratio in humans","volume":"274","year":"1998","journal-title":"Am J Phys"},{"key":"bib15-20250806","article-title":"Relation between respiratory changes in arterial pulse pressure and fluid responsiveness in septic patients with acute circulatory failure [internet]","volume":"162","year":"2000","journal-title":"Am J Respir Crit Care Med"},{"key":"bib16-20250806","doi-asserted-by":"crossref","first-page":"H1729","DOI":"10.1152\/ajpheart.00308.2002","article-title":"Respiratory variations of aortic VTI: a new index of hypovolemia and fluid responsiveness","volume":"283","year":"2002","journal-title":"Am J Physiol Heart Circ Physiol"},{"key":"bib17-20250806","first-page":"867","article-title":"Respiratory changes in aortic blood velocity as an indicator of fluid responsiveness in ventilated patients with septic shock","volume":"274","year":"2001","journal-title":"Chest"},{"key":"bib18-20250806","doi-asserted-by":"crossref","first-page":"1511","DOI":"10.1213\/01.ane.0000209015.21418.f4","article-title":"The influence of tidal volume on the dynamic variables of fluid responsiveness in critically ill patients","volume":"102","year":"2006","journal-title":"Anesth Analg"},{"issue":"3","key":"bib19-20250806","doi-asserted-by":"crossref","first-page":"97","DOI":"10.4103\/2452-2473.290066","article-title":"Global longitudinal strain changes during hemorrhagic shock: an experimental study","volume":"20","year":"2020","journal-title":"Turk J Emerg Med"},{"issue":"6","key":"bib20-20250806","doi-asserted-by":"crossref","first-page":"1015","DOI":"10.1093\/bja\/aet375","article-title":"Does the type of fluid affect rapidity of shock reversal in an anaesthetized-piglet model of near-fatal controlled haemorrhage? A randomized study","volume":"112","year":"2014","journal-title":"Br J Anaesth"},{"issue":"1","key":"bib21-20250806","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.echo.2018.06.004","article-title":"Guidelines for performing a comprehensive transthoracic echocardiographic examination in adults: recommendations from the American Society of Echocardiography","volume":"32","year":"2019","journal-title":"J Am Soc Echocardiogr"},{"issue":"8","key":"bib22-20250806","doi-asserted-by":"crossref","first-page":"1092","DOI":"10.1016\/S0002-9149(84)80150-2","article-title":"Reproducibility of Doppler aortic blood flow measurements: studies on intraobserver, interobserver and day-to-day variability in normal subjects","volume":"54","year":"1984","journal-title":"Am J Cardiol"},{"issue":"11","key":"bib23-20250806","doi-asserted-by":"crossref","first-page":"1628","DOI":"10.1111\/echo.12928","article-title":"Accuracy of echocardiographic cardiac index assessment in subjects with preserved left ventricular ejection fraction","volume":"32","year":"2015","journal-title":"Echocardiography"},{"issue":"8","key":"bib24-20250806","doi-asserted-by":"crossref","first-page":"1223","DOI":"10.1007\/s00134-016-4258-y","article-title":"Systematic review of cardiac output measurements by echocardiography vs. thermodilution: the techniques are not interchangeable","volume":"42","year":"2016","journal-title":"Intensive Care Med"},{"issue":"2","key":"bib25-20250806","doi-asserted-by":"crossref","first-page":"73","DOI":"10.1016\/j.medin.2017.11.012","article-title":"Lack of correlation between left ventricular outflow tract velocity time integral and stroke volume index in mechanically ventilated patients","volume":"43","year":"2019","journal-title":"Med Intensiva (Engl Ed)"},{"key":"bib26-20250806","doi-asserted-by":"crossref","first-page":"449","DOI":"10.1097\/SHK.0000000000001273","article-title":"A new echocardiographic tool for cardiac output evaluation: an experimental study","volume":"52","year":"2019","journal-title":"Shock"},{"key":"bib27-20250806","doi-asserted-by":"crossref","first-page":"826","DOI":"10.1016\/j.bja.2020.11.039","article-title":"Machine learning methods to improve bedside fluid responsiveness