{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,7]],"date-time":"2026-02-07T11:04:36Z","timestamp":1770462276908,"version":"3.49.0"},"reference-count":24,"publisher":"Institute of Electrical and Electronics Engineers (IEEE)","license":[{"start":{"date-parts":[[2023,1,1]],"date-time":"2023-01-01T00:00:00Z","timestamp":1672531200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"funder":[{"name":"Norwegian Research Council's INTPART programme","award":["309241"],"award-info":[{"award-number":["309241"]}]},{"DOI":"10.13039\/501100005311","name":"Key Science and Technology Projects of China Southern Power Grid Corporation","doi-asserted-by":"publisher","award":["CGYKJXM20210338"],"award-info":[{"award-number":["CGYKJXM20210338"]}],"id":[{"id":"10.13039\/501100005311","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["IEEE Access"],"published-print":{"date-parts":[[2023]]},"DOI":"10.1109\/access.2023.3280027","type":"journal-article","created":{"date-parts":[[2023,5,25]],"date-time":"2023-05-25T17:56:56Z","timestamp":1685037416000},"page":"63451-63462","source":"Crossref","is-referenced-by-count":10,"title":["Optimized Design of Shed Parameters for Polluted Hollow Porcelain Insulators at High Altitude"],"prefix":"10.1109","volume":"11","author":[{"ORCID":"https:\/\/orcid.org\/0009-0003-4000-652X","authenticated-orcid":false,"given":"Ziwei","family":"Qiu","sequence":"first","affiliation":[{"name":"Xuefeng Mountain Energy Equipment Safety National Observation and Research Station, Chongqing University, Chongqing, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yong","family":"Sun","sequence":"additional","affiliation":[{"name":"Maintenance &#x0026; Test Centre of EHV Power Transmission Company, China Southern Power Grid, Guangzhou, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yanjie","family":"Cui","sequence":"additional","affiliation":[{"name":"Maintenance &#x0026; Test Centre of EHV Power Transmission Company, China Southern Power Grid, Guangzhou, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-8893-2264","authenticated-orcid":false,"given":"Zhijin","family":"Zhang","sequence":"additional","affiliation":[{"name":"Xuefeng Mountain Energy Equipment Safety National Observation and Research Station, Chongqing University, Chongqing, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yuhao","family":"Liu","sequence":"additional","affiliation":[{"name":"Xuefeng Mountain Energy Equipment Safety National Observation and Research Station, Chongqing University, Chongqing, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Xuye","family":"Chen","sequence":"additional","affiliation":[{"name":"Xuefeng Mountain Energy Equipment Safety National Observation and Research Station, Chongqing University, Chongqing, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0009-0008-1961-7728","authenticated-orcid":false,"given":"Yufan","family":"Wu","sequence":"additional","affiliation":[{"name":"Xuefeng Mountain Energy Equipment Safety National Observation and Research Station, Chongqing University, Chongqing, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Chao","family":"Li","sequence":"additional","affiliation":[{"name":"Xuefeng Mountain Energy Equipment Safety National Observation and Research Station, Chongqing University, Chongqing, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Lin","family":"Wang","sequence":"additional","affiliation":[{"name":"Xuefeng Mountain Energy Equipment Safety National Observation and Research Station, Chongqing University, Chongqing, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0009-0008-4144-2717","authenticated-orcid":false,"given":"Zhengfei","family":"Lei","sequence":"additional","affiliation":[{"name":"Xuefeng Mountain Energy Equipment Safety National Observation and Research Station, Chongqing University, Chongqing, China"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"263","reference":[{"key":"ref13","first-page":"1","article-title":"Research on shed spacing optimization and shed parameters selection of composite post insulators for UHV DC voltage at high altitudes","author":"gu","year":"2017","journal-title":"Proc EPTC Power Transmiss Transformation Technol Conf"},{"key":"ref24","first-page":"2335","article-title":"Optimization of composite insulators&#x2019; sheds for 1000 kV UHV AC transmission lines","volume":"35","author":"wang","year":"2009","journal-title":"High Voltage Eng"},{"key":"ref12","doi-asserted-by":"publisher","DOI":"10.1109\/TDEI.2014.004528"},{"key":"ref23","first-page":"17","article-title":"The influence of low atmosphere pressure on flashover voltage of contaminated glass