{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,11,13]],"date-time":"2025-11-13T18:26:31Z","timestamp":1763058391806},"reference-count":14,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"3","license":[{"start":{"date-parts":[[2020,5,1]],"date-time":"2020-05-01T00:00:00Z","timestamp":1588291200000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"abstract":"<jats:title>Abstract<\/jats:title>\n          <jats:sec>\n            <jats:title>Background:<\/jats:title>\n            <jats:p>Modifications in Jaffe serum creatinine (sCr) assays question the suitability of the results for direct comparison.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods:<\/jats:title>\n            <jats:p>sCr in adult in-patients was routinely measured either by SRM 909-standardized\/noncompensated (method A) or isotope dilution mass spectrometry traceable\/compensated method (reference). We converted values by method A into values by the reference using a formula provided by the manufacturer [Beckman Coulter (BC)] and traditional equating methods.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results:<\/jats:title>\n            <jats:p>The BC-based conversion and linear equating resulted in underestimated sCr values, whereas equipercentile equating (EE) provided sCr with not significantly different distribution from the reference values. Proportions of patients with renal impairment did not differ between the reference and EE-converted sCr, as opposed to BC-recalculated values. Three percent of patients were classified into better renal function category when applying BC versus EE conversion.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusions:<\/jats:title>\n            <jats:p>Equipercentile equation was a more accurate method for recalculation of sCr obtained from different Jaffe reaction assays than the linear equating or the BC linear formula. This study emphasizes the importance of the derivation sample specificity when applying research results to other real-world populations.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/j.pbj.0000000000000072","type":"journal-article","created":{"date-parts":[[2020,6,6]],"date-time":"2020-06-06T05:36:12Z","timestamp":1591421772000},"page":"e72","source":"Crossref","is-referenced-by-count":4,"title":["Conversion methods for modified Jaffe reaction assays of serum creatinine"],"prefix":"10.1097","volume":"5","author":[{"given":"Olga","family":"Laszczy\u0144ska","sequence":"first","affiliation":[{"name":"EPIUnit-Instituto de Sa\u00fade P\u00fablica, Universidade do Porto"}]},{"given":"Ana","family":"Azevedo","sequence":"additional","affiliation":[{"name":"EPIUnit-Instituto de Sa\u00fade P\u00fablica, Universidade do Porto"},{"name":"Departamento de Ci\u00eancias da Sa\u00fade P\u00fablica e Forenses e Educa\u00e7\u00e3o M\u00e9dica, Faculdade de Medicina da Universidade do Porto"},{"name":"Centro de Epidemiologia Hospitalar, Centro Hospitalar Universit\u00e1rio de S\u00e3o Jo\u00e3o"}]},{"given":"Manuel","family":"Ferreira-Almeida","sequence":"additional","affiliation":[{"name":"Servi\u00e7o de Patologia Cl\u00ednica, Centro Hospitalar Universit\u00e1rio de S\u00e3o Jo\u00e3o"}]},{"given":"Jo\u00e3o T.","family":"Guimar\u00e3es","sequence":"additional","affiliation":[{"name":"EPIUnit-Instituto de Sa\u00fade P\u00fablica, Universidade do Porto"},{"name":"Departamento de Ci\u00eancias da Sa\u00fade P\u00fablica e Forenses e Educa\u00e7\u00e3o M\u00e9dica, Faculdade de Medicina da Universidade do Porto"},{"name":"Departamento de Biomedicina, Faculdade de Medicina da Universidade do Porto, Porto, Portugal"}]},{"given":"Milton","family":"Severo","sequence":"additional","affiliation":[{"name":"EPIUnit-Instituto de Sa\u00fade P\u00fablica, Universidade do Porto"},{"name":"Departamento de Ci\u00eancias da Sa\u00fade P\u00fablica e Forenses e Educa\u00e7\u00e3o M\u00e9dica, Faculdade de Medicina da Universidade do Porto"}]}],"member":"276","published-online":{"date-parts":[[2020,5]]},"reference":[{"key":"R1-20231106","first-page":"1","article-title":"KDIGO 2012 clinical practice guideline for the evaluation and management of chronic kidney disease","volume":"3","year":"2012","journal-title":"Kidney Int."},{"key":"R2-20231106","doi-asserted-by":"crossref","first-page":"5","DOI":"10.1373\/clinchem.2005.0525144","article-title":"Recommendations for improving serum creatinine measurement: a report from the Laboratory Working Group of the National Kidney Disease Education Program","volume":"52","author":"Myers","year":"2006","journal-title":"Clin Chem."