{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,18]],"date-time":"2026-10-18T02:38:40Z","timestamp":1792291120795,"version":"4.4.0"},"reference-count":24,"publisher":"The Royal Society","issue":"4","license":[{"start":{"date-parts":[[2019,4,1]],"date-time":"2019-04-01T00:00:00Z","timestamp":1554076800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/royalsociety.org\/journals\/ethics-policies\/data-sharing-mining\/"}],"funder":[{"name":"National Institutes for food and drug Control, China","award":["2017X2"],"award-info":[{"award-number":["2017X2"]}]}],"content-domain":{"domain":["royalsocietypublishing.org"],"crossmark-restriction":true},"short-container-title":["R. Soc. open sci."],"published-print":{"date-parts":[[2019,4]]},"abstract":"<jats:p>A novel reference film was characterized to improve the oxygen gas transmission measurement accuracy of plastic materials for pharmaceutical packaging. The material processing, homogeneity, stability, jointly determined value and uncertainty evaluation were discussed. The film is the first reference film characterized by multiple laboratories using both manometric and coulometric methods. The oxygen transmission rate of the reference film was 20.53 with the expanded uncertainty of 1.36. The newly characterized reference film can be used in the calibration and self-calibration of oxygen transmission measurement equipment and analytical method verification to improve the measurement accuracy and achieve traceable data.<\/jats:p>","DOI":"10.1098\/rsos.190142","type":"journal-article","created":{"date-parts":[[2019,4,10]],"date-time":"2019-04-10T11:01:12Z","timestamp":1554894072000},"page":"190142","update-policy":"https:\/\/doi.org\/10.1098\/crossmark-policy","source":"Crossref","is-referenced-by-count":8,"title":["A new standard reference film for oxygen gas transmission measurements"],"prefix":"10.1098","volume":"6","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-4567-2268","authenticated-orcid":true,"given":"Lan-Gui","family":"Xie","sequence":"first","affiliation":[{"name":"The Institute for Packaging Materials and Pharmaceutical Excipients Control, National Institutes for food and drug Control, 2 Tiantan Xi Li, Beijing 100050, People's Republic of China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xia","family":"Zhao","sequence":"additional","affiliation":[{"name":"The Institute for Packaging Materials and Pharmaceutical Excipients Control, National Institutes for food and drug Control, 2 Tiantan Xi Li, Beijing 100050, People's Republic of China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Si-Hong","family":"Dou","sequence":"additional","affiliation":[{"name":"The Institute for Packaging Materials and Pharmaceutical Excipients Control, National Institutes for food and drug Control, 2 Tiantan Xi Li, Beijing 100050, People's Republic of China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Long","family":"Tang","sequence":"additional","affiliation":[{"name":"The Institute for Packaging Materials and Pharmaceutical Excipients Control, National Institutes for food and drug Control, 2 Tiantan Xi Li, Beijing 100050, People's Republic of China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-5010-3698","authenticated-orcid":true,"given":"Hui-Min","family":"Sun","sequence":"additional","affiliation":[{"name":"The Institute for Packaging Materials and Pharmaceutical Excipients Control, National Institutes for food and drug Control, 2 Tiantan Xi Li, Beijing 100050, People's Republic of China"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"175","published-online":{"date-parts":[[2019,4,10]]},"reference":[{"key":"e_1_3_6_2_2","first-page":"703","volume-title":"Advances in experimental medicine and biology","author":"Fennema O","year":"1991"},{"key":"e_1_3_6_3_2","doi-asserted-by":"publisher","DOI":"10.1002\/pts.621"},{"key":"e_1_3_6_4_2","doi-asserted-by":"publisher","DOI":"10.1063\/1.3116546"},{"key":"e_1_3_6_5_2","doi-asserted-by":"publisher","DOI":"10.1039\/C5NR07647A"},{"key":"e_1_3_6_6_2","doi-asserted-by":"publisher","DOI":"10.1007\/s12289-008-0329-0"},{"key":"e_1_3_6_7_2","doi-asserted-by":"publisher","DOI":"10.1007\/s10924-011-0285-5"},{"key":"e_1_3_6_8_2","volume-title":"Standard test method for determining gas permeability characteristics of plastic film and sheeting","author":"ASTM D1434-82","year":"2015"},{"key":"e_1_3_6_9_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0079-6700(00)00036-8"},{"key":"e_1_3_6_10_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0079-6700(01)00009-0"},{"key":"e_1_3_6_11_2","doi-asserted-by":"publisher","DOI":"10.1016\/0376-7388(95)00102-I"},{"key":"e_1_3_6_12_2","volume-title":"Standard test method for oxygen gas transmission rate through plastic film and sheeting using various sensors","author":"ASTM F2622-08","year":"2008"},{"key":"e_1_3_6_13_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1751-908X.2011.00120.x"},{"key":"e_1_3_6_14_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00216-015-8769-0"},{"key":"e_1_3_6_15_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.aca.2009.07.046"},{"key":"e_1_3_6_16_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.apradiso.2013.11.013"},{"key":"e_1_3_6_17_2","doi-asserted-by":"publisher","DOI":"10.1080\/02652030400028076"},{"key":"e_1_3_6_18_2","doi-asserted-by":"publisher","DOI":"10.1080\/02652030400023911"},{"key":"e_1_3_6_19_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jpba.2008.12.030"},{"key":"e_1_3_6_20_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jpba.2013.10.015"},{"key":"e_1_3_6_21_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00769-012-0940-0"},{"key":"e_1_3_6_22_2","volume-title":"Standard practice for sampling of plastics","author":"ASTM D 1898-68","year":"1989"},{"key":"e_1_3_6_23_2","volume-title":"Guide to the expression of uncertainty in measurement","author":"ISO\/IEC GUIDE 98-3","year":"2008"},{"key":"e_1_3_6_24_2","doi-asserted-by":"publisher","DOI":"10.1088\/0026-1394\/43\/4\/S06"},{"key":"e_1_3_6_25_2","first-page":"1","article-title":"SRM 1470: Polyester film for oxygen gas transmission measurements","volume":"260","author":"Barnes JD","year":"1979","journal-title":"NBS Special Publication"}],"container-title":["Royal Society Open Science"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/royalsocietypublishing.org\/doi\/pdf\/10.1098\/rsos.190142","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/royalsocietypublishing.org\/doi\/full-xml\/10.1098\/rsos.190142","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/royalsocietypublishing.org\/doi\/pdf\/10.1098\/rsos.190142","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,2,18]],"date-time":"2021-02-18T04:05:49Z","timestamp":1613621149000},"score":1,"resource":{"primary":{"URL":"https:\/\/royalsocietypublishing.org\/doi\/10.1098\/rsos.190142"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,4]]},"references-count":24,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2019,4]]}},"alternative-id":["10.1098\/rsos.190142"],"URL":"https:\/\/doi.org\/10.1098\/rsos.190142","relation":{},"ISSN":["2054-5703"],"issn-type":[{"value":"2054-5703","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,4]]},"assertion":[{"value":"2019-01-22","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2019-02-25","order":1,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2019-04-10","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}