{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,31]],"date-time":"2026-03-31T16:54:16Z","timestamp":1774976056248,"version":"3.50.1"},"reference-count":60,"publisher":"Wiley","issue":"12","license":[{"start":{"date-parts":[[2014,12,1]],"date-time":"2014-12-01T00:00:00Z","timestamp":1417392000000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"},{"start":{"date-parts":[[2014,12,1]],"date-time":"2014-12-01T00:00:00Z","timestamp":1417392000000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/doi.wiley.com\/10.1002\/tdm_license_1.1"}],"funder":[{"DOI":"10.13039\/501100004587","name":"Instituto de Salud Carlos III","doi-asserted-by":"publisher","award":["PI10\/01098"],"award-info":[{"award-number":["PI10\/01098"]}],"id":[{"id":"10.13039\/501100004587","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["OVS"],"published-print":{"date-parts":[[2014,12]]},"abstract":"<jats:title>ABSTRACT<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Purpose<\/jats:title>\n                    <jats:p>To examine the relationship between tear meniscus height (TMH) and subjective meniscus grading (subjective tear meniscus [TM]) with tear osmolarity.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>Tear osmolarity measurements (using TearLab) and digital images of the TM were obtained in 177 consecutive patients undergoing an eye examination at our optometry clinic (Universidad de Santiago de Compostela, Spain) who fulfilled the study's inclusion criteria. Participants were also administered the McMonnies and Ocular Surface Disease Index questionnaires for the detection of dry eye disease. The lower TM was videotaped by a digital camera attached to a slit lamp in its central portion without fluorescein instillation. After the study, a masked observer extracted an image from each video and measured the TMH using open source software (NIH ImageJ). Subsequently, the masked observer subjectively graded the appearance of each meniscus. For statistical analysis, subjects were stratified by age and by dry eye symptoms as indicated by their scores in the two questionnaires.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      In the whole study population, a significant relationship was observed between osmolarity and TMH (\n                      <jats:italic>r<\/jats:italic>\n                      = \u22120.41, p &lt; 0.001) and osmolarity and subjective TM (\n                      <jats:italic>r<\/jats:italic>\n                      = 0.35, p &lt; 0.001). A cluster analysis revealed similar correlations when subjects were stratified by age or dry eye symptoms, these correlations being more pronounced in older and more symptomatic subjects. Objective TMH measurements and subjective meniscus quality were also correlated (\n                      <jats:italic>r<\/jats:italic>\n                      = \u22120.75, p &lt; 0.001).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>Osmolarity and both objective TMH measurements and subjective interpretation of the meniscus showed high correlation, especially in older symptomatic subjects.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1097\/opx.0000000000000412","type":"journal-article","created":{"date-parts":[[2014,9,26]],"date-time":"2014-09-26T07:23:21Z","timestamp":1411716201000},"page":"1419-1429","source":"Crossref","is-referenced-by-count":22,"title":["Correlation between Tear Osmolarity and Tear Meniscus"],"prefix":"10.1002","volume":"91","author":[{"given":"Carlos","family":"Garc\u00eda\u2010Res\u00faa","sequence":"first","affiliation":[{"name":"Department of Applied Physics (Optometry Group GI\u20102092) University of Santiago de