{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,12,18]],"date-time":"2025-12-18T18:46:33Z","timestamp":1766083593387,"version":"3.48.0"},"reference-count":50,"publisher":"Institute of Electrical and Electronics Engineers (IEEE)","license":[{"start":{"date-parts":[[2019,1,1]],"date-time":"2019-01-01T00:00:00Z","timestamp":1546300800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/legalcode"}],"funder":[{"DOI":"10.13039\/501100001809","name":"National Natural Science Foundation of China","doi-asserted-by":"publisher","award":["51777196"],"award-info":[{"award-number":["51777196"]}],"id":[{"id":"10.13039\/501100001809","id-type":"DOI","asserted-by":"publisher"}]},{"name":"ERC Program of the NSF and DOE"},{"DOI":"10.13039\/100000001","name":"National Science Foundation","doi-asserted-by":"publisher","award":["EEC-1041877"],"award-info":[{"award-number":["EEC-1041877"]}],"id":[{"id":"10.13039\/100000001","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["IEEE Access"],"published-print":{"date-parts":[[2019]]},"DOI":"10.1109\/access.2019.2953774","type":"journal-article","created":{"date-parts":[[2019,11,15]],"date-time":"2019-11-15T16:03:51Z","timestamp":1573833831000},"page":"168637-168648","source":"Crossref","is-referenced-by-count":21,"title":["Mitigation of Cascading Outages Using a Dynamic Interaction Graph-Based Optimal Power Flow Model"],"prefix":"10.1109","volume":"7","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-9128-4165","authenticated-orcid":false,"given":"Changsheng","family":"Chen","sequence":"first","affiliation":[{"name":"China Electric Power Research Institute, Beijing, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4143-9496","authenticated-orcid":false,"given":"Wenyun","family":"Ju","sequence":"additional","affiliation":[{"name":"Electric Power Group, LLC, Pasadena, CA, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-0305-2725","authenticated-orcid":false,"given":"Kai","family":"Sun","sequence":"additional","affiliation":[{"name":"Department of Electrical Engineering and Computer Science, The University of Tennessee, Knoxville, TN, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1910-3515","authenticated-orcid":false,"given":"Shiying","family":"Ma","sequence":"additional","affiliation":[{"name":"China Electric Power Research Institute, Beijing, China"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"263","reference":[{"key":"ref39","doi-asserted-by":"publisher","DOI":"10.1109\/TPWRS.2018.2838046"},{"key":"ref38","doi-asserted-by":"publisher","DOI":"10.1109\/TPWRS.2014.2357713"},{"key":"ref33","doi-asserted-by":"publisher","DOI":"10.1109\/TPWRS.2016.2578259"},{"key":"ref32","first-page":"2141","article-title":"&#x2018;Dual graph&#x2019; and &#x2018;random chemistry&#x2019; methods for cascading failure analysis","author":"hines","year":"2013","journal-title":"Proc 46th Hawaii Int Conf Syst Sci"},{"key":"ref31","doi-asserted-by":"publisher","DOI":"10.1073\/pnas.1110586109"},{"key":"ref30","doi-asserted-by":"publisher","DOI":"10.1038\/nature08932"},{"key":"ref37","doi-asserted-by":"publisher","DOI":"10.1109\/TII.2018.2867064"},{"key":"ref36","doi-asserted-by":"publisher","DOI":"10.1109\/JETCAS.2017.2703948"},{"key":"ref35","doi-asserted-by":"publisher","DOI":"10.1109\/TPWRS.2017.2764041"},{"key":"ref34","doi-asserted-by":"publisher","DOI":"10.1109\/TPWRS.2014.2337284"},{"key":"ref28","doi-asserted-by":"publisher","DOI":"10.1109\/TCNS.2018.2843168"},{"key":"ref27","doi-asserted-by":"publisher","DOI":"10.1109\/TPEL.2018.2881720"},{"key":"ref29","doi-asserted-by":"publisher","DOI":"10.1016\/j.ssci.2009.02.002"},{"journal-title":"Arizona Southern California Outage on September 8 