{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,7]],"date-time":"2026-08-07T16:10:59Z","timestamp":1786119059845,"version":"build-2736575974"},"reference-count":32,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"6","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2008,12]]},"DOI":"10.1097\/ta.0b013e3180f62643","type":"journal-article","created":{"date-parts":[[2008,12,3]],"date-time":"2008-12-03T03:43:37Z","timestamp":1228275817000},"page":"1396-1401","source":"Crossref","is-referenced-by-count":14,"title":["Esophageal echo-Doppler Monitoring in Burn Shock Resuscitation: Are Hemodynamic Variables the Critical Standard Guiding Fluid Therapy?"],"prefix":"10.1097","volume":"65","author":[{"given":"Guang-Yi","family":"Wang","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bing","family":"Ma","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hong-Tai","family":"Tang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shi-Hui","family":"Zhu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jian","family":"Lu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Wei","family":"Wei","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sheng-De","family":"Ge","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zhao-Fan","family":"Xia","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-31-20210211","doi-asserted-by":"crossref","first-page":"811","DOI":"10.1016\/0002-9610(78)90172-1","article-title":"Pulmonary artery catheterization and thermodilution cardiac output determination in the management of critically burned patients.","volume":"135","author":"Aikawa","year":"1978","journal-title":"Am J Surg"},{"key":"R2-31-20210211","doi-asserted-by":"crossref","first-page":"327","DOI":"10.1097\/00003246-199103000-00007","article-title":"Adequate resuscitation of burn patients may not be measured by urine output and vital signs.","volume":"19","author":"Dries","year":"1991","journal-title":"Crit Care Med"},{"key":"R3-31-20210211","doi-asserted-by":"crossref","first-page":"696","DOI":"10.1016\/S0002-9610(99)80044-0","article-title":"Survival is predicted by early response to Swan-Ganz resuscitation in major burn injuries.","volume":"170","author":"Schiller","year":"1995","journal-title":"Am J Surg"},{"key":"R4-31-20210211","doi-asserted-by":"crossref","first-page":"10","DOI":"10.1097\/00004630-199701000-00002","article-title":"Hyperdynamic resuscitation improves survival in patients with life-threatening burns.","volume":"18","author":"Schiller","year":"1997","journal-title":"J Burn Care Rehabil"},{"key":"R5-31-20210211","doi-asserted-by":"crossref","first-page":"157","DOI":"10.1016\/S0300-9572(00)00159-3","article-title":"Burn shock resuscitation: tradition or evidence based medicine?","volume":"44","author":"Holm","year":"2000","journal-title":"Resuscitation"},{"key":"R6-31-20210211","first-page":"1585","article-title":"Burn shock fluid resuscitation regime revised by invasive hemodynamic monitoring.","volume":"85","author":"Guo","year":"2005","journal-title":"Zhonghua Yi Xue Za Zhi"},{"key":"R7-31-20210211","doi-asserted-by":"crossref","first-page":"37","DOI":"10.1016\/j.resuscitation.2005.12.001","article-title":"Correlations between cardiac output, stroke volume, central venous pressure, intra-abdominal pressure and total circulating blood volume in resuscitation of major burns.","volume":"70","author":"Kuntscher","year":"2006","journal-title":"Resuscitation"},{"key":"R8-31-20210211","doi-asserted-by":"crossref","first-page":"728","DOI":"10.1097\/00005373-200004000-00023","article-title":"Intrathoracic blood volume as an end point in resuscitation of the severely burned: an observational study of 24 patients.","volume":"48","author":"Holm","year":"2000","journal-title":"J