{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"institution":[{"name":"bioRxiv"}],"indexed":{"date-parts":[[2026,7,30]],"date-time":"2026-07-30T11:57:24Z","timestamp":1785412644624,"version":"3.56.0"},"posted":{"date-parts":[[2025,10,2]]},"group-title":"Neuroscience","reference-count":44,"publisher":"openRxiv","license":[{"start":{"date-parts":[[2025,10,2]],"date-time":"2025-10-02T00:00:00Z","timestamp":1759363200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"award":["R01AG063869"],"award-info":[{"award-number":["R01AG063869"]}],"id":[{"id":"https:\/\/ror.org\/049v75w11","id-type":"ROR","asserted-by":"publisher"}]},{"award":["RF1AG087306"],"award-info":[{"award-number":["RF1AG087306"]}],"id":[{"id":"https:\/\/ror.org\/049v75w11","id-type":"ROR","asserted-by":"publisher"}]},{"award":["R01AG091760"],"award-info":[{"award-number":["R01AG091760"]}],"id":[{"id":"https:\/\/ror.org\/049v75w11","id-type":"ROR","asserted-by":"publisher"}]},{"DOI":"10.13039\/100000070","name":"National Institute of Biomedical Imaging and Bioengineering","doi-asserted-by":"crossref","award":["P41EB029460"],"award-info":[{"award-number":["P41EB029460"]}],"id":[{"id":"10.13039\/100000070","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"accepted":{"date-parts":[[2025,10,2]]},"abstract":"<jats:title>ABSTRACT<\/jats:title>\n                <jats:sec>\n                  <jats:title>Background<\/jats:title>\n                  <jats:p>\n                    Advanced MR imaging techniques like steady state Nuclear Overhauser enhancement (ssNOE), transient NOE (tNOE), and myelin water fraction (MWF) provide a non-invasive way to assess the biochemical and structural integrity of brain tissue. Their sensitivity to endogenous lipids and macromolecules allows for the early detection of neuropathological changes, making them valuable tools in studying brain health and disease progression. In this study, we systematically evaluate the repeatability and sensitivity of NOE\n                    <jats:sub>MTR<\/jats:sub>\n                    , tNOE, and MWF for quantifying lipid and myelin content in the brains of wild-type (WT) mice, correlating the results with immunohistochemistry (IHC).\n                  <\/jats:p>\n                <\/jats:sec>\n                <jats:sec>\n                  <jats:title>Methods<\/jats:title>\n                  <jats:p>\n                    Five 6-month-old C57BL6\/J mice were imaged using 3D-NOE, and four mice underwent imaging with 2D tNOE and MWF across four repeated sessions using a 9.4T Scanner. For ssNOE imaging, CEST-weighted images at 56 frequency offsets were acquired using B\n                    <jats:sub>1rms<\/jats:sub>\n                    of 1.0 \u03bcT and 3s saturation duration. For tNOE, 52 offsets were acquired with a hyperbolic secant inversion pulse (bandwidth = 400Hz, duration = 44ms) and a mixing time of 200ms. For MWF, a multi-echo spin-echo (MESE) sequence was acquired with 40 evenly spaced echoes from 5.5ms to 200ms. For both ssNOE and tNOE, B\n                    <jats:sub>0<\/jats:sub>\n                    correction was performed using WASSR. Repeatability was quantified using intra- and inter-subject coefficients of variation (COV%). Pearson correlation was performed to see the association between imaging matrices and IHC measures, Luxol fast blue (LFB) stained sections, and myelin basic protein (MBP).\n                  <\/jats:p>\n                <\/jats:sec>\n                <jats:sec>\n                  <jats:title>Results<\/jats:title>\n                  <jats:p>\n                    All techniques demonstrated high repeatability across the whole brain (WB) and selected regions of interest (ROIs). Whole-brain intra-subject COV% for NOE\n                    <jats:sub>MTR<\/jats:sub>\n                    ranged from 1.92% to 3.40%, with corresponding inter-subject COVs of 1.50%. tNOE exhibited improved intra-subject repeatability with COVs ranging from 0.75% to 5.57%, but a reduced inter-subject COV of 2.97%. MWF imaging showed the highest stability overall, with an intra-subject COV ranging from 0.47% to 2.03% and an inter-subject COV of 0.75%. Visually, tNOE offers superior contrast in myelin-rich areas compared to NOE\n                    <jats:sub>MTR<\/jats:sub>\n                    and MWF imaging, showing greater sensitivity to myelinated regions. tNOE strongly correlates with histological markers: r = 0.83 with MBP staining and r = 0.72 with LFB staining (both p &lt; 0.001). MWF and NOE\n                    <jats:sub>MTR<\/jats:sub>\n                    showed correlations with MBP (r = 0.63 and r = 0.57, respectively).