{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,7]],"date-time":"2026-02-07T16:40:58Z","timestamp":1770482458703,"version":"3.49.0"},"reference-count":29,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"12","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2010,12]]},"DOI":"10.1097\/ico.0b013e3181d25ce2","type":"journal-article","created":{"date-parts":[[2010,9,16]],"date-time":"2010-09-16T11:25:49Z","timestamp":1284636349000},"page":"1359-1367","source":"Crossref","is-referenced-by-count":26,"title":["High-Resolution Spectral Domain Optical Coherence Tomography Technology for the Visualization of Contact Lens to Cornea Relationships"],"prefix":"10.1097","volume":"29","author":[{"given":"Jose M","family":"Gonzalez-Meijome","sequence":"first","affiliation":[]},{"given":"Alejandro","family":"Cervi\u00f1o","sequence":"additional","affiliation":[]},{"given":"Gonzalo","family":"Carracedo","sequence":"additional","affiliation":[]},{"given":"Antonio","family":"Queiros","sequence":"additional","affiliation":[]},{"given":"Santiago","family":"Garcia-L\u00e1zaro","sequence":"additional","affiliation":[]},{"given":"Teresa","family":"Ferrer-Blasco","sequence":"additional","affiliation":[]}],"member":"276","reference":[{"key":"R1-4-20210204","doi-asserted-by":"crossref","first-page":"499","DOI":"10.1046\/j.1475-1313.1995.9500096v.x","article-title":"The lacrimal lens as an assessment factor in hard contact lens fitting.","volume":"15","author":"Gowans","year":"1995","journal-title":"Ophthalmic Physiol Opt"},{"key":"R2-4-20210204","doi-asserted-by":"crossref","first-page":"589","DOI":"10.1097\/00006324-200108000-00011","article-title":"A comparison of two methods of evaluating cornea-to-contact lens base curve fluorescein patterns in keratoconus.","volume":"78","author":"Fink","year":"2001","journal-title":"Optom Vis Sci"},{"key":"R3-4-20210204","doi-asserted-by":"crossref","first-page":"E939","DOI":"10.1097\/OPX.0b013e3181886fb6","article-title":"Fluorescein pattern interpretation in keratoconus.","volume":"85","author":"Fink","year":"2008","journal-title":"Optom Vis Sci"},{"key":"R4-4-20210204","doi-asserted-by":"crossref","first-page":"33","DOI":"10.1111\/j.1444-0938.2005.tb06661.x","article-title":"Is fluorescein pattern analysis a valid method of assessing the accuracy of reverse geometry lenses for orthokeratology?","volume":"88","author":"Mountford","year":"2005","journal-title":"Clin Exp Optom"},{"key":"R5-4-20210204","doi-asserted-by":"crossref","first-page":"275","DOI":"10.1001\/archopht.1972.01000020277007","article-title":"A new fluorescent stain for soft hydrophilic lens fitting.","volume":"87","author":"Refojo","year":"1972","journal-title":"Arch Ophthalmol"},{"key":"R6-4-20210204","doi-asserted-by":"crossref","first-page":"633","DOI":"10.1097\/00006324-200210000-00008","article-title":"Effect of lens base curve on subjective comfort and assessment of fit with silicone hydrogel continuous wear contact lenses.","volume":"79","author":"Dumbleton","year":"2002","journal-title":"Optom Vis Sci"},{"key":"R7-4-20210204","doi-asserted-by":"crossref","first-page":"90","DOI":"10.3921\/joptom.2009.90","article-title":"Base curve influence on the fitting and comfort of the Senofilcon A contact lens.","volume":"2","author":"Gonzalez-Cavada","year":"2009","journal-title":"J Optom"},{"key":"R8-4-20210204","doi-asserted-by":"crossref","first-page":"874","DOI":"10.1097\/01.opx.0000249978.07340.b2","article-title":"Scalloped channels enhance tear mixing under hydrogel contact lenses.","volume":"83","author":"Lin","year":"2006","journal-title":"Optom Vis