{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,14]],"date-time":"2026-04-14T22:30:05Z","timestamp":1776205805672,"version":"3.50.1"},"reference-count":24,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"8","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":["Menopause"],"published-print":{"date-parts":[[2024,8]]},"abstract":"<jats:title>Abstract<\/jats:title>\n          <jats:sec>\n            <jats:title>Objective<\/jats:title>\n            <jats:p>This study aimed to ascertain the accuracy of measure arterial stiffness using the HUAWEI GT 3 Pro smartwatch and pOpm\u00e8tre device against the SphygmoCor (algorithms: intersect tangent and maximum of the second derivate).<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods<\/jats:title>\n            <jats:p>Twenty-three physically active postmenopausal women (age: 58.9 \u00b1 3.2 years; body mass index: 26.3 \u00b1 4.8 kg\/m<jats:sup>2<\/jats:sup>) were recruited. Carotid-femoral pulse wave velocity, finger-toe pulse wave velocity, and wrist-finger pulse wave velocity were obtained using SphygmoCor, pOpm\u00e8tre and HUAWEI GT 3 Pro devices in a randomized order. Additionally, the pulse mean carotid-femoral and finger-toe pulse transit time was registered for SphygmoCor and pOpm\u00e8tre, respectively.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results<\/jats:title>\n            <jats:p>Lower values of pulse wave velocity were recorded by HUAWEI in comparison with SphygmoCor with both algorithms, whereas no significant differences were detected between SphygmoCor and pOpm\u00e8tre results. Pulse wave velocity values from SphygmoCor were positively correlated with pOpm\u00e8tre results (<jats:italic toggle=\"yes\">r<\/jats:italic> = 0.464 and <jats:italic toggle=\"yes\">r<\/jats:italic> = 0.451 using intersect tangent and second derivative algorithms), whereas this was not the case with those obtained from HUAWEI. Coefficients of bias of Lin's concordance coefficients close to 1 (0.832 and 0.831 for intersect tangent and second derivative algorithm, respectively) and mean bias close to 0 from Bland-Altman analysis suggested an acceptable agreement between pulse wave velocity obtained from SphygmoCor and pOpm\u00e8tre.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusions<\/jats:title>\n            <jats:p>Our results suggest an acceptable concordance of pulse wave velocity values recoded by SphygmoCor and pOpm\u00e8tre, whereas this was not the case for data obtained from HUAWEI GT 3 Pro smartwatch. Therefore, the pOpm\u00e8tre may be a viable alternative for assessing arterial stiffness, but measurement via the smartwatch device cannot be recommended.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/gme.0000000000002383","type":"journal-article","created":{"date-parts":[[2024,6,25]],"date-time":"2024-06-25T09:01:58Z","timestamp":1719306118000},"page":"709-715","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":2,"title":["Arterial stiffness assessment by pulse wave velocity in postmenopausal women: comparison between noninvasive devices"],"prefix":"10.1097","volume":"31","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-7988-968X","authenticated-orcid":false,"given":"Lucimere","family":"Bohn","sequence":"first","affiliation":[]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0520-3862","authenticated-orcid":false,"given":"Jessica","family":"Rial-V\u00e1zquez","sequence":"additional","affiliation":[]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3204-174X","authenticated-orcid":false,"given":"Iv\u00e1n","family":"Nine","sequence":"additional","affiliation":[{"name":"University of A Coruna, Performance and Health Group, Department of Physical Education and Sport, Faculty of Sports Sciences and Physical Education, A Coru\u00f1a"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2763-2847","authenticated-orcid":false,"given":"Mar\u00eda","family":"R\u00faa-Alonso","sequence":"additional","affiliation":[]},{"ORCID":"https:\/\/orcid.org\/0000-0001-5827-7510","authenticated-orcid":false,"given":"Juan","family":"Fari\u00f1as","sequence":"additional","affiliation":[{"name":"University of A Coruna, Performance and Health Group, Department of Physical Education and Sport, Faculty of Sports Sciences and Physical Education, A