\n                  <\/jats:p>\n                <\/jats:sec>\n                <jats:sec>\n                  <jats:title>Conclusion<\/jats:title>\n                  <jats:p>\n                    NOE\n                    <jats:sub>MTR<\/jats:sub>\n                    , tNOE, and MWF imaging are reliable and repeatable methods for quantifying macromolecules in the brain. Among these, tNOE emerges as the most sensitive for detecting myelin lipids as confirmed by histological validation. These findings highlight the translational potential of tNOE for studying demyelinating disorders and neurodegenerative diseases.\n                  <\/jats:p>\n                <\/jats:sec>","DOI":"10.1101\/2025.09.30.679612","type":"posted-content","created":{"date-parts":[[2025,10,3]],"date-time":"2025-10-03T03:30:30Z","timestamp":1759462230000},"source":"Crossref","is-referenced-by-count":0,"title":["Multimodal MR Imaging for quantification of brain lipid in mice at 9.4T"],"prefix":"10.64898","author":[{"given":"Sunil Kumar","family":"Khokhar","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Anshuman","family":"Swain","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Narayan Datt","family":"Soni","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Halvor","family":"Juul","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Abeer","family":"Mathur","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dipak","family":"Roy","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Blake","family":"Benyard","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dushyant","family":"Kumar","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ravi Prakash Reddy","family":"Nanga","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mohammad","family":"Haris","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ravinder","family":"Reddy","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"54368","reference":[{"key":"2025100609150605000_2025.09.30.679612v1.1","doi-asserted-by":"crossref","unstructured":"Kister A , Kister I . Overview of myelin, major myelin lipids, and myelin-associated proteins. Front Chem. 2023 Feb 21;10:1041961.","DOI":"10.3389\/fchem.2022.1041961"},{"key":"2025100609150605000_2025.09.30.679612v1.2","doi-asserted-by":"publisher","DOI":"10.1038\/s41593-024-01749-6"},{"key":"2025100609150605000_2025.09.30.679612v1.3","doi-asserted-by":"crossref","unstructured":"Yoon JH , Seo Y , Jo YS , Lee S , Cho E , Cazenave-Gassiot A , et al. Brain lipidomics: From functional landscape to clinical significance. Sci Adv. 2022 Sept 16;8(37):eadc9317.","DOI":"10.1126\/sciadv.adc9317"},{"key":"2025100609150605000_2025.09.30.679612v1.4","doi-asserted-by":"crossref","unstructured":"4. Lee LE , Ljungberg E , Shin D , Figley CR , Vavasour IM , Rauscher A , et al. Inter-Vendor Reproducibility of Myelin Water Imaging Using a 3D Gradient and Spin Echo Sequence. Front Neurosci [Internet]. 2018 Nov 21 [cited 2025 June 3];12. Available from: https:\/\/www.frontiersin.org\/journals\/neuroscience\/articles\/10.3389\/fnins.2018.00854\/full","DOI":"10.3389\/fnins.2018.00854"},{"key":"2025100609150605000_2025.09.30.679612v1.5","doi-asserted-by":"crossref","unstructured":"Depp C , Sun T , Sasmita AO , Spieth L , Berghoff SA , Nazarenko T , et al. Myelin dysfunction drives amyloid-\u03b2 deposition in models of Alzheimer\u2019s disease. Nature. 