{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,8,2]],"date-time":"2025-08-02T17:42:28Z","timestamp":1754156548345,"version":"3.41.2"},"reference-count":20,"publisher":"Emerald","issue":"3","license":[{"start":{"date-parts":[[2014,8,5]],"date-time":"2014-08-05T00:00:00Z","timestamp":1407196800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.emerald.com\/insight\/site-policies"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2014,8,5]]},"abstract":"<jats:sec><jats:title content-type=\"abstract-heading\">Purpose<\/jats:title><jats:p>\u2013 The purpose of this paper is to propose a method to avoid hyperstaticity and eventually reduce the magnitude of undesired force\/torques. The authors also study the influence of hyperstaticity on human motor control during a redundant task.<\/jats:p><\/jats:sec><jats:sec><jats:title content-type=\"abstract-heading\">Design\/methodology\/approach<\/jats:title><jats:p>\u2013 Increasing the level of transparency of robotic interfaces is critical to haptic investigations and applications. This issue is particularly important to robotic structures that mimic the human counterpart's morphology and attach directly to the limb. Problems arise for complex joints such as the wrist, which cannot be accurately matched with a traditional mechanical joint. In such cases, mechanical differences between human and robotic joint cause hyperstaticity (i.e. over-constrained) which, coupled with kinematic misalignment, leads to uncontrolled force\/torque at the joint. This paper focusses on the prono-supination (PS) degree of freedom of the forearm. The overall force and torque in the wrist PS rotation is quantified by means of a wrist robot.<\/jats:p><\/jats:sec><jats:sec><jats:title content-type=\"abstract-heading\">Findings<\/jats:title><jats:p>\u2013 A practical solution to avoid hyperstaticity and reduce the level of undesired force\/torque in the wrist is presented. This technique is shown to reduce 75 percent of the force and 68 percent of the torque. It is also shown an over-constrained mechanism could alter human motor strategies.<\/jats:p><\/jats:sec><jats:sec><jats:title content-type=\"abstract-heading\">Practical implications<\/jats:title><jats:p>\u2013 The presented solution could be taken into account in the early phase of design of robots. It could also be applied to modify the fixation points of commercial robots in order to reduce the magnitude of reaction forces and avoid changes in motor strategy during the robotic therapy.<\/jats:p><\/jats:sec><jats:sec><jats:title content-type=\"abstract-heading\">Originality\/value<\/jats:title><jats:p>\u2013 In this paper for the first time the authors study the effect of hyperstaticity on both reaction forces and human motor strategies.<\/jats:p><\/jats:sec>","DOI":"10.1108\/ijicc-10-2013-0047","type":"journal-article","created":{"date-parts":[[2014,7,29]],"date-time":"2014-07-29T14:12:14Z","timestamp":1406643134000},"page":"289-306","source":"Crossref","is-referenced-by-count":0,"title":["Ergonomic design of a wrist robot"],"prefix":"10.1108","volume":"7","author":[{"given":"Mohammad","family":"Esmaeili","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Nathana\u00ebl","family":"Jarrass\u00e9","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Wayne","family":"Dailey","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Etienne","family":"Burdet","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Domenico","family":"Campolo","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"140","reference":[{"doi-asserted-by":"crossref","unstructured":"Beekhuis, J.H. , Westerveld, A.J. , van der Kooij, H. and Stienen, A.H.A. (2013), \u201cDesign of a self-aligning 3-DOF actuated exoskeleton for diagnosis and training of wrist and forearm after stroke\u201d, IEEE International Conference on Rehabilitation Robotics, ICORR, pp. 