{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"institution":[{"name":"bioRxiv"}],"indexed":{"date-parts":[[2026,7,21]],"date-time":"2026-07-21T08:23:57Z","timestamp":1784622237918,"version":"3.55.0"},"posted":{"date-parts":[[2024,9,13]]},"group-title":"Bioengineering","reference-count":54,"publisher":"openRxiv","license":[{"start":{"date-parts":[[2024,9,13]],"date-time":"2024-09-13T00:00:00Z","timestamp":1726185600000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"accepted":{"date-parts":[[2024,9,13]]},"abstract":"<jats:p>\n                  Successful tissue engineering requires biomedical devices that initially stabilize wounds, then degrade as tissue is regenerated. However, the material degradation rates reported in literature are often conflicting. Incorporation of in situ monitoring functionality into implanted devices would allow real time assessment of degradation and potential failure. This necessitates introduction of contrast agent as most biomedical devices are composed of polymeric materials with no inherent contrast in medical imaging modalities. In the present study, computed tomography (CT)-visible radiopaque composites were created by adding 5-20wt% tantalum oxide (TaO\n                  <jats:sub>x<\/jats:sub>\n                  ) nanoparticles into polymers with distinct degradation profiles: polycaprolactone (PCL), poly(lactide-co-glycolide) (PLGA) 85:15 and PLGA 50:50, representing slow, medium and fast degrading materials respectively. Radiopaque phantoms, mimicking porous tissue engineering devices, were implanted into mice intramuscularly or intraperitoneally, and monitored via CT over 20 weeks. Changes in phantom volume, including collapse and swelling, were visualized over time. Phantom degradation profile was determined by polymer matrix, regardless of nanoparticle addition and foreign body response was dictated by the implant site. In addition, degradation kinetics were significantly affected in mid-degrading materials, transitioning from linear degradation intramuscularly to exponential degradation intraperitoneally, due to differences in inflammatory responses and fluid flow. Nanoparticle excretion from degraded phantoms lagged behind polymer, and future studies will modulate nanoparticle clearance. Utilizing in situ monitoring, this study seeks to unify literature and facilitate better tissue engineering devices, by highlighting the relative effect of composition and implant site on important materials properties.\n                <\/jats:p>","DOI":"10.1101\/2024.09.09.612079","type":"posted-content","created":{"date-parts":[[2024,9,16]],"date-time":"2024-09-16T01:28:43Z","timestamp":1726450123000},"source":"Crossref","is-referenced-by-count":6,"title":["Material Composition and Implantation Site Affect in vivo Device Degradation Rate"],"prefix":"10.64898","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-2606-4136","authenticated-orcid":false,"given":"K. M.","family":"Pawelec","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"J. M.L.","family":"Hix","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"A.","family":"Troia","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"M.","family":"Kiupel","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"E. M.","family":"Shapiro","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"54368","reference":[{"key":"2024091801201107000_2024.09.09.612079v1.1","doi-asserted-by":"crossref","first-page":"16329","DOI":"10.1021\/acs.chemrev.2c00005","article-title":"Implants