2023 June;618(7964):349\u201357.","DOI":"10.1038\/s41586-023-06120-6"},{"issue":"7","key":"2025100609150605000_2025.09.30.679612v1.6","doi-asserted-by":"crossref","first-page":"e210259","DOI":"10.1212\/WNL.0000000000210259","article-title":"Neurodegeneration and Demyelination in the Multiple Sclerosis Spinal Cord","volume":"104","year":"2025","journal-title":"Neurology"},{"key":"2025100609150605000_2025.09.30.679612v1.7","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.29600"},{"key":"2025100609150605000_2025.09.30.679612v1.8","doi-asserted-by":"publisher","DOI":"10.1016\/j.neuroimage.2013.03.047"},{"issue":"4","key":"2025100609150605000_2025.09.30.679612v1.9","doi-asserted-by":"crossref","first-page":"1357","DOI":"10.1002\/mrm.29519","article-title":"Feasibility of transient nuclear Overhauser effect imaging in brain at 7 T","volume":"89","year":"2023","journal-title":"Magn Reson Med"},{"key":"2025100609150605000_2025.09.30.679612v1.10","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.22761"},{"key":"2025100609150605000_2025.09.30.679612v1.11","doi-asserted-by":"crossref","unstructured":"Jacobs PS , Swain A , Wilson N , Liu F , Benyard B , Spangler B , et al. Diffuse nuclear Overhauser effect MRI contrast changes detected in multiple sclerosis subjects at 7T. Brain Commun. 2025 Feb 1;7(1):fcaf043.","DOI":"10.1093\/braincomms\/fcaf043"},{"key":"2025100609150605000_2025.09.30.679612v1.12","doi-asserted-by":"crossref","unstructured":"Swain A , Soni ND , Wilson N , Juul H , Benyard B , Haris M , et al. Early-stage mapping of macromolecular content in APPNL-F mouse model of Alzheimer\u2019s disease using nuclear Overhauser effect MRI. Front Aging Neurosci. 2023;15:1266859.","DOI":"10.3389\/fnagi.2023.1266859"},{"key":"2025100609150605000_2025.09.30.679612v1.13","doi-asserted-by":"publisher","DOI":"10.1103\/PhysRev.92.411"},{"key":"2025100609150605000_2025.09.30.679612v1.14","doi-asserted-by":"publisher","DOI":"10.1016\/j.neuroimage.2013.03.047"},{"key":"2025100609150605000_2025.09.30.679612v1.15","doi-asserted-by":"publisher","DOI":"10.1002\/nbm.683"},{"key":"2025100609150605000_2025.09.30.679612v1.16","doi-asserted-by":"publisher","DOI":"10.1016\/j.neuroimage.2013.03.047"},{"key":"2025100609150605000_2025.09.30.679612v1.17","doi-asserted-by":"crossref","first-page":"144","DOI":"10.1016\/j.neuroimage.2018.06.026","article-title":"Chemical exchange saturation transfer MRI contrast in the human brain at 9.4 T","volume":"179","year":"2018","journal-title":"NeuroImage"},{"issue":"9","key":"2025100609150605000_2025.09.30.679612v1.18","doi-asserted-by":"crossref","first-page":"e4937","DOI":"10.1002\/nbm.4937","article-title":"Chemical exchange saturation transfer MRI detects myelin changes in cuprizone mouse model at 3T","volume":"36","year":"2023","journal-title":"NMR Biomed"},{"key":"2025100609150605000_2025.09.30.679612v1.19","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.1910310614"},{"issue":"3","key":"2025100609150605000_2025.09.30.679612v1.20","doi-asserted-by":"crossref","first-page":"1264","DOI":"10.1002\/mrm.28199","article-title":"Multi-spin echo T2 relaxation imaging with compressed sensing (METRICS) for rapid myelin water imaging","volume":"84","year":"2020","journal-title":"Magn Reson Med"},{"key":"2025100609150605000_2025.09.30.679612v1.21","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.1910370107"},{"key":"2025100609150605000_2025.09.30.679612v1.22","doi-asserted-by":"publisher","DOI":"10.1111\/jnc.16170"},{"key":"2025100609150605000_2025.09.30.679612v1.23","doi-asserted-by":"publisher","DOI":"10.1016\/j.neuroimage.2007.12.008"},{"issue":"10","key":"2025100609150605000_2025.09.30.679612v1.24","doi-asserted-by":"crossref","first-page":"7124","DOI":"10.1002\/alz.14190","article-title":"Detection of sex-specific glutamate changes in subregions of hippocampus in an early-stage Alzheimer\u2019s disease mouse model using GluCEST MRI","volume":"20","year":"2024","journal-title":"Alzheimers Dement"},{"issue":"1","key":"2025100609150605000_2025.09.30.679612v1.25","first-page":"126","article-title":"A fast, iterative, partial-fourier technique capable of local phase recovery","volume":"92","year":"1969","journal-title":"J Magn Reson"},{"key":"2025100609150605000_2025.09.30.679612v1.26","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.21873"},{"key":"2025100609150605000_2025.09.30.679612v1.27","doi-asserted-by":"crossref","unstructured":"27. Hsu LM , Wang S , Ranadive P , Ban W , Chao THH , Song S , et al. Automatic Skull Stripping of Rat and Mouse Brain MRI Data Using U-Net. Front Neurosci [Internet]. 