2011","year":"2012","key":"ref2"},{"key":"ref1","doi-asserted-by":"publisher","DOI":"10.1109\/TPWRS.2005.857942"},{"key":"ref20","doi-asserted-by":"publisher","DOI":"10.1209\/0295-5075\/111\/38006"},{"key":"ref22","doi-asserted-by":"publisher","DOI":"10.1109\/ACCESS.2019.2937903"},{"key":"ref21","doi-asserted-by":"publisher","DOI":"10.1109\/TSG.2018.2858234"},{"key":"ref24","doi-asserted-by":"publisher","DOI":"10.1109\/TSG.2018.2865316"},{"key":"ref23","doi-asserted-by":"publisher","DOI":"10.1109\/TSG.2017.2785267"},{"key":"ref26","doi-asserted-by":"publisher","DOI":"10.1109\/ACCESS.2019.2915927"},{"key":"ref25","doi-asserted-by":"publisher","DOI":"10.1109\/TCSII.2018.2869941"},{"key":"ref50","doi-asserted-by":"publisher","DOI":"10.1016\/j.epsr.2018.07.016"},{"key":"ref10","doi-asserted-by":"publisher","DOI":"10.1063\/1.1505810"},{"key":"ref11","doi-asserted-by":"publisher","DOI":"10.1109\/TPWRS.2008.926417"},{"key":"ref40","doi-asserted-by":"publisher","DOI":"10.1049\/iet-gtd.2017.1393"},{"key":"ref12","doi-asserted-by":"publisher","DOI":"10.1109\/HICSS.2013.594"},{"key":"ref13","doi-asserted-by":"crossref","first-page":"814","DOI":"10.1109\/TPWRS.2009.2016521","article-title":"An improved OPA model and blackout risk assessment","volume":"24","author":"mei","year":"2009","journal-title":"IEEE Trans Power Syst"},{"key":"ref14","doi-asserted-by":"publisher","DOI":"10.1109\/TPWRS.2012.2230196"},{"key":"ref15","doi-asserted-by":"crossref","first-page":"1719","DOI":"10.1109\/TPWRS.2008.2002295","article-title":"A study of self-organized criticality of power system under cascading failures based on AC-OPF with voltage stability margin","volume":"23","author":"mei","year":"2008","journal-title":"IEEE Trans Power Syst"},{"key":"ref16","doi-asserted-by":"publisher","DOI":"10.1109\/TPWRS.2015.2439237"},{"key":"ref17","doi-asserted-by":"publisher","DOI":"10.1109\/TPWRS.2015.2466116"},{"key":"ref18","doi-asserted-by":"publisher","DOI":"10.1109\/ACCESS.2018.2851022"},{"key":"ref19","doi-asserted-by":"publisher","DOI":"10.1109\/TPWRS.2013.2263851"},{"key":"ref4","doi-asserted-by":"publisher","DOI":"10.1109\/TPWRS.2018.2809793"},{"key":"ref3","doi-asserted-by":"publisher","DOI":"10.1109\/ICMLC.2013.6890450"},{"key":"ref6","doi-asserted-by":"publisher","DOI":"10.1109\/TPWRS.2002.800872"},{"key":"ref5","doi-asserted-by":"publisher","DOI":"10.1109\/67.526849"},{"key":"ref8","doi-asserted-by":"publisher","DOI":"10.1017\/S0269964805050023"},{"key":"ref7","doi-asserted-by":"publisher","DOI":"10.1109\/TPWRS.2004.831665"},{"key":"ref49","doi-asserted-by":"publisher","DOI":"10.1109\/TPWRS.2015.2493101"},{"key":"ref9","doi-asserted-by":"publisher","DOI":"10.1109\/HICSS.2001.926274"},{"key":"ref46","doi-asserted-by":"publisher","DOI":"10.1109\/TPWRS.2009.2036461"},{"key":"ref45","doi-asserted-by":"publisher","DOI":"10.1109\/PTC.2009.5282151"},{"key":"ref48","doi-asserted-by":"publisher","DOI":"10.1109\/TPWRS.2013.2283175"},{"key":"ref47","doi-asserted-by":"publisher","DOI":"10.1109\/TPWRS.2005.860942"},{"key":"ref42","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijepes.2018.05.001"},{"key":"ref41","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijepes.2012.08.064"},{"key":"ref44","doi-asserted-by":"publisher","DOI":"10.1016\/j.epsr.2011.04.003"},{"key":"ref43","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijepes.2013.03.025"}],"container-title":["IEEE Access"],"original-title":[],"link":[{"URL":"http:\/\/xplorestaging.ieee.org\/ielx7\/6287639\/8600701\/08902050.pdf?arnumber=8902050","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,12,18]],"date-time":"2025-12-18T18:34:30Z","timestamp":1766082870000},"score":1,"resource":{"primary":{"URL":"https:\/\/ieeexplore.ieee.org\/document\/8902050\/"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019]]},"references-count":50,"URL":"https:\/\/doi.org\/10.1109\/access.2019.2953774","relation":{},"ISSN":["2169-3536"],"issn-type":[{"type":"electronic","value":"2169-3536"}],"subject":[],"published":{"date-parts":[[2019]]}}}