Coru\u00f1a"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3606-5933","authenticated-orcid":false,"given":"Manuel Avelino","family":"Gir\u00e1ldez-Garc\u00eda","sequence":"additional","affiliation":[{"name":"University of A Coruna, Performance and Health Group, Department of Physical Education and Sport, Faculty of Sports Sciences and Physical Education, A Coru\u00f1a"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-7571-9181","authenticated-orcid":false,"given":"Jorge","family":"Mota","sequence":"additional","affiliation":[{"name":"Research Center in Physical Activity, health and Leisure (CIAFEL)-Faculty of Sports-University of Porto (FADEUP) and Laboratory for Integrative and Translational Research in Population Health (ITR); University of Porto, Porto, Portugal"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1212-4188","authenticated-orcid":false,"given":"Eliseo","family":"Iglesias-Soler","sequence":"additional","affiliation":[{"name":"University of A Coruna, Performance and Health Group, Department of Physical Education and Sport, Faculty of Sports Sciences and Physical Education, A Coru\u00f1a"}]}],"member":"276","published-online":{"date-parts":[[2024,6,25]]},"reference":[{"key":"bib1-20250807","doi-asserted-by":"crossref","first-page":"389","DOI":"10.1055\/a-2003-9406","article-title":"Detrimental changes in health during menopause: The role of physical activity","volume":"44","year":"2023","journal-title":"Int J Sports Med"},{"key":"bib2-20250807","doi-asserted-by":"crossref","first-page":"636","DOI":"10.1016\/j.jacc.2013.09.063","article-title":"Aortic pulse wave velocity improves cardiovascular event prediction: An individual participant meta-analysis of prospective observational data from 17,635 subjects","volume":"63","year":"2014","journal-title":"J Am Coll Cardiol"},{"key":"bib3-20250807","doi-asserted-by":"crossref","first-page":"1318","DOI":"10.1016\/j.jacc.2009.10.061","article-title":"Prediction of cardiovascular events and all-cause mortality with arterial stiffness: A systematic review and meta-analysis","volume":"55","year":"2010","journal-title":"J Am Coll Cardiol"},{"key":"bib4-20250807","doi-asserted-by":"crossref","first-page":"388","DOI":"10.1161\/HYPERTENSIONAHA.109.133116","article-title":"Large and small artery cross-talk and recent morbidity-mortality trials in hypertension","volume":"54","year":"2009","journal-title":"Hypertension"},{"key":"bib5-20250807","doi-asserted-by":"crossref","first-page":"1281","DOI":"10.1097\/01.hjh.0000431740.32696.cc","article-title":"2013 ESH\/ESC guidelines for the management of arterial hypertension: The task force for the management of arterial hypertension of the European Society of Hypertension (ESH) and of the European Society of Cardiology (ESC)","volume":"31","year":"2013","journal-title":"J Hypertens"},{"key":"bib6-20250807","doi-asserted-by":"crossref","first-page":"1771","DOI":"10.1016\/j.jacc.2012.01.044","article-title":"Sex difference in cardiovascular risk: Role of pulse pressure amplification","volume":"59","year":"2012","journal-title":"J Am Coll Cardiol"},{"key":"bib7-20250807","doi-asserted-by":"crossref","first-page":"2588","DOI":"10.1093\/eurheartj\/ehl254","article-title":"Expert consensus document on arterial stiffness: Methodological issues and clinical applications","volume":"27","year":"2006","journal-title":"Eur Heart J"},{"key":"bib8-20250807","first-page":"669","article-title":"The noninvasive assessment of vascular aging","volume":"32","year":"2016","journal-title":"Can J Cardiol"},{"key":"bib9-20250807","doi-asserted-by":"crossref","first-page":"1618","DOI":"10.1097\/HJH.0000000000001371","article-title":"Evaluation of arterial stiffness by finger-toe pulse wave velocity: Optimization of signal processing and clinical validation","volume":"35","year":"2017","journal-title":"J Hypertens"},{"key":"bib10-20250807","doi-asserted-by":"crossref","first-page":"2338","DOI":"10.1093\/eurheartj\/ehq165","article-title":"Determinants of pulse wave velocity in healthy people and in the presence of cardiovascular risk factors: 'Establishing normal and reference values'","volume":"31","year":"2010","journal-title":"Eur Heart J"},{"key":"bib11-20250807","doi-asserted-by":"crossref","first-page":"1547","DOI":"10.1097\/HJH.0000000000002081","article-title":"Current assessment of pulse wave velocity: Comprehensive review of validation