{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,7]],"date-time":"2026-08-07T16:08:15Z","timestamp":1786118895582,"version":"build-2736575974"},"reference-count":30,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"5","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2008,5]]},"DOI":"10.1097\/ta.0b013e31815e40e0","type":"journal-article","created":{"date-parts":[[2008,5,5]],"date-time":"2008-05-05T04:10:53Z","timestamp":1209960653000},"page":"1275-1280","source":"Crossref","is-referenced-by-count":28,"title":["Titanium Alloy Pins Versus Stainless Steel Pins in External Fixation at the Wrist: A Randomized Prospective Study"],"prefix":"10.1097","volume":"64","author":[{"given":"Oliver","family":"Pieske","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Patrizia","family":"Geleng","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Johannes","family":"Zaspel","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Stefan","family":"Piltz","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-17-20210211","doi-asserted-by":"crossref","first-page":"243","DOI":"10.1302\/0301-620X.80B2.0800243","article-title":"Epidemiology of fractures in 15,000 adults: the influence of age and gender.","volume":"2","author":"Singer","year":"1998","journal-title":"J Bone Joint Surg Br"},{"key":"R2-17-20210211","doi-asserted-by":"crossref","first-page":"970","DOI":"10.1097\/00005373-199806000-00007","article-title":"Long-term results of the external fixation of distal radius fractures.","volume":"44","author":"Rikli","year":"1998","journal-title":"J Trauma"},{"key":"R3-17-20210211","first-page":"1185","article-title":"A meta-analysis of outcomes of external fixation versus plate osteosynthesis for unstable distal radius fractures.","volume":"6","author":"Margaliot","year":"2005","journal-title":"J Hand Surg [Am]"},{"key":"R4-17-20210211","first-page":"109","article-title":"Complications of external skeletal fixation.","volume":"180","author":"Green","year":"1983","journal-title":"Clin Orthop Relat Res"},{"key":"R5-17-20210211","first-page":"53","article-title":"Complications of treating distal radius fractures with external fixation: a community experience.","author":"Anderson","year":"2004","journal-title":"Iowa Orthop J"},{"key":"R6-17-20210211","first-page":"305","article-title":"Factors in pin tract infections.","volume":"3","author":"Mahan","year":"1991","journal-title":"Orthopedics"},{"key":"R7-17-20210211","doi-asserted-by":"crossref","first-page":"116","DOI":"10.3109\/17453679909011246","article-title":"Pin-tract complications in external fixation of fractures of the distal radius.","volume":"2","author":"Ahlborg","year":"1999","journal-title":"Acta Orthop Scand"},{"issue":"S4","key":"R8-17-20210211","doi-asserted-by":"crossref","first-page":"2","DOI":"10.1016\/S0020-1383(00)80015-7","article-title":"Stainless steel in bone surgery.","volume":"31","author":"Disegi","year":"2000","journal-title":"Injury"},{"key":"R9-17-20210211","doi-asserted-by":"crossref","first-page":"647","DOI":"10.1302\/0301-620X.78B4.0780647","article-title":"Influence of materials for fixation implants on local infection. An experimental study of steel versus titanium DCP in rabbits.","volume":"4","author":"Arens","year":"1996","journal-title":"J Bone Joint Surg Br"},{"key":"R10-17-20210211","first-page":"96","article-title":"Removal torques of small screws of steel and titanium with different surfaces.","volume":"3","author":"Eulenberger","year":"1990","journal-title":"Unfallchirurg"},{"key":"R11-17-20210211","doi-asserted-by":"crossref","first-page":"476","DOI":"10.1097\/00005131-200608000-00005","article-title":"Bacterial adherence to tantalum versus commonly used orthopedic metallic implant materials.","volume":"7","author":"Schildhauer","year":"2006","journal-title":"J Orthop Trauma"},{"key":"R12-17-20210211","doi-asserted-by":"crossref","first-page":"S67","DOI":"10.1016\/j.injury.2006.04.011","article-title":"Surgical aspects of infection involving osteosynthesis implants: implant design and resistance to local infection.","author":"Schlegel","year":"2006","journal-title":"Injury"},{"key":"R13-17-20210211","doi-asserted-by":"crossref","first-page":"189","DOI":"10.1097\/00005131-200203000-00009","article-title":"State of the art review: techniques to avoid pin loosening and infection in external fixation.","volume":"3","author":"Moroni","year":"2002","journal-title":"J Orthop Trauma"},{"issue":"S4","key":"R14-17-20210211","doi-asserted-by":"crossref","first-page":"14","DOI":"10.1016\/S0020-1383(00)80017-0","article-title":"Titanium alloys for fracture fixation implants.","volume":"31","author":"Disegi","year":"2000","journal-title":"Injury"},{"key":"R15-17-20210211","doi-asserted-by":"crossref","first-page":"18","DOI":"10.1097\/00003086-199308000-00004","article-title":"Analysis of the external fixator pin-bone interface.","volume":"293","author":"Pettine","year":"1993","journal-title":"Clin Orthop Relat Res"},{"key":"R16-17-20210211","doi-asserted-by":"crossref","first-page":"315","DOI":"10.3109\/17453679809000938","article-title":"Tensile