Compostela Santiago de Compostela Spain"}]},{"given":"Hugo","family":"Pena\u2010Verdeal","sequence":"additional","affiliation":[{"name":"Department of Applied Physics (Optometry Group GI\u20102092) University of Santiago de Compostela Santiago de Compostela Spain"}]},{"given":"Beatriz","family":"Remeseiro","sequence":"additional","affiliation":[{"name":"Departamento de Computaci\u00f3n Universidade da Coruna Campus de Elvi\u00f1a s\/n A Coru\u00f1a Spain"}]},{"given":"Maria J.","family":"Gir\u00e1ldez","sequence":"additional","affiliation":[{"name":"Department of Applied Physics (Optometry Group GI\u20102092) University of Santiago de Compostela Santiago de Compostela Spain"}]},{"given":"Eva","family":"Yebra\u2010Pimentel","sequence":"additional","affiliation":[{"name":"Department of Applied Physics (Optometry Group GI\u20102092) University of Santiago de Compostela Santiago de Compostela Spain"}]}],"member":"311","published-online":{"date-parts":[[2014,12,1]]},"reference":[{"key":"e_1_2_6_2_1","doi-asserted-by":"crossref","first-page":"317","DOI":"10.1111\/j.1475-1313.2012.00915.x","article-title":"Effects of tear hyperosmolarity on conjunctival cells in mild to moderate dry eye","volume":"32","author":"Julio G","year":"2012","journal-title":"Ophthalmic Physiol Opt"},{"key":"e_1_2_6_3_1","doi-asserted-by":"crossref","first-page":"293","DOI":"10.1016\/j.survophthal.2011.11.003","article-title":"Evaluation of dry eye","volume":"57","author":"McGinnigle S","year":"2012","journal-title":"Surv Ophthalmol"},{"key":"e_1_2_6_4_1","doi-asserted-by":"crossref","first-page":"792","DOI":"10.1016\/j.ajo.2010.10.032","article-title":"Tear osmolarity in the diagnosis and management of dry eye disease","volume":"151","author":"Lemp MA","year":"2011","journal-title":"Am J Ophthalmol"},{"key":"e_1_2_6_5_1","doi-asserted-by":"crossref","first-page":"75","DOI":"10.1016\/S1542-0124(12)70081-2","article-title":"The definition and classification of dry eye disease: report of the Definition and Classification Subcommittee of the International Dry Eye WorkShop (2007)","volume":"5","author":"Lemp M","year":"2007","journal-title":"Ocul Surf"},{"key":"e_1_2_6_6_1","doi-asserted-by":"crossref","first-page":"3","DOI":"10.1111\/j.1444-0938.2011.00634.x","article-title":"Osmolality and tear film dynamics","volume":"95","author":"Stahl U","year":"2012","journal-title":"Clin Exp Optom"},{"key":"e_1_2_6_7_1","doi-asserted-by":"crossref","first-page":"93","DOI":"10.1016\/S1542-0124(12)70082-4","article-title":"The epidemiology of dry eye disease: report of the Epidemiology Subcommittee of the International Dry Eye WorkShop (2007)","volume":"5","author":"Smith JA","year":"2007","journal-title":"Ocul Surf"},{"key":"e_1_2_6_8_1","doi-asserted-by":"crossref","first-page":"1102","DOI":"10.1016\/S0161-6420(03)00245-8","article-title":"Assessing the severity of keratitis sicca with videokeratoscopic indices","volume":"110","author":"Paiva CS","year":"2003","journal-title":"Ophthalmology"},{"key":"e_1_2_6_9_1","doi-asserted-by":"crossref","first-page":"38","DOI":"10.1097\/00003226-199801000-00007","article-title":"Evaluation of subjective assessments and objective diagnostic tests for diagnosing tear\u2010film disorders known to cause ocular irritation","volume":"17","author":"Pflugfelder SC","year":"1998","journal-title":"Cornea"},{"key":"e_1_2_6_10_1","first-page":"588","article-title":"Responses to a dry eye questionnaire from a normal population","volume":"58","author":"McMonnies CW","year":"1987","journal-title":"J Am Optom Assoc"},{"key":"e_1_2_6_11_1","doi-asserted-by":"crossref","first-page":"615","DOI":"10.1001\/archopht.118.5.615","article-title":"Reliability