{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,6]],"date-time":"2026-04-06T11:58:16Z","timestamp":1775476696069,"version":"3.50.1"},"reference-count":46,"publisher":"Institute of Electrical and Electronics Engineers (IEEE)","license":[{"start":{"date-parts":[[2023,1,1]],"date-time":"2023-01-01T00:00:00Z","timestamp":1672531200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100012166","name":"National Key Research and Development Program of China","doi-asserted-by":"publisher","award":["2021YFB1507005"],"award-info":[{"award-number":["2021YFB1507005"]}],"id":[{"id":"10.13039\/501100012166","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["IEEE Access"],"published-print":{"date-parts":[[2023]]},"DOI":"10.1109\/access.2023.3332359","type":"journal-article","created":{"date-parts":[[2023,11,13]],"date-time":"2023-11-13T19:28:08Z","timestamp":1699903688000},"page":"129340-129352","source":"Crossref","is-referenced-by-count":4,"title":["Grid-Connected Adaptive Analysis and Control of the DC Wind Turbine Under the Grid-Side Transient Faults"],"prefix":"10.1109","volume":"11","author":[{"given":"Zhanlong","family":"Li","sequence":"first","affiliation":[{"name":"Beijing Gold Wind Science and Creation Wind Power Equipment Company Ltd., Beijing, China"}]},{"ORCID":"https:\/\/orcid.org\/0009-0003-1295-192X","authenticated-orcid":false,"given":"Haiyang","family":"Han","sequence":"additional","affiliation":[{"name":"College of Electrical Engineering, Xinjiang University, Urumqi, China"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-7911-0055","authenticated-orcid":false,"given":"Haiyun","family":"Wang","sequence":"additional","affiliation":[{"name":"College of Electrical Engineering, Xinjiang University, Urumqi, China"}]},{"given":"Qita","family":"Feng","sequence":"additional","affiliation":[{"name":"Beijing Gold Wind Science and Creation Wind Power Equipment Company Ltd., Beijing, China"}]}],"member":"263","reference":[{"issue":"21","key":"ref1","first-page":"33","article-title":"Development status and key technologies of large-capacity offshore wind turbines","volume":"45","author":"Yao","year":"2021","journal-title":"Automat. Electr. Power Syst."},{"issue":"9","key":"ref2","first-page":"2424","article-title":"Research status and developing prospect of offshore wind farm with pure DC systems","volume":"39","author":"Jiang","year":"2015","journal-title":"Power Syst. Technol."},{"issue":"8","key":"ref3","first-page":"2036","article-title":"Present status and future development of offshore all-DC wind farm","volume":"36","author":"Cai","year":"2016","journal-title":"Proc. CSEE"},{"issue":"21","key":"ref4","first-page":"2","article-title":"Review on offshore wind power integration via DC transmission","volume":"45","author":"Cai","year":"2021","journal-title":"Automat. Electr. Power Syst."},{"key":"ref5","doi-asserted-by":"publisher","DOI":"10.1109\/TIA.2013.2272032"},{"key":"ref6","doi-asserted-by":"publisher","DOI":"10.1109\/TPEL.2012.2198835"},{"key":"ref7","doi-asserted-by":"publisher","DOI":"10.1109\/TIE.2014.2363818"},{"key":"ref8","doi-asserted-by":"publisher","DOI":"10.1109\/IECON.2015.7392290"},{"issue":"2","key":"ref9","first-page":"507","article-title":"One kind of large-scale DC wind turbine and its control technology based on dual phase-shift power conversion","volume":"43","author":"Liu","year":"2023","journal-title":"Proc. CSEE"},{"key":"ref10","article-title":"One kind of new DC wind turbine based on parallel charging and series discharge conversion and its control technology","author":"Han","journal-title":"Power Syst. Technol."