{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,13]],"date-time":"2026-02-13T17:50:30Z","timestamp":1771005030986,"version":"3.50.1"},"reference-count":22,"publisher":"Emerald","issue":"5","license":[{"start":{"date-parts":[[2015,8,17]],"date-time":"2015-08-17T00:00:00Z","timestamp":1439769600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.emerald.com\/insight\/site-policies"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2015,8,17]]},"abstract":"<jats:sec>\n               <jats:title content-type=\"abstract-heading\">Purpose<\/jats:title>\n               <jats:p> \u2013 The purpose of this paper is to present a robotic motion compensation system, using ultrasound images, to assist orthopedic surgery. The robotic system can compensate for femur movements during bone drilling procedures. Although it may have other applications, the system was thought to be used in hip resurfacing (HR) prosthesis surgery to implant the initial guide tool. The system requires no fiducial markers implanted in the patient, by using only non-invasive ultrasound images. <\/jats:p>\n            <\/jats:sec>\n            <jats:sec>\n               <jats:title content-type=\"abstract-heading\">Design\/methodology\/approach<\/jats:title>\n               <jats:p> \u2013 The femur location in the operating room is obtained by processing ultrasound (USA) and computer tomography (CT) images, obtained, respectively, in the intra-operative and pre-operative scenarios. During surgery, the bone position and orientation is obtained by registration of USA and CT three-dimensional (3D) point clouds, using an optical measurement system and also passive markers attached to the USA probe and to the drill. The system description, image processing, calibration procedures and results with simulated and real experiments are presented and described to illustrate the system in operation. <\/jats:p>\n            <\/jats:sec>\n            <jats:sec>\n               <jats:title content-type=\"abstract-heading\">Findings<\/jats:title>\n               <jats:p> \u2013 The robotic system can compensate for femur movements, during bone drilling procedures. In most experiments, the update was always validated, with errors of 2 mm\/4\u00b0. <\/jats:p>\n            <\/jats:sec>\n            <jats:sec>\n               <jats:title content-type=\"abstract-heading\">Originality\/value<\/jats:title>\n               <jats:p> \u2013 The navigation system is based entirely on the information extracted from images obtained from CT pre-operatively and USA intra-operatively. Contrary to current surgical systems, it does not use any type of implant in the bone to track the femur movements.<\/jats:p>\n            <\/jats:sec>","DOI":"10.1108\/ir-12-2014-0435","type":"journal-article","created":{"date-parts":[[2015,8,5]],"date-time":"2015-08-05T08:52:33Z","timestamp":1438764753000},"page":"466-474","source":"Crossref","is-referenced-by-count":8,"title":["Robotic motion compensation for bone movement, using ultrasound images"],"prefix":"10.1108","volume":"42","author":[{"given":"P.M.B.","family":"Torres","sequence":"first","affiliation":[]},{"given":"P. J. S.","family":"Gon\u00e7alves","sequence":"additional","affiliation":[]},{"given":"J.M.M.","family":"Martins","sequence":"additional","affiliation":[]}],"member":"140","reference":[{"key":"key2020122201130291400_b11","doi-asserted-by":"crossref","unstructured":"Adams, L.\n               , \n                  Krybus, W.\n               , \n                  Meyer-Ebrecht, D.\n               , \n                  Rueger, R.\n               , \n                  Gilsbach, J.M.\n               , \n                  Moesges, R.\n                and \n                  Schloendorff, G.\n                (1990), \u201cComputer-assisted surgery\u201d, \n                  Computer Graphics and Applications, IEEE\n               , Vol. 10 No. 3, pp. 43-51.","DOI":"10.1109\/38.55152"},{"key":"key2020122201130291400_b17","doi-asserted-by":"crossref","unstructured":"Besl, P.J.\n                and \n                  McKay, N.D.\n                (1992), \u201cA method for registration of 3-D shapes\u201d, \n                  Pattern Analysis and Machine Intelligence\n               , Vol. 14 No. 2, pp. 239-256.","DOI":"10.1109\/34.121791"},{"key":"key2020122201130291400_b14","unstructured":"Catarino, N.M.M.\n                (2012), \u201cBone contour segmentation from US images \u2013 a comparative study\u201d, Proceedings of RECPAD 2012, 18th Portuguese Conference on Pattern Recognition, Coimbra."},{"key":"key2020122201130291400_b21","doi-asserted-by":"crossref","unstructured":"Chen, X.\n               , \n                  Bao, N.\n               , \n                  Li, J.\n                and \n                  Kang, Y.\n                (2012), \u201cA review of surgery navigation system based on ultrasound guidance\u201d, International Conference on Information and Automation (ICIA), Shenyang, pp. 882-886.","DOI":"10.1109\/ICInfA.2012.6246906"},{"key":"key2020122201130291400_b7","doi-asserted-by":"crossref","unstructured":"Cobb, J.