{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,24]],"date-time":"2026-01-24T16:05:44Z","timestamp":1769270744478,"version":"3.49.0"},"reference-count":18,"publisher":"Emerald","issue":"3","license":[{"start":{"date-parts":[[2016,9,12]],"date-time":"2016-09-12T00:00:00Z","timestamp":1473638400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.emerald.com\/insight\/site-policies"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["JSFE"],"published-print":{"date-parts":[[2016,9,12]]},"abstract":"<jats:sec>\n<jats:title content-type=\"abstract-subheading\">Purpose<\/jats:title>\n<jats:p>This paper aims to present the results of a study on the behaviour of cold-formed galvanized steel beams subjected to fire, using the results of a large programme of experimental tests.<\/jats:p>\n<\/jats:sec>\n<jats:sec>\n<jats:title content-type=\"abstract-subheading\">Design\/methodology\/approach<\/jats:title>\n<jats:p>The research investigated the influence of web stiffeners in the sections and the stiffness of the surrounding structure, including the axial and rotational restraining to the thermal elongation, on the flexural behaviour of the beams in case of fire. In other words, the structural response of different open cold-formed steel beams, with and without web stiffeners, was compared in case of fire.<\/jats:p>\n<\/jats:sec>\n<jats:sec>\n<jats:title content-type=\"abstract-subheading\">Findings<\/jats:title>\n<jats:p>The results showed that a good choice between using cold-formed steel beams, with and without web stiffeners, may depend on the section shape and the internal forces generated in these members during a fire.<\/jats:p>\n<\/jats:sec>\n<jats:sec>\n<jats:title content-type=\"abstract-subheading\">Originality\/value<\/jats:title>\n<jats:p>Temperatures in the furnace and at several points of the beams, as well as deformations and restraining forces and moments, were measured to achieve those goals and consequently to assess the critical time and temperature of these beams.<\/jats:p>\n<\/jats:sec>","DOI":"10.1108\/jsfe-09-2016-018","type":"journal-article","created":{"date-parts":[[2017,1,9]],"date-time":"2017-01-09T06:02:20Z","timestamp":1483941740000},"page":"249-261","source":"Crossref","is-referenced-by-count":8,"title":["Influence of web stiffeners on cold-formed steel beams subjected to fire"],"prefix":"10.1108","volume":"7","author":[{"given":"Joao Paulo C.","family":"Rodrigues","sequence":"first","affiliation":[]},{"given":"Luis","family":"Laim","sequence":"additional","affiliation":[]},{"given":"H\u00e9lder David","family":"Craveiro","sequence":"additional","affiliation":[]}],"member":"140","reference":[{"key":"key2020121300420256700_ref006","doi-asserted-by":"crossref","first-page":"1213","DOI":"10.1016\/j.tws.2008.02.004","article-title":"A parametric study on the longitudinal stiffeners of web panels","volume":"46","year":"2008","journal-title":"Thin-Walled Structures"},{"issue":"2","key":"key2020121300420256700_ref013","first-page":"1","article-title":"Effect of cold-straining on structural sheet steels","volume":"89,","year":"1963","journal-title":"Journal of the Structural Division, Proceedings of the American Society of Civil Engineers"},{"issue":"4","key":"key2020121300420256700_ref003","doi-asserted-by":"crossref","first-page":"378","DOI":"10.1016\/j.ijmecsci.2005.11.005","article-title":"Local and distortional buckling of cold-formed zed-section beams under uniformly distributed transverse loads","volume":"48","year":"2006","journal-title":"International Journal of Mechanical Sciences"},{"key":"key2020121300420256700_ref004","doi-asserted-by":"crossref","first-page":"771","DOI":"10.1016\/j.tws.2010.01.005","article-title":"Local\/distortional mode interaction in cold-formed steel lipped channel beams","volume":"48","year":"2010","journal-title":"Thin-walled Structures"},{"issue":"3\/4","key":"key2020121300420256700_ref005","first-page":"422","article-title":"Post-buckling behaviour and strength of cold-formed steel lipped channel columns experiencing distortional\/global interaction","volume":"89","year":"2011","journal-title":"Computers and Structures"},{"key":"key2020121300420256700_ref015","article-title":"Design of steel structures","volume-title":"General Rules and Rules For Buildings","author":"EN1993-1.1","year":"2004"},{"key":"key2020121300420256700_ref016","article-title":"Design