},{"issue":"2","key":"ref11","first-page":"1","article-title":"Methods of individual pitch control for large wind turbine","volume":"44","author":"Han","year":"2016","journal-title":"Power Syst. Protection Control"},{"issue":"24","key":"ref12","first-page":"83","article-title":"Research on the fault ride-through optimal control strategy of PMSG-based wind turbine","volume":"43","author":"Wang","year":"2015","journal-title":"Power Syst. Protection Control"},{"key":"ref13","doi-asserted-by":"publisher","DOI":"10.35833\/MPCE.2019.000321"},{"key":"ref14","doi-asserted-by":"publisher","DOI":"10.1109\/TEC.2013.2261301"},{"issue":"10","key":"ref15","first-page":"1528","article-title":"Design and application of supercapacitor energy storage system used in low voltage ride through of wind power generation system","volume":"34","author":"Wang","year":"2014","journal-title":"Proc. CSEE"},{"issue":"14","key":"ref16","first-page":"55","article-title":"Research on fault characteristics of grid-connected large scale wind farms with LVRT capability","volume":"43","author":"Qi","year":"2015","journal-title":"Power Syst. Protection Control"},{"issue":"1","key":"ref17","first-page":"11","article-title":"Low voltage ride-through capability improvement of PMSG based on chopper circuit and reactive priority control","volume":"42","author":"Ren","year":"2016","journal-title":"High Voltage Eng."},{"issue":"1","key":"ref18","first-page":"29","article-title":"Control strategy of low-voltage ride-through for direct-drive wind power generation system","volume":"32","author":"Li","year":"2012","journal-title":"Electr. Power Autom. Equip."},{"issue":"18","key":"ref19","first-page":"98","article-title":"Adaptive switching strategy for a wind turbine crowbar based on the guarantee of low voltage ride-through capability","volume":"49","author":"Tan","year":"2021","journal-title":"Power Syst. Protection Control"},{"key":"ref20","doi-asserted-by":"publisher","DOI":"10.1109\/ICPE.2011.5944550"},{"issue":"2","key":"ref21","first-page":"135","article-title":"Research on reactive power control and the low-voltage ride-through capability of PMSG","volume":"40","author":"Liu","year":"2012","journal-title":"Power Syst. Protection Control"},{"key":"ref22","doi-asserted-by":"publisher","DOI":"10.1109\/TIE.2012.2229673"},{"key":"ref23","doi-asserted-by":"publisher","DOI":"10.1109\/TPEL.2018.2803125"},{"issue":"16","key":"ref24","first-page":"76","article-title":"Control strategy and experiment of high voltage ride through for DFIG-based wind turbines","volume":"40","author":"Li","year":"2016","journal-title":"Automat. Electr. Power Syst."},{"issue":"11","key":"ref25","first-page":"3037","article-title":"High voltage ride-through control strategy of doubly-fed induction generator based wind turbines with a series grid-side converter","volume":"38","author":"Li","year":"2014","journal-title":"Power Syst. Technol."},{"key":"ref26","doi-asserted-by":"publisher","DOI":"10.1016\/j.epsr.2011.02.010"},{"key":"ref27","doi-asserted-by":"publisher","DOI":"10.1109\/TIA.2018.2877400"},{"issue":"9","key":"ref28","first-page":"69","article-title":"A coordinated control strategy for fault ride-though capacity of direct-drive permanent magnet wind power generating units","volume":"44","author":"Bian","year":"2016","journal-title":"Power Syst. Protection Control"},{"issue":"19","key":"ref29","first-page":"147","article-title":"Summarizing for fault ride through characteristics of wind turbines","volume":"41","author":"Usman","year":"2013","journal-title":"Power Syst. Protection Control"},{"key":"ref30","doi-asserted-by":"publisher","DOI":"10.1109\/TIE.2020.2994878"},{"issue":"7","key":"ref31","first-page":"1868","article-title":"Development and test of HVRT function for PMSG","volume":"37","author":"Usman","year":"2013","journal-title":"Electr. Power Autom. Equip."},{"issue":"12","key":"ref32","first-page":"18","article-title":"Optimal value and group switching strategy of dump resistance for direct-drive permanent magnet synchronous generators","volume":"36","author":"Li","year":"2016","journal-title":"Power Syst. Technol."