\n               , \n                  Henckel, J.\n               , \n                  Gomes, P.\n               , \n                  Harris, S.\n               , \n                  Jakopec, M.\n               , \n                  Rodriguez, F.\n               , \n                  Barrett, A.\n                and \n                  Davies, B.\n                (2006), \u201cHands-on robotic unicompartmental knee replacement: a prospective, randomised controlled study of the acrobot system\u201d, \n                  The Journal of Bone and Joint Surgery B\n               , Vol. 88 No. 2, pp. 188-197.","DOI":"10.1302\/0301-620X.88B2.17220"},{"key":"key2020122201130291400_b10","doi-asserted-by":"crossref","unstructured":"De Smet, K.\n               , \n                  Campbell, P.\n                and \n                  Van Der Straeten, C.\n                (2013), \n                  The Hip Resurfacing Handbook: A Practical Guide to the Use and Management of Modern Hip Resurfacings\n               , Woodhead Publishing Series in Biomaterials, Cambridge.","DOI":"10.1533\/9780857096203"},{"key":"key2020122201130291400_b5","doi-asserted-by":"crossref","unstructured":"Echeverria, G.\n               , \n                  Lassabe, N.\n               , \n                  Degroote, A.\n                and \n                  Lemaignan, S.\n                (2011), \u201cModular open robots simulation engine: MORSE\u201d, IEEE International Conference on Robotics and Automation (ICRA), Shanghai, pp. 46-51.","DOI":"10.1109\/ICRA.2011.5980252"},{"key":"key2020122201130291400_b15","unstructured":"Gon\u00e7alves, P.\n                and \n                  Torres, P.\n                (2010), \u201cExtracting bone contours in ultrasound images: energetic versus probabilistic methods\u201d, \n                  Romanian Review Precision Mechanics, Optics & Mechatronics\n               , Vol. 37 No. 1, pp. 105-110."},{"key":"key2020122201130291400_b16","unstructured":"Gon\u00e7alves, P.J.S.\n               , \n                  Torres, P.M.B.\n               , \n                  Santos, F.\n               , \n                  Ant\u00f3nio, R.\n               , \n                  Catarino, N.\n                and \n                  Martins, J.M.M.\n                (2014), \u201cA vision system for robotic ultrasound guided orthopaedic surgery\u201d, \n                  Journal of Intelligent and Robotic Systems\n               , Vol. 77 No. 2, pp. 1-13."},{"key":"key2020122201130291400_b6","doi-asserted-by":"crossref","unstructured":"Hamarneh, G.\n               , \n                  Amir-Khalili, A.\n               , \n                  Nosrati, M.S.\n               , \n                  Figueroa, I.\n               , \n                  Kawahara, J.\n               , \n                  Al-Alao, O.\n               , \n                  Peyrat, J.M.\n               , \n                  Abi-Nahed, J.\n               , \n                  Al-Ansari, A.\n                and \n                  Abugharbieh, R.\n                (2014), \u201cTowards multi-modal image-guided tumour identification in robot-assisted partial nephrectomy\u201d, Middle East Conference on Biomedical Engineering (MECBME), Burnaby, BC, pp. 159-162.","DOI":"10.1109\/MECBME.2014.6783230"},{"key":"key2020122201130291400_b18","doi-asserted-by":"crossref","unstructured":"Kazanzides, P.\n               , \n                  Mittelstadt, B.D.\n               , \n                  Musits, B.L.\n               , \n                  Bargar, W.L.\n               , \n                  Zuhars, J.F.\n               , \n                  Williamson, B.\n               , \n                  Cain, P.W.\n                and \n                  Carbone, E.J.\n                (1995), \u201cAn integrated system for cementless hip replacement\u201d, \n                  Engineering in Medicine and Biology Magazine, IEEE\n               , Vol. 14 No. 3, pp. 307-313.","DOI":"10.1109\/51.391772"},{"key":"key2020122201130291400_b22","doi-asserted-by":"crossref","unstructured":"Li, Z.\n               , \n                  Gu, J.\n               , \n                  Chakareski, J.\n                and \n                  Wang, L.\n                (2011), \u201cUltrasound-based surgical navigation for percutaneous renal intervention: in vivo measurements and in vitro assessment\u201d, 18th IEEE International Conference on Image Processing (ICIP), Shenzen, pp. 2185-2188.","DOI":"10.1109\/ICIP.2011.6116067"},{"key":"key2020122201130291400_b3","doi-asserted-by":"crossref","unstructured":"McMinn, D.J.W.\n                (2009), \u201cImplantation of the femoral component of the birmingham hip resurfacing\u201d, \n                  Modern Hip Resurfacing\n               , Springer, New York, NY, pp. 265-283.","DOI":"10.1007\/978-1-84800-088-9_22"},{"key":"key2020122201130291400_b4","doi-asserted-by":"crossref","unstructured":"M\u00e9moli, F.