{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,8]],"date-time":"2026-04-08T08:08:13Z","timestamp":1775635693449,"version":"3.50.1"},"reference-count":38,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"5","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Cataract Refract Surg"],"published-print":{"date-parts":[[2020,5]]},"abstract":"<jats:sec>\n            <jats:title>Purpose:<\/jats:title>\n            <jats:p>To determine patient preoperative anatomical features and the parameters of implantable collamer lenses (ICLs) relevant in explaining vault variability.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Setting:<\/jats:title>\n            <jats:p>Ophthalmology Clinic Vista S\u00e1nchez Tranc\u00f3n, Badajoz, Spain.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Design:<\/jats:title>\n            <jats:p>Retrospective case series.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods:<\/jats:title>\n            <jats:p>This study comprised 360 eyes of 360 patients implanted with myopic or toric ICLs. Pentacam imaging was used for assessing white-to-white (WTW) diameter, central keratometry, and central corneal thickness. Anterior-segment optical coherence tomography was used to measure the horizontal anterior chamber angle distance (ATA), internal anterior chamber (ACQ), crystalline lens rise (CLR), anterior chamber angle (ACA), and vault. The sample was divided according to the implanted lens size (12.6 mm, 13.2 mm, and 13.7 mm). Vault predictors were identified from the variables above using multivariate regression analysis.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results:<\/jats:title>\n            <jats:p>The groups showed significant statistical differences for WTW, ATA, ACQ, ACA, and vault (<jats:italic toggle=\"yes\">P<\/jats:italic> &lt; .007 for all). In general, bigger lenses were implanted in eyes with larger transverse sizes (WTW and ATA) and deeper ACQ. Also, larger ICL diameters were associated with higher vaults. Multivariate regression analysis identified the lens size (13.2 mm as reference; 12.6 mm: \u03b2 [standardized coefficients] = \u22120.33; 13.7 mm: \u03b2 = 0.42), ATA (\u03b2 = \u22120.42), and CLR (\u03b2 = \u22120.25), ICL spherical equivalent (\u03b2 = \u22120.22) and patient age (\u03b2 = \u22120.12) as predictors of the vault size (adjusted-<jats:italic toggle=\"yes\">R<\/jats:italic>\n                                 <jats:sup>2<\/jats:sup> = 0.34 <jats:italic toggle=\"yes\">P<\/jats:italic> &lt; .001).<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusions:<\/jats:title>\n            <jats:p>The multivariate model explained 34% of vault variability. The predictors indicated the presence of different mechanisms regulating the vault. These involved the difference between the transverse size of the eye and the ICL, the crystalline lens protrusion, and the ICL properties, such as power and size.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/j.jcrs.0000000000000146","type":"journal-article","created":{"date-parts":[[2020,1,30]],"date-time":"2020-01-30T22:27:07Z","timestamp":1580423227000},"page":"728-736","source":"Crossref","is-referenced-by-count":70,"title":["Determining vault size in implantable collamer lenses: preoperative anatomy and lens parameters"],"prefix":"10.1097","volume":"46","author":[{"given":"Angel S\u00e1nchez","family":"Tranc\u00f3n","sequence":"first","affiliation":[]},{"given":"Santiago Cerpa","family":"Manito","sequence":"additional","affiliation":[]},{"given":"Oscar Torrado","family":"Sierra","sequence":"additional","affiliation":[]},{"given":"Ant\u00f3nio Manuel","family":"Baptista","sequence":"additional","affiliation":[]},{"given":"Pedro Miguel","family":"Serra","sequence":"additional","affiliation":[]}],"member":"276","reference":[{"key":"R1-20230819","doi-asserted-by":"crossref","first-page":"1683","DOI":"10.1016\/j.ophtha.2004.03.026","article-title":"United States Food and Drug Administration clinical trial of the Implantable Collamer Lens (ICL) for moderate to high myopia: three-year