{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,18]],"date-time":"2026-03-18T09:45:16Z","timestamp":1773827116424,"version":"3.50.1"},"reference-count":26,"publisher":"Emerald","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"abstract":"<jats:sec>\n                    <jats:title>Purpose<\/jats:title>\n                    <jats:p>The pre-analytical phase is a critical step in medical biology analyses, encompassing all stages from test ordering to sample presentation on the analyzer. The aim of this study is to propose a quality management approach for handling non-conformities in the pre-analytical phase of a medical analysis laboratory.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Design\/methodology\/approach<\/jats:title>\n                    <jats:p>This study investigated various pre-analytical non-conformities in a medical biology laboratory in Casablanca over an 8-month period. To address the primary causes of these non-conformities, we employed several quality tools, including FMECA, Ishikawa diagram, Pareto diagram, and brainstorming. Our work was structured according to the Plan-Do-Check-Act cycle. Excel was used for data processing and diagram creation, while Zotero managed bibliographic references.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Findings<\/jats:title>\n                    <jats:p>Two non-conformities were classified as high-criticality: the first concerned sampling errors (incorrect patient identification and non-compliant labeling), and the second involved non-compliant subcontracting samples. After determining the root causes of these two nonconformities, we implemented corrective actions and achieved a 46% improvement for the non-conforming during sampling and a 49% improvement for the non-conforming subcontracting samples.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Originality\/value<\/jats:title>\n                    <jats:p>After the first PDCA cycle, we achieved a significant improvement in the two non-conformities studied. Using quality tools, we prioritized the most critical non-conformities for immediate action. In addition, other methods enabled us to identify all the potential causes of these two non-conformities, pinpointing those responsible for 80% of their occurrence. A second PDCA cycle will be implemented to further improve the results obtained in the first cycle.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1108\/ijhcqa-11-2025-0206","type":"journal-article","created":{"date-parts":[[2026,3,18]],"date-time":"2026-03-18T07:41:14Z","timestamp":1773819674000},"page":"1-11","source":"Crossref","is-referenced-by-count":0,"title":["Management of non-conformities in the pre-analytical phase of the medical analysis laboratory"],"prefix":"10.1108","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-6748-1468","authenticated-orcid":true,"given":"Hind","family":"Kechkar","sequence":"first","affiliation":[{"name":"Clinical Immunology, Infection and Autoimmunity Laboratory, Hassan II University of Casablanca Faculty of Medicine and Pharmacy, , ,","place":["Casablanca, Morocco"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jihad","family":"Boukhaldi","sequence":"additional","affiliation":[{"name":"Clinical Immunology, Infection and Autoimmunity Laboratory, Hassan II University of Casablanca Faculty of Medicine and Pharmacy, , ,","place":["Casablanca, Morocco"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Abderrazak","family":"Sabri","sequence":"additional","affiliation":[{"name":"Clinical Immunology, Infection and Autoimmunity Laboratory, Hassan II University of Casablanca Faculty of Medicine and Pharmacy, , ,","place":["Casablanca, Morocco"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mohamed","family":"Omari","sequence":"additional","affiliation":[{"name":"Research Laboratory for Care, Health and Sustainable Development, Team 3: Health Sciences, Education and Management, Higher Institute of Nursing Professions and Health Techniques of Casablanca , ,","place":["Casablanca, Morocco"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Asmaa","family":"Morjan","sequence":"additional","affiliation":[{"name":"Clinical Immunology, Infection and Autoimmunity Laboratory, Hassan II University of Casablanca Faculty of Medicine and Pharmacy, , ,","place":["Casablanca, Morocco"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jalila","family":"Elbakkouri","sequence":"additional","affiliation":[{"name":"Clinical Immunology, Infection and Autoimmunity Laboratory, Hassan II University of Casablanca Faculty of Medicine and Pharmacy, , ,","place":["Casablanca, Morocco"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ahmed Aziz","family":"Bousfiha","sequence":"additional","affiliation":[{"name":"Clinical Immunology, Infection and Autoimmunity Laboratory, Hassan II University of Casablanca Faculty of Medicine and Pharmacy, , ,","place":["Casablanca, Morocco"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Nabiha","family":"Kamal","sequence":"additional","affiliation":[{"name":"Clinical