\n                and \n                  Sapiro, G.\n                (2004), \u201cComparing point clouds\u201d, Proceedings of the 2004 Eurographics\/ACM SIGGRAPH Symposium on Geometry Processing, SGP \u201904, ACM, New York, NY, pp. 32-40.","DOI":"10.1145\/1057432.1057436"},{"key":"key2020122201130291400_b2","doi-asserted-by":"crossref","unstructured":"Myronenko, A.\n                and \n                  Song, X.\n                (2010), \u201cPoint set registration: coherent point drift\u201d, \n                  IEEE Transactions on Pattern Analysis and Machine Intelligence\n               , Vol. 32 No. 12, pp. 2262-2275.","DOI":"10.1109\/TPAMI.2010.46"},{"key":"key2020122201130291400_b1","unstructured":"Pearle, A.D.\n               , \n                  Kendoff, D.\n               , \n                  Stueber, V.\n               , \n                  Musahl, V.\n                and \n                  Repicci, J.A.\n                (2009), \u201cPerioperative management of unicompartmental knee arthroplasty using the MAKO robotic arm system (MAKOplasty)\u201d, \n                  American Journal of Orthopedics\n               , Vol. 38 No. 2, pp. 16-19."},{"key":"key2020122201130291400_b12","doi-asserted-by":"crossref","unstructured":"Peterhans, M.\n               , \n                  Talib, H.\n               , \n                  Linguraru, M.G.\n               , \n                  Styner, M.\n               , \n                  Ballester, G\n                and \n                  Miguel, A.\n                (2008), \u201cA method for frame-by-frame us to CT registration in a joint calibration and registration framework\u201d, \n                  5th IEEE International Symposium on Biomedical Imaging: From Nano to Macro\n               , ISBI, pp. 1131-1134.","DOI":"10.1109\/ISBI.2008.4541200"},{"key":"key2020122201130291400_b13","unstructured":"Raaijmaakers, M.\n               , \n                  Gelaude, F.\n               , \n                  De Smedt, K.\n               , \n                  Clijmans, T.\n               , \n                  Dille, J.\n                and \n                  Mulier, M.\n                (2010), \u201cA custom-made guide-wire positioning device for hip surface replacement arthroplasty: description and first results\u201d, \n                  BMC Musculoskeletal Disorders\n               , Vol. 11 No. 161."},{"key":"key2020122201130291400_b8","doi-asserted-by":"crossref","unstructured":"Sanches, J.\n               , \n                  Nascimento, J.C.\n                and \n                  Marques, J.S.\n                (2008), \u201cMedical image noise reduction using the Sylvester-Lyapunov equation\u201d, \n                  IEEE Transactions on Image Processing\n               , Vol. 17 No. 9, pp. 1522-1539.","DOI":"10.1109\/TIP.2008.2001398"},{"key":"key2020122201130291400_b9","doi-asserted-by":"crossref","unstructured":"Sethian, J.\n                (1999), \n                  Level Set Methods and Fast Marching Methods\n               , Cambridge University Press, Cambridge.","DOI":"10.1137\/S0036144598347059"},{"key":"key2020122201130291400_b19","doi-asserted-by":"crossref","unstructured":"Rusu, R.\n                and \n                  Cousins, S.\n                (2011), \u201c3D is here: point cloud library (PCL)\u201d, IEEE International Conference on Robotics and Automation (ICRA), Kobe, pp. 1-4.","DOI":"10.1109\/ICRA.2011.5980567"},{"key":"key2020122201130291400_b20","doi-asserted-by":"crossref","unstructured":"Taylor, R.\n                (2006), \u201cA perspective on medical robotics\u201d, \n                  Proceedings of the IEEE\n               , Vol. 94 No. 9, pp. 1652-1664.","DOI":"10.1109\/JPROC.2006.880669"}],"container-title":["Industrial Robot: An International Journal"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/www.emeraldinsight.com\/doi\/full-xml\/10.1108\/IR-12-2014-0435","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.emerald.com\/insight\/content\/doi\/10.1108\/IR-12-2014-0435\/full\/xml","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.emerald.com\/insight\/content\/doi\/10.1108\/IR-12-2014-0435\/full\/html","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,7,24]],"date-time":"2025-07-24T21:40:33Z","timestamp":1753393233000},"score":1,"resource":{"primary":{"URL":"http:\/\/www.emerald.com\/ir\/article\/42\/5\/466-474\/185037"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2015,8,17]]},"references-count":22,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2015,8,17]]}},"alternative-id":["10.1108\/IR-12-2014-0435"],"URL":"https:\/\/doi.org\/10.1108\/ir-12-2014-0435","relation":{},"ISSN":["0143-991X"],"issn-type":[{"value":"0143-991X","type":"print"}],"subject":[],"published":{"date-parts":[[2015,8,17]]}}}