{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,29]],"date-time":"2026-04-29T19:36:58Z","timestamp":1777491418777,"version":"3.51.4"},"reference-count":30,"publisher":"Emerald","issue":"1","license":[{"start":{"date-parts":[[2015,4,13]],"date-time":"2015-04-13T00:00:00Z","timestamp":1428883200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.emerald.com\/insight\/site-policies"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2015,4,13]]},"abstract":"<jats:sec>\n               <jats:title content-type=\"abstract-heading\">Purpose<\/jats:title>\n               <jats:p> \u2013 Infrared thermography is increasingly being used to diagnose pathologies in buildings, such as fa\u00e7ade defects. The purpose of this paper is to assess the results reproducibility and the equipment influence on the measurements. To do so, it was defined as case study the assessment of rendering delamination. <\/jats:p>\n            <\/jats:sec>\n            <jats:sec>\n               <jats:title content-type=\"abstract-heading\">Design\/methodology\/approach<\/jats:title>\n               <jats:p> \u2013 Two infrared cameras of different makers were used to detect the presence of defects deliberately created in specimens. The tests were done in the laboratory with a heat source. The defects were detected through a temperature gradient between the zones with and without defect. <\/jats:p>\n            <\/jats:sec>\n            <jats:sec>\n               <jats:title content-type=\"abstract-heading\">Findings<\/jats:title>\n               <jats:p> \u2013 With this thermographic imaging, it was possible to identify the defects in the specimen both qualitatively and quantitatively. The results were found to be reproducible in the three cycles performed. The influence of the equipment on the results was of little significance for the quantitative assessment criterion \u201ctemperature difference between zones with and without defect\u201d, but for the criterion \u201cabsolute surface temperature\u201d, the difference in the results yielded by the two cameras was around 1.8\u00b0C. <\/jats:p>\n            <\/jats:sec>\n            <jats:sec>\n               <jats:title content-type=\"abstract-heading\">Originality\/value<\/jats:title>\n               <jats:p> \u2013 The results suggest that there is reproducibility of the measurements, considering both the qualitative and quantitative approach, when assessing delamination, irrespective of the maker of the equipment used. The influence of the equipment on the results depends on the quantitative assessment criterion used.<\/jats:p>\n            <\/jats:sec>","DOI":"10.1108\/ss-05-2014-0021","type":"journal-article","created":{"date-parts":[[2015,4,2]],"date-time":"2015-04-02T11:49:16Z","timestamp":1427975356000},"page":"20-35","source":"Crossref","is-referenced-by-count":36,"title":["Infrared thermography \u2013 evaluation of the results reproducibility"],"prefix":"10.1108","volume":"33","author":[{"given":"Elton","family":"Bauer","sequence":"first","affiliation":[]},{"given":"Vasco Peixoto","family":"de Freitas","sequence":"additional","affiliation":[]},{"given":"Niubis","family":"Mustelier","sequence":"additional","affiliation":[]},{"given":"Eva","family":"Barreira","sequence":"additional","affiliation":[]},{"given":"Sara Stingl","family":"de Freitas","sequence":"additional","affiliation":[]}],"member":"140","reference":[{"key":"key2020122422191120800_b1","doi-asserted-by":"crossref","unstructured":"Asdrubali, F.\n               , \n                  Baldinelli, G.\n                and \n                  Bianchi, F.\n                (2012), \u201cA quantitative methodology to evaluate thermal bridges in buildings\u201d, \n                  Applied Energy\n               , Vol. 97, pp. 365-373.","DOI":"10.1016\/j.apenergy.2011.12.054"},{"key":"key2020122422191120800_b2","unstructured":"ASTM E1862\n                (1997\/2010), \u201cStandard test methods for measuring and compensating for reflected temperature using infrared imaging radiometers\u201d, ASTM International."