with sensing capabilities","volume":"122","year":"2022","journal-title":"Chemical Reviews"},{"key":"2024091801201107000_2024.09.09.612079v1.2","doi-asserted-by":"crossref","unstructured":"C. Gil , M. L. Tomov , A. S. Theus , A. Cetnar , M. Mahmoudi , and V. Serpooshan , \u201cIn vivo tracking of tissue engineered constructs,\u201d Micromachines 10, p. 474, 2019.","DOI":"10.3390\/mi10070474"},{"key":"2024091801201107000_2024.09.09.612079v1.3","doi-asserted-by":"publisher","DOI":"10.1002\/pi.1697"},{"key":"2024091801201107000_2024.09.09.612079v1.4","doi-asserted-by":"publisher","DOI":"10.1016\/S0142-9612(00)00047-8"},{"issue":"2","key":"2024091801201107000_2024.09.09.612079v1.5","doi-asserted-by":"crossref","first-page":"718","DOI":"10.1021\/acsbiomaterials.0c01439","article-title":"Design consideration to facilitate clinical radiological evaluation of implantable biomedical structures","volume":"7","year":"2021","journal-title":"ACS Biomaterials Science & Engineering"},{"key":"2024091801201107000_2024.09.09.612079v1.6","doi-asserted-by":"crossref","unstructured":"W. Wang , J. Liu , C. Li , J. Zhang , J. Liu , A. Dong , and D. Kong , \u201cReal-time and non-invasive fluorescence tracking of in vivo degradation of the thermosensitive pegylated polyester hydrogel,\u201d J. Mater. Chem. B 2, p. 4185, 2014.","DOI":"10.1039\/c4tb00275j"},{"key":"2024091801201107000_2024.09.09.612079v1.7","doi-asserted-by":"crossref","first-page":"45","DOI":"10.1016\/j.actbio.2017.02.045","article-title":"Shape memory polymers with enhanced visibility for magnetic resonance- and x-ray imaging modalities","volume":"54","year":"2017","journal-title":"Acta Biomaterialia"},{"key":"2024091801201107000_2024.09.09.612079v1.8","doi-asserted-by":"crossref","unstructured":"T. A. Finamore , T. E. Curtis , J. V. Tedesco , K. Grandfield , and R. K. Roeder , \u201cNondestructive, longitudinal measurement of collagen scaffold degradation using computed tomography and gold nanoparticles,\u201d Nanoscale 11, p. 4345, 2019.","DOI":"10.1039\/C9NR00313D"},{"key":"2024091801201107000_2024.09.09.612079v1.9","doi-asserted-by":"crossref","first-page":"129","DOI":"10.7150\/ntno.45354","article-title":"Multicolor spectral photon counting ct monitors and quantifies therapeutic cells and their encapsulating scaffold in a model of brain damage","volume":"4","year":"2020","journal-title":"Nanotheranostics"},{"key":"2024091801201107000_2024.09.09.612079v1.10","doi-asserted-by":"crossref","unstructured":"X. Chen , J. Zhang , K. Wu , X. Wu , J. Tang , S. Cui , D. Cao , R. Liu , C. Peng , L. Yu , and J. Ding , \u201cVisualizing the in vivo evolution of an injectiable and thermosensitive hydrogel using tri-modal bioimaging,\u201d Small 4, p. 2000310, 2020.","DOI":"10.1002\/smtd.202000310"},{"key":"2024091801201107000_2024.09.09.612079v1.11","doi-asserted-by":"crossref","unstructured":"K. M. Pawelec , T. A. Schoborg , and E. M. Shapiro , \u201cComputed tomography technologies to measure key structural features of polymeric biomedical implants from bench to bedside,\u201d J. Biomed. Mater. Res., pp. 1\u20139, 2024.","DOI":"10.1101\/2024.02.20.581229"},{"key":"2024091801201107000_2024.09.09.612079v1.12","doi-asserted-by":"crossref","unstructured":"T. Lex , B. R. Brummel , M. F. Attia , L. N. Giambalvo , K. G. Lee , B. A. Van Horn , D. C. Whitehead , and F. Alexis , \u201cIodinated polyesters with enhanced x-ray contrast properties for biomedical imaging,\u201d Scientific Reports 10, p. 1508, 2020.","DOI":"10.1038\/s41598-020-57720-5"},{"key":"2024091801201107000_2024.09.09.612079v1.13","doi-asserted-by":"crossref","first-page":"396","DOI":"10.1016\/j.actbio.2017.03.042","article-title":"Non-invasive monitoring of in vivo degradation of a radiopaque termoreversible hydrogel and its efficacy in preventing post-operative adhesions","volume":"55","year":"2017","journal-title":"Acta Biomaterialia"},{"key":"2024091801201107000_2024.09.09.612079v1.14","doi-asserted-by":"crossref","first-page":"4717","DOI":"10.1016\/j.bioactmat.2021.05.013","article-title":"Injectable and thermosensitive hydrogels mediating a universal macromolecular contrast agent with radiopacity for noninvasive imaging of deep tissues","volume":"6","year":"2021","journal-title":"Bioactive Materials"},{"key":"2024091801201107000_2024.09.09.612079v1.15","doi-asserted-by":"crossref","unstructured":"K. R. Sneha and G. S. Sailaja , \u201cIntrinsically radiopaque biomaterial assortments: a short review on the physical principles, x-ray imageability, and state-of-the-art developments,\u201d J. Mater. Chem. B 9, p. 8569, 2021.","DOI":"10.1039\/D1TB01513C"},{"key":"2024091801201107000_2024.09.09.612079v1.16","doi-asserted-by":"crossref","unstructured":"Y. C. Dong , M. Hajfathalian , P. S. N. Maidment , J. C. Hsu , P. C. Naha , S. Si-Mohamed , M. Breuilly , J. Kim , P. Chhour , P. Douek , H. I. Litt , and D. P. Cormode , \u201cEffect of gold nanoparticle size on their properties as contrast agents for computed tomography,\u201d Scientific Reports 9, p. 14912, 2019.","DOI":"10.1038\/s41598-019-50332-8"},{"key":"2024091801201107000_2024.09.09.612079v1.17","doi-asserted-by":"crossref","unstructured":"M. Delemeester , K. M. Pawelec , J. M. L. Hix , J. R. Siegenthaler , M. Lissy , P. C. Douek , A. Houmeau , S. A. Si-Mohamed , and E. M. Shapiro , \u201cDevice design and advanced computed tomography of 3D printed radiopaque composite scaffolds and meniscus,\u201d Advanced Functional Materials 2402404860, 2024.","DOI":"10.1002\/adfm.202404860"},{"issue":"3","key":"2024091801201107000_2024.09.09.612079v1.18","doi-asserted-by":"crossref","first-page":"723","DOI":"10.1148\/radiol.2015150577","article-title":"Ct image contrast of high-z elements: Phantom imaging studies and clinical implications","volume":"278","year":"2016","journal-title":"Radiology"},{"key":"2024091801201107000_2024.09.09.612079v1.19","doi-asserted-by":"publisher","DOI":"10.1039\/d0nr01234c"},{"issue":"1","key":"2024091801201107000_2024.09.09.612079v1.20","doi-asserted-by":"crossref","first-page":"103","DOI":"10.1148\/radiol.2018172381","article-title":"An intravascular tantalum oxide-based CT contrast agent: preclinical evaluation emulating overweight and obese patient size","volume":"289","year":"2018","journal-title":"Radiology"},{"key":"2024091801201107000_2024.09.09.612079v1.21","doi-asserted-by":"crossref","unstructured":"K. Pawelec , E. Tu , S. Chakravarty , J. Hix , L. Buchanan , L. Kenney , F. Buchanan , N. Chatterjee , S. Das , A. Alessio , and E. Shapiro , \u201cIncorporating tantalum oxide nanoparticles into implantable polymeric biomedical devices for radiological monitoring,\u201d Adv. Healthcare Mater. 