},{"key":"ref33","volume-title":"Technical Specification for Connecting Wind Farm to Power System\u2014Part 1: On Shore Wind Power","year":"2021"},{"key":"ref34","doi-asserted-by":"publisher","DOI":"10.1109\/ACCESS.2020.3040905"},{"issue":"5","key":"ref35","first-page":"73","article-title":"Coordinated control of active and reactive power of PMSG-based wind turbines for low voltage ride through","volume":"28","author":"Li","year":"2013","journal-title":"Trans. China Electrotech. Soc."},{"issue":"2","key":"ref36","first-page":"146","article-title":"Grid side fault ride through solution for offshore wind connection with VSC-HVDC","volume":"2","author":"Wang","year":"2019","journal-title":"J. Global Energy Interconnection"},{"issue":"18","key":"ref37","first-page":"106","article-title":"Low voltage ride-through strategy for high-capacity direct-drive wind turbines based on supercapacitor energy storage","volume":"51","author":"Yang","year":"2023","journal-title":"Power Syst. Protection Control"},{"issue":"5","key":"ref38","first-page":"152","article-title":"Analysis of double-fed wind turbine\u2019s secondary high voltage ride-through characteristics considering the crowbar circuit","volume":"47","author":"Zhou","year":"2019","journal-title":"Power Syst. Protection Control"},{"issue":"7","key":"ref39","first-page":"37","article-title":"AC and DC fault ride-through strategies for wind power integration via hybrid MMC-HVDC","volume":"42","author":"Cao","year":"2018","journal-title":"Automat. Electr. Power Syst."},{"issue":"3","key":"ref40","first-page":"18","article-title":"Multi-objective unit commitment optimization model including hybrid wind-storage system and its solution","volume":"35","author":"Xie","year":"2015","journal-title":"Electr. Power Autom. Equip."},{"issue":"10","key":"ref41","first-page":"138","article-title":"Fault ride through capability of direct drive permanent magnet wind power generation connected to grid based on SMES-SFCL","volume":"34","author":"Wang","year":"2022","journal-title":"Proc. CSU-EPSA"},{"issue":"12","key":"ref42","first-page":"1","article-title":"Analysis and prospect of LVRT improvement based on energy storage technology for wind turbine generator system","volume":"35","author":"Yang","year":"2015","journal-title":"Electr. Power Autom. Equip."},{"issue":"10","key":"ref43","first-page":"162","article-title":"Control strategy of energy storage system in wind farm group to improve wind energy utilization level","volume":"41","author":"Li","year":"2021","journal-title":"Electr. Power Autom. Equip."},{"issue":"10","key":"ref44","first-page":"131","article-title":"Smoothing wind power fluctuation control strategy for an energy storage system considering wind power consumption in the valley period","volume":"51","author":"Yang","year":"2023","journal-title":"Power Syst. Protection Control"},{"issue":"8","key":"ref45","first-page":"2708","article-title":"Method for realizing DC output of wind turbine based on diode rectifier","volume":"47","author":"Yang","year":"2021","journal-title":"High Voltage Eng."},{"issue":"7","key":"ref46","first-page":"158","article-title":"Adaptive coordinated control of fault voltage ride-through for wind turbine based on energy storage","volume":"47","author":"Chen","year":"2023","journal-title":"Automat. Electr. Power Syst."}],"container-title":["IEEE Access"],"original-title":[],"link":[{"URL":"http:\/\/xplorestaging.ieee.org\/ielx7\/6287639\/10005208\/10316282.pdf?arnumber=10316282","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,3,2]],"date-time":"2024-03-02T18:18:10Z","timestamp":1709403490000},"score":1,"resource":{"primary":{"URL":"https:\/\/ieeexplore.ieee.org\/document\/10316282\/"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023]]},"references-count":46,"URL":"https:\/\/doi.org\/10.1109\/access.2023.3332359","relation":{},"ISSN":["2169-3536"],"issn-type":[{"value":"2169-3536","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023]]}}}