{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"institution":[{"name":"bioRxiv"}],"indexed":{"date-parts":[[2026,8,5]],"date-time":"2026-08-05T01:08:12Z","timestamp":1785892092561,"version":"3.56.0"},"posted":{"date-parts":[[2025,1,21]]},"group-title":"Bioengineering","reference-count":44,"publisher":"openRxiv","license":[{"start":{"date-parts":[[2025,1,21]],"date-time":"2025-01-21T00:00:00Z","timestamp":1737417600000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"accepted":{"date-parts":[[2025,1,21]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                <jats:p>\n                  Small diameter vascular grafts require a complex balance of biomechanical properties to achieve target burst pressure, arterial compliance-matching, and kink resistance to prevent failure. Iterative design of our multilayer vascular was previously used to achieve high compliance while retaining the requisite burst pressure and suture retention strength for clinical use. To impart kink resistance, a custom 3D solution printer was used to add a polymeric coil to the electrospun polyurethane graft to support the graft during bending. The addition of this reinforcing coil increased kink resistance but reduced compliance. A matrix of grafts were fabricated and tested to establish key structure-property relationships between coil parameters (spacing, diameter, modulus) and biomechanical properties (compliance, kink radius). A successful graft design was identified with a compliance similar to saphenous vein grafts (4.1 \u00b1 0.4 %\/mmHgx10\n                  <jats:sup>-2<\/jats:sup>\n                  ) while maintaining comparable kink resistance to grafts used currently in the clinic. To explore graft combinations that could increase graft compliance to match arterial values while retaining this kink resistance, we utilized finite element (FE) models of compliance and kink radius that simulated experimental testing. The FE-predicted graft compliance agreed well with experimental values. Although the kink model over-predicted the experimental kink radius values, key trends between graft parameters and kink resistance were reproduced. As an initial proof-of-concept, the validated models were then utilized to parse through a targeted graft design space. Although this initial parameter range tested did not yield a graft that improved upon the previous balance of graft properties, this combination of advanced manufacturing and computational framework paves the way for future model-driven design to further optimize graft performance.\n                <\/jats:p>\n                <jats:sec>\n                  <jats:title>TOC<\/jats:title>\n                  <jats:fig id=\"ufig1\" position=\"float\" orientation=\"portrait\" fig-type=\"figure\">\n                    <jats:graphic xmlns:xlink=\"http:\/\/www.w3.org\/1999\/xlink\" xlink:href=\"633374v1_ufig1\" position=\"float\" orientation=\"portrait\"\/>\n                  <\/jats:fig>\n                <\/jats:sec>","DOI":"10.1101\/2025.01.16.633374","type":"posted-content","created":{"date-parts":[[2025,1,21]],"date-time":"2025-01-21T12:30:43Z","timestamp":1737462643000},"source":"Crossref","is-referenced-by-count":1,"title":["Advanced Manufacturing of Coil-Reinforced Multilayer Vascular Grafts to Optimize Biomechanical Performance"],"prefix":"10.64898","author":[{"given":"Andrew","family":"Robinson","sequence":"first","affiliation":[{"name":"Department of Biomedical Engineering, The University of Texas at Austin, Austin, Texas, 78712, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"David","family":"Jiang","sequence":"additional","affiliation":[{"name":"Department of