{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,21]],"date-time":"2026-11-21T01:05:40Z","timestamp":1795223140240,"version":"4.10.3"},"reference-count":18,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"2","license":[{"start":{"date-parts":[[2026,6,1]],"date-time":"2026-06-01T00:00:00Z","timestamp":1780272000000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2026,8]]},"abstract":"<jats:sec>\n                    <jats:title>ABSTRACT:<\/jats:title>\n                    <jats:p>Recent updates to the Joint Trauma System clinical practice guidelines for resuscitative endovascular balloon occlusion of the aorta incorporate partial aortic occlusion (PAO) for up to two hours in combat casualty care following US Food and Drug Administration 510(k) clearance of the pREBOA-PRO catheter for partial Zone 1 occlusion under defined physiologic parameters. The FDA clearance specifies physiologic targets, including proximal systolic blood pressure of 90 to 110\u00a0mm Hg and distal systolic blood pressure &gt;20\u00a0mm Hg with pulsatility, indicating that extended occlusion duration is contingent on active titration and physiologic monitoring. These parameters suggest that PAO may be better conceptualized as delivery of a controlled \u201cischemic dose\u201d determined by both occlusion intensity and duration rather than elapsed time alone. However, real-time ischemic monitoring is limited, distal arterial pressure represents only a surrogate for distal flow, and the relationship between pressure and flow during partial occlusion may vary across catheter designs. This opinion reviews the physiologic basis of PAO, the device-specific context of the two-hour safety window, and the limitations of current monitoring technologies. We also discuss implications for resuscitation strategy and reperfusion planning in austere and prolonged casualty care environments and outline future research priorities.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1097\/ta.0000000000005065","type":"journal-article","created":{"date-parts":[[2026,6,1]],"date-time":"2026-06-01T10:07:24Z","timestamp":1780308444000},"page":"S162-S167","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":1,"title":["Interpreting the two-hour partial REBOA safety window: Physiologic context, monitoring limitations, and device-specific considerations"],"prefix":"10.1097","volume":"101","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-5971-5508","authenticated-orcid":false,"given":"Rachel M.","family":"Russo","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bellal","family":"Joseph","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2026,6,1]]},"reference":[{"key":"R3-20260930","doi-asserted-by":"crossref","first-page":"101","DOI":"10.1016\/j.jss.2020.12.054","article-title":"Partial resuscitative endovascular balloon occlusion of the aorta: a systematic review of the preclinical and clinical literature","volume":"262","author":"Russo","year":"2021","journal-title":"J Surg Res"},{"issue":"1","key":"R4-20260930","doi-asserted-by":"crossref","first-page":"e000984","DOI":"10.1136\/tsaco-2022-000984","article-title":"Systematic review to evaluate algorithms for REBOA use in trauma and identify a consensus for patient selection","volume":"7","author":"Maiga","year":"2022","journal-title":"J Trauma Acute Care Surg"},{"key":"R5-20260930","first-page":"1097","article-title":"A Delphi Consensus Algorithm for Modern REBOA Programs: employing a titratable catheter and partial aortic occlusion to advance the procedure","volume":"10","author":"Nguyen","year":"2023","journal-title":"Shock"},{"issue":"6","key":"R6-20260930","doi-asserted-by":"crossref","first-page":"1106","DOI":"10.1097\/TA.0000000000001446","article-title":"Small changes, big effects: the hemodynamics of partial and complete aortic occlusion to inform next generation resuscitation techniques and technologies","volume":"82","author":"Johnson","year":"2017","journal-title":"J Trauma Acute Care Surg"},{"key":"R7-20260930","doi-asserted-by":"crossref","first-page":"171","DOI":"10.1016\/j.jss.2020.06.042","article-title":"A new pressure-regulated, partial resuscitative endovascular balloon occlusion of the aorta device achieves targeted distal perfusion","volume":"256","author":"White","year":"2020","journal-title":"J Surg Res"},{"issue":"1","key":"R9-20260930","doi-asserted-by":"crossref","first-page":"139","DOI":"10.1097\/TA.0000000000001502","article-title":"Incremental balloon deflation following complete resuscitative endovascular balloon occlusion of the aorta results in steep inflection of flow and rapid reperfusion in a large animal model of hemorrhagic shock","volume":"83","author":"Davidson","year":"2017","journal-title":"J Trauma Acute Care Surg"},{"issue":"9","key":"R10-20260930","doi-asserted-by":"crossref","first-page":"998","DOI":"10.1001\/jamasurg.2024.2254","article-title":"Prehospital