Sci"},{"key":"R9-4-20210204","doi-asserted-by":"crossref","first-page":"3043","DOI":"10.1167\/iovs.06-1372","article-title":"Measurement of corneal swelling variations without removal of the contact lens during extended wear.","volume":"48","author":"Martin","year":"2007","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"R10-4-20210204","doi-asserted-by":"crossref","first-page":"486","DOI":"10.3928\/1081-597X-20060501-11","article-title":"Corneal and epithelial thickness in keratoconus: a comparison of ultrasonic pachymetry, Orbscan II, and optical coherence tomography.","volume":"22","author":"Haque","year":"2006","journal-title":"J Refract Surg"},{"key":"R11-4-20210204","doi-asserted-by":"crossref","first-page":"117","DOI":"10.1016\/S1542-0124(12)70280-X","article-title":"Optical coherence tomography of the anterior segment.","volume":"6","author":"Simpson","year":"2008","journal-title":"Ocul Surf"},{"key":"R12-4-20210204","doi-asserted-by":"crossref","first-page":"315","DOI":"10.1016\/S0002-9394(01)01382-4","article-title":"The measurement of corneal epithelial thickness in response to hypoxia using optical coherence tomography.","volume":"133","author":"Wang","year":"2002","journal-title":"Am J Ophthalmol"},{"key":"R13-4-20210204","doi-asserted-by":"crossref","first-page":"127","DOI":"10.1111\/j.1475-1313.2006.00371.x","article-title":"Spectral optical coherence tomography: a new imaging technique in contact lens practice.","volume":"26","author":"Kaluzny","year":"2006","journal-title":"Ophthalmic Physiol Opt"},{"key":"R14-4-20210204","doi-asserted-by":"crossref","first-page":"1104","DOI":"10.1097\/OPX.0b013e31815b9e0e","article-title":"Spectral optical coherence tomography in video-rate and 3D imaging of contact lens wear.","volume":"84","author":"Kaluzny","year":"2007","journal-title":"Optom Vis Sci"},{"key":"R15-4-20210204","doi-asserted-by":"crossref","first-page":"44","DOI":"10.1097\/ICL.0b013e31819579f2","article-title":"In situ visualization of tears on contact lens using ultra high resolution optical coherence tomography.","volume":"35","author":"Wang","year":"2009","journal-title":"Eye Contact Lens"},{"key":"R17-4-20210204","doi-asserted-by":"crossref","first-page":"59","DOI":"10.1097\/01.opx.0000254633.32449.89","article-title":"Nomogram, corneal topography, and final prescription relations for corneal refractive therapy.","volume":"84","author":"Gonzalez-Meijome","year":"2007","journal-title":"Optom Vis Sci"},{"key":"R18-4-20210204","doi-asserted-by":"crossref","first-page":"311","DOI":"10.1097\/ICO.0b013e31818a7d80","article-title":"Short-term corneal response to corneal refractive therapy for different refractive targets.","volume":"28","author":"Villa-Collar","year":"2009","journal-title":"Cornea"},{"key":"R19-4-20210204","doi-asserted-by":"crossref","first-page":"e306","DOI":"10.1097\/OPX.0b013e3181989266","article-title":"Mechanism for corneal reshaping in hyperopic orthokeratology.","volume":"86","author":"Gifford","year":"2009","journal-title":"Optom Vis Sci"},{"key":"R20-4-20210204","doi-asserted-by":"crossref","first-page":"1165","DOI":"10.1097\/OPX.0b013e31818e8d13","article-title":"Time course of corneal topographic changes in the first week of overnight hyperopic orthokeratology.","volume":"85","author":"Gifford","year":"2008","journal-title":"Optom Vis Sci"},{"key":"R21-4-20210204","doi-asserted-by":"crossref","first-page":"4742","DOI":"10.1167\/iovs.03-0239","article-title":"Topographical thickness of the epithelium and total cornea after overnight wear of reverse-geometry rigid contact lenses for myopia