Biomedical Engineering, University of Utah, Salt Lake City, Utah, 84112, USA"},{"name":"Department of Biomedical Engineering, Texas A&M University, College Station, Texas, 77843, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Abbey","family":"Nkansah","sequence":"additional","affiliation":[{"name":"Department of Biomedical Engineering, The University of Texas at Austin, Austin, Texas, 78712, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Juan S.","family":"Herrera Duran","sequence":"additional","affiliation":[{"name":"Department of Biomedical Engineering, The University of Texas at Austin, Austin, Texas, 78712, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jonathan","family":"Leung","sequence":"additional","affiliation":[{"name":"Department of Biomedical Engineering, The University of Texas at Austin, Austin, Texas, 78712, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Madeline","family":"Laude","sequence":"additional","affiliation":[{"name":"Department of Biomedical Engineering, The University of Texas at Austin, Austin, Texas, 78712, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"John","family":"Craig","sequence":"additional","affiliation":[{"name":"Department of Biomedical Engineering, The University of Texas at Austin, Austin, Texas, 78712, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Leopold","family":"Guo","sequence":"additional","affiliation":[{"name":"Department of Biomedical Engineering, The University of Texas at Austin, Austin, Texas, 78712, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lucas","family":"Timmins","sequence":"additional","affiliation":[{"name":"Department of Biomedical Engineering, University of Utah, Salt Lake City, Utah, 84112, USA"},{"name":"Department of Biomedical Engineering, Texas A&M University, College Station, Texas, 77843, USA"},{"name":"Scientific Computing and Imaging Institute, University of Utah, Salt Lake City, Utah, 84112, USA"},{"name":"School of Engineering Medicine, Texas A&M University, Houston, Texas, 77030, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Elizabeth","family":"Cosgriff-Hernandez","sequence":"additional","affiliation":[{"name":"Department of Biomedical Engineering, The University of Texas at Austin, Austin, Texas, 78712, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"54368","reference":[{"key":"2026041022134962000_2025.01.16.633374v1.1","doi-asserted-by":"publisher","DOI":"10.1002\/mame.201400101"},{"key":"2026041022134962000_2025.01.16.633374v1.2","doi-asserted-by":"publisher","DOI":"10.1002\/jbm.b.33201"},{"key":"2026041022134962000_2025.01.16.633374v1.3","doi-asserted-by":"publisher","DOI":"10.1016\/j.actbio.2019.03.025"},{"issue":"1","key":"2026041022134962000_2025.01.16.633374v1.4","doi-asserted-by":"crossref","first-page":"100","DOI":"10.1002\/jbm.b.30710","article-title":"Addressing thrombogenicity in vascular graft construction","volume":"82B","year":"2007","journal-title":"Journal of Biomedical Materials Research Part B: Applied Biomaterials"},{"key":"2026041022134962000_2025.01.16.633374v1.5","doi-asserted-by":"publisher","DOI":"10.1177\/1538574411433299"},{"key":"2026041022134962000_2025.01.16.633374v1.6","doi-asserted-by":"publisher","DOI":"10.1016\/0021-9290(95)00028-3"},{"key":"2026041022134962000_2025.01.16.633374v1.7","doi-asserted-by":"publisher","DOI":"10.1039\/D0BM00226G"},{"key":"2026041022134962000_2025.01.16.633374v1.8","doi-asserted-by":"crossref","unstructured":"Motiwale S , Russell, M. , Conrad, O. , Carruth, J. , Wancura, M. , Robinson, A. , Cosgriff-Hernandez, E. , Sacks, M. Anisotropic Elastic Behavior of Hydrogel Coated Electrospun Polyurethane: Suitability for Heart Valve Leaflets. Journal of the mechanical behavior of biomedical materials. 