Immunology, Infection and Autoimmunity Laboratory, Hassan II University of Casablanca Faculty of Medicine and Pharmacy, , ,","place":["Casablanca, Morocco"]}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"140","published-online":{"date-parts":[[2026,3,20]]},"reference":[{"issue":"1","key":"2026031803404498400_ref001","doi-asserted-by":"publisher","first-page":"114","DOI":"10.64483\/jmph-52","article-title":"Quality control of laboratory medicine: preventing errors for diagnostic reliability","volume":"1","author":"Alsharari","year":"2024","journal-title":"Saudi Journal of Medicine and Public Health"},{"issue":"S9","key":"2026031803404498400_ref002","first-page":"1902","article-title":"A comprehensive review of errors in medical laboratories and strategies for improvement","volume":"7","author":"Alzaidi","year":"2024","journal-title":"Journal of International Crisis and Risk Communication Research"},{"issue":"2","key":"2026031803404498400_ref003","doi-asserted-by":"publisher","first-page":"15","DOI":"10.21522\/tijph.2013.11.02.art002","article-title":"Effect of pre-analytical errors in laboratory testing facilities: the way forward","volume":"11","author":"Cordelia Enyanwu","year":"2023","journal-title":"Texila International Journal of Public Health"},{"issue":"2","key":"2026031803404498400_ref004","doi-asserted-by":"publisher","first-page":"183","DOI":"10.21522\/TIJPH.2013.11.02.Art019","article-title":"Quality management of the pre-analytical phase errors: monitoring and way forward","volume":"11","author":"Cordelia Enyanwu","year":"2023","journal-title":"Texila International Journal of Public Health"},{"issue":"2","key":"2026031803404498400_ref005","doi-asserted-by":"publisher","first-page":"1","DOI":"10.4212\/cjhp.3631","article-title":"Risk analysis of the hazardous drug control circuit using the FMEA method","volume":"78","author":"El Kara","year":"2025","journal-title":"Canadian Journal of Hospital Pharmacy"},{"issue":"1","key":"2026031803404498400_ref006","doi-asserted-by":"publisher","first-page":"87","DOI":"10.1684\/abc.2019.1410","article-title":"Analysis and management of the pre-analytical risks in hemostasis","volume":"77","author":"El Kettani","year":"2019","journal-title":"Annales de Biologie Clinique"},{"issue":"5","key":"2026031803404498400_ref007","doi-asserted-by":"publisher","first-page":"615","DOI":"10.1684\/abc.2013.0881","article-title":"Internal audit in medical laboratory: what means of control for an effective audit process?","volume":"71","author":"Garcia-Hejl","year":"2013","journal-title":"Annales de Biologie Clinique"},{"issue":"5","key":"2026031803404498400_ref008","doi-asserted-by":"publisher","first-page":"519","DOI":"10.1016\/j.therap.2023.12.004","article-title":"Chronology of the ISO 9001:2015 certification and satisfaction survey in the multidisciplinary Clinical Investigation Center (CIC) of the historic Saint-Louis Hospital during the COVID-19 pandemic","volume":"79","author":"Ghrieb","year":"2024","journal-title":"Therapie"},{"issue":"2","key":"2026031803404498400_ref009","doi-asserted-by":"publisher","first-page":"29","DOI":"10.30699\/mmlj17.6.2.29","article-title":"Assessment of pre-analytical and analytical performance using sigma metrics and quality goal index: a case study on liver profile analysis from Benghazi medical center","volume":"6","author":"Hamid","year":"2023","journal-title":"Modern Medical Laboratory Journal"},{"key":"2026031803404498400_ref010","author":"International Organization for Standardization","year":"2012"},{"issue":"3","key":"2026031803404498400_ref011","first-page":"247","article-title":"Control of non-conformities in the pre-analytical phase at the bacteriology laboratory of the Ibn Sina University hospital in Rabat (Morocco)","volume":"100","author":"Jnah","year":"2022","journal-title":"La Tunisie Medicale"},{"issue":"191","key":"2026031803404498400_ref012","first-page":"28","article-title":"Quality approach for the management of pre-analytical non-conformities in a medical biology laboratory","volume":"30","author":"Kamal","year":"2011","journal-title":"Spectra Biologie"},{"issue":"7","key":"2026031803404498400_ref013","first-page":"612","article-title":"Pre-analytical non-conformities of cytobacteriological examination of urine in the microbiology laboratory of Oujda\u2019s Mohammed VI University Hospital","volume":"101","author":"Lahmer","year":"2023","journal-title":"La Tunisie Medicale"},{"key":"2026031803404498400_ref014","doi-asserted-by":"publisher","first-page":"4925","DOI":"10.2147\/JMDH.S486276","article-title":"Quality control circle practices to reduce specimen rejection rates","volume":"17","author":"Li","year":"2024","journal-title":"Journal of Multidisciplinary Healthcare"},{"key":"2026031803404498400_ref015","article-title":"Order of the Minister of Health No. 2598-10 on the guide to good practice for medical biology analysis","author":"Moroccan