{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,10]],"date-time":"2025-10-10T12:58:14Z","timestamp":1760101094690,"version":"3.41.2"},"reference-count":21,"publisher":"Emerald","issue":"6","license":[{"start":{"date-parts":[[2018,10,30]],"date-time":"2018-10-30T00:00:00Z","timestamp":1540857600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.emerald.com\/insight\/site-policies"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["IR"],"published-print":{"date-parts":[[2018,12,7]]},"abstract":"<jats:sec>\n<jats:title content-type=\"abstract-subheading\">Purpose<\/jats:title>\n<jats:p>The purpose of this study is the presentation and research of a simple and rapid calibration methodology for industrial robot. Extensive research efforts were devoted to meet the requirements of online compensation, closed-loop feedback control and high-precision machining during the flexible machining process of robot for large-scale cabin.<\/jats:p>\n<\/jats:sec>\n<jats:sec>\n<jats:title content-type=\"abstract-subheading\">Design\/methodology\/approach<\/jats:title>\n<jats:p>A simple and rapid method to design and construct the transformation relation between the base coordinate system of robot and the measurement coordinate system was proposed based on geometric constraint. By establishing the Denavit\u2013Hartenberg model for robot calibration, a method of two-step error for kinematic parameters calibration was put forward, which aided in achievement of step-by-step calibration of angle and distance errors. Furthermore, KUKA robot was considered as the research object, and related experiments were performed based on laser tracker.<\/jats:p>\n<\/jats:sec>\n<jats:sec>\n<jats:title content-type=\"abstract-subheading\">Findings<\/jats:title>\n<jats:p>The experimental results demonstrated that the accuracy of the coordinate transformation could reach 0.128 mm, which meets the transformation requirements. Compared to other methods used in this study, the calibration method of two-step error could significantly improve the positioning accuracy of robot up to 0.271 mm.<\/jats:p>\n<\/jats:sec>\n<jats:sec>\n<jats:title content-type=\"abstract-subheading\">Originality\/value<\/jats:title>\n<jats:p>The methodology based on geometric constraint and two-step error is simple and can rapidly calibrate the kinematic parameters of robot. It also leads to the improvement in the positioning accuracy of robot.<\/jats:p>\n<\/jats:sec>","DOI":"10.1108\/ir-05-2018-0102","type":"journal-article","created":{"date-parts":[[2018,10,30]],"date-time":"2018-10-30T07:38:40Z","timestamp":1540885120000},"page":"715-721","source":"Crossref","is-referenced-by-count":15,"title":["A simple and rapid calibration methodology for industrial robot based on geometric constraint and two-step error"],"prefix":"10.1108","volume":"45","author":[{"given":"Jiabo","family":"Zhang","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Xibin","family":"Wang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ke","family":"Wen","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yinghao","family":"Zhou","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yi","family":"Yue","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jizhi","family":"Yang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"140","published-online":{"date-parts":[[2018,10,30]]},"reference":[{"key":"key2022112510133359100_ref001","first-page":"1499","article-title":"Roland simultaneous localization and odometry calibration for mobile robot","volume-title":"Proceedings of the 2003 IEEE\/RSJ international conference on robots and systems","year":"2003"},{"issue":"1\/4","key":"key2022112510133359100_ref002","first-page":"515","article-title":"Kinematic calibration of a six-axis serial robot using distance and sphere constraints","volume":"77","year":"2015","journal-title":"The International Journal of Advanced Manufacturing Technology"},{"issue":"3","key":"key2022112510133359100_ref026","doi-asserted-by":"crossref","first-page":"447","DOI":"10.1017\/S0263574713000714","article-title":"Comparison of two calibration methods for a small industrial robot based on an optical CMM and a laser tracker","volume":"32","year":"2014","journal-title":"Robotica"},{"issue":"8","key":"key2022112510133359100_ref003","first-page":"1427","article-title":"Robotic automatic drilling system","volume":"48","year":"2014","journal-title":"Journal of Zhejiang University (Engineering Science)"},{"key":"key2022112510133359100_ref004","doi-asserted-by":"crossref","first-page":"91","DOI":"10.1016\/j.rcim.2014.08.002","article-title":"Online robot calibration based on hybrid sensors using Kalman filters","volume":"31","year":"2015","journal-title":"Robotics and Computer-Integrated Manufacturing"},{"issue":"5","key":"key2022112510133359100_ref005","doi-asserted-by":"crossref","first-page":"600","DOI":"10.3724\/SP.J.1218.2013.00600","article-title":"Kinematic calibration method of robots based on distance error","volume":"35","year":"2013","journal-title":"Robot"},{"issue":"1","key":"key2022112510133359100_ref006","doi-asserted-by":"crossref","first-page":"44","DOI":"10.1108\/IR-09-2014-0396","article-title":"Absolute