{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,8,2]],"date-time":"2025-08-02T17:23:32Z","timestamp":1754155412410,"version":"3.41.2"},"reference-count":25,"publisher":"Emerald","issue":"3","license":[{"start":{"date-parts":[[2017,5,15]],"date-time":"2017-05-15T00:00:00Z","timestamp":1494806400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.emerald.com\/insight\/site-policies"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["IR"],"published-print":{"date-parts":[[2017,5,15]]},"abstract":"<jats:sec>\n<jats:title content-type=\"abstract-subheading\">Purpose<\/jats:title>\n<jats:p>Robot-assisted system for minimally invasive surgery (MIS) has been attracting more and more attentions. Compared with a traditional MIS, the robot-assisted system for MIS is able to overcome or reduce defects, such as poor hand-eye coordination, heavy labour intensity and limited motion of the instrument. The purpose of this paper is to design a novel robotic system for MIS applications.<\/jats:p>\n<\/jats:sec>\n<jats:sec>\n<jats:title content-type=\"abstract-subheading\">Design\/methodology\/approach<\/jats:title>\n<jats:p>A robotic system with three separate slave arms for MIS has been designed. In the proposed robot, a new mechanism was designed as the remote centre motion (RCM) mechanism to restrain the movement of instrument or laparoscope around the incision. Moreover, an improved instrument without coupling motion between wrist and grippers was developed to enhance its manipulability. A control system architecture was also developed, and an intuitive control method was applied to realize hand-eye coordination of the operator.<\/jats:p>\n<\/jats:sec>\n<jats:sec>\n<jats:title content-type=\"abstract-subheading\">Findings<\/jats:title>\n<jats:p>For the RCM mechanism, the workspace was analyzed and the positioning accuracy of the remote centre point was tested. The results show that the RCM mechanism can be applied to MIS. Furthermore, the master-slave trajectory tracking experiments reveal that slave robots are able to follow the movement of the master manipulators well. Finally, the feasibility of the robot-assisted system for MIS is proved by performing animal experiments successfully.<\/jats:p>\n<\/jats:sec>\n<jats:sec>\n<jats:title content-type=\"abstract-subheading\">Originality\/value<\/jats:title>\n<jats:p>This paper offers a novel robotic system for MIS. It can accomplish the anticipated results.<\/jats:p>\n<\/jats:sec>","DOI":"10.1108\/ir-07-2016-0181","type":"journal-article","created":{"date-parts":[[2017,5,24]],"date-time":"2017-05-24T07:13:26Z","timestamp":1495610006000},"page":"288-298","source":"Crossref","is-referenced-by-count":3,"title":["Design of a novel robotic system for minimally invasive surgery"],"prefix":"10.1108","volume":"44","author":[{"given":"Yue","family":"Ai","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Bo","family":"Pan","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yili","family":"Fu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Shuguo","family":"Wang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"140","reference":[{"first-page":"5807","article-title":"Task control with remote center of motion constraint for minimally invasive robotic surgery","year":"2013","key":"key2020120719303753600_ref001"},{"issue":"5","key":"key2020120719303753600_ref002","first-page":"818","article-title":"Transforming a surgical robot for human telesurgery","volume":"16","year":"2003","journal-title":"IEEE Transactions on Robotics and Automation"},{"issue":"6","key":"key2020120719303753600_ref003","doi-asserted-by":"crossref","first-page":"508","DOI":"10.1108\/IR-03-2015-0055","article-title":"State of the art in robots used in minimally invasive surgeries. Natural orifice transluminal surgery (notes) as a particular case","volume":"42","year":"2015","journal-title":"Industrial Robot: An International Journal"},{"year":"2002","key":"key2020120719303753600_ref004","article-title":"A telerobotic system for remote surgical collaboration with communication delays"},{"issue":"4","key":"key2020120719303753600_ref005","doi-asserted-by":"crossref","first-page":"324","DOI":"10.1108\/01439910810876427","article-title":"The DLR MIRO: a versatile lightweight robot for surgical applications","volume":"35","year":"2008","journal-title":"Industrial Robot: An International Journal"},{"key":"key2020120719303753600_ref006","first-page":"954","article-title":"Raven-II: an open platform for surgical robotics research","year":"2013","journal-title":"IEEE Transactions on Biomedical Engineering"},{"first-page":"2136","article-title":"Development of a standalone surgical haptic arm","year":"2011","key":"key2020120719303753600_ref007"},{"key":"key2020120719303753600_ref008","unstructured":"Kang, H. (2002), \u201cRobotic assisted suturing in minimally invasive surgery\u201d, PhD thesis, Rensselaer Polytechnic Institute."