},{"key":"key2020122422191120800_b4","doi-asserted-by":"crossref","unstructured":"Avdelidis, N.\n                and \n                  Moropoulou, A.\n                (2003), \u201cEmissivity considerations in building thermography\u201d, \n                  Energy and Buildings\n               , Vol. 35 No. 7, pp. 663-667.","DOI":"10.1016\/S0378-7788(02)00210-4"},{"key":"key2020122422191120800_b5","doi-asserted-by":"crossref","unstructured":"Avdelidis, N.\n                and \n                  Moropoulou, A.\n                (2004), \u201cApplications of infrared thermography for the investigation of historic structures\u201d, \n                  Journal of Cultural Heritage\n               , Vol. 5 No. 1, pp. 119-127.","DOI":"10.1016\/j.culher.2003.07.002"},{"key":"key2020122422191120800_b3","doi-asserted-by":"crossref","unstructured":"Avdelidis, N.\n               , \n                  Moropoulou, A.\n                and \n                  Theoulakis, P.\n                (2003), \u201cDetection of water deposits and movement in porous materials by infrared imaging\u201d, \n                  Infrared Physics & Technology\n               , Vol. 44 No. 3, pp. 183-190.","DOI":"10.1016\/S1350-4495(02)00212-8"},{"key":"key2020122422191120800_b6","doi-asserted-by":"crossref","unstructured":"Balaras, C.\n                and \n                  Argiriou, A.\n                (2002), \u201cInfrared thermography for building diagnostics\u201d, \n                  Energy and Buildings\n               , Vol. 34 No. 2, pp. 171-183.","DOI":"10.1016\/S0378-7788(01)00105-0"},{"key":"key2020122422191120800_b7","doi-asserted-by":"crossref","unstructured":"Barreira, E.\n                and \n                  de Freitas, V.P.\n                (2007), \u201cEvaluation of building materials using infrared thermography\u201d, \n                  Construction and Building Materials\n               , Vol. 21 No. 1, pp. 218-224.","DOI":"10.1016\/j.conbuildmat.2005.06.049"},{"key":"key2020122422191120800_b8","unstructured":"Bauer, E.\n               , \n                  Castro, E.K.\n               , \n                  Leal, F.E.\n                and \n                  Antunes, G.R.\n                (2011), \u201cIdentification and quantification of failure modes of new buildings fa\u00e7ades in Bras\u00edlia\u201d, Proceedings of XII International Conference On Durability Of Building Materials And Components, Porto, Vol. 3, Feup Edi\u00e7\u00f5es, pp. 1089-1096."},{"key":"key2020122422191120800_b9","doi-asserted-by":"crossref","unstructured":"Cerdeira, F.\n               , \n                  V\u00e1zquez, M.E.\n               , \n                  Collazo, J.\n                and \n                  Granada, E.\n                (2011), \u201cApplicability of infrared thermography to the study of the behavior of stone panel as building envelopes\u201d, \n                  Energy and Buildings\n               , Vol. 43, pp. 1845-1851.","DOI":"10.1016\/j.enbuild.2011.03.029"},{"key":"key2020122422191120800_b10","doi-asserted-by":"crossref","unstructured":"Chew, M.\n                (1998), \u201cAssessing building fa\u00e7ades using infra-red thermography\u201d, \n                  Structural Survey\n               , Vol. 16 No. 2, pp. 81-86.","DOI":"10.1108\/02630809810219669"},{"key":"key2020122422191120800_b11","unstructured":"Chown, G.A.\n                and \n                  Burn, K.N.\n                (1983), \u201cThermographic identification of buildings enclosure defects and deficiencies\u201d, \n                  Canadian Building Digest 229\n               , NRC-IRC, National Research Council Canada, Division of Building Research, Ottawa, Ontario, 4pp."},{"key":"key2020122422191120800_b12","unstructured":"de Freitas, S.S.\n               , \n                  de Freitas, V.P.\n                and \n                  Barreira, E.\n                (2013), \u201cApplication of infrared thermography to the diagnosis of Fa\u00e7ade rendering detachment\u201d, \n                  A State of the Art Report on Building Pathology\n               , Publication 393, CIB Edition, International Council for Research and Innovation in Building and Construction, W086 Building Pathology, Rotterdam, 7pp."