Trauma"},{"key":"R9-31-20210211","doi-asserted-by":"crossref","first-page":"550","DOI":"10.1055\/s-2006-951611","article-title":"Invasive cardiovascular monitoring-four methods compared.","volume":"41","author":"Stubbe","year":"2006","journal-title":"Anasthesiol Intensivmed Notfallmed Schmerzther"},{"key":"R10-31-20210211","doi-asserted-by":"crossref","first-page":"254","DOI":"10.1093\/bja\/aeg521","article-title":"Continuous and intermittent cardiac output measurement: pulmonary artery catheter versus aortic transpulmonary technique.","volume":"90","author":"Tzenkov","year":"2003","journal-title":"Br J Anaesth"},{"key":"R11-31-20210211","doi-asserted-by":"crossref","first-page":"798","DOI":"10.1016\/j.burns.2004.06.016","article-title":"A clinical randomized study on the effects of invasive monitoring on burn shock resuscitation.","volume":"30","author":"Holm","year":"2004","journal-title":"Burns"},{"key":"R12-31-20210211","doi-asserted-by":"crossref","first-page":"371","DOI":"10.1016\/j.resuscitation.2006.07.010","article-title":"Decreased fluid volume to reduce organ damage: a new approach to burn shock resuscitation? A preliminary study.","volume":"72","author":"Arlati","year":"2007","journal-title":"Resuscitation"},{"key":"R13-31-20210211","doi-asserted-by":"crossref","first-page":"978","DOI":"10.1007\/BF03022062","article-title":"Esophageal Doppler and thermodilution are not interchangeable for determination of cardiac output.","volume":"52","author":"Collins","year":"2005","journal-title":"Can J Anaesth"},{"key":"R14-31-20210211","doi-asserted-by":"crossref","first-page":"189","DOI":"10.1016\/j.ccell.2006.02.004","article-title":"Esophageal Doppler monitoring for hemodynamic assessment.","volume":"18","author":"Prentice","year":"2006","journal-title":"Crit Care Nurs Clin North Am"},{"key":"R15-31-20210211","doi-asserted-by":"crossref","first-page":"658","DOI":"10.1016\/j.ajem.2006.02.006","article-title":"A prospective study on esophageal Doppler hemodynamic assessment in the ED.","volume":"24","author":"Rodriguez","year":"2006","journal-title":"Am J Emerg Med"},{"key":"R16-31-20210211","first-page":"506","article-title":"Use of non-invasive esophageal echo-Doppler system in the ICU: a practical experience.","volume":"59","author":"Stawicki","year":"2005","journal-title":"J Trauma"},{"key":"R17-31-20210211","doi-asserted-by":"crossref","first-page":"607","DOI":"10.1097\/00005373-199904000-00008","article-title":"Esophageal Doppler ultrasound monitor versus pulmonary artery catheter in the hemodynamic management of critically ill surgical patients.","volume":"46","author":"Madan","year":"1999","journal-title":"J Trauma"},{"key":"R18-31-20210211","doi-asserted-by":"crossref","first-page":"1013","DOI":"10.1097\/01.TA.0000105925.51950.08","article-title":"Comparison of cardiac outputs of major burn patients undergoing extensive early escharectomy: esophageal Doppler monitor versus thermodilution pulmonary artery catheter.","volume":"57","author":"Kim","year":"2004","journal-title":"J Trauma"},{"key":"R19-31-20210211","doi-asserted-by":"crossref","first-page":"220","DOI":"10.1097\/00044067-200305000-00011","article-title":"Doppler-based hemodynamic monitoring: a minimally invasive alternative.","volume":"14","author":"Turner","year":"2003","journal-title":"AACN Clin Issues"},{"key":"R20-31-20210211","doi-asserted-by":"crossref","first-page":"393","DOI":"10.1007\/BF03017329","article-title":"Utility of esophageal Doppler as a minimally invasive hemodynamic monitor: a review.","volume":"49","author":"Laupland","year":"2002","journal-title":"Can J Anaesth"},{"key":"R21-31-20210211","doi-asserted-by":"crossref","first-page":"127","DOI":"10.1023\/A:1009902517388","article-title":"Non-invasive cardiac monitoring by aortic blood flow measurement