follow-up","volume":"111","author":"Sanders","year":"2004","journal-title":"Ophthalmology"},{"key":"R2-20230819","doi-asserted-by":"crossref","first-page":"1059","DOI":"10.2147\/OPTH.S111620","article-title":"Meta-analysis and review: effectiveness, safety, and central port design of the intraocular collamer lens","volume":"10","author":"Packer","year":"2016","journal-title":"Clin Ophthalmol"},{"key":"R3-20230819","doi-asserted-by":"crossref","first-page":"765","DOI":"10.3928\/1081597X-20110617-01","article-title":"Implantable collamer posterior chamber intraocular lenses: a review of potential complications","volume":"27","author":"Fernandes","year":"2011","journal-title":"J Refract Surg"},{"key":"R4-20230819","doi-asserted-by":"crossref","first-page":"30","DOI":"10.3928\/1081597X-20121210-02","article-title":"Comparison of postoperative vault height predictability using white-to-white or sulcus diameter-based sizing for the visian implantable collamer lens","volume":"29","author":"Reinstein","year":"2013","journal-title":"J Refract Surg"},{"key":"R5-20230819","article-title":"Outcomes of ICL and ICL sizing using Vumax","author":"Batlle","year":"2007","journal-title":"STAAR'S Visian ICL Expert Meet Dur ASCRS Annu Symp"},{"key":"R6-20230819","doi-asserted-by":"crossref","first-page":"272","DOI":"10.1016\/j.ophtha.2011.07.047","article-title":"Correlation between preoperative biometry and posterior chamber phakic Visian Implantable Collamer Lens vaulting","volume":"119","author":"Lee","year":"2012","journal-title":"Ophthalmology"},{"key":"R7-20230819","doi-asserted-by":"crossref","first-page":"260","DOI":"10.1186\/s12886-017-0663-4","article-title":"Buffering zone of implantable Collamer lens sizing in V4c","volume":"17","author":"Nam","year":"2017","journal-title":"BMC Ophthalmol"},{"key":"R9-20230819","doi-asserted-by":"crossref","first-page":"13","DOI":"10.1016\/j.jcrs.2010.07.014","article-title":"Improving accuracy of phakic intraocular lens sizing using high-frequency ultrasound biomicroscopy","volume":"37","author":"Dougherty","year":"2011","journal-title":"J Cataract Refract Surg"},{"key":"R10-20230819","doi-asserted-by":"crossref","first-page":"632","DOI":"10.1016\/j.ajo.2011.06.031","article-title":"Optimization of an implantable collamer lens sizing method using high-frequency ultrasound biomicroscopy","volume":"153","author":"Kojima","year":"2012","journal-title":"Am J Ophthalmol"},{"key":"R11-20230819","doi-asserted-by":"crossref","first-page":"1685","DOI":"10.1016\/j.ophtha.2006.12.018","article-title":"Direct measurement of the ciliary sulcus diameter by 35-megahertz ultrasound biomicroscopy","volume":"114","author":"Oh","year":"2007","journal-title":"Ophthalmology"},{"key":"R12-20230819","doi-asserted-by":"crossref","first-page":"185","DOI":"10.3928\/1081597X-20090201-03","article-title":"Correlation of anterior chamber angle and ciliary sulcus diameters with white-to-white corneal diameter in high myopes using artemis VHF digital ultrasound","volume":"25","author":"Reinstein","year":"2009","journal-title":"J Refract Surg"},{"key":"R13-20230819","doi-asserted-by":"crossref","first-page":"617","DOI":"10.1016\/j.jcrs.2009.11.017","article-title":"Relationship between ciliary sulcus diameter and anterior chamber diameter and corneal diameter","volume":"36","author":"Kawamorita","year":"2010","journal-title":"J Cataract Refract Surg"},{"key":"R14-20230819","doi-asserted-by":"crossref","first-page":"1862","DOI":"10.1016\/j.jcrs.2010.05.017","article-title":"Comparative analysis of white-to-white and angle-to-angle distance measurements with partial coherence interferometry and optical coherence tomography","volume":"36","author":"Nemeth","year":"2010","journal-title":"J Cataract Refract Surg"},{"key":"R15-20230819","doi-asserted-by":"crossref","first-page":"1011","DOI":"10.1016\/j.jcrs.2013.01.040","article-title":"Ciliary sulcus diameters at different anterior chamber depths in highly myopic eyes","volume":"39","author":"Gao","year":"2013","journal-title":"J Cataract Refract Surg"},{"key":"R16-20230819","doi-asserted-by":"crossref","first-page":"1686","DOI":"10.1016\/j.jcrs.2011.03.048","article-title":"Evaluation