accuracy analysis and improvement of a hybrid 6-DOF medical robot","volume":"42","year":"2015","journal-title":"Industrial Robot: An International Journal"},{"issue":"4","key":"key2022112510133359100_ref007","doi-asserted-by":"crossref","first-page":"7933","DOI":"10.3390\/s150407933","article-title":"A method for improving the pose accuracy of a robot manipulator based on Multi-Sensor combined measurement and data fusion","volume":"15","year":"2015","journal-title":"Sensors"},{"key":"key2022112510133359100_ref008","doi-asserted-by":"crossref","first-page":"996","DOI":"10.1016\/j.neucom.2014.03.085","article-title":"A calibration method for enhancing robot accuracy through integration of an extended Kalman filter algorithm and an artificial neural network","volume":"151","year":"2015","journal-title":"Neurocomputing"},{"issue":"1","key":"key2022112510133359100_ref009","doi-asserted-by":"crossref","first-page":"236","DOI":"10.1016\/j.rcim.2012.06.004","article-title":"Absolute calibration of an ABB IRB 1600 robot using a laser tracker","volume":"29","year":"2013","journal-title":"Robotics and Computer-Integrated Manufacturing"},{"issue":"3","key":"key2022112510133359100_ref010","first-page":"198","article-title":"Measurement robot calibration model and algorithm based on distance accuracy","volume":"29","year":"2008","journal-title":"Acta Metrologica Sinica"},{"article-title":"High-accuracy robotic drilling\/milling of 737 inboard flaps","volume-title":"SAE Technical Paper","year":"2011","key":"key2022112510133359100_ref011"},{"issue":"8","key":"key2022112510133359100_ref012","doi-asserted-by":"crossref","first-page":"1","DOI":"10.3901\/JME.2017.08.001","article-title":"Position and attitude measurement and online errors compensation for KUKA industrial robots","volume":"53","year":"2017","journal-title":"Chinese Journal of Mechanical Engineering"},{"issue":"1","key":"key2022112510133359100_ref013","first-page":"18","article-title":"A dual quaternion method for precise calibration of robot\u2019s base frame","volume":"40","year":"2017","journal-title":"Journal of Beijing University of Posts and Telecommunications"},{"issue":"3","key":"key2022112510133359100_ref014","first-page":"47","article-title":"Calibration method of robot base frame using unit quaternion form","volume":"41","year":"2015","journal-title":"Precision Engineering"},{"issue":"2","key":"key2022112510133359100_ref015","doi-asserted-by":"crossref","first-page":"438","DOI":"10.1007\/s10033-017-0093-5","article-title":"Design of a Two-Step calibration method of kinematic parameters for serial robots","volume":"30","year":"2017","journal-title":"Chinese Journal of Mechanical Engineering"},{"issue":"5","key":"key2022112510133359100_ref016","doi-asserted-by":"crossref","first-page":"439","DOI":"10.1108\/IR-04-2014-0319","article-title":"A distance error based industrial robot kinematic calibration method","volume":"41","year":"2014","journal-title":"Industrial Robot: An International Journal"},{"issue":"2","key":"key2022112510133359100_ref025","first-page":"202","article-title":"Calibration of robot kinematic parameters based on laser tracker","volume":"40","year":"2007","journal-title":"Journal of Tianjin University"},{"issue":"9\/12","key":"key2022112510133359100_ref017","first-page":"2745","article-title":"An error-similarity-based robot positional accuracy improvement method for a robotic drilling and riveting system","volume":"88","year":"2017","journal-title":"The International Journal of Advanced Manufacturing Technology"},{"key":"key2022112510133359100_ref018","doi-asserted-by":"crossref","first-page":"113","DOI":"10.1016\/j.rcim.2016.05.011","article-title":"Positional error similarity analysis for error compensation of industrial robots","volume":"42","year":"2016","journal-title":"Robotics and Computer-Integrated Manufacturing"},{"issue":"9","key":"key2022112510133359100_ref019","doi-asserted-by":"crossref","first-page":"195","DOI":"10.3901\/JME.2007.09.195","article-title":"Method of robot calibration based on laser tracker","volume":"43","year":"2007","journal-title":"Chinese Journal of Mechanical Engineering"}],"container-title":["Industrial Robot: An International Journal"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.emerald.com\/insight\/content\/doi\/10.1108\/IR-05-2018-0102\/full\/xml","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.emerald.com\/insight\/content\/doi\/10.1108\/IR-05-2018-0102\/full\/html","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,7,24]],"date-time":"2025-07-24T21:39:05Z","timestamp":1753393145000},"score":1,"resource":{"primary":{"URL":"http:\/\/www.emerald.com\/ir\/article\/45\/6\/715-721\/174527"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,10,30]]},"references-count":21,"journal-issue":{"issue":"6","published-online":{"date-parts":[[2018,10,30]]},"published-print":{"date-parts":[[2018,12,7]]}},"alternative-id":["10.1108\/IR-05-2018-0102"],"URL":"https:\/\/doi.org\/10.1108\/ir-05-2018-0102","relation":{},"ISSN":["0143-991X"],"issn-type":[{"type":"print","value":"0143-991X"}],"subject":[],"published":{"date-parts":[[2018,10,30]]}}}