2021.","DOI":"10.1016\/j.jmbbm.2021.104877"},{"key":"2026041022134962000_2025.01.16.633374v1.9","doi-asserted-by":"publisher","DOI":"10.1002\/jbm.a.37641"},{"key":"2026041022134962000_2025.01.16.633374v1.10","doi-asserted-by":"crossref","unstructured":"Wancura M , Nkansah A , Chwatko M , Robinson A , Fairley A , Cosgriff-Hernandez E . Interpenetrating network design of bioactive hydrogel coatings with enhanced damage resistance. Journal of Materials Chemistry B. 2023.","DOI":"10.1039\/D2TB02825E"},{"key":"2026041022134962000_2025.01.16.633374v1.11","doi-asserted-by":"publisher","DOI":"10.1039\/D0TB00055H"},{"key":"2026041022134962000_2025.01.16.633374v1.12","doi-asserted-by":"publisher","DOI":"10.1016\/j.actbio.2011.11.015"},{"key":"2026041022134962000_2025.01.16.633374v1.13","doi-asserted-by":"publisher","DOI":"10.1007\/s10439-018-02194-w"},{"issue":"3","key":"2026041022134962000_2025.01.16.633374v1.14","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1080\/00405168608688902","article-title":"Vascular grafts: Textile structures and their performance","volume":"15","year":"1986","journal-title":"Textile progress"},{"key":"2026041022134962000_2025.01.16.633374v1.15","doi-asserted-by":"publisher","DOI":"10.3389\/fmats.2020.00220"},{"key":"2026041022134962000_2025.01.16.633374v1.16","unstructured":"Li X. Development and Characterization of Kink-resistant Elastic Nanofibrous Vascular Graft with Antithrombosis Modification: University of California, Los Angeles; 2018."},{"key":"2026041022134962000_2025.01.16.633374v1.17","doi-asserted-by":"publisher","DOI":"10.1557\/s43578-021-00291-6"},{"key":"2026041022134962000_2025.01.16.633374v1.18","doi-asserted-by":"publisher","DOI":"10.1115\/1.4042902"},{"key":"2026041022134962000_2025.01.16.633374v1.19","doi-asserted-by":"crossref","unstructured":"Rovas G , Bikia V , Stergiopulos N . Design and computational optimization of compliance-matching aortic grafts. Frontiers in Bioengineering and Biotechnology. 2023;11.","DOI":"10.3389\/fbioe.2023.1179174"},{"key":"2026041022134962000_2025.01.16.633374v1.20","doi-asserted-by":"publisher","DOI":"10.1115\/1.4033178"},{"key":"2026041022134962000_2025.01.16.633374v1.21","doi-asserted-by":"crossref","unstructured":"Cosgriff-Hernandez E , Timmins LH . Model-Directed Design of Tissue Engineering Scaffolds. ACS Biomaterials Science & Engineering. 2022.","DOI":"10.1021\/acsbiomaterials.1c01386"},{"key":"2026041022134962000_2025.01.16.633374v1.22","doi-asserted-by":"crossref","unstructured":"Jiang D , Robinson AJ , Nkansah A , et al. A Computational Framework to Optimize the Mechanical Behavior of Synthetic Vascular Grafts. Journal of the Mechanical Behavior of Biomedical Materials. 2024\/12\/04\/ 2024:106847.","DOI":"10.1016\/j.jmbbm.2024.106847"},{"key":"2026041022134962000_2025.01.16.633374v1.23","doi-asserted-by":"publisher","DOI":"10.1016\/j.ab.2014.02.026"},{"key":"2026041022134962000_2025.01.16.633374v1.24","unstructured":"Standardization IOf. ISO 7198-2016. 2016."},{"key":"2026041022134962000_2025.01.16.633374v1.25","doi-asserted-by":"publisher","DOI":"10.1146\/annurev-bioeng-071516-044738"},{"key":"2026041022134962000_2025.01.16.633374v1.26","doi-asserted-by":"crossref","unstructured":"Maas SA , Ellis BJ , Ateshian GA , Weiss JA . FEBio: finite elements for biomechanics. 2012.","DOI":"10.1115\/1.4005694"},{"key":"2026041022134962000_2025.01.16.633374v1.27","doi-asserted-by":"crossref","unstructured":"Jiang D , Robinson AJ , Nkansah A , et al. A Computational Framework to Optimize the Mechanical Behavior of Synthetic Vascular Grafts. bioRxiv. 2024:2024.2009. 