of ciliary sulcus diameter using ultrasound biomicroscopy in emmetropic eyes and myopic eyes","volume":"37","author":"Biermann","year":"2011","journal-title":"J Cataract Refract Surg"},{"key":"R17-20230819","doi-asserted-by":"crossref","first-page":"116","DOI":"10.1016\/j.ajo.2015.09.037","article-title":"Correcting interdevice bias of horizontal white-to-white and sulcus-to-sulcus measures used for implantable collamer lens sizing","volume":"161","author":"Guber","year":"2016","journal-title":"Am J Ophthalmol"},{"key":"R18-20230819","doi-asserted-by":"crossref","first-page":"238","DOI":"10.1016\/j.ophtha.2004.09.019","article-title":"Anterior chamber width measurement by high-speed optical coherence tomography","volume":"112","author":"Goldsmith","year":"2005","journal-title":"Ophthalmology"},{"key":"R19-20230819","doi-asserted-by":"crossref","first-page":"1099","DOI":"10.1016\/j.jcrs.2019.02.020","article-title":"Predictability of the vault after posterior chamber phakic intraocular lens implantation using anterior segment optical coherence tomography","volume":"45","author":"Igarashi","year":"2019","journal-title":"J Cataract Refract Surg"},{"key":"R20-20230819","doi-asserted-by":"crossref","first-page":"99","DOI":"10.1016\/j.ajo.2017.12.015","article-title":"Implantable collamer lens sizing method based on swept-source anterior segment optical coherence tomography","volume":"187","author":"Nakamura","year":"2018","journal-title":"Am J Ophthalmol"},{"key":"R21-20230819","doi-asserted-by":"crossref","first-page":"1506","DOI":"10.1016\/j.ophtha.2009.12.013","article-title":"Long-term changes in posterior chamber phakic intraocular collamer lens vaulting in myopic patients","volume":"117","author":"Schmidinger","year":"2010","journal-title":"Ophthalmology"},{"key":"R22-20230819","doi-asserted-by":"crossref","first-page":"519","DOI":"10.3928\/1081597X-20170602-02","article-title":"The effect of the crystalline lens on central vault after implantable collamer lens implantation","volume":"33","author":"Qi","year":"2017","journal-title":"J Refract Surg"},{"key":"R23-20230819","doi-asserted-by":"crossref","first-page":"177","DOI":"10.3928\/1081597X-20190204-01","article-title":"Determining the potential role of crystalline lens rise in vaulting in posterior chamber phakic collamer lens surgery for correction of myopia","volume":"35","author":"Gonzalez-Lopez","year":"2019","journal-title":"J Refract Surg"},{"key":"R24-20230819","doi-asserted-by":"crossref","first-page":"674","DOI":"10.1016\/j.jcrs.2004.09.034","article-title":"Pigment dispersion and Artisan phakic intraocular lenses: crystalline lens rise as a safety criterion","volume":"31","author":"Baikoff","year":"2005","journal-title":"J Cataract Refract Surg"},{"key":"R25-20230819","doi-asserted-by":"crossref","first-page":"1245","DOI":"10.1016\/j.ophtha.2009.10.033","article-title":"Vaulting of myopic and toric Implantable Collamer Lenses during accommodation measured with Visante optical coherence tomography","volume":"117","author":"Lindland","year":"2010","journal-title":"Ophthalmology"},{"key":"R26-20230819","doi-asserted-by":"crossref","first-page":"215","DOI":"10.1159\/000446185","article-title":"Preoperative biometric parameters predict the vault after ICL implantation: a retrospective clinical study","volume":"56","author":"Zheng","year":"2016","journal-title":"Ophthalmic Res"},{"key":"R27-20230819","doi-asserted-by":"crossref","first-page":"1616","DOI":"10.1016\/j.jcrs.2014.12.051","article-title":"Posterior chamber phakic intraocular lens sizing based on iris pigment layer measurements by anterior segment optical coherence tomography","volume":"41","author":"Malyugin","year":"2015","journal-title":"J Cataract Refract Surg"},{"key":"R28-20230819","doi-asserted-by":"crossref","first-page":"1809","DOI":"10.1016\/j.jcrs.2006.08.023","article-title":"Internal anterior chamber diameter using optical coherence tomography compared with white-to-white distances using automated measurements","volume":"32","author":"Kohnen","year":"2006","journal-title":"J