2203167, 2023.","DOI":"10.1101\/2023.01.06.523025"},{"key":"2024091801201107000_2024.09.09.612079v1.22","doi-asserted-by":"crossref","unstructured":"X. Li , Q. Zou , J. Wei , and W. Li , \u201cThe degradation regulation of 3d printed scaffolds for promotion of osteogenesis and in vivo tracking,\u201d Composites Part B 222, p. 109084, 2021.","DOI":"10.1016\/j.compositesb.2021.109084"},{"key":"2024091801201107000_2024.09.09.612079v1.23","doi-asserted-by":"publisher","DOI":"10.1007\/s10856-007-3292-2"},{"key":"2024091801201107000_2024.09.09.612079v1.24","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.progpolymsci.2019.05.004","article-title":"Degradation mechanisms of polycaprolactone in the context of chemistry, geometry and environment","volume":"96","year":"2019","journal-title":"Progress in Polymer Science"},{"key":"2024091801201107000_2024.09.09.612079v1.25","doi-asserted-by":"crossref","unstructured":"K. M. Pawelec , J. Hix , and E. Shapiro , \u201cFunctional attachment of primary neurons and glia on radiopaque implantable biomaterials for nerve repair,\u201d Nanomedicine: Nanotechnology, Biology, and Medicine 52, p. 102692, 2023.","DOI":"10.1016\/j.nano.2023.102692"},{"key":"2024091801201107000_2024.09.09.612079v1.26","doi-asserted-by":"crossref","unstructured":"K. M. Pawelec , J. M. L. Hix , and E. M. Shapiro , \u201cMaterial matters: Degradation products affect regenerating Schwann cells,\u201d Biomaterials Advances 159, p. 213825, 2024.","DOI":"10.1016\/j.bioadv.2024.213825"},{"key":"2024091801201107000_2024.09.09.612079v1.27","doi-asserted-by":"crossref","first-page":"222","DOI":"10.1016\/j.actbio.2024.04.031","article-title":"In vivo micro- computed tomography evaluation of radiopaque, polymeric device degradation in normal and inflammatory environments","volume":"181","year":"2024","journal-title":"Acta Biomaterialia"},{"key":"2024091801201107000_2024.09.09.612079v1.28","doi-asserted-by":"publisher","DOI":"10.1016\/j.biomaterials.2004.01.038"},{"key":"2024091801201107000_2024.09.09.612079v1.29","doi-asserted-by":"crossref","unstructured":"A. N. Smith , J. B. Ulsh , R. Gupta , M. M. Tang , A. P. Peredo , T. D. Teinturier , R. L. Mauck , S. Gullbrand , and M. W. Hast , \u201cCharacterization of degradation kinetics of additively manufactured PLGA under variable mechanical loading paradigms,\u201d Journal of the Mechanical Beavior of Biomedical Materials 153, p. 106457, 2024.","DOI":"10.1016\/j.jmbbm.2024.106457"},{"key":"2024091801201107000_2024.09.09.612079v1.30","doi-asserted-by":"publisher","DOI":"10.1002\/jbm.820070107"},{"key":"2024091801201107000_2024.09.09.612079v1.31","doi-asserted-by":"publisher","DOI":"10.1038\/nmat3095"},{"key":"2024091801201107000_2024.09.09.612079v1.32","doi-asserted-by":"crossref","first-page":"396","DOI":"10.1016\/j.actbio.2017.03.042","article-title":"Non-invasive monitoring of in vivo degradation of a radiopaque thermoreversible hydrogel and its efficacy in preventing post-operative adhesions","volume":"55","year":"2017","journal-title":"Acta Biomaterialia"},{"key":"2024091801201107000_2024.09.09.612079v1.33","doi-asserted-by":"crossref","first-page":"94","DOI":"10.1016\/j.actbio.2015.03.021","article-title":"Non-invasive deep tissue imaging of iodine modified poly(caprolactone-co-1-4-oxepan-1,5-dione) using X-ray","volume":"20","year":"2015","journal-title":"Acta