partial resuscitative endovascular balloon occlusion of the aorta for exsanguinating subdiaphragmatic hemorrhage","volume":"159","author":"Lendrum","year":"2024","journal-title":"JAMA Surgery"},{"issue":"2S Suppl 1","key":"R11-20260930","doi-asserted-by":"crossref","first-page":"S129","DOI":"10.1097\/TA.0000000000004053","article-title":"Prolonging the zone 1 aortic occlusion time to 4 hours using a partial resuscitative endovascular balloon in a swine model","volume":"95","author":"Ho","year":"2023","journal-title":"J Trauma Acute Care Surg"},{"issue":"3","key":"R12-20260930","doi-asserted-by":"crossref","first-page":"426","DOI":"10.1097\/TA.0000000000003042","article-title":"A novel partial resuscitative endovascular balloon aortic occlusion device that can be deployed in zone 1 for more than 2 hours with minimal provider titration","volume":"90","author":"Kemp","year":"2021","journal-title":"J Trauma Acute Care Surg"},{"issue":"1","key":"R13-20260930","doi-asserted-by":"crossref","first-page":"32","DOI":"10.1097\/XCS.0000000000000881","article-title":"Finding the right balance: partial REBOA in a swine model of uncontrolled vascular injury","volume":"238","author":"Ho","year":"2024","journal-title":"J Am Coll Surg"},{"issue":"Suppl 3","key":"R14-20260930","doi-asserted-by":"crossref","first-page":"284","DOI":"10.1093\/milmed\/usae095","article-title":"A PROMPT update on partial reboa: initial clinical data and overview of the DoD-funded Partial REBOA Outcomes Multicenter ProspecTive (PROMPT) study","volume":"189","author":"Gondek","year":"2024","journal-title":"Mil Med"},{"issue":"2S","key":"R15-20260930","doi-asserted-by":"crossref","first-page":"S39","DOI":"10.1097\/TA.0000000000002761","article-title":"Reperfusion repercussions: a review of the metabolic derangements following resuscitative endovascular balloon occlusion of the aorta","volume":"89","author":"Abid","year":"2020","journal-title":"J Trauma Acute Care Surg"},{"issue":"1","key":"R16-20260930","doi-asserted-by":"crossref","first-page":"e000194","DOI":"10.1136\/tsaco-2018-000194","article-title":"Extended resuscitative endovascular balloon occlusion of the aorta (REBOA)-induced type 2 myocardial ischemia: a time-dependent penalty","volume":"4","author":"Wasicek","year":"2019","journal-title":"Trauma Surg Acute Care Open"},{"issue":"3","key":"R17-20260930","doi-asserted-by":"crossref","first-page":"544","DOI":"10.1097\/01.ta.0000530846.79191.69","article-title":"The pitfalls of resuscitative endovascular balloon occlusion of the aorta: Risk factors and mitigation strategies (vol 84, pg 192, 2018)","volume":"84","author":"Davidson","year":"2018","journal-title":"J Trauma Acute Care Surg"},{"issue":"6","key":"R18-20260930","doi-asserted-by":"crossref","first-page":"1039","DOI":"10.1097\/TA.0000000000001143","article-title":"Smaller introducer sheaths for REBOA may be associated with fewer complications","volume":"81","author":"Teeter","year":"2016","journal-title":"J Trauma Acute Care Surg"},{"issue":"1","key":"R19-20260930","doi-asserted-by":"crossref","first-page":"63","DOI":"10.1007\/s40140-018-0259-4","article-title":"Anesthetic considerations utilizing resuscitative endovascular balloon occlusion of the aorta in the hemorrhaging trauma patient","volume":"8","author":"Chauhan","year":"2018","journal-title":"Current Anesthesiology Reports"},{"issue":"3","key":"R20-20260930","doi-asserted-by":"crossref","first-page":"648","DOI":"10.1016\/j.kint.2015.09.002","article-title":"Prolonged warm ischemia time is associated with graft failure and mortality after kidney transplantation","volume":"89","author":"Tennankore","year":"2016","journal-title":"Kidney Int"},{"issue":"3","key":"R21-20260930","doi-asserted-by":"crossref","first-page":"e0123421","DOI":"10.1371\/journal.pone.0123421","article-title":"Warm ischemic injury is reflected in the release of injury markers during cold preservation of the human liver","volume":"10","author":"Bruinsma","year":"2015","journal-title":"PLoS One"}],"container-title":["Journal of Trauma and Acute Care Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.1097\/TA.0000000000005065","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,9,30]],"date-time":"2026-09-30T18:00:25Z","timestamp":1790791225000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.1097\/TA.0000000000005065"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,6,1]]},"references-count":18,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2026]]}},"URL":"https:\/\/doi.org\/10.1097\/ta.0000000000005065","relation":{},"ISSN":["2163-0755","2163-0763"],"issn-type":[{"value":"2163-0755","type":"print"},{"value":"2163-0763","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,6,1]]},"assertion":[{"value":"2026-02-05","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2026-04-19","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}