2020 Oct 7 [cited 2025 Aug 26];14. Available from: https:\/\/www.frontiersin.org\/journals\/neuroscience\/articles\/10.3389\/fnins.2020.568614\/full","DOI":"10.3389\/fnins.2020.568614"},{"key":"2025100609150605000_2025.09.30.679612v1.28","doi-asserted-by":"publisher","DOI":"10.1016\/j.neuroimage.2006.01.015"},{"key":"2025100609150605000_2025.09.30.679612v1.29","doi-asserted-by":"publisher","DOI":"10.1016\/j.neuroimage.2008.03.037"},{"key":"2025100609150605000_2025.09.30.679612v1.30","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-021-87564-6"},{"issue":"1","key":"2025100609150605000_2025.09.30.679612v1.31","doi-asserted-by":"crossref","first-page":"73","DOI":"10.1186\/s12938-015-0064-y","article-title":"Histogram-based normalization technique on human brain magnetic resonance images from different acquisitions","volume":"14","year":"2015","journal-title":"Biomed Eng OnLine"},{"key":"2025100609150605000_2025.09.30.679612v1.32","doi-asserted-by":"crossref","unstructured":"Vercauteren T , Pennec X , Perchant A , Ayache N . Diffeomorphic demons: efficient non-parametric image registration. NeuroImage. 2009 Mar;45(1 Suppl):S61-72.","DOI":"10.1016\/j.neuroimage.2008.10.040"},{"key":"2025100609150605000_2025.09.30.679612v1.33","doi-asserted-by":"publisher","DOI":"10.1016\/j.neuroimage.2012.06.064"},{"key":"2025100609150605000_2025.09.30.679612v1.34","doi-asserted-by":"publisher","DOI":"10.1016\/j.jbiomech.2014.01.040"},{"key":"2025100609150605000_2025.09.30.679612v1.35","doi-asserted-by":"publisher","DOI":"10.1097\/00005072-199403000-00005"},{"issue":"5","key":"2025100609150605000_2025.09.30.679612v1.36","doi-asserted-by":"crossref","first-page":"e0323614","DOI":"10.1371\/journal.pone.0323614","article-title":"Validation of a data-driven multicomponent T2 analysis for quantifying myelin content in the cuprizone mouse model of multiple sclerosis","volume":"20","year":"2025","journal-title":"PLOS ONE"},{"issue":"1","key":"2025100609150605000_2025.09.30.679612v1.37","doi-asserted-by":"crossref","first-page":"11","DOI":"10.1002\/jmri.25838","article-title":"Clinical applications of chemical exchange saturation transfer (CEST) MRI","volume":"47","year":"2018","journal-title":"J Magn Reson Imaging"},{"key":"2025100609150605000_2025.09.30.679612v1.38","doi-asserted-by":"publisher","DOI":"10.1038\/nm.2615"},{"key":"2025100609150605000_2025.09.30.679612v1.39","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.24378"},{"key":"2025100609150605000_2025.09.30.679612v1.40","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.1910310614"},{"issue":"1","key":"2025100609150605000_2025.09.30.679612v1.41","doi-asserted-by":"crossref","first-page":"1369","DOI":"10.1038\/s41598-020-80585-7","article-title":"Comparison of multi echo T2 relaxation and steady state approaches for myelin imaging in the central nervous system","volume":"11","year":"2021","journal-title":"Sci Rep"},{"issue":"6","key":"2025100609150605000_2025.09.30.679612v1.42","doi-asserted-by":"crossref","first-page":"e4717","DOI":"10.1002\/nbm.4717","article-title":"7 tricks for 7 T CEST: Improving the reproducibility of multipool evaluation provides insights into the effects of age and the early stages of Parkinson\u2019s disease","volume":"36","year":"2023","journal-title":"NMR Biomed"},{"issue":"6","key":"2025100609150605000_2025.09.30.679612v1.43","doi-asserted-by":"crossref","first-page":"2449","DOI":"10.1002\/mrm.27221","article-title":"Rapid and quantitative chemical exchange saturation transfer (CEST) imaging with magnetic resonance fingerprinting (MRF)","volume":"80","year":"2018","journal-title":"Magn Reson Med"},{"issue":"2","key":"2025100609150605000_2025.09.30.679612v1.44","doi-asserted-by":"crossref","first-page":"779","DOI":"10.1002\/mrm.26141","article-title":"Accelerating chemical exchange saturation transfer (CEST) MRI by combining compressed sensing and sensitivity encoding techniques","volume":"77","year":"2017","journal-title":"Magn Reson Med"}],"container-title":[],"original-title":[],"link":[{"URL":"https:\/\/syndication.highwire.org\/content\/doi\/10.1101\/2025.09.30.679612","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,6,24]],"date-time":"2026-06-24T05:00:37Z","timestamp":1782277237000},"score":1,"resource":{"primary":{"URL":"http:\/\/biorxiv.org\/lookup\/doi\/10.1101\/2025.09.30.679612"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,10,2]]},"references-count":44,"URL":"https:\/\/doi.org\/10.1101\/2025.09.30.679612","relation":{"is-preprint-of":[{"id-type":"doi","id":"10.1186\/s12967-025-07476-1","asserted-by":"subject"}]},"subject":[],"published":{"date-parts":[[2025,10,2]]},"subtype":"preprint"}}