and validity of the Ocular Surface Disease Index","volume":"118","author":"Schiffman RM","year":"2000","journal-title":"Arch Ophthalmol"},{"key":"e_1_2_6_12_1","doi-asserted-by":"crossref","first-page":"483","DOI":"10.1097\/00003226-200007000-00016","article-title":"Survey of preferred tests for diagnosis of the tear film and dry eye","volume":"19","author":"Korb DR","year":"2000","journal-title":"Cornea"},{"key":"e_1_2_6_13_1","doi-asserted-by":"crossref","first-page":"61","DOI":"10.1016\/j.clae.2010.01.003","article-title":"Tear osmolarity measurement using the TearLab Osmolarity System in the assessment of dry eye treatment effectiveness","volume":"33","author":"Benelli U","year":"2010","journal-title":"Cont Lens Anterior Eye"},{"key":"e_1_2_6_14_1","doi-asserted-by":"crossref","first-page":"6125","DOI":"10.1167\/iovs.10-5390","article-title":"An objective approach to dry eye disease severity","volume":"51","author":"Sullivan BD","year":"2010","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"e_1_2_6_15_1","doi-asserted-by":"crossref","first-page":"108","DOI":"10.1016\/S1542-0124(12)70083-6","article-title":"Methodologies to diagnose and monitor dry eye disease: report of the Diagnostic Methodology Subcommittee of the International Dry Eye WorkShop (2007)","volume":"5","author":"Bron AJ","year":"2007","journal-title":"Ocul Surf"},{"key":"e_1_2_6_16_1","first-page":"374","article-title":"Physical chemistry of the normal and disordered tear film","volume":"104","author":"Holly FJ","year":"1985","journal-title":"Trans Ophthalmol Soc U K"},{"key":"e_1_2_6_17_1","doi-asserted-by":"crossref","first-page":"477","DOI":"10.1097\/00003226-200007000-00015","article-title":"Frequency of dry eye diagnostic test procedures used in various modes of ophthalmic practice","volume":"19","author":"Nichols KK","year":"2000","journal-title":"Cornea"},{"key":"e_1_2_6_18_1","doi-asserted-by":"crossref","first-page":"34","DOI":"10.3341\/kjo.1991.5.1.34","article-title":"Measurement of the tear meniscus height using 0.25% fluorescein sodium","volume":"5","author":"Lim KJ","year":"1991","journal-title":"Korean J Ophthalmol"},{"key":"e_1_2_6_19_1","first-page":"453","volume-title":"Contact Lens Practice","author":"Guillon JP","year":"1994"},{"key":"e_1_2_6_20_1","doi-asserted-by":"crossref","first-page":"487","DOI":"10.1111\/j.1475-1313.2009.00634.x","article-title":"Clinical assessment of the lower tear meniscus height","volume":"29","author":"Garcia\u2010Resua C","year":"2009","journal-title":"Ophthalmic Physiol Opt"},{"key":"e_1_2_6_21_1","doi-asserted-by":"crossref","first-page":"653","DOI":"10.3109\/02713689609008906","article-title":"Tear meniscus measurement in the diagnosis of dry eye","volume":"15","author":"Mainstone JC","year":"1996","journal-title":"Curr Eye Res"},{"key":"e_1_2_6_22_1","doi-asserted-by":"crossref","first-page":"169","DOI":"10.1016\/j.clae.2006.05.004","article-title":"Comparison between graticule and image capture assessment of lower tear film meniscus height","volume":"29","author":"Santodomingo\u2010Rubido J","year":"2006","journal-title":"Cont Lens Anterior Eye"},{"key":"e_1_2_6_23_1","doi-asserted-by":"crossref","first-page":"1030","DOI":"10.1097\/01.opx.0000192352.78935.e0","article-title":"The agreement and repeatability of tear meniscus height measurement methods","volume":"82","author":"Johnson ME","year":"2005","journal-title":"Optom Vis Sci"},{"key":"e_1_2_6_24_1","first-page":"142","article-title":"What does the phenol red thread test actually measure?","volume":"78","author":"Tomlinson A","year":"2001","journal-title":"Optom Vis