Biomaterialia"},{"key":"2024091801201107000_2024.09.09.612079v1.34","doi-asserted-by":"crossref","first-page":"10460","DOI":"10.1021\/acs.langmuir.0c01624","article-title":"How do surface properties of nanoparticles influence their diffusion in the extracellular matrix? a model study in matrigel using polymer-grafted nanoparticles","volume":"36","year":"2020","journal-title":"Langmuir"},{"key":"2024091801201107000_2024.09.09.612079v1.35","doi-asserted-by":"crossref","first-page":"315","DOI":"10.1002\/term.1688","article-title":"PEG hydrogel degradation and the role of the surrounding tissue environment","volume":"9","year":"2015","journal-title":"J. Tissue Eng. Regen. Med"},{"key":"2024091801201107000_2024.09.09.612079v1.36","doi-asserted-by":"crossref","unstructured":"A. Al Shoyaib , S. R. Archie , and V. T. Karamyan , \u201cIntraperitoneal route of drug administration: Should it be used in experimental animal studies?,\u201d Pharm. Res. 37, p. 12, 2020.","DOI":"10.1007\/s11095-019-2745-x"},{"key":"2024091801201107000_2024.09.09.612079v1.37","doi-asserted-by":"crossref","first-page":"322","DOI":"10.1016\/j.jconrel.2021.06.023","article-title":"Evaluating parameters affecting drug fate at the intramuscular injection site","volume":"336","year":"2021","journal-title":"Journal of Controlled Release"},{"key":"2024091801201107000_2024.09.09.612079v1.38","doi-asserted-by":"crossref","first-page":"1882","DOI":"10.1016\/j.polymdegradstab.2011.07.011","article-title":"Degradation kinetics of poly(lactic-co-glycolic) acid block copolymer cast films in phosphate buffer solution as revealed by infrared and Raman spectroscopies","volume":"96","year":"2011","journal-title":"Polymer Degradation and Stability"},{"key":"2024091801201107000_2024.09.09.612079v1.39","doi-asserted-by":"crossref","first-page":"506","DOI":"10.1007\/s12033-018-0084-5","article-title":"PCL-based composite scaffold matrices for tissue engineering applications","volume":"60","year":"2018","journal-title":"Molecular Biotechnology"},{"key":"2024091801201107000_2024.09.09.612079v1.40","doi-asserted-by":"crossref","first-page":"247","DOI":"10.1016\/j.addr.2016.04.015","article-title":"Poly(lactic acid)-based biomaterials for orthopaedic regenerative engineering","volume":"107","year":"2016","journal-title":"Advanced Drug Delivery Reviews"},{"key":"2024091801201107000_2024.09.09.612079v1.41","doi-asserted-by":"crossref","first-page":"499","DOI":"10.1007\/s11307-016-1026-x","article-title":"Dosimetry in micro-computed tomography: a review of the measurement methods, impacts, and characterization of the quantum gx","volume":"19","year":"2017","journal-title":"Mol Imaging Biol"},{"key":"2024091801201107000_2024.09.09.612079v1.42","doi-asserted-by":"crossref","unstructured":"N. Ziemkiewicz , G. Hilliard , N. A. Pullen , and K. Garg , \u201cThe role of innate and adaptive immune cells in skeletal muscle regeneration,\u201d International Journal of Molecular Sciences 22, p. 3265, 2021.","DOI":"10.3390\/ijms22063265"},{"key":"2024091801201107000_2024.09.09.612079v1.43","doi-asserted-by":"publisher","DOI":"10.1002\/term.5"},{"key":"2024091801201107000_2024.09.09.612079v1.44","doi-asserted-by":"crossref","first-page":"232","DOI":"10.1016\/j.msec.2019.03.091","article-title":"Tantalum nanoparticles reinforced polyetheretherketone shows enhanced bone formation","volume":"101","year":"2019","journal-title":"Materials Science and Engineering