1-5.","key":"key2020122904311384900_b1","DOI":"10.1109\/ICORR.2013.6650357"},{"doi-asserted-by":"crossref","unstructured":"Campolo, D. , Formica, D. , Guglielmelli, E. and Keller, F. (2010), \u201cKinematic analysis of the human wrist during pointing tasks\u201d, Experimental Brain Research, Vol. 201 No. 3, pp. 561-573.","key":"key2020122904311384900_b2","DOI":"10.1007\/s00221-009-2073-1"},{"doi-asserted-by":"crossref","unstructured":"Campolo, D. , Widjaja, F. , Esmaeili, M. and Burdet, E. (2011), \u201cPointing with the wrist: a postural model for Donders\u2019 law\u201d, Experimental Brain Research, Vol. 212 No. 3, pp. 417-427.","key":"key2020122904311384900_b3","DOI":"10.1007\/s00221-011-2747-3"},{"doi-asserted-by":"crossref","unstructured":"Cempini, M. , De Rossi, S.M.M. , Lenzi, T. , Vitiello, N. and Carrozza, M.C. (2013), \u201cSelf-alignment mechanisms for assistive wearable robots: a kinetostatic compatibility method\u201d, IEEE Transactions on Robotics, Vol. 29 No. 1, pp. 236-250.","key":"key2020122904311384900_b4","DOI":"10.1109\/TRO.2012.2226381"},{"doi-asserted-by":"crossref","unstructured":"Esmaeili, M. , Dailey, W. , Burdet, E. and Campolo, D. (2013a), \u201cErgonomic design of a wrist exoskeleton and its effects on natural motor strategies during redundant tasks\u201d, IEEE International Conference on Robotics and Automation, ICRA, pp. 3370-3375.","key":"key2020122904311384900_b5","DOI":"10.1109\/ICRA.2013.6631047"},{"doi-asserted-by":"crossref","unstructured":"Esmaeili, M. , Jarrass\u00e9, N. , Dailey, W. , Burdet, E. and Campolo, D. (2013b), \u201cHyperstaticity for ergonomic design of a wrist exoskeleton\u201d, IEEE International Conference on Rehabilitation Robotics, ICORR, pp. 1-6.","key":"key2020122904311384900_b6","DOI":"10.1109\/ICORR.2013.6650417"},{"doi-asserted-by":"crossref","unstructured":"Hillman, M. (2004), \u201c2 rehabilitation robotics from past to present \u2013 a historical perspective\u201d, in Bien, Z. and Stefanov, D. (Eds), Advances in Rehabilitation Robotics, Chapter 2, Springer, Berlin and Heidelberg, pp. 25-44.","key":"key2020122904311384900_b7","DOI":"10.1007\/10946978_2"},{"doi-asserted-by":"crossref","unstructured":"Hogan, N. and Krebs, H.I. (2004), \u201cInteractive robots for neuro-rehabilitation\u201d, Restorative Neurology and Neuroscience, Vol. 22 No. 3, pp. 349-358.","key":"key2020122904311384900_b8","DOI":"10.3233\/RNN-2004-00277"},{"doi-asserted-by":"crossref","unstructured":"Jarrasse, N. and Morel, G. (2012), \u201cConnecting a human limb to an exoskeleton\u201d, IEEE Transactions on Robotics, Vol. 28 No. 3, pp. 697-709.","key":"key2020122904311384900_b9","DOI":"10.1109\/TRO.2011.2178151"},{"unstructured":"Kai, X. and Qiu, D. (2013), \u201cExperimental design verification of a compliant shoulder exoskeleton\u201d, IEEE International Conference on Robotics and Automation, ICRA, pp. 3894-3901.","key":"key2020122904311384900_b10"},{"doi-asserted-by":"crossref","unstructured":"Krebs, H.I. , Volpe, B.T. , Williams, D. , Celestino, J. , Charles, S.K. , Lynch, D. and Hogan, N. (2007), \u201cRobot-aided neurorehabilitation: a robot for wrist rehabilitation\u201d, IEEE Transactions on Neural Systems and Rehabilitation Engineering, Vol. 15 No. 3, pp. 327-335.","key":"key2020122904311384900_b11","DOI":"10.1109\/TNSRE.2007.903899"},{"doi-asserted-by":"crossref","unstructured":"Lugo-Villeda, L. , Frisoli, A. , Sandoval-Gonzalez, O. , Padilla, M. , Parra-Vega, V. , Avizzano, C. , Ruffaldi, E. and Bergamasco, M. (2009), \u201cHaptic guidance of Light-Exoskeleton for arm-rehabilitation tasks\u201d, The 18th IEEE International Symposium on Robot and Human Interactive Communication, RO-MAN, pp. 903-908.","key":"key2020122904311384900_b12","DOI":"10.1109\/ROMAN.2009.5326057"},{"doi-asserted-by":"crossref","unstructured":"Mayhew, D. , Bachrach, B. , Rymer, W.Z. and Beer, R.F. (2005), \u201cDevelopment of the MACARM \u2013 a novel cable robot for upper limb neurorehabilitation\u201d, IEEE, pp. 