{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,25]],"date-time":"2026-09-25T16:15:02Z","timestamp":1790352902040,"version":"4.1.0"},"reference-count":32,"publisher":"Institute of Electrical and Electronics Engineers (IEEE)","license":[{"start":{"date-parts":[[2023,1,1]],"date-time":"2023-01-01T00:00:00Z","timestamp":1672531200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100014174","name":"Project of State Grid Hubei Electric Power Company Ltd.","doi-asserted-by":"publisher","award":["52153222001F"],"award-info":[{"award-number":["52153222001F"]}],"id":[{"id":"10.13039\/501100014174","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["IEEE Access"],"published-print":{"date-parts":[[2023]]},"DOI":"10.1109\/access.2023.3327337","type":"journal-article","created":{"date-parts":[[2023,10,25]],"date-time":"2023-10-25T13:58:25Z","timestamp":1698242305000},"page":"120754-120765","source":"Crossref","is-referenced-by-count":18,"title":["Identification of Single-Phase Line Break Fault Direction Based on Local Voltage Information in Small Current Grounding System Considering the Impact of DG"],"prefix":"10.1109","volume":"11","author":[{"given":"Fan","family":"Yang","sequence":"first","affiliation":[{"name":"Electric Power Research Institute, State Grid Hubei Electric Power Company, Wuhan, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9535-8413","authenticated-orcid":false,"given":"He","family":"Li","sequence":"additional","affiliation":[{"name":"College of New Energy, China University of Petroleum (East China), Qingdao, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Wei","family":"Hu","sequence":"additional","affiliation":[{"name":"Electric Power Research Institute, State Grid Hubei Electric Power Company, Wuhan, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yang","family":"Lei","sequence":"additional","affiliation":[{"name":"Electric Power Research Institute, State Grid Hubei Electric Power Company, Wuhan, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4213-5769","authenticated-orcid":false,"given":"Hechong","family":"Chen","sequence":"additional","affiliation":[{"name":"Electric Power Research Institute, State Grid Hubei Electric Power Company, Wuhan, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yongduan","family":"Xue","sequence":"additional","affiliation":[{"name":"College of New Energy, China University of Petroleum (East China), Qingdao, China"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"263","reference":[{"key":"ref13","doi-asserted-by":"publisher","DOI":"10.1109\/CPRE.2015.7102175"},{"key":"ref12","doi-asserted-by":"publisher","DOI":"10.1109\/TPWRD.2020.3045969"},{"key":"ref15","first-page":"135","article-title":"Fault identification and isolation of distribution network based on zero-sequence voltage amplitude difference","volume":"42","author":"chang","year":"2018","journal-title":"Autom Electr Power Syst"},{"key":"ref14","first-page":"74","article-title":"Analysis of not-short circuit faults in neutral indirectly grounding system","volume":"37","author":"yu","year":"2009","journal-title":"Power Syst Protection Control"},{"key":"ref31","first-page":"3065","article-title":"Characteristic analysis and fault segment location on negative sequence voltage and current of single phase line breakage fault in distribution network","volume":"44","author":"chang","year":"2020","journal-title":"Power Syst Technol"},{"key":"ref30","first-page":"83","article-title":"Novel method for measuring capacitive current and distinguishing high-resistance grounding of distributing network","volume":"32","author":"zhang","year":"2008","journal-title":"Automation of Electronic Power Systems"},{"key":"ref11","doi-asserted-by":"publisher","DOI":"10.1109\/CIEEC50170.2021.9510437"},{"key":"ref10","doi-asserted-by":"publisher","DOI":"10.1109\/EI2.2018.8582598"},{"key":"ref32","first-page":"1521","article-title":"Measuring