C"},{"key":"2024091801201107000_2024.09.09.612079v1.45","doi-asserted-by":"crossref","unstructured":"Y. Chen , Z. Luo , W. Meng , K. Liu , Q. Chen , Y. Cai , Z. Ding , C. Huang , Z. Zhou , M. Jiang , and L. Zhou , \u201cDecoding the \u201cfingerprint\u201d of implant materials: Insights into the foreign body reaction,\u201d Small 20, p. 10325, 2024.","DOI":"10.1002\/smll.202310325"},{"key":"2024091801201107000_2024.09.09.612079v1.46","doi-asserted-by":"publisher","DOI":"10.1016\/j.biomaterials.2004.01.066"},{"key":"2024091801201107000_2024.09.09.612079v1.47","doi-asserted-by":"crossref","unstructured":"C. Maduka , O. Habeeb , M. Kuhnert , M. Hakun , S. Goodman , and C. Contag , \u201cGlycolytic reprogramming underlies immune cell activation by polyethylene wear particles,\u201d Biomaterials Advances 152, p. 213495, 2023.","DOI":"10.1016\/j.bioadv.2023.213495"},{"key":"2024091801201107000_2024.09.09.612079v1.48","doi-asserted-by":"crossref","first-page":"100874","DOI":"10.1016\/j.mtla.2020.100874","article-title":"Radiopaque scaffolds based on electrospun iodixanol\/ polycaprolactone fibrous composites","volume":"14","year":"2020","journal-title":"Materialia"},{"key":"2024091801201107000_2024.09.09.612079v1.49","doi-asserted-by":"crossref","unstructured":"C. Yang , C. Zhao , S. Wang , X. and Mengchao , Y. Zhu , L. Jing , C. Wu , and J. Chang , \u201cStimulation of osteogenesis and angiogenesis by micro\/nano hierarchical hydroxyapatite via magrophage immunomodulation,\u201d Nanoscale 11, p. 17699, 2019.","DOI":"10.1039\/C9NR05730G"},{"issue":"6","key":"2024091801201107000_2024.09.09.612079v1.50","doi-asserted-by":"crossref","first-page":"673","DOI":"10.2217\/nnm.16.5","article-title":"The effect of nanoparticle size on in vivo pharmacokinetics and cellular interaction","volume":"11","year":"2016","journal-title":"Nanomedicine"},{"issue":"8","key":"2024091801201107000_2024.09.09.612079v1.51","doi-asserted-by":"crossref","first-page":"6650","DOI":"10.1021\/nn300928g","article-title":"Preclinical assessment of a zwitterionic tantalum oxide nanoparticle x-ray contrast agent","volume":"6","year":"2012","journal-title":"ACS Nano"},{"key":"2024091801201107000_2024.09.09.612079v1.52","doi-asserted-by":"crossref","unstructured":"A. B. Engin , D. Nikitovic , M. Neagu , P. Henrich-Noach , A. O. Docea , M. I. Shtilman , K. Golokhvast , A. M. Tsatsakis , \u201cMechanistic understanding of nanoparticles\u2019 interactions with extracellular matrix: the cell and immune system,\u201d Particle and Fibre Technology 14, p. 22, 2017.","DOI":"10.1186\/s12989-017-0199-z"},{"key":"2024091801201107000_2024.09.09.612079v1.53","doi-asserted-by":"publisher","DOI":"10.1109\/tsmc.1979.4310076"},{"key":"2024091801201107000_2024.09.09.612079v1.54","doi-asserted-by":"publisher","DOI":"10.1016\/j.neuroimage.2006.01.015"}],"container-title":[],"original-title":[],"link":[{"URL":"https:\/\/syndication.highwire.org\/content\/doi\/10.1101\/2024.09.09.612079","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,1,15]],"date-time":"2026-01-15T07:02:58Z","timestamp":1768460578000},"score":1,"resource":{"primary":{"URL":"http:\/\/biorxiv.org\/lookup\/doi\/10.1101\/2024.09.09.612079"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,9,13]]},"references-count":54,"URL":"https:\/\/doi.org\/10.1101\/2024.09.09.612079","relation":{},"subject":[],"published":{"date-parts":[[2024,9,13]]},"subtype":"preprint"}}