Sci"},{"key":"e_1_2_6_25_1","doi-asserted-by":"crossref","first-page":"1082","DOI":"10.1001\/archopht.1979.01020010536004","article-title":"Schirmer test after topical anesthesia and the tear meniscus height in normal eyes","volume":"97","author":"Lamberts DW","year":"1979","journal-title":"Arch Ophthalmol"},{"key":"e_1_2_6_26_1","doi-asserted-by":"crossref","first-page":"132","DOI":"10.1097\/01.ICL.0000138714.96401.2b","article-title":"A comparison of tear volume (by tear meniscus height and phenol red thread test) and tear fluid osmolality measures in non\u2010lens wearers and in contact lens wearers","volume":"30","author":"Miller WL","year":"2004","journal-title":"Eye Contact Lens"},{"key":"e_1_2_6_27_1","doi-asserted-by":"crossref","first-page":"497","DOI":"10.1097\/00003226-200007000-00019","article-title":"The height and radius of the tear meniscus and methods for examining these parameters","volume":"19","author":"Oguz H","year":"2000","journal-title":"Cornea"},{"key":"e_1_2_6_28_1","doi-asserted-by":"crossref","first-page":"731","DOI":"10.1097\/01.opx.0000236810.17338.cf","article-title":"Tear meniscus height, lower punctum lacrimale, and the tear lipid layer in normal aging","volume":"83","author":"Patel S","year":"2006","journal-title":"Optom Vis Sci"},{"key":"e_1_2_6_29_1","first-page":"28","article-title":"Tear meniscus height in normal and dry eyes: evaluation using the Topcon IMAGEnet System","volume":"4124","author":"Kwong YM","year":"2001","journal-title":"Optom Today"},{"key":"e_1_2_6_30_1","doi-asserted-by":"crossref","first-page":"57","DOI":"10.1016\/S1367-0484(01)00005-4","article-title":"The tear (lacrimal) meniscus height in human eyes: a useful clinical measure or an unusable variable sign?","volume":"25","author":"Doughty MJ","year":"2002","journal-title":"Cont Lens Anterior Eye"},{"key":"e_1_2_6_31_1","doi-asserted-by":"crossref","first-page":"76","DOI":"10.1016\/0141-7037(90)80013-R","article-title":"The assessment of human tear flow","volume":"13","author":"Port MJA","year":"1990","journal-title":"J Br Contact Lens Assoc"},{"key":"e_1_2_6_32_1","doi-asserted-by":"crossref","first-page":"22","DOI":"10.1016\/j.clae.2012.10.074","article-title":"Comparison of subjective grading and objective assessment in meibography","volume":"36","author":"Pult H","year":"2013","journal-title":"Cont Lens Anterior Eye"},{"key":"e_1_2_6_33_1","doi-asserted-by":"crossref","first-page":"788","DOI":"10.1097\/OPX.0b013e318253de93","article-title":"Infrared imaging of meibomian gland structure using a novel keratograph","volume":"89","author":"Srinivasan S","year":"2012","journal-title":"Optom Vis Sci"},{"key":"e_1_2_6_34_1","doi-asserted-by":"crossref","first-page":"671","DOI":"10.1038\/nmeth.2089","article-title":"NIH Image to ImageJ: 25 years of image analysis","volume":"9","author":"Schneider CA","year":"2012","journal-title":"Nat Methods"},{"key":"e_1_2_6_35_1","volume-title":"8th Iberoamerican Optics Meeting and 11th Latin American Meeting on Optics, Lasers, and Applications","author":"Garc\u00eda\u2010Res\u00faa C","year":"2013"},{"key":"e_1_2_6_36_1","doi-asserted-by":"crossref","first-page":"126","DOI":"10.1016\/B978-0-7506-4196-8.50009-2","volume-title":"The Tear Film: Structure, Function and Clinical Examination","author":"Korb DR","year":"2002"},{"key":"e_1_2_6_37_1","doi-asserted-by":"crossref","first-page":"79","DOI":"10.1111\/j.1755-3768.1991.tb01997.x","article-title":"Tear film profile in dry eye","volume":"69","author":"Khurana AK","year":"1991","journal-title":"Acta Ophthalmol (Copenh)"},{"key":"e_1_2_6_38_1","doi-asserted-by":"crossref","first-page":"207","DOI":"10.1097\/00003226-199105000-00004","article-title":"Sjogren's