Cataract Refract Surg"},{"key":"R29-20230819","doi-asserted-by":"crossref","first-page":"43","DOI":"10.1016\/j.ajo.2015.11.010","article-title":"Effects of implantable collamer lens V4c placement on iridocorneal angle measurements by Fourier-Domain optical coherence tomography","volume":"162","author":"Fernandez-Vigo","year":"2016","journal-title":"Am J Ophthalmol"},{"key":"R30-20230819","doi-asserted-by":"crossref","first-page":"544","DOI":"10.1136\/bjophthalmol-2017-310518","article-title":"Anterior segment optical coherence tomography angle and vault analysis after toric and non-toric implantable collamer lens V4c implantation in patients with high myopia","volume":"102","author":"Garcia-De la Rosa","year":"2018","journal-title":"Br J Ophthalmol"},{"key":"R31-20230819","doi-asserted-by":"crossref","first-page":"1803","DOI":"10.1001\/archopht.1980.01020040655013","article-title":"Volume and depth of the anterior chamber in the normal aging human eye","volume":"98","author":"Fontana","year":"1980","journal-title":"Arch Ophthalmol"},{"key":"R32-20230819","doi-asserted-by":"crossref","first-page":"346","DOI":"10.1364\/JOSAA.21.000346","article-title":"Scheimpflug and high-resolution magnetic resonance imaging of the anterior segment: a comparative study","volume":"21","author":"Koretz","year":"2004","journal-title":"J Opt Soc Am A Opt Image Sci Vis"},{"key":"R33-20230819","doi-asserted-by":"crossref","first-page":"216","DOI":"10.1093\/geronj\/5.3.216","article-title":"Age changes in pupil size","volume":"5","author":"Birren","year":"1950","journal-title":"J Gerontol"},{"key":"R34-20230819","first-page":"1132","article-title":"Factors affecting light-adapted pupil size in normal human subjects","volume":"35","author":"Winn","year":"1994","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"R35-20230819","doi-asserted-by":"crossref","first-page":"1199","DOI":"10.1016\/j.ajo.2014.08.020","article-title":"Dynamic vaulting changes in V4c versus V4 posterior chamber phakic lenses under differing lighting conditions","volume":"158","author":"Lee","year":"2014","journal-title":"Am J Ophthalmol"},{"key":"R36-20230819","doi-asserted-by":"crossref","first-page":"4","DOI":"10.1167\/tvst.7.3.4","article-title":"Dynamic assessment of light-induced vaulting changes of implantable collamer lens with central port by swept-source OCT: pilot study","volume":"7","author":"Gonzalez-Lopez","year":"2018","journal-title":"Transl Vis Sci Technol"},{"key":"R37-20230819","first-page":"58","article-title":"Comparison of anterior section parameters using anterior segment optical coherence tomography and ultrasound biomicroscopy in myopic patients after ICL implantation","volume":"9","author":"Zhang","year":"2016","journal-title":"Int J Ophthalmol"},{"key":"R38-20230819","doi-asserted-by":"crossref","first-page":"4060467","DOI":"10.1155\/2016\/4060467","article-title":"In Vivo positional analysis of implantable collamer lens using ultrasound biomicroscopy","volume":"2016","author":"Elshafei","year":"2016","journal-title":"J Ophthalmol"},{"key":"R39-20230819","doi-asserted-by":"crossref","first-page":"163","DOI":"10.1186\/s12886-018-0835-x","article-title":"Analysis of pre-operative factors affecting range of optimal vaulting after implantation of 12.6-mm V4c implantable collamer lens in myopic eyes","volume":"18","author":"Lee","year":"2018","journal-title":"BMC Ophthalmol"}],"container-title":["Journal of Cataract and Refractive Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/j.jcrs.0000000000000146","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,8,19]],"date-time":"2023-08-19T08:23:07Z","timestamp":1692433387000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/j.jcrs.0000000000000146"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,5]]},"references-count":38,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2020]]}},"URL":"https:\/\/doi.org\/10.1097\/j.jcrs.0000000000000146","relation":{},"ISSN":["0886-3350","1873-4502"],"issn-type":[{"value":"0886-3350","type":"print"},{"value":"1873-4502","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,5]]}}}