},{"key":"key2020122422191120800_b800","doi-asserted-by":"crossref","unstructured":"de Freitas, S.S.\n               , \n                  de Freitas, V.P.\n                and \n                  Barreira, E.\n                (2014), \u201cDetection of fa\u00e7ade plaster detachments using infrared thermography \u2013 a nondestructive technique\u201d, \n                  Construction and Building Materials\n               , Vol. 70, pp. 80-87.","DOI":"10.1016\/j.conbuildmat.2014.07.094"},{"key":"key2020122422191120800_b14","doi-asserted-by":"crossref","unstructured":"Edis, E.\n               , \n                  Flores-Colen, I.\n                and \n                  de Brito, J.\n                (2014), \u201cPassive thermographic detection of moisture problems in fa\u00e7ades with adhered ceramic cladding\u201d, \n                  Construction and Building Materials\n               , Vol. 51, pp. 187-197.","DOI":"10.1016\/j.conbuildmat.2013.10.085"},{"key":"key2020122422191120800_b15","unstructured":"Fatiguso, F.\n                and \n                  Sciotti, A.\n                (2013), \u201cA diagnostic methodological, approach: innovative aspects for masonry structures\u201d, \n                  A State of the Art Report on Building Pathology\n               , Publication 393, CIB Edition, International Council for Research and Innovation in Building and Construction, W086 Building Pathology, Rotterdam, 8pp."},{"key":"key2020122422191120800_b16","unstructured":"FLIR\n                (n.d.), \n                  FLIR T400 \u2013 Operation Manual\n               , FLIR, Oak Ridge, Tennessee."},{"key":"key2020122422191120800_b17","doi-asserted-by":"crossref","unstructured":"Grinzato, E.\n                (2012), \u201cState of the art and perspective of infrared thermography applied to building science\u201d, in \n                  Meola, C.\n                (Ed.), \n                  Infrared Thermography Recent Advances and Future Trends\n               , Bentham Books, Bussum, 30pp.","DOI":"10.2174\/978160805143411201010200"},{"key":"key2020122422191120800_b18","doi-asserted-by":"crossref","unstructured":"Grinzato, E.\n               , \n                  Cadelano, G.\n                and \n                  Bison, P.\n                (2010), \u201cMoisture map by IR thermography\u201d, \n                  Journal of Modern Optics\n               , Vol. 57 No. 18, pp. 1770-1778.","DOI":"10.1080\/09500341003731597"},{"key":"key2020122422191120800_b19","unstructured":"Infrared Training Center (ITC)\n                (2013), \n                  Thermography Level 1 Course Manual\n               , Infrared Training Center, Sorocaba, S\u00e3o Paulo."},{"key":"key2020122422191120800_b20","doi-asserted-by":"crossref","unstructured":"Lerma, J.\n               , \n                  Cabrelles, M.\n                and \n                  Portal\u00e9s, C.\n                (2011), \u201cMultitemporal thermal analysis to detect moisture on a building fa\u00e7ade\u201d, \n                  Construction and Building Materials\n               , Vol. 25 No. 5, pp. 2190-2197.","DOI":"10.1016\/j.conbuildmat.2010.10.007"},{"key":"key2020122422191120800_b21","doi-asserted-by":"crossref","unstructured":"Lo, S.M.\n                (1999), \u201cThe use of thermography for the detection of external finishes defects of buildings in Hong Kong\u201d, \n                  Structural Survey\n               , Vol. 17 No. 1, pp. 22-26.","DOI":"10.1108\/02630809910258683"},{"key":"key2020122422191120800_b22","unstructured":"Maldague, X.P.V.\n                (2001), \n                  Theory and Practice of Infrared Technology for Nondestructive Testing\n               , John Wiley & Sons, New York, NY."},{"key":"key2020122422191120800_b23","doi-asserted-by":"crossref","unstructured":"Minkina, W.\n                and \n                  Dudzik, S.