plate","volume":"18","author":"zhang","year":"1994","journal-title":"Power Syst Technol"},{"key":"ref15","article-title":"The effect of booster shed on external insulation of 500 kV transformer high-voltage bushing under rain condition","author":"yao","year":"2019"},{"key":"ref14","first-page":"7","article-title":"Design and simulation optimization of new 12 kV wall bushing","author":"ma","year":"2017","journal-title":"Electr Eng"},{"key":"ref20","first-page":"17","article-title":"Calculation and analysis for the electric filed of composite high voltage bushing","volume":"30","author":"jiang","year":"2004","journal-title":"High Voltage Eng"},{"key":"ref11","doi-asserted-by":"publisher","DOI":"10.1109\/TDEI.2006.258193"},{"key":"ref22","doi-asserted-by":"publisher","DOI":"10.1103\/PhysRevE.99.043106"},{"key":"ref10","doi-asserted-by":"publisher","DOI":"10.1016\/j.asej.2016.08.012"},{"key":"ref21","article-title":"Research on property and protection measures of contaminated station insulator&#x2019;s heavy rain flashover","author":"chai","year":"2017"},{"key":"ref2","first-page":"2284","article-title":"Influences of fog-haze on external insulation of transmission and distribution equipments","volume":"37","author":"su","year":"2013","journal-title":"Power Syst Technol"},{"key":"ref1","first-page":"52","article-title":"To prevent the big bushing flashover the focal point of external insulation design of the UHV transformation equipment","volume":"34","author":"su","year":"2001","journal-title":"Electronics& Power"},{"key":"ref17","article-title":"Study on AC pollution flashover performance of composite insulators with different umbrella configurations under low air pressure and discharge process","author":"yuan","year":"2010"},{"key":"ref16","first-page":"1930","article-title":"Shed parameter optimization of large-diameter composite post insulators under wet condition based on electric field simulation","volume":"43","author":"li","year":"2017","journal-title":"High Voltage Eng"},{"key":"ref19","first-page":"944","article-title":"Influencing factors of insulator electric field analysis by finite element method and its optimization","volume":"37","author":"xu","year":"2011","journal-title":"High Voltage Eng"},{"key":"ref18","article-title":"Electrical field distribution calculation and analysis of effect factors on hydrophobicity of 10 kV composite insulator","author":"li","year":"2002"},{"key":"ref8","first-page":"433","article-title":"Flashover characteristics of post insulators under fog and haze conditions","volume":"45","author":"wang","year":"2019","journal-title":"High Voltage Eng"},{"key":"ref7","article-title":"Research on optimization of shed parameters and DC pollution flashover performance for composite post insulators at high altitude","author":"gu","year":"2014"},{"key":"ref9","article-title":"Composite insulators profile optimization using particle swarm algorithm and finite element method","author":"el-refaie","year":"2015","journal-title":"Proc of the 11th Int Symp on High-Voltage Engineering (ISH)"},{"key":"ref4","article-title":"Analysis of the pollution flashover condition of insulators in traction substation and the design and implementation of simulation device","author":"pan","year":"2020"},{"key":"ref3","first-page":"9","article-title":"Differential protection action caused by pollution flashover of 10 kV main transformer bushing","volume":"56","author":"zhao","year":"2015","journal-title":"Electr World"},{"key":"ref6","first-page":"159","article-title":"AC pollution flashover performance and comparison of short samples of 750 kV composite insulators with different configuration in high altitude area","volume":"25","author":"jiang","year":"2005","journal-title":"Proc CSEE"},{"key":"ref5","first-page":"3615","article-title":"Pollution flashover properties and its mechanism of external insulation structures with high vertical electric field component","volume":"46","author":"zhu","year":"2020","journal-title":"High Voltage Eng"}],"container-title":["IEEE Access"],"original-title":[],"link":[{"URL":"http:\/\/xplorestaging.ieee.org\/ielx7\/6287639\/10005208\/10134551.pdf?arnumber=10134551","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,7,27]],"date-time":"2023-07-27T14:50:07Z","timestamp":1690469407000},"score":1,"resource":{"primary":{"URL":"https:\/\/ieeexplore.ieee.org\/document\/10134551\/"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023]]},"references-count":24,"URL":"https:\/\/doi.org\/10.1109\/access.2023.3280027","relation":{},"ISSN":["2169-3536"],"issn-type":[{"value":"2169-3536","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023]]}}}