{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,16]],"date-time":"2026-01-16T17:03:04Z","timestamp":1768582984355,"version":"3.49.0"},"reference-count":15,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"1","license":[{"start":{"date-parts":[[2026,1,1]],"date-time":"2026-01-01T00:00:00Z","timestamp":1767225600000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2026,1]]},"abstract":"<jats:sec>\n                    <jats:title>PURPOSE:<\/jats:title>\n                    <jats:p>The purpose of this analysis was to compare urinary tract infection (UTI) rates, health-related quality of life (QoL) and intermittent catheter (IC) experience, and satisfaction among participants who used hydrophilic ICs with a ring cap, protective introducer tip, and sleeve (Group A) to those who used ICs without this combination of features (Group B).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>DESIGN:<\/jats:title>\n                    <jats:p>Analysis of data from a prospective, observational, longitudinal continence care registry.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>SUBJECTS AND SETTING:<\/jats:title>\n                    <jats:p>The sample comprised 222 monthly or quarterly electronic patient-reported outcome registry visits across 32 intermittent self-catheterization (ISC) users from the US, Canada, and the UK. Participants self-reported data directly into a secure cloud-based electronic data capture system.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>METHODS:<\/jats:title>\n                    <jats:p>Generalized linear mixed models that were capable of modeling the longitudinal nature of the data structure within the registry were employed. These models were used to compare UTI odds, QoL scores based on the Intermittent Self-Catheterization Questionnaire (ISC-Q), and ISC satisfaction and experience ratings between the 2 groups.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>RESULTS:<\/jats:title>\n                    <jats:p>\n                      Group A had a significantly lower likelihood of experiencing a UTI than Group B (odds ratio\u00a0=\u00a00.38;\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      =\u00a0.035). Furthermore, total ISC-Q scores for Group A were significantly greater than Group B (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      =\u00a0.044). The ISC-Q difference of 8.85 points exceeded the ISC-Q minimum important difference range of 4.94 to 8.73 points, indicating a clinically relevant difference in QoL for Group A compared to Group B. Additionally, ISC users from Group A reported significantly greater satisfaction and more positive ISC experiences compared to IC users from Group B.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>CONCLUSIONS:<\/jats:title>\n                    <jats:p>Participants using hydrophilic ICs with a ring cap, protective introducer tip, and sleeve (Group A) demonstrated significantly lower UTI risk, greater QoL, and better ISC satisfaction and experience than participants who used ICs from Group B. These findings indicate the beneficial use of Group A hydrophilic ICs.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1097\/won.0000000000001249","type":"journal-article","created":{"date-parts":[[2026,1,16]],"date-time":"2026-01-16T05:01:35Z","timestamp":1768539695000},"page":"40-46","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":0,"title":["Intermittent Catheters With Integrated Features Designed to Reduce the Risk of Urinary Tract Infection"],"prefix":"10.1097","volume":"53","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-8059-3608","authenticated-orcid":false,"given":"Daniel","family":"Gordon","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"George","family":"Skountrianos","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Diane K.","family":"Newman","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jessica","family":"Simmons","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","published-online":{"date-parts":[[2026,1,10]]},"reference":[{"key":"R1-20260116","doi-asserted-by":"crossref","first-page":"1555","DOI":"10.1007\/s00345-018-2419-z","article-title":"Non-surgical urologic management of neurogenic bladder after spinal cord injury","volume":"36","author":"Romo","year":"2018","journal-title":"World J Urol"},{"key":"R2-20260116","first-page":"e022137","article-title":"Identifying the risk factors for catheter-associated urinary tract infections: a large cross-sectional