\n                (2009), \n                  Infrared Thermography: Errors and Uncertainties\n               , John Wiley & Sons. New York, NY.","DOI":"10.1002\/9780470682234"},{"key":"key2020122422191120800_b24","unstructured":"NEC\n                (n.d.), \n                  Thermo Tracer NEC TH9100 \u2013 Operation Manual\n               , NEC, Tokyo."},{"key":"key2020122422191120800_b25","doi-asserted-by":"crossref","unstructured":"Oca\u00f1a, S.\n               , \n                  Guerrero, I.\n                and \n                  Requena, I.\n                (2004), \u201cThermographic survey of two rural buildings in Spain\u201d, \n                  Energy and Buildings\n               , Vol. 36 No. 6, pp. 515-523.","DOI":"10.1016\/j.enbuild.2003.12.012"},{"key":"key2020122422191120800_b26","doi-asserted-by":"crossref","unstructured":"Porras-Amores, C.\n               , \n                  Mazarr\u00f3n, F.R.\n                and \n                  Ca\u00f1as, I.\n                (2013), \u201cUsing quantitative infrared thermography to determine indoor air temperature\u201d, \n                  Energy and Buildings\n               , Vol. 65, pp. 292-298.","DOI":"10.1016\/j.enbuild.2013.06.022"},{"key":"key2020122422191120800_b27","unstructured":"Rao, P.\n                (2008), \u201cInfrared thermography and its applications to civil engineering\u201d, \n                  The Indian Concrete Journal\n               , Vol. 82 No. 5, pp. 41-50."},{"key":"key2020122422191120800_b28","unstructured":"Sakagami, T.\n               , \n                  Komiyama, T.\n                and \n                  Suzuki, H.\n                (1999), \u201cProposal for a new thermographic non-destructive testing technique using microwave heating\u201d, Proceedings of the Thermosense XXI, \n                  International Society for Optical Engineering (SPIE)\n               , \n                  Orlando, FL\n               , pp. 99-103."},{"key":"key2020122422191120800_b29","doi-asserted-by":"crossref","unstructured":"Sim\u00f5es, N.\n               , \n                  Sim\u00f5es, I.\n               , \n                  Tadeu, A.\n                and \n                  Serra, C.\n                (2012), \u201cEvaluation of adhesive bonding of ceramic tiles using active thermography\u201d, Proceedings of the 11th International Conference on Quantitative InfraRed Thermography, Naples, 11-14 June.","DOI":"10.21611\/qirt.2012.362"},{"key":"key2020122422191120800_b30","doi-asserted-by":"crossref","unstructured":"Theodorakeas, P.\n               , \n                  Ibarra-Castanedo, C.\n               , \n                  Sfarra, S.\n               , \n                  Avdelidis, N.P.\n               , \n                  Koui,M.\n               , \n                  Maldague, X.\n               , \n                  Paoletti, D.\n                and \n                  Ambrosini, D.\n                (2012), \u201cNDT inspection of plastered mosaics by means of transient thermography and holographic interferometry\u201d, \n                  NDT&E International\n               , Vol. 47, pp. 150-156.","DOI":"10.1016\/j.ndteint.2012.01.004"}],"container-title":["Structural Survey"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/www.emeraldinsight.com\/doi\/full-xml\/10.1108\/SS-05-2014-0021","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.emerald.com\/insight\/content\/doi\/10.1108\/SS-05-2014-0021\/full\/xml","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.emerald.com\/insight\/content\/doi\/10.1108\/SS-05-2014-0021\/full\/html","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,7,24]],"date-time":"2025-07-24T21:43:57Z","timestamp":1753393437000},"score":1,"resource":{"primary":{"URL":"http:\/\/www.emerald.com\/ijbpa\/article\/33\/1\/20-35\/354594"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2015,4,13]]},"references-count":30,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2015,4,13]]}},"alternative-id":["10.1108\/SS-05-2014-0021"],"URL":"https:\/\/doi.org\/10.1108\/ss-05-2014-0021","relation":{},"ISSN":["0263-080X"],"issn-type":[{"value":"0263-080X","type":"print"}],"subject":[],"published":{"date-parts":[[2015,4,13]]}}}