prediction in severe sepsis or septic shock: an observational study","volume":"126","year":"2021","journal-title":"Br J Anaesth"},{"issue":"7","key":"bib28-20250806","doi-asserted-by":"crossref","first-page":"419","DOI":"10.1002\/jcu.21882","article-title":"Influence of acute preload changes on mitral annulus velocity measured by tissue Doppler echocardiography in critically ill patients","volume":"40","year":"2012","journal-title":"J Clin Ultrasound"},{"issue":"9","key":"bib29-20250806","doi-asserted-by":"crossref","first-page":"1461","DOI":"10.1007\/s00134-012-2618-9","article-title":"Improvement of left ventricular relaxation as assessed by tissue Doppler imaging in fluid-responsive critically ill septic patients","volume":"38","year":"2012","journal-title":"Intensive Care Med"},{"issue":"7","key":"bib30-20250806","doi-asserted-by":"crossref","first-page":"1164","DOI":"10.1007\/s00134-016-4357-9","article-title":"Ten situations where inferior vena cava ultrasound may fail to accurately predict fluid responsiveness: a physiologically based point of view","volume":"42","year":"2016","journal-title":"Intensive Care Med"},{"key":"bib31-20250806","doi-asserted-by":"crossref","first-page":"246","DOI":"10.1016\/j.jcrc.2016.07.023","article-title":"Inferior vena cava diameter variation compared with pulse pressure variation as predictors of fluid responsiveness in patients with sepsis","volume":"36","year":"2016","journal-title":"J Crit Care"},{"issue":"2","key":"bib32-20250806","first-page":"240","article-title":"Inferior vena cava evaluation in fluid therapy decision making in intensive care: practical implications","volume":"31","year":"2019","journal-title":"Rev Bras Ter Intensiva"},{"issue":"5","key":"bib33-20250806","doi-asserted-by":"crossref","first-page":"550","DOI":"10.1097\/SHK.0000000000000801","article-title":"Does respiratory variation in inferior vena cava diameter predict fluid responsiveness: a systematic review and meta-analysis","volume":"47","year":"2017","journal-title":"Shock"},{"issue":"1","key":"bib34-20250806","doi-asserted-by":"crossref","first-page":"108","DOI":"10.1186\/s13049-016-0298-0","article-title":"The assessment of circulating volume using inferior vena cava collapse index and carotid Doppler velocity time integral in healthy volunteers: a pilot study","volume":"24","year":"2016","journal-title":"Scand J Trauma Resusc Emerg Med"},{"issue":"1","key":"bib35-20250806","doi-asserted-by":"crossref","first-page":"104","DOI":"10.1186\/s13049-018-0571-5","article-title":"Investigating the ability of non-invasive measures of cardiac output to detect a reduction in blood volume resulting from venesection in spontaneously breathing subjects","volume":"26","year":"2018","journal-title":"Scand J Trauma Resusc Emerg Med"},{"issue":"6","key":"bib36-20250806","doi-asserted-by":"crossref","first-page":"774","DOI":"10.4187\/respcare.04651","article-title":"Should a tidal volume of 6 mL\/kg be used in all patients?","volume":"61","year":"2016","journal-title":"Respir Care"},{"key":"bib37-20250806","first-page":"153","article-title":"Management of hemorrhagic shock in intensive care units: principles and practices","volume":"17","year":"2008","journal-title":"Reanimation"}],"container-title":["Journal of Trauma and Acute Care Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/TA.0000000000003518","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,8,6]],"date-time":"2025-08-06T16:05:28Z","timestamp":1754496328000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/TA.0000000000003518"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,1,4]]},"references-count":37,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2022]]}},"URL":"https:\/\/doi.org\/10.1097\/ta.0000000000003518","relation":{},"ISSN":["2163-0763","2163-0755"],"issn-type":[{"value":"2163-0763","type":"electronic"},{"value":"2163-0755","type":"print"}],"subject":[],"published":{"date-parts":[[2022,1,4]]}}}