syndrome and keratoconjunctivitis sicca","volume":"10","author":"Farris RL","year":"1991","journal-title":"Cornea"},{"key":"e_1_2_6_39_1","first-page":"23","article-title":"Diagnostic tests in keratoconjunctivitis sicca","volume":"9","author":"Farris RL","year":"1983","journal-title":"CLAO J"},{"key":"e_1_2_6_40_1","doi-asserted-by":"crossref","first-page":"4309","DOI":"10.1167\/iovs.05-1504","article-title":"Tear film osmolarity: determination of a referent for dry eye diagnosis","volume":"47","author":"Tomlinson A","year":"2006","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"e_1_2_6_41_1","doi-asserted-by":"crossref","first-page":"129","DOI":"10.1159\/000315026","article-title":"Hyperosmolarity of the tear film in dry eye syndrome","volume":"45","author":"Messmer EM","year":"2010","journal-title":"Dev Ophthalmol"},{"key":"e_1_2_6_42_1","doi-asserted-by":"crossref","first-page":"1036","DOI":"10.1097\/ICO.0b013e3181cd9a1d","article-title":"Comparison of human tear film osmolarity measured by electrical impedance and freezing point depression techniques","volume":"29","author":"Tomlinson A","year":"2010","journal-title":"Cornea"},{"key":"e_1_2_6_43_1","first-page":"221","article-title":"Report of the National Eye Institute\/Industry workshop on Clinical Trials in Dry Eyes","volume":"21","author":"Lemp MA","year":"1995","journal-title":"CLAO J"},{"key":"e_1_2_6_44_1","doi-asserted-by":"crossref","first-page":"677","DOI":"10.1097\/ICO.0b013e318198396b","article-title":"Evaluation of a new tear osmometer for repeatability and accuracy, using 0.5\u2010microL (500\u2010Nanoliter) samples","volume":"28","author":"Yildiz EH","year":"2009","journal-title":"Cornea"},{"key":"e_1_2_6_45_1","doi-asserted-by":"crossref","first-page":"553","DOI":"10.3109\/02713683.2010.484557","article-title":"Performance of tear osmolarity compared to previous diagnostic tests for dry eye diseases","volume":"35","author":"Versura P","year":"2010","journal-title":"Curr Eye Res"},{"key":"e_1_2_6_46_1","doi-asserted-by":"crossref","first-page":"66","DOI":"10.1136\/bjo.2007.131722","article-title":"Concordance between common dry eye diagnostic tests","volume":"93","author":"Moore JE","year":"2009","journal-title":"Br J Ophthalmol"},{"key":"e_1_2_6_47_1","doi-asserted-by":"crossref","first-page":"762","DOI":"10.1097\/01.ico.0000133997.07144.9e","article-title":"The lack of association between signs and symptoms in patients with dry eye disease","volume":"23","author":"Nichols KK","year":"2004","journal-title":"Cornea"},{"key":"e_1_2_6_48_1","first-page":"1186","article-title":"Statistical analysis of multi\u2010eye data in ophthalmic research","volume":"26","author":"Ray WA","year":"1985","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"e_1_2_6_49_1","doi-asserted-by":"crossref","first-page":"1041","DOI":"10.1185\/03007995.2011.566264","article-title":"Work productivity loss in patients with dry eye disease: an online survey","volume":"27","author":"Patel VD","year":"2011","journal-title":"Curr Med Res Opin"},{"key":"e_1_2_6_50_1","doi-asserted-by":"crossref","first-page":"835","DOI":"10.1007\/978-1-4615-5359-5_117","article-title":"Optimum dry eye classification using questionnaire responses","volume":"438","author":"McMonnies C","year":"1998","journal-title":"Adv Exp Med Biol"},{"key":"e_1_2_6_51_1","doi-asserted-by":"crossref","first-page":"5116","DOI":"10.1167\/iovs.03-0685","article-title":"Differences in clinical parameters and tear film of tolerant and intolerant contact lens wearers","volume":"44","author":"Glasson