of steel structures","volume-title":"General Rule: Supplementary Rules for Cold-Formed Members and Sheeting","author":"EN1993-1.3(","year":"2004"},{"key":"key2020121300420256700_ref017","article-title":"Eurocode 3: design of steel structures","volume-title":"Part 1-5: Plated Structural Elements","author":"EN1993-1-5","year":"2006"},{"key":"key2020121300420256700_ref011","doi-asserted-by":"crossref","first-page":"106","DOI":"10.1016\/j.tws.2012.02.013","article-title":"Local and distortional buckling of cold-formed steel beams with both edge and intermediate stiffeners in their compression flanges","volume":"54","year":"2012","journal-title":"Thin-Walled Structures"},{"key":"key2020121300420256700_ref018","article-title":"Fire resistance tests \u2013 elements of building construction","volume-title":"Part 1: General Requirements","author":"ISO 834-1(","year":"1999"},{"key":"key2020121300420256700_ref014","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.tws.2013.06.008","article-title":"Experimental and numerical analysis on the structural behaviour of cold-formed steel beams","volume":"72","year":"2013","journal-title":"Thin-Walled Structures"},{"issue":"12","key":"key2020121300420256700_ref010","doi-asserted-by":"crossref","first-page":"2099","DOI":"10.1016\/j.jcsr.2009.06.017","article-title":"Analyses of distortional buckling of cold-formed sigma purlins using EN1993-1-3","volume":"65","year":"2009","journal-title":"Journal of Constructional Steel Research"},{"key":"key2020121300420256700_ref008","doi-asserted-by":"crossref","first-page":"19","DOI":"10.1016\/j.tws.2013.09.002","article-title":"Direct strength method of design for shear including sections with longitudinal web stiffeners","volume":"81","year":"2014","journal-title":"Thin-Walled Structures"},{"issue":"3","key":"key2020121300420256700_ref001","doi-asserted-by":"crossref","first-page":"314","DOI":"10.1016\/j.tws.2006.03.009","article-title":"Analysis and design of cold-formed steel channels subjected to combined bending and web crippling","volume":"44","year":"2006","journal-title":"Thin-Walled Structures"},{"issue":"1","key":"key2020121300420256700_ref012","first-page":"65","article-title":"The behaviour and design of longitudinally stiffened thin-walled compression elements","volume":"27","year":"1998","journal-title":"Thin-Walled Structures"},{"key":"key2020121300420256700_ref002","doi-asserted-by":"crossref","first-page":"1225","DOI":"10.1016\/j.jcsr.2008.08.007","article-title":"Experimental and numerical investigation on cold-formed steel C-section flexural members","volume":"65","year":"2009","journal-title":"Journal of Constructional Steel Research"},{"key":"key2020121300420256700_ref009","doi-asserted-by":"crossref","first-page":"81","DOI":"10.1016\/j.tws.2014.08.002","article-title":"Design of cold-formed steel channels with stiffened webs subjected to bending","volume":"85","year":"2014","journal-title":"Thin-Walled Structures"},{"key":"key2020121300420256700_ref007","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.tws.2011.11.006","article-title":"Compression tests of cold-formed steel I-shaped open sections with edge and web stiffeners","volume":"52","year":"2012","journal-title":"Thin-Walled Structures"}],"container-title":["Journal of Structural Fire Engineering"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/www.emeraldinsight.com\/doi\/full-xml\/10.1108\/JSFE-09-2016-018","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.emerald.com\/insight\/content\/doi\/10.1108\/JSFE-09-2016-018\/full\/xml","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.emerald.com\/insight\/content\/doi\/10.1108\/JSFE-09-2016-018\/full\/html","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,7,24]],"date-time":"2025-07-24T22:23:24Z","timestamp":1753395804000},"score":1,"resource":{"primary":{"URL":"http:\/\/www.emerald.com\/jsfe\/article\/7\/3\/249-261\/246601"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2016,9,12]]},"references-count":18,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2016,9,12]]}},"alternative-id":["10.1108\/JSFE-09-2016-018"],"URL":"https:\/\/doi.org\/10.1108\/jsfe-09-2016-018","relation":{},"ISSN":["2040-2317"],"issn-type":[{"value":"2040-2317","type":"print"}],"subject":[],"published":{"date-parts":[[2016,9,12]]}}}