GPGA","year":"2010"},{"issue":"2","key":"2026031803404498400_ref016","first-page":"171","article-title":"Characterization of pre-analytical errors using six sigma metrics and process capability index in a clinical biochemistry laboratory","volume":"11","author":"Mukhopadhyay","year":"2021","journal-title":"International Journal of Health Sciences and Research"},{"issue":"2","key":"2026031803404498400_ref017","doi-asserted-by":"publisher","first-page":"78","DOI":"10.5935\/1676-2444.20160016","article-title":"Analysis of the pre-analytical phase in a private pathology laboratory of Maring\u00e1 city-PR, Brazil","volume":"52","author":"Oliveira","year":"2016","journal-title":"Jornal Brasileiro de Patologia e Medicina Laboratorial"},{"issue":"5","key":"2026031803404498400_ref018","doi-asserted-by":"publisher","first-page":"713","DOI":"10.1515\/cclm-2022-0755","article-title":"Quality in laboratory medicine and the Journal: walking together","volume":"61","author":"Plebani","year":"2023","journal-title":"Clinical Chemistry and Laboratory Medicine"},{"issue":"4","key":"2026031803404498400_ref019","doi-asserted-by":"publisher","first-page":"310","DOI":"10.2478\/v10011-010-0039-2","article-title":"Medical errors: pre-analytical issue in patient safety","volume":"29","author":"Plebani","year":"2010","journal-title":"Journal of Medical Biochemistry"},{"issue":"6","key":"2026031803404498400_ref020","doi-asserted-by":"publisher","first-page":"943","DOI":"10.1515\/cclm-2014-1124","article-title":"Performance criteria and quality indicators for the pre-analytical phase","volume":"53","author":"Plebani","year":"2015","journal-title":"Clinical Chemistry and Laboratory Medicine"},{"issue":"4","key":"2026031803404498400_ref021","doi-asserted-by":"publisher","first-page":"474","DOI":"10.35516\/jmj.v58i4.1683","article-title":"A comprehensive evaluation of the preanalytical phase in laboratory medicine, nephrology, emergency specialties, visceral surgery, pediatrics, internal medicine and neonatology hospital Departments: in-depth insights derived from an analysis of practices at a medical University Centre in Morocco","volume":"58","author":"Rahhab","year":"2024","journal-title":"Jordan Medical Journal"},{"issue":"4","key":"2026031803404498400_ref022","doi-asserted-by":"publisher","first-page":"288","DOI":"10.7416\/ai.2016.2108","article-title":"Use of a systematic risk analysis method (FMECA) to improve quality in a clinical laboratory procedure","volume":"28","author":"Serafini","year":"2016","journal-title":"Annali di Igiene: Medicina Preventiva e di Comunita"},{"issue":"10","key":"2026031803404498400_ref023","doi-asserted-by":"publisher","first-page":"1418","DOI":"10.6026\/9732063002001418","article-title":"Evaluation of pre-analytical errors using six sigma metrics towards quality of laboratory performance in an Indian tertiary care hospital","volume":"20","author":"Seth","year":"2024","journal-title":"Bioinformation"},{"issue":"1","key":"2026031803404498400_ref024","doi-asserted-by":"publisher","first-page":"6","DOI":"10.37184\/lnjpc.2707-3521.4.7","article-title":"Assessment of total laboratory errors in clinical chemistry laboratory: experience at a tertiary care hospital","volume":"4","author":"Syeda Sabahat","year":"2022","journal-title":"Liaquat National Journal of Primary Care"},{"issue":"9","key":"2026031803404498400_ref025","first-page":"79","article-title":"An interventional study on total testing process of clinical chemistry laboratory of a tertiary care teaching hospital","volume":"6","author":"Toshniwal Pawan","year":"2017","journal-title":"International Journal of Medical Research and Health Sciences"},{"issue":"531","key":"2026031803404498400_ref026","doi-asserted-by":"publisher","first-page":"74","DOI":"10.1016\/S1773-035X(21)00112-X","article-title":"Risk analysis applied to the pre-analytical process of a histocompatibility laboratory","volume":"2021","author":"Yakhlef","year":"2021","journal-title":"Revue Francophone des Laboratoires"}],"container-title":["International Journal of Health Care Quality Assurance"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.emerald.com\/ijhcqa\/article-pdf\/doi\/10.1108\/IJHCQA-11-2025-0206\/11337894\/ijhcqa-11-2025-0206en.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/www.emerald.com\/ijhcqa\/article-pdf\/doi\/10.1108\/IJHCQA-11-2025-0206\/11337894\/ijhcqa-11-2025-0206en.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,3,18]],"date-time":"2026-03-18T07:41:18Z","timestamp":1773819678000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.emerald.com\/ijhcqa\/article\/doi\/10.1108\/IJHCQA-11-2025-0206\/1349346\/Management-of-non-conformities-in-the-pre"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,3,20]]},"references-count":26,"URL":"https:\/\/doi.org\/10.1108\/ijhcqa-11-2025-0206","relation":{},"ISSN":["0952-6862","1758-6542"],"issn-type":[{"value":"0952-6862","type":"print"},{"value":"1758-6542","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,3,20]]}}}