reduction.","volume":"44","author":"Wang","year":"2003","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"R22-4-20210204","doi-asserted-by":"crossref","first-page":"3493","DOI":"10.1167\/iovs.04-0096","article-title":"Objective measurements of corneal light-backscatter during corneal swelling, by optical coherence tomography.","volume":"45","author":"Wang","year":"2004","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"R23-4-20210204","doi-asserted-by":"crossref","first-page":"189","DOI":"10.1097\/01.ICL.0000140223.60892.16","article-title":"Corneal and epithelial thickness changes after 4 weeks of overnight corneal refractive therapy lens wear, measured with optical coherence tomography.","volume":"30","author":"Haque","year":"2004","journal-title":"Eye Contact Lens"},{"key":"R24-4-20210204","doi-asserted-by":"crossref","first-page":"343","DOI":"10.1097\/OPX.0b013e318042af1d","article-title":"Corneal refractive therapy with different lens materials, part 1: corneal, stromal, and epithelial thickness changes.","volume":"84","author":"Haque","year":"2007","journal-title":"Optom Vis Sci"},{"key":"R25-4-20210204","doi-asserted-by":"crossref","first-page":"2524","DOI":"10.1167\/iovs.02-0731","article-title":"Precorneal and pre- and postlens tear film thickness measured indirectly with optical coherence tomography.","volume":"44","author":"Wang","year":"2003","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"R27-4-20210204","doi-asserted-by":"crossref","first-page":"150","DOI":"10.1016\/0275-5408(95)00103-4","article-title":"Determination of the total attenuation coefficient for six contact lens materials using the Beer-Lambert law.","volume":"16","author":"Hull","year":"1996","journal-title":"Ophthalmic Physiol Opt"},{"key":"R28-4-20210204","doi-asserted-by":"crossref","first-page":"475","DOI":"10.1046\/j.1475-1313.1999.00470.x","article-title":"The cornea swells in the posterior direction under hydrogel contact lenses.","volume":"19","author":"Erickson","year":"1999","journal-title":"Ophthalmic Physiol Opt"},{"key":"R29-4-20210204","doi-asserted-by":"crossref","first-page":"1070","DOI":"10.1167\/iovs.02-0343","article-title":"Topographical thickness of the epithelium and total cornea after hydrogel and PMMA contact lens wear with eye closure.","volume":"44","author":"Wang","year":"2003","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"R30-4-20210204","doi-asserted-by":"crossref","first-page":"184","DOI":"10.1002\/jbm.b.30583","article-title":"Equivalences between refractive index and equilibrium water content of conventional and silicone hydrogel soft contact lenses from automated and manual refractometry.","volume":"80","author":"Gonzalez-Meijome","year":"2007","journal-title":"J Biomed Mater Res B Appl Biomater"},{"key":"R31-4-20210204","doi-asserted-by":"crossref","first-page":"57","DOI":"10.1111\/j.1475-1313.2005.00342.x","article-title":"Refractive index and equilibrium water content of conventional and silicone hydrogel contact lenses.","volume":"26","author":"Gonzalez-Meijome","year":"2006","journal-title":"Ophthalmic Physiol Opt"}],"container-title":["Cornea"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/ICO.0b013e3181d25ce2","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,5,24]],"date-time":"2021-05-24T19:31:42Z","timestamp":1621884702000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/00003226-201012000-00004"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2010,12]]},"references-count":29,"journal-issue":{"issue":"12","published-print":{"date-parts":[[2010]]}},"URL":"https:\/\/doi.org\/10.1097\/ico.0b013e3181d25ce2","relation":{},"ISSN":["0277-3740"],"issn-type":[{"value":"0277-3740","type":"print"}],"subject":[],"published":{"date-parts":[[2010,12]]}}}