with the Dynemo 3000.","volume":"16","author":"Boulnois","year":"2000","journal-title":"J Clin Monit Comput"},{"key":"R22-31-20210211","doi-asserted-by":"crossref","first-page":"16","DOI":"10.1007\/BF02067109","article-title":"Burn shock resuscitation.","volume":"16","author":"Warden","year":"1992","journal-title":"World J Surg"},{"key":"R23-31-20210211","first-page":"272","article-title":"An experimental study on the change in cardiac sympathetic neuroelectrophysiology in severely scalded rats during early postburn stage.","volume":"17","author":"Tang","year":"2001","journal-title":"Zhonghua Shao Shang Za Zhi"},{"key":"R24-31-20210211","first-page":"745","article-title":"Cardiac contractile dysfunction in response to surgical stress including trauma, hemorrhage, and infection.","volume":"97","author":"Suzuki","year":"1996","journal-title":"Nippon Geka Gakkai Zasshi"},{"key":"R25-31-20210211","doi-asserted-by":"crossref","first-page":"410","DOI":"10.1016\/0305-4179(86)90036-7","article-title":"The relationship between postburn increases in peripheral resistance and vasopressin.","volume":"12","author":"Hilton","year":"1986","journal-title":"Burns"},{"key":"R26-31-20210211","doi-asserted-by":"crossref","first-page":"91","DOI":"10.1097\/00004630-200021020-00002","article-title":"A biopsy of the use of the Baxter formula to resuscitate burns or do we do it like Charlie did it?","volume":"21","author":"Engrav","year":"2000","journal-title":"J Burn Care Rehabil"},{"key":"R27-31-20210211","doi-asserted-by":"crossref","first-page":"258","DOI":"10.1097\/00004630-200207000-00006","article-title":"How well does the Parkland formula estimate actual fluid resuscitation volumes?","volume":"23","author":"Cartotto","year":"2002","journal-title":"J Burn Care Rehabil"},{"key":"R28-31-20210211","doi-asserted-by":"crossref","first-page":"549","DOI":"10.1016\/0305-4179(96)00023-X","article-title":"Use of invasive cardiovascular monitoring in patients with burns greater than 30% body surface area: a survey of 251 centres.","volume":"22","author":"Mansfield","year":"1996","journal-title":"Burns"},{"key":"R29-31-20210211","doi-asserted-by":"crossref","first-page":"613","DOI":"10.1016\/S0305-4179(02)00056-6","article-title":"Fluid resuscitation for burns: a double edge weapon. Letter to the editor.","volume":"28","author":"Kumar","year":"2002","journal-title":"Burns"},{"key":"R30-31-20210211","doi-asserted-by":"crossref","first-page":"874","DOI":"10.1111\/j.1749-6632.1968.tb14738.x","article-title":"Physiological response to crystalloid resuscitation of severe burns.","volume":"150","author":"Baxter","year":"1968","journal-title":"Ann N Y Acad Sci"},{"key":"R31-31-20210211","first-page":"S48","article-title":"Practice guidelines for burn care.","volume":"22","year":"2001","journal-title":"J Burn Care Rehabil"},{"key":"R32-31-20210211","first-page":"505","article-title":"The esophageal Doppler monitor is useful for fluid management during the perioperative and intensive care periods.","volume":"59","author":"Han","year":"2005","journal-title":"J Trauma"}],"container-title":["Journal of Trauma: Injury, Infection &amp; Critical Care"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.1097\/TA.0b013e3180f62643","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,6]],"date-time":"2026-08-06T17:25:28Z","timestamp":1786037128000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/00005373-200812000-00031"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2008,12]]},"references-count":32,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2008]]}},"URL":"https:\/\/doi.org\/10.1097\/ta.0b013e3180f62643","relation":{},"ISSN":["0022-5282"],"issn-type":[{"value":"0022-5282","type":"print"}],"subject":[],"published":{"date-parts":[[2008,12]]}}}