MJ","year":"2003","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"e_1_2_6_52_1","doi-asserted-by":"crossref","first-page":"94","DOI":"10.1001\/archophthalmol.2009.356","article-title":"Minimal clinically important difference for the ocular surface disease index","volume":"128","author":"Miller KL","year":"2010","journal-title":"Arch Ophthalmol"},{"key":"e_1_2_6_53_1","first-page":"512","article-title":"Key questions in a dry eye history","volume":"57","author":"McMonnies CW","year":"1986","journal-title":"J Am Optom Assoc"},{"key":"e_1_2_6_54_1","doi-asserted-by":"crossref","first-page":"542","DOI":"10.1007\/BF00448797","article-title":"Electrical conductivity of tear fluid in healthy persons and keratoconjunctivitis sicca patients measured by a flexible conductimetric sensor","volume":"234","author":"Ogasawara K","year":"1996","journal-title":"Graefes Arch Clin Exp Ophthalmol"},{"key":"e_1_2_6_55_1","volume-title":"Design and Analysis of Reliability Studies: The Statistical Evaluation of Measurement Errors","author":"Dunn G","year":"1989"},{"key":"e_1_2_6_56_1","doi-asserted-by":"crossref","first-page":"677","DOI":"10.1001\/archopht.1978.03910050373015","article-title":"Osmolarity of tear microvolumes in keratoconjunctivitis sicca","volume":"96","author":"Gilbard JP","year":"1978","journal-title":"Arch Ophthalmol"},{"key":"e_1_2_6_57_1","doi-asserted-by":"crossref","first-page":"399","DOI":"10.1016\/j.exer.2003.09.020","article-title":"Non\u2010invasive methods of assessing the tear film","volume":"78","author":"Yokoi N","year":"2004","journal-title":"Exp Eye Res"},{"key":"e_1_2_6_58_1","doi-asserted-by":"crossref","first-page":"516","DOI":"10.1097\/00003226-200308000-00006","article-title":"Is complete androgen insensitivity syndrome associated with alterations in the meibomian gland and ocular surface?","volume":"22","author":"Cermak JM","year":"2003","journal-title":"Cornea"},{"key":"e_1_2_6_59_1","doi-asserted-by":"crossref","first-page":"1250","DOI":"10.1097\/OPX.0b013e3181bb4225","article-title":"The perceived bulbar redness of clinical grading scales","volume":"86","author":"Schulze MM","year":"2009","journal-title":"Optom Vis Sci"},{"key":"e_1_2_6_60_1","doi-asserted-by":"crossref","first-page":"273","DOI":"10.1097\/OPX.0b013e3181981976","article-title":"Objective grading of the anterior eye","volume":"86","author":"Peterson RC","year":"2009","journal-title":"Optom Vis Sci"},{"key":"e_1_2_6_61_1","doi-asserted-by":"crossref","first-page":"79","DOI":"10.1038\/eye.2009.21","article-title":"Age\u2010 and gender\u2010related tear function changes in normal population","volume":"24","author":"Ozdemir M","year":"2010","journal-title":"Eye (Lond)"}],"container-title":["Optometry and Vision Science"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1097\/OPX.0000000000000412","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/full-xml\/10.1097\/OPX.0000000000000412","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1097\/OPX.0000000000000412","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,3,31]],"date-time":"2026-03-31T10:42:00Z","timestamp":1774953720000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1097\/OPX.0000000000000412"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2014,12]]},"references-count":60,"journal-issue":{"issue":"12","published-print":{"date-parts":[[2014,12]]}},"alternative-id":["10.1097\/OPX.0000000000000412"],"URL":"https:\/\/doi.org\/10.1097\/opx.0000000000000412","archive":["Portico"],"relation":{},"ISSN":["1040-5488","1538-9235"],"issn-type":[{"value":"1040-5488","type":"print"},{"value":"1538-9235","type":"electronic"}],"subject":[],"published":{"date-parts":[[2014,12]]}}}