299-302.","key":"key2020122904311384900_b13","DOI":"10.1109\/ICORR.2005.1501106"},{"doi-asserted-by":"crossref","unstructured":"Oblak, J. , Cikajlo, I. and Matjacic, Z. (2010), \u201cUniversal haptic drive: a robot for arm and wrist rehabilitation\u201d, IEEE Transactions on Neural Systems and Rehabilitation Engineering, Vol. 18 No. 3, pp. 293-302.","key":"key2020122904311384900_b14","DOI":"10.1109\/TNSRE.2009.2034162"},{"doi-asserted-by":"crossref","unstructured":"Ren, Y. , Kang, S. , Park, H. , Wu, Y. and Zhang, L. (2012), \u201cDeveloping a multi-joint upper limb exoskeleton robot for diagnosis, therapy and outcome evaluation in neurorehabilitation\u201d, IEEE Transactions on Neural Systems and Rehabilitation Engineering, Vol. 21 No. 3, pp. 490-499.","key":"key2020122904311384900_b15","DOI":"10.1109\/TNSRE.2012.2225073"},{"doi-asserted-by":"crossref","unstructured":"Rosati, G. , Gallina, P. and Masiero, S. (2007), \u201cDesign, implementation and clinical tests of a wire-based robot for neurorehabilitation\u201d, IEEE Transactions on Neural Systems and Rehabilitation Engineering, Vol. 15 No. 4, pp. 560-569.","key":"key2020122904311384900_b16","DOI":"10.1109\/TNSRE.2007.908560"},{"doi-asserted-by":"crossref","unstructured":"Song, Z. and Guo, S. (2011), \u201cImplementation of self-rehabilitation for upper limb based on a haptic device and an exoskeleton device\u201d, International Conference on Mechatronics and Automation, ICMA, pp. 1911-1916.","key":"key2020122904311384900_b17","DOI":"10.1109\/ICMA.2011.5986272"},{"doi-asserted-by":"crossref","unstructured":"Tagliamonte, N.L. , Scorcia, M. , Formica, D. , Campolo, D. and Guglielmelli, E. (2011), \u201cEffects of impedance reduction of a robot for wrist rehabilitation on human motor strategies in healthy subjects during pointing tasks\u201d, Advanced Robotics, Vol. 25 No. 5, pp. 537-562.","key":"key2020122904311384900_b18","DOI":"10.1163\/016918611X558270"},{"doi-asserted-by":"crossref","unstructured":"Tagliamonte, N.L. , Sergi, F. , Carpino, G. , Accoto, D. and Guglielmelli, E. (2013), \u201cHuman-robot interaction tests on a novel robot for gait assistance\u201d, IEEE International Conference on Rehabilitation Robotics, ICORR, pp. 1-6.","key":"key2020122904311384900_b19","DOI":"10.1109\/ICORR.2013.6650387"},{"doi-asserted-by":"crossref","unstructured":"van Delden, A.L.E.Q. , Peper, C.L.E. , Kwakkel, G. and Beek, P.J. (2012), \u201cA systematic review of bilateral upper limb training devices for poststroke rehabilitation\u201d, Stroke Research and Treatment, Vol. 2012, pp. 1-17, doi: 10.1155\/2012\/972069.","key":"key2020122904311384900_b20","DOI":"10.1155\/2012\/972069"}],"container-title":["International Journal of Intelligent Computing and Cybernetics"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/www.emeraldinsight.com\/doi\/full-xml\/10.1108\/IJICC-10-2013-0047","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.emerald.com\/insight\/content\/doi\/10.1108\/IJICC-10-2013-0047\/full\/xml","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.emerald.com\/insight\/content\/doi\/10.1108\/IJICC-10-2013-0047\/full\/html","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,7,24]],"date-time":"2025-07-24T22:54:57Z","timestamp":1753397697000},"score":1,"resource":{"primary":{"URL":"http:\/\/www.emerald.com\/ijicc\/article\/7\/3\/289-306\/136745"}},"subtitle":["The influence of hyperstaticity on reaction forces and motor strategies"],"editor":[{"given":"Dr","family":"Guilherme N. DeSouza","sequence":"first","affiliation":[],"role":[{"role":"editor","vocabulary":"crossref"}]}],"short-title":[],"issued":{"date-parts":[[2014,8,5]]},"references-count":20,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2014,8,5]]}},"alternative-id":["10.1108\/IJICC-10-2013-0047"],"URL":"https:\/\/doi.org\/10.1108\/ijicc-10-2013-0047","relation":{},"ISSN":["1756-378X"],"issn-type":[{"type":"print","value":"1756-378X"}],"subject":[],"published":{"date-parts":[[2014,8,5]]}}}