2005.608688.","DOI":"10.1101\/2024.09.05.608688"},{"key":"2026041022134962000_2025.01.16.633374v1.28","doi-asserted-by":"publisher","DOI":"10.21105\/joss.00506"},{"key":"2026041022134962000_2025.01.16.633374v1.29","doi-asserted-by":"publisher","DOI":"10.1016\/j.jmbbm.2020.104305"},{"key":"2026041022134962000_2025.01.16.633374v1.30","doi-asserted-by":"publisher","DOI":"10.1001\/archsurg.1980.01380100018004"},{"key":"2026041022134962000_2025.01.16.633374v1.31","doi-asserted-by":"publisher","DOI":"10.1016\/j.jvssci.2020.05.001"},{"key":"2026041022134962000_2025.01.16.633374v1.32","doi-asserted-by":"publisher","DOI":"10.1007\/s12055-018-0759-3"},{"key":"2026041022134962000_2025.01.16.633374v1.33","doi-asserted-by":"publisher","DOI":"10.1016\/j.biomaterials.2009.09.086"},{"issue":"1","key":"2026041022134962000_2025.01.16.633374v1.34","doi-asserted-by":"crossref","first-page":"65","DOI":"10.1002\/(SICI)1097-4636(199910)47:1<65::AID-JBM9>3.0.CO;2-F","article-title":"Compliance, elastic modulus, and burst pressure of small-intestine submucosa (SIS), small-diameter vascular grafts","volume":"47","year":"1999","journal-title":"Journal of Biomedical Materials Research: An Official Journal of The Society for Biomaterials, The Japanese Society for Biomaterials, and The Australian Society for Biomaterials and the Korean Society for Biomaterials"},{"key":"2026041022134962000_2025.01.16.633374v1.35","doi-asserted-by":"publisher","DOI":"10.1557\/s43578-021-00291-6"},{"key":"2026041022134962000_2025.01.16.633374v1.36","doi-asserted-by":"publisher","DOI":"10.1016\/j.colsurfb.2014.09.040"},{"key":"2026041022134962000_2025.01.16.633374v1.37","doi-asserted-by":"publisher","DOI":"10.5012\/bkC.2011.32.1.157"},{"key":"2026041022134962000_2025.01.16.633374v1.38","unstructured":"Ragaert K , De Baere I , Cardon L , Degrieck J . Bulk mechanical properties of thermoplastic poly-e-caprolactone. Paper presented at: 6th Polymers & Mould Innovations International Conference 2014."},{"key":"2026041022134962000_2025.01.16.633374v1.39","unstructured":"DSM-Firmenich. Bionate Thermoplastic Polycarbonate Polyurethane (PCU). 2020."},{"issue":"2","key":"2026041022134962000_2025.01.16.633374v1.40","first-page":"245","article-title":"Oxidative mechanisms of poly (carbonate urethane) and poly (ether urethane) biodegradation: in vivo and in vitro correlations","volume":"70","year":"2004","journal-title":"Journal of Biomedical Materials Research Part A: An Official Journal of The Society for Biomaterials, The Japanese Society for Biomaterials, and The Australian Society for Biomaterials and the Korean Society for Biomaterials"},{"key":"2026041022134962000_2025.01.16.633374v1.41","doi-asserted-by":"publisher","DOI":"10.1001\/jamacardio.2020.6585"},{"key":"2026041022134962000_2025.01.16.633374v1.42","doi-asserted-by":"publisher","DOI":"10.1016\/S0022-5223(19)38820-8"},{"key":"2026041022134962000_2025.01.16.633374v1.43","doi-asserted-by":"publisher","DOI":"10.1016\/j.biomaterials.2008.11.011"},{"key":"2026041022134962000_2025.01.16.633374v1.44","doi-asserted-by":"publisher","DOI":"10.1002\/cnm.3395"}],"container-title":[],"original-title":[],"link":[{"URL":"https:\/\/syndication.highwire.org\/content\/doi\/10.1101\/2025.01.16.633374","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,11]],"date-time":"2026-04-11T05:14:04Z","timestamp":1775884444000},"score":1,"resource":{"primary":{"URL":"http:\/\/biorxiv.org\/lookup\/doi\/10.1101\/2025.01.16.633374"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,1,21]]},"references-count":44,"URL":"https:\/\/doi.org\/10.1101\/2025.01.16.633374","relation":{},"subject":[],"published":{"date-parts":[[2025,1,21]]},"subtype":"preprint"}}