},{"key":"R3-20231106","doi-asserted-by":"crossref","first-page":"297","DOI":"10.5858\/2005-129-297-CMSOTA","article-title":"Creatinine measurement: state of the art in accuracy and interlaboratory harmonization","volume":"129","author":"Miller","year":"2005","journal-title":"Arch Pathol Lab Med."},{"key":"R4-20231106","doi-asserted-by":"crossref","first-page":"386","DOI":"10.1177\/0004563216664541","article-title":"Post-standardization of routine creatinine assays: are they suitable for clinical applications","volume":"54","author":"Jassam","year":"2017","journal-title":"Ann Clin Biochem."},{"key":"R5-20231106","doi-asserted-by":"crossref","first-page":"1987","DOI":"10.1515\/CCLM.2011.674","article-title":"Results of the recalibration of creatinine measurement with the modular Beckman Coulter Jaffe creatinine method","volume":"49","author":"Fillee","year":"2011","journal-title":"Clin Chem Lab Med."},{"key":"R6-20231106","doi-asserted-by":"crossref","first-page":"2054358117693353","DOI":"10.1177\/2054358117693353","article-title":"Creatinine assay attainment of analytical performance goals following implementation of IDMS standardization: further improvements required","volume":"4","author":"Lee","year":"2017","journal-title":"Can J Kidney Health Dis."},{"key":"R7-20231106","doi-asserted-by":"crossref","first-page":"838","DOI":"10.1515\/cclm-2018-0670","article-title":"Lower creatinine concentration values and lower inter-laboratory variation among Swedish hospital laboratories in 2014 compared to 1996: results from the Equalis external quality assessment program","volume":"57","author":"Helmersson-Karlqvist","year":"2019","journal-title":"Clin Chem Lab Med."},{"key":"R8-20231106","doi-asserted-by":"crossref","first-page":"391","DOI":"10.1373\/clinchem.2011.172288","article-title":"Specificity characteristics of 7 commercial creatinine measurement procedures by enzymatic and Jaffe method principles","volume":"58","author":"Greenberg","year":"2012","journal-title":"Clin Chem."},{"key":"R9-20231106","doi-asserted-by":"crossref","first-page":"604","DOI":"10.7326\/0003-4819-150-9-200905050-00006","article-title":"A new equation to estimate glomerular filtration rate","volume":"150","author":"Levey","year":"2009","journal-title":"Ann Intern Med."},{"key":"R10-20231106","doi-asserted-by":"crossref","first-page":"825","DOI":"10.7326\/0003-4819-158-11-201306040-00007","article-title":"Evaluation and management of chronic kidney disease: synopsis of the kidney disease: improving global outcomes 2012 clinical practice guideline","volume":"158","author":"Stevens","year":"2013","journal-title":"Ann Intern Med."},{"key":"R13-20231106","doi-asserted-by":"crossref","first-page":"21","DOI":"10.1186\/s12882-015-0012-x","article-title":"Routine serum creatinine measurements: how well do we perform?","volume":"16","author":"Hoste","year":"2015","journal-title":"BMC Nephrol."},{"key":"R14-20231106","doi-asserted-by":"crossref","first-page":"137","DOI":"10.1016\/j.cccn.2004.02.007","article-title":"Determination of reference intervals for serum creatinine, creatinine excretion and creatinine clearance with an enzymatic and a modified Jaffe method","volume":"344","author":"Junge","year":"2004","journal-title":"Clin Chim Acta."},{"key":"R15-20231106","doi-asserted-by":"crossref","first-page":"21","DOI":"10.1053\/j.ajkd.2007.04.004","article-title":"Impact of creatinine calibration on performance of GFR estimating equations in a pooled individual patient database","volume":"50","author":"Stevens","year":"2007","journal-title":"Am J Kidney Dis."},{"key":"R16-20231106","doi-asserted-by":"crossref","first-page":"737","DOI":"10.1515\/CCLM.2007.168","article-title":"Effects of analytic variations in creatinine measurements on the classification of renal disease using estimated glomerular filtration rate (eGFR)","volume":"45","author":"Klee","year":"2007","journal-title":"Clin Chem Lab Med."}],"container-title":["Porto Biomedical Journal"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/j.pbj.0000000000000072","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,11,6]],"date-time":"2023-11-06T02:04:44Z","timestamp":1699236284000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/j.pbj.0000000000000072"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,5]]},"references-count":14,"journal-issue":{"issue":"3","published-online":{"date-parts":[[2020]]}},"URL":"https:\/\/doi.org\/10.1097\/j.pbj.0000000000000072","relation":{},"ISSN":["2444-8664"],"issn-type":[{"type":"electronic","value":"2444-8664"}],"subject":[],"published":{"date-parts":[[2020,5]]}}}