studies","volume":"37","year":"2019","journal-title":"J Hypertens"},{"key":"bib12-20250807","first-page":"189","article-title":"Regional and peripheral arterial stiffness measured by pOpmetre(R) in patients with cvx risk factor, link with carotid plaques","volume":"62","year":"2013","journal-title":"Ann Cardiol Angeiol (Paris)"},{"key":"bib13-20250807","doi-asserted-by":"crossref","first-page":"1582","DOI":"10.1016\/j.jacc.2020.01.046","article-title":"Wearable devices for ambulatory cardiac monitoring: JACC state-of-the-art review","volume":"75","year":"2020","journal-title":"J Am Coll Cardiol"},{"key":"bib14-20250807","doi-asserted-by":"crossref","first-page":"893557","DOI":"10.3389\/fcvm.2022.893557","article-title":"Accuracy evaluation of carotid-femoral pulse wave velocity estimated by smart terminal watch","volume":"9","year":"2022","journal-title":"Front Cardiovasc Med"},{"key":"bib15-20250807","doi-asserted-by":"crossref","first-page":"66","DOI":"10.1007\/s10389-006-0024-x","article-title":"Development of the world health organization Global Physical Activity Questionnaire (GPAQ)","volume":"14","year":"2006","journal-title":"J Public Health"},{"key":"bib16-20250807","doi-asserted-by":"crossref","first-page":"680195","DOI":"10.3389\/fnins.2021.680195","article-title":"Exaggerated exercise blood pressure as a marker of baroreflex dysfunction in normotensive metabolic syndrome patients","volume":"15","year":"2021","journal-title":"Front Neurosci"},{"key":"bib17-20250807","doi-asserted-by":"crossref","first-page":"291","DOI":"10.1111\/j.1542-474X.2004.93003.x","article-title":"Exercising testing in adult normal subjects and cardiac patients. 1963","volume":"9","year":"2004","journal-title":"Ann Noninvasive Electrocardiol"},{"key":"bib18-20250807","doi-asserted-by":"crossref","first-page":"314","DOI":"10.1136\/bjsm.31.4.314","article-title":"Assessing agreement between measurements recorded on a ratio scale in sports medicine and sports science","volume":"31","year":"1997","journal-title":"Br J Sports Med"},{"key":"bib19-20250807","doi-asserted-by":"crossref","first-page":"255","DOI":"10.2307\/2532051","article-title":"A concordance correlation coefficient to evaluate reproducibility","volume":"45","year":"1989","journal-title":"Biometrics"},{"key":"bib20-20250807","doi-asserted-by":"crossref","first-page":"227","DOI":"10.1016\/j.acvd.2014.12.003","article-title":"A novel device for measuring arterial stiffness using finger-toe pulse wave velocity: Validation study of the pOpmetre(R)","volume":"108","year":"2015","journal-title":"Arch Cardiovasc Dis"},{"key":"bib21-20250807","doi-asserted-by":"crossref","first-page":"3423","DOI":"10.1039\/C9TB02474C","article-title":"Wearable biochemical sensors for human health monitoring: Sensing materials and manufacturing technologies","volume":"8","year":"2020","journal-title":"J Mater Chem B"},{"key":"bib22-20250807","doi-asserted-by":"crossref","first-page":"8097","DOI":"10.1021\/acsnano.6b04344","article-title":"Nanopillar arrayed triboelectric nanogenerator as a self-powered sensitive sensor for a sleep monitoring system","volume":"10","year":"2016","journal-title":"ACS Nano"},{"key":"bib23-20250807","doi-asserted-by":"crossref","first-page":"e1702933","DOI":"10.1002\/smll.201702933","article-title":"Mechano-based transductive sensing for wearable healthcare","volume":"14","year":"2018","journal-title":"Small"},{"key":"bib24-20250807","doi-asserted-by":"crossref","first-page":"665","DOI":"10.1136\/heartjnl-2019-316004","article-title":"Accuracy of a smartwatch based single-lead electrocardiogram device in detection of atrial fibrillation","volume":"106","year":"2020","journal-title":"Heart"}],"container-title":["Menopause"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/GME.0000000000002383","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,8,7]],"date-time":"2025-08-07T14:06:09Z","timestamp":1754575569000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/GME.0000000000002383"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,6,25]]},"references-count":24,"journal-issue":{"issue":"8","published-print":{"date-parts":[[2024]]}},"URL":"https:\/\/doi.org\/10.1097\/gme.0000000000002383","relation":{},"ISSN":["1530-0374"],"issn-type":[{"value":"1530-0374","type":"print"}],"subject":[],"published":{"date-parts":[[2024,6,25]]}}}