method of capacitance to ground in resonant grounding system based on transient information after arc extinguishing","volume":"35","author":"xue","year":"2020","journal-title":"Trans China Electrotechnical Soc"},{"key":"ref2","doi-asserted-by":"publisher","DOI":"10.1049\/iet-gtd.2010.0351"},{"key":"ref1","first-page":"2340","article-title":"Research on effects of neutral grounding modes on power supply reliability in distribution networks","volume":"39","author":"guo","year":"2015","journal-title":"Power Syst Technol"},{"key":"ref17","doi-asserted-by":"publisher","DOI":"10.1109\/ACCESS.2021.3055236"},{"key":"ref16","doi-asserted-by":"publisher","DOI":"10.1109\/ACCESS.2022.3175513"},{"key":"ref19","doi-asserted-by":"publisher","DOI":"10.1109\/ACCESS.2021.3076022"},{"key":"ref18","doi-asserted-by":"publisher","DOI":"10.1109\/TPWRD.2022.3142186"},{"key":"ref24","doi-asserted-by":"publisher","DOI":"10.1109\/APPEEC.2016.7779551"},{"key":"ref23","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijepes.2019.105610"},{"key":"ref26","doi-asserted-by":"publisher","DOI":"10.1049\/iet-gtd.2019.1874"},{"key":"ref25","doi-asserted-by":"publisher","DOI":"10.1016\/j.egyr.2023.04.274"},{"key":"ref20","doi-asserted-by":"publisher","DOI":"10.1109\/TPWRD.2014.2327074"},{"key":"ref22","doi-asserted-by":"publisher","DOI":"10.1109\/TPWRD.2022.3215542"},{"key":"ref21","first-page":"1322","article-title":"Analysis of voltage characteristics of single-phase disconnection fault in ungrounded distribution system","volume":"41","author":"xue","year":"2021","journal-title":"Proc Chin Soc Electr Eng"},{"key":"ref28","doi-asserted-by":"publisher","DOI":"10.1109\/IEEESTD.2019.8755346"},{"key":"ref27","first-page":"6","article-title":"Detection of PT breaking based on the theory of line voltage amplitude comparison","volume":"12","author":"zhang","year":"2005","journal-title":"Relay"},{"key":"ref29","first-page":"36","article-title":"Discussion on damp rate and out-of-resonance degree of power compensation network","volume":"33","author":"chen","year":"2005","journal-title":"Relay"},{"key":"ref8","first-page":"221","article-title":"The device for the detection of three-phase networks with phase wire breakage","volume":"3","author":"klochkov","year":"2011","journal-title":"The Bulletin of KrasGAU"},{"key":"ref7","doi-asserted-by":"publisher","DOI":"10.1109\/ETECHNXT.2018.8385340"},{"key":"ref9","first-page":"17","article-title":"Reliability indicators of a 10kV OHL network","volume":"6","author":"sherstobitov","year":"2011","journal-title":"Agricultural Mechanization and Electrification"},{"key":"ref4","first-page":"1","article-title":"Discussion on several problems of earthing fault protection in distribution network","volume":"43","author":"xu","year":"2019","journal-title":"Autom Electr Power Syst"},{"key":"ref3","doi-asserted-by":"publisher","DOI":"10.1109\/IS3C.2014.51"},{"key":"ref6","doi-asserted-by":"publisher","DOI":"10.1109\/ICIEAM48468.2020.9111899"},{"key":"ref5","doi-asserted-by":"crossref","first-page":"1350","DOI":"10.1109\/TPWRD.2016.2526054","article-title":"A novel neutral electromagnetic hybrid flexible grounding method in distribution networks","volume":"32","author":"wang","year":"2017","journal-title":"IEEE Trans Power Del"}],"container-title":["IEEE Access"],"original-title":[],"link":[{"URL":"http:\/\/xplorestaging.ieee.org\/ielx7\/6287639\/10005208\/10295446.pdf?arnumber=10295446","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,11,27]],"date-time":"2023-11-27T15:01:20Z","timestamp":1701097280000},"score":1,"resource":{"primary":{"URL":"https:\/\/ieeexplore.ieee.org\/document\/10295446\/"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023]]},"references-count":32,"URL":"https:\/\/doi.org\/10.1109\/access.2023.3327337","relation":{},"ISSN":["2169-3536"],"issn-type":[{"value":"2169-3536","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023]]}}}