},{"first-page":"2031","article-title":"Endobot: a robotic assistant in minimally invasive surgeries","year":"2001","key":"key2020120719303753600_ref009"},{"first-page":"1432","article-title":"Autonomous multilateral debridement with the Raven surgical robot","year":"2014","key":"key2020120719303753600_ref010"},{"first-page":"2534","article-title":"Dynamically evaluated gravity compensation for the RAVEN surgical robot","year":"2014","key":"key2020120719303753600_ref011"},{"first-page":"3394","article-title":"Maximizing dexterous workspace and optimal port placement of a multi-arm surgical robot","year":"2011","key":"key2020120719303753600_ref012"},{"key":"key2020120719303753600_ref013","first-page":"176","article-title":"Robin Heart PortVisionAble - idea, design and preliminary testing resutlts","year":"2015","journal-title":"2015 10th International Workshop on Robot Motion and Control (RoMoCo)"},{"key":"key2020120719303753600_ref014","first-page":"1440","article-title":"Optimization of a spherical mechanism for a minimally invasive surgical robot: theoretical and experimental approaches","year":"2006","journal-title":"IEEE Transactions on Biomedical Engineering"},{"issue":"1","key":"key2020120719303753600_ref015","doi-asserted-by":"crossref","first-page":"273","DOI":"10.1007\/s00345-013-1161-9","article-title":"Robotic-assisted laparoendoscopic single-site radical nephrectomy: first experience with the novel Da Vinci single-site platform","volume":"32","year":"2014","journal-title":"World Journal of Urology"},{"key":"key2020120719303753600_ref016","first-page":"393","article-title":"Design and control of a robotic assistant for laparoscopic surgery","year":"2001","journal-title":"The 9th International Symposium on Intelligent Robotic Systems"},{"issue":"10","key":"key2020120719303753600_ref017","first-page":"211","article-title":"On laparoscopic robot design and validation","year":"2003","journal-title":"Integrated Computer-Aided Engineering"},{"issue":"2","key":"key2020120719303753600_ref018","doi-asserted-by":"crossref","first-page":"323","DOI":"10.2478\/v10175-010-0030-6","article-title":"Robin heart progress- advances material and technology in surgical robots","volume":"58","year":"2010","journal-title":"Bulletin of the Polish Academy of Sciences Technical Sciences"},{"issue":"1","key":"key2020120719303753600_ref019","doi-asserted-by":"crossref","first-page":"36","DOI":"10.1002\/rcs.67","article-title":"Polish cardio-robot \u2018Robin Heart\u2019 System description and technical evaluation","volume":"2","year":"2006","journal-title":"The International Journal of Medical Robotics and Computer Assisted Surgery"},{"key":"key2020120719303753600_ref020","doi-asserted-by":"crossref","first-page":"1081","DOI":"10.15439\/2015F239","article-title":"The development of InterNetwork channel emulation platform for Surgical Robot Telemanipulation Control System (INSeRT)","volume":"5","year":"2015","journal-title":"Annals of Computer Science and Information Systems"},{"issue":"26","key":"key2020120719303753600_ref021","first-page":"2117","article-title":"Review of surgical robotics user interface: what is the best way to control robotic surgery","year":"2012","journal-title":"Surgical Endoscopy"},{"issue":"2","key":"key2020120719303753600_ref022","doi-asserted-by":"crossref","first-page":"584","DOI":"10.1016\/j.jvs.2014.11.036","article-title":"The da Vinci Robot in the field of vascular surgery","volume":"61","year":"2015","journal-title":"Journal of Vascular Surgery"},{"issue":"2","key":"key2020120719303753600_ref023","first-page":"681","article-title":"Surgical innovations: addressing the technology gaps in minimally invasive surgery","volume":"3","year":"2013","journal-title":"Trends in Anaesthesia and Critical Care"},{"first-page":"3023","article-title":"The sigma7 haptic interface for MiroSurge: a new bi-manual surgical console","year":"2011","key":"key2020120719303753600_ref024"},{"first-page":"894","article-title":"Development of a flexible imaging probe integrated to a surgical tele-robot system: preliminary remote control test and probe design","year":"2012","key":"key2020120719303753600_ref025"}],"container-title":["Industrial Robot: An International Journal"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.emerald.com\/insight\/content\/doi\/10.1108\/IR-07-2016-0181\/full\/xml","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.emerald.com\/insight\/content\/doi\/10.1108\/IR-07-2016-0181\/full\/html","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,7,24]],"date-time":"2025-07-24T21:39:28Z","timestamp":1753393168000},"score":1,"resource":{"primary":{"URL":"http:\/\/www.emerald.com\/ir\/article\/44\/3\/288-298\/178490"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,5,15]]},"references-count":25,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2017,5,15]]}},"alternative-id":["10.1108\/IR-07-2016-0181"],"URL":"https:\/\/doi.org\/10.1108\/ir-07-2016-0181","relation":{},"ISSN":["0143-991X"],"issn-type":[{"type":"print","value":"0143-991X"}],"subject":[],"published":{"date-parts":[[2017,5,15]]}}}