bond between bone and titanium: a reappraisal of osseointegration.","volume":"3","author":"Skripitz","year":"1998","journal-title":"Acta Orthop Scand"},{"key":"R17-17-20210211","doi-asserted-by":"crossref","first-page":"157","DOI":"10.1002\/jbm.820290204","article-title":"Bone-bonding behavior of titanium alloy evaluated mechanically with detaching failure load.","volume":"2","author":"Takatsuka","year":"1995","journal-title":"J Biomed Mater Res"},{"key":"R18-17-20210211","doi-asserted-by":"crossref","first-page":"888","DOI":"10.1302\/0301-620X.80B5.0800888","article-title":"Anti-inflammatory properties of titanium in the joint environment. An experimental study in rats.","volume":"5","author":"Overgaard","year":"1998","journal-title":"J Bone Joint Surg Br"},{"key":"R19-17-20210211","doi-asserted-by":"crossref","first-page":"311","DOI":"10.1007\/BF00636167","article-title":"Clinical experience with titanium implants, especially with the limited contact dynamic compression plate system.","volume":"6","author":"Matter","year":"1990","journal-title":"Arch Orthop Trauma Surg"},{"key":"R20-17-20210211","doi-asserted-by":"crossref","first-page":"97","DOI":"10.1007\/s005860050218","article-title":"Titanium-alloy enhances bone-pedicle screw fixation: mechanical and histomorphometrical results of titanium-alloy versus stainless steel.","volume":"2","author":"Christensen","year":"2000","journal-title":"Eur Spine J"},{"key":"R21-17-20210211","doi-asserted-by":"crossref","first-page":"59","DOI":"10.1007\/s00068-007-6053-5","article-title":"An in vivo experimental comparison of stainless steel and titanium schanz screws for external fixation.","volume":"1","author":"Ganser","year":"2007","journal-title":"Eur J Trauma Emerg Surg"},{"key":"R22-17-20210211","doi-asserted-by":"crossref","first-page":"147","DOI":"10.1097\/00003086-199102000-00017","article-title":"The surgical treatment of severe comminuted intraarticular fractures of the distal radius with the small AO external fixation device. A prospective three-and-one-half-year follow-up study.","volume":"263","author":"Horesh","year":"1991","journal-title":"Clin Orthop Relat Res"},{"key":"R23-17-20210211","article-title":"International Standard, 3rd ed.","year":"1997"},{"key":"R24-17-20210211","doi-asserted-by":"crossref","DOI":"10.1007\/978-3-642-61261-9","article-title":"The Comprehensive Classification of Fractures of Long Bones.","author":"M\u00fcller","year":"1990"},{"key":"R25-17-20210211","doi-asserted-by":"crossref","first-page":"453","DOI":"10.2106\/00004623-197658040-00004","article-title":"Prevention of infection in the treatment of one thousand and twenty-five open fractures of long bones: retrospective and prospective analyses.","volume":"4","author":"Gustilo","year":"1976","journal-title":"J Bone Joint Surg Am"},{"issue":"Suppl","key":"R26-17-20210211","first-page":"16","article-title":"Pin track infection: definition, incidence, and prevention.","volume":"3","author":"Checketts","year":"1993","journal-title":"J Orthop Trauma"},{"key":"R27-17-20210211","first-page":"CD004551","article-title":"Pin site care for preventing infections associated with external bone fixators and pins.","volume":"1","author":"Temple","year":"2004","journal-title":"Cochrane Database Syst Rev"},{"key":"R28-17-20210211","doi-asserted-by":"crossref","first-page":"369","DOI":"10.1007\/s00402-006-0142-5","article-title":"The fixation strength of hydroxyapatite-coated Schanz screws and standard stainless steel Schanz screws in lower extremity lengthening: a comparison based on a new torque value index: the fixation index.","volume":"6","author":"Placzek","year":"2006","journal-title":"Arch Orthop Trauma Surg"},{"key":"R29-17-20210211","doi-asserted-by":"crossref","first-page":"892","DOI":"10.1302\/0301-620X.86B6.13875","article-title":"Hydroxyapatite-coated external-fixation pins. The effect on pin loosening and pin-track infection in leg lengthening for short stature.","volume":"6","author":"Piza","year":"2004","journal-title":"J Bone Joint Surg Br"},{"key":"R30-17-20210211","doi-asserted-by":"crossref","first-page":"1588","DOI":"10.1126\/science.3629258","article-title":"Biomaterial-centered infection: microbial adhesion versus tissue integration.","volume":"4822","author":"Gristina","year":"1987","journal-title":"Science"}],"container-title":["Journal of Trauma: Injury, Infection &amp; Critical Care"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.1097\/TA.0b013e31815e40e0","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,6]],"date-time":"2026-08-06T16:59:40Z","timestamp":1786035580000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/00005373-200805000-00017"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2008,5]]},"references-count":30,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2008]]}},"URL":"https:\/\/doi.org\/10.1097\/ta.0b013e31815e40e0","relation":{},"ISSN":["0022-5282"],"issn-type":[{"value":"0022-5282","type":"print"}],"subject":[],"published":{"date-parts":[[2008,5]]}}}