study of six hospitals","volume":"9","author":"Leticia-Kriegel","year":"2019","journal-title":"Bmj"},{"key":"R3-20260116","doi-asserted-by":"crossref","first-page":"854","DOI":"10.1002\/nau.24253","article-title":"The impact of catheter-based bladder drainage method on urinary tract infection risk in spinal cord injury and neurogenic bladder: a systematic review","volume":"39","author":"Kinnear","year":"2020","journal-title":"Neurourol Urodyn"},{"key":"R4-20260116","doi-asserted-by":"crossref","first-page":"1443","DOI":"10.1007\/s11255-020-02435-9","article-title":"Intermittent catheterization with single- or multiple-reuse catheters: clinical study on safety and impact on quality of life","volume":"52","author":"Newman","year":"2020","journal-title":"Int Urol Nephrol"},{"key":"R10-20260116","first-page":"8(2014)","article-title":"Ensuring patient adherence to clean intermittent self-catheterization","author":"Seth","year":"2014","journal-title":"Patient Prefer Adherence"},{"key":"R11-20260116","first-page":"33","article-title":"Understanding the challenges faced by men learning to live with clean intermittent self catheterisation","volume":"33(9","author":"Logan","year":"2024"},{"key":"R13-20260116","first-page":"51","article-title":"Microbial transfer by intermittent catheters: an in vitro evaluation of microbial transfer in catheter with variable protective features","author":"Dean","year":"2024","journal-title":"J Wound Ostomy Continence Nurs"},{"key":"R14-20260116","first-page":"41","article-title":"Hydrophilic versus non-hydrophilic catheters for clean intermittent catheterization: a meta-analysis to determine their capacity in reducing urinary tract infections","author":"Plata","year":"2023","journal-title":"World J Urol"},{"key":"R27-20260116","doi-asserted-by":"crossref","first-page":"2302","DOI":"10.1016\/j.clinthera.2012.10.006","article-title":"Development and psychometric validation of the intermittent self-catheterization questionnaire","author":"Pinder","year":"2012","journal-title":"Clin Ther"},{"key":"R36-20260116","doi-asserted-by":"crossref","first-page":"1373","DOI":"10.1016\/S0895-4356(96)00236-3","article-title":"A simulation study of the number of events per variable in logistic regression analysis","volume":"49(12)","author":"Peduzzi","year":"1996","journal-title":"J Clin Epidemiol"},{"key":"R37-20260116","first-page":"CD001322","article-title":"Cranberries for treating urinary tract infections","author":"Jepson","year":"1998","journal-title":"Cochrane Database Syst Rev"},{"issue":"5","key":"R38-20260116","doi-asserted-by":"crossref","first-page":"519","DOI":"10.2217\/ahe.13.38","article-title":"Urinary tract infection in older adults","volume":"9","author":"Rowe","year":"2013","journal-title":"Aging Health"},{"issue":"9","key":"R40-20260116","doi-asserted-by":"crossref","first-page":"444","DOI":"10.12968\/bjcn.2021.26.9.444","article-title":"Barriers affecting patient adherence to intermittent self-catheterizations","volume":"26","author":"Balhi","year":"2021","journal-title":"Br J Community Nurs"},{"issue":"1","key":"R42-20260116","doi-asserted-by":"crossref","first-page":"43","DOI":"10.1097\/00001648-199001000-00010","article-title":"No adjustments are needed for multiple comparisons","volume":"1","author":"Rothman","year":"1990","journal-title":"Epidemiology"},{"issue":"34","key":"R43-20260116","doi-asserted-by":"crossref","first-page":"e213","DOI":"10.3346\/jkms.2018.33.e213","article-title":"Real-world evidence versus randomized controlled trial: clinical research based on electronic medical records","volume":"33","author":"Kim","year":"2018","journal-title":"J Korean Med Sci"}],"container-title":["Journal of Wound, Ostomy &amp; Continence Nursing"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/WON.0000000000001249","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,1,16]],"date-time":"2026-01-16T05:01:37Z","timestamp":1768539697000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/WON.0000000000001249"}},"subtitle":["Findings From the Continence Care Registry, a Multinational, Observational, Longitudinal Study"],"short-title":[],"issued":{"date-parts":[[2026,1]]},"references-count":15,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2026]]}},"URL":"https:\/\/doi.org\/10.1097\/won.0000000000001249","relation":{},"ISSN":["1071-5754","1528-3